Test Report

FCC ID: R9C-R827

Test Report

Download: PDF
FCCID_2140214

                                                                                                                   Report No.:SZ13100153E01




                                      FCC TEST REPQ@RT
                                                                    Issued to                       ’{f\/\\\s                       >
                                                                                                          utss                  ofk§VYG,,
                  GUANGDONG OPPO MOBILE TELECOMMUNICATIONS CORP., LTD.



                                                                        For

                                                                  Mobile Phone


                                    Model Name:                    OPPO R827
                                    Trade Name:                    OPPO
                                    Brand Name:                    OPPO
                                    FCC ID:                        RIC—R827
                                    Standard:                      47 CFR Part 15 Subpart B
                                    Test date:                     November 7, 2013 — November 19, 2013
                                    Issue date:                    November 26, 2013



                                                                         By


                                                                                                   hina 518101



  Tested by                                                                                               Review by Wu i& l.'
                 Cai Junlong                                                                                                Wu Zhangli
                 (Test Engineer)                                                                                           (EMC Manager)
  Date       2s(% . [l «26                                                                                Date              213 » I{. 26
The report refers only to the sample tested and does not apply to the bulk. This report is issued in confidence to the clent and 2 will be strictly treated as
such by the Shnzhen MORLAB Communication Technology Co., Ltd. t may not be reproduced rather in s entirety or in part and it may not be used for
adverting. The cllent to whomthe report is issued may, however, show or send i or a certffed copy there of prepared by the Shenzhan MORLAB
Telecommunication Co , Ltd to his customer. Suppler or others persons directly concerned. Shenzhen MORLAB Telecommunication Co.. Lid will not
without the consent of the clent enter into any discussion of correspondance with any third party concerning the contents of the report.In the event of the
improper use ofthe report, Shenzhen MORLAB Telecommunication Co., Lid reserves the rights to withdraw it and to adopt any other remedias which may
be appropriate

Shenzhen Morlab Communications Technology Co., Ltd.                                                                     Phone: +86 (0) 755 36698555
Web site: hitp—iwww morlab.cn/                                                                                              Fax: +86 (0) 755 36698525


                                                                                                                          Report No.: SZ13100153E01

                                                        TABLE OF CONTENTS

1. GENERAL INFORMATION ...................................................................................................................... 3


1.1 EUT DESCRIPTION.................................................................................................................................... 3
1.2 TEST STANDARDS AND RESULTS .............................................................................................................. 4
1.3 FACILITIES AND ACCREDITATIONS ............................................................................................................. 5
1.3.1 FACILITIES ........................................................................................................................................................5
1.3.2 FACILITIES ........................................................................................................................................................5
1.3.3 MEASUREMENT UNCERTAINTY ....................................................................................................................... 5


2. TEST CONDITIONS SETTING ................................................................................................................ 6


2.1 TEST MODE .............................................................................................................................................. 6
2.2 TEST SETUP AND EQUIPMENTS LIST ......................................................................................................... 7
2.2.1 CONDUCTED EMISSION ...................................................................................................................................7
2.2.2 RADIATED EMISSION .......................................................................................................................................8


3. 47 CFR PART 15B REQUIREMENTS ...................................................................................................10


3.1 CONDUCTED EMISSION ............................................................................................................................10
3.1.1 REQUIREMENT ...............................................................................................................................................10
3.1.2 TEST DESCRIPTION .......................................................................................................................................10
3.1.3 TEST RESULT .................................................................................................................................................10
3.2 RADIATED EMISSION ................................................................................................................................12
3.2.1 REQUIREMENT ...............................................................................................................................................12
3.2.2 TEST DESCRIPTION .......................................................................................................................................12
3.2.3 FREQUENCY RANGE OF MEASUREMENT ...................................................................................................... 12
3.2.4 TEST RESULT .................................................................................................................................................13




                                                                       Change History
                   Issue                                Date                                             Reason for change
                     1.0                   November 26, 2013                                                   First edition




Shenzhen Morlab Communications Technology Co., Ltd                                                                                Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                                                                                                       Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                                                                                                 Page 2 of 15


                                                                              Report No.: SZ13100153E01


1.        GENERAL INFORMATION

1.1       EUT Description
                 EUT Type: Mobile Phone
                 Serial No: (n.a., marked #1 by test site)
      Hardware Version: 213071
       Software Version: R827AS_11_1.01_131005
                 Applicant: GUANGDONG OPPO MOBILE TELECOMMUNICATIONS CORP., LTD.
                            NO.18 HAIBIN ROAD, WUSHA, CHANG'AN, DONGGUAN, GUANGDONG,
                            CHINA
            Manufacturer: GUANGDONG OPPO MOBILE TELECOMMUNICATIONS CORP., LTD.
                          NO.18 HAIBIN ROAD, WUSHA, CHANG'AN, DONGGUAN, GUANGDONG,
                          CHINA


            Power supply: Battery
                          Brand Name:                OPPO
                                  Model No.:         BLP563
                                  Serial No.:        (n.a. marked #1 by test site)
                                  Capacitance:       2000mAh
                                  Rated Voltage:     3.8V
                                  Charge Limit:      4.35V
   Ancillary Equipment: AC Adapter (Charger for Battery)
                                  Brand Name:        OPPO
                                  Model No.:         S01A22
                                  Serial No.:        (n.a. marked #1 by test site)
                                  Rated Input:          100-240V, 200mA, 50/60Hz
                                  Rated Output:         5V, 1000mA

NOTE:

 1. The EUT is a Mobile Phone, it is equipped with a T-Flash card slot, a Micro-USB port which can be
      connected to the ancillary equipments e.g. the PC.
 2. Please refer to Annex A for the photographs of the EUT. For a more detailed description, please refer
      to Specification or User’s Manual supplied by the applicant and/or manufacturer.




Shenzhen Morlab Communications Technology Co., Ltd                                   Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                                                        Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                                            Page 3 of 15


                                                                              Report No.: SZ13100153E01

1.2       Test Standards and Results
The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:

           No.     Identity                            Document Title
           1       47 CFR Part 15(10-1-12 Edition)     Radio Frequency Devices

Test detailed items/section required by FCC rules and results are as below:

          No.     Section         Description                                              Result
          1       15.107          Conducted Emission                                       PASS
          2       15.109          Radiated Emission                                        PASS

NOTE: The tests were performed according to the method of measurements prescribed in ANSI
C63.4-2009.




Shenzhen Morlab Communications Technology Co., Ltd                                Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                                                     Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                                            Page 4 of 15


                                                                          Report No.: SZ13100153E01

1.3       Facilities and Accreditations

1.3.1     Facilities

Shenzhen Morlab Communications Technology Co., Ltd. Morlab Laboratory is a testing organization
accredited by China National Accreditation Service for Conformity Assessment (CNAS) according to
ISO/IEC 17025. The accreditation certificate number is L3572.

All measurement facilities used to collect the measurement data are located at FL.3, Building A, FeiYang
Science Park, No.8 LongChang Road, Block 67, BaoAn District, ShenZhen, GuangDong Province, P. R.
China 518101. The test site is constructed in conformance with the requirements of ANSI C63.4-2009 and
CISPR Publication 22:2010; the FCC registration number is 695796.


1.3.2     Facilities

During the measurement, the environmental conditions were within the listed ranges:

 Temperature (°C):                             15 - 35
 Relative Humidity (%):                        30 - 60
 Atmospheric Pressure (kPa):                   86 -106


1.3.3     Measurement Uncertainty

The uncertainty is calculated using the methods suggested in the "Guide to the Expression of Uncertainty
in Measurement" (GUM) published by ISO.

 Uncertainty of Conducted Emission:            ±1.8dB
 Uncertainty of Radiated Emission:             ±3.1dB




Shenzhen Morlab Communications Technology Co., Ltd                             Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                                                   Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                                       Page 5 of 15


                                                                            Report No.: SZ13100153E01

2.         TEST CONDITIONS SETTING

2.1        Test Mode
       1         The first test mode (Data Transmission)
                 The EUT configuration of the emission tests is EUT + TransFlash Card + Battery + PC.
                 During the measurement, the EUT with a TransFlash Card embedded was connected
                 with a PC via the Micro-USB port, the data is transmitting between the PC and the
                 TransFlash Card of the EUT.
       2         The second test mode (Standby)
                 The EUT configuration of the emission tests is EUT + Battery + Charger.
                 During the measurement, the EUT was charged by its adapter and turned on.
       Note: All test modes are performed, only the worst case(Data Transmission) is recorded in this
       report.




Shenzhen Morlab Communications Technology Co., Ltd                               Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                                                    Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                                        Page 6 of 15


                                                                                   Report No.: SZ13100153E01

2.2       Test Setup and Equipments List

2.2.1     Conducted Emission

A. Test Setup:



        < 40cm >                       < 80cm >




                        EUT

                                                                        Pulse Limiter
       < 80cm >                                               LISN
                                                                                    Receiver




The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor, and
keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power mains through
a LISN which provides 50Ω/50µH of coupling impedance for the measuring instrument. A Pulse Limiter is
used to protect the measuring instrument. The factors of the whole test system are calibrated to correct
the reading.

B. Equipments List:

       Description            Manufacturer           Model            Serial No.        Cal. Date      Due. Date
         Receiver                   Narda         PMM 9010           595WX11007      12/11/2013       11/11/2014
      EMC Analyzer                  Agilent          E7405A          US44210471      12/05/2013       11/05/2014
           LISN                   Schwarzbeck     NSLK 8127            812744        12/05/2013       11/05/2014
  Pulse Limiter (20dB)            Schwarzbeck   VTSD 9561-D             9391              (n.a.)         (n.a.)
    System Simulator                Agilent          E5515C          GB43130131      12/05/2013       11/05/2014
       T-Flash Card                 SanDisk          256MB              (n.a.)            (n.a.)         (n.a.)
             PC                     Lenovo      ThinkPadT61           ZZF3077             (n.a.)         (n.a.)




Shenzhen Morlab Communications Technology Co., Ltd                                       Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                                                             Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                                                 Page 7 of 15


                                                      Report No.: SZ13100153E01

2.2.2     Radiated Emission

A. Test Setup:
     1)   For radiated emissions from 9kHz to 30MHz




     2)   For radiated emissions from 30MHz to1GHz




     3)   For radiated emissions above 1GHz


Shenzhen Morlab Communications Technology Co., Ltd        Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                             Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                 Page 8 of 15


                                                                             Report No.: SZ13100153E01




The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of the
site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating Turn Table,
and keeps 3m away from the Test Antenna, which is mounted on a variable-height antenna master tower.

For the test Antenna:

 1)   In the frequency range of 9KHz to 30MHz, magnetic field is measured with Loop Test Antenna. The
      Test Antenna is positioned with its plane vertical at 1m distance from the EUT. The center of the
      Loop Test Antenna is 1m above the ground. During the measurement the Loop Test Antenna rotates
      about its vertical axis for maximum response at each azimuth about the EUT.

 2)   In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test
      Antenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna height is
      varied from 1m to 4m above the ground to determine the maximum value of the field strength. The
      emission levels at both horizontal and vertical polarizations should be tested.

B. Equipments List:

       Description                Manufacturer       Model      Serial No.      Cal. Date       Due. Date
      EMC Analyzer                   Agilent         E7405A    US44210471       12/05/2013      11/05/2014
      Semi-Anechoic                 Albatross    9m*6m*6m         (n.a.)        12/05/2012      11/05/2014
        Chamber
  Test Antenna - Bi-Log           Schwarzbeck    VULB 9163      9163-274        12/05/2012      11/05/2014
   Test Antenna - Horn            Schwarzbeck    BBHA 9120D    9120D-963        12/05/2012      11/05/2014
   Test Antenna -Loop             Schwarzbeck    FMZB 1519      1519-022        12/05/2012      11/05/2014
       T-Flash Card                 SanDisk          256MB        (n.a.)           (n.a.)          (n.a.)
             PC                     Lenovo       ThinkPadT61    ZZF3077            (n.a.)          (n.a.)


Shenzhen Morlab Communications Technology Co., Ltd                                 Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                                                      Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                                          Page 9 of 15


                                                                             Report No.: SZ13100153E01

3.        47 CFR PART 15B REQUIREMENTS

3.1       Conducted Emission

3.1.1     Requirement

According to FCC section 15.107, the radio frequency voltage that is conducted back onto the AC power
line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the following table,
as measured using a 50µH/50Ω line impedance stabilization network (LISN).

                                                          Conducted Limit (dBµV)
 Frequency range (MHz)
                                             Quasi-peak                            Average
          0.15 - 0.50                          66 to 56                             56 to 46
            0.50 - 5                                 56                                46
             5 - 30                                  60                                50
NOTE:
a) The limit subjects to the Class B digital device.
b) The lower limit shall apply at the band edges.
c)    The limit decreases linearly with the logarithm of the frequency in the range 0.15 - 0.50MHz.


3.1.2     Test Description

See section 2.2.1 of this report.


3.1.3     Test Result

The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average (AV)
detectors; the emission levels more than the AV and QP limits, and that have narrow margins from the AV
and QP limits will be re-measured with AV and QP detectors. Tests for both L phase and N phase lines of
the power mains connected to the EUT are performed. All test modes are considered, refer to recorded
points and plots below.

A. Test Plot and Suspicious Points:




Shenzhen Morlab Communications Technology Co., Ltd                                 Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                                                      Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                                         Page 10 of 15


                                                                   Report No.: SZ13100153E01




                                               (Plot A: L Phase)




                                               (Plot B: N Phase)


Test Result: PASS



Shenzhen Morlab Communications Technology Co., Ltd                     Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                                          Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                             Page 11 of 15


                                                                            Report No.: SZ13100153E01

3.2       Radiated Emission

3.2.1     Requirement

According to FCC section 15.109(a)(e), the field strength of radiated emissions from unintentional
radiators at a distance of 3 meters shall not exceed the following values:

       Frequency                  Field Strength     Field Strength Limitation at 3m Measurement Dist
      range (MHz)             µV/m            Dist          (uV/m)                   (dBuV/m)
      0.009 - 0.490        2400/F(KHz)        300m    10000* 2400/F(KHz)      20log 2400/F(KHz) + 80
      0.490 - 1.705        2400/F(KHz)        30m      100* 2400/F(KHz)       20log 2400/F(KHz) + 40
      1.705 - 30.00               30          30m           100*30                 20log 30 + 40
        30.0 - 88.0               100          3m             100                    20log 100
      88.0 - 216.0                150          3m             150                    20log 150
      216.0 - 960.0               200          3m             200                    20log 200
      Above 960.0                 500          3m             500                    20log 500

Note: The limits of frequency below 30MHz is quoted from the FCC section 15.209.

As shown in FCC section 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
average detector. When average radiated emission measurements are specified in this part, including
emission measurements below 1000MHz, there also is a limit on the radio frequency emissions, as
measured using instrumentation with a peak detector function, corresponding to 20dB above the
maximum permitted average limit for the frequency being investigated unless a different peak emission
limit is otherwise specified in the rules.

Note:

1)    The tighter limit shall apply at the boundary between two frequency range.
2)    Limitation expressed in dBuV/m is calculated by 20log Emission Level(uV/m).
3)    If measurement is made at 3m distance, then F.S Limitation at 3m distance is adjusted by using the
      formula of Ld1 = Ld2 * (d2/d1)2.
      Example:
      F.S Limit at 30m distance is 30uV/m, then F.S Limitation at 3m distance is adjusted as
      Ld1 = L1 = 30uV/m * (10)2 = 100 * 30uV/m


3.2.2     Test Description

See section 2.2.2 of this report.


3.2.3     Frequency range of measurement

Highest frequency generated or used in the device is the highest speed of the processor, lowest

Shenzhen Morlab Communications Technology Co., Ltd                              Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                                                    Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                                       Page 12 of 15


                                                                                                                  Report No.: SZ13100153E01
frequency generated or used in the device is the lowest frequency of the oscillator. According to
15.33(b)(1), the frequency range of radiated measurement for the EUT is listed in the following table:

                                    Frequency generated or used in the                                   Frequency range of radiated
         Frequency
                                                 device                                                   measurement in the report
               Highest                                        1.3GHz                                                      6.5GHz
               Lowest                                          32KHz                                                        9KHz


3.2.4       Test Result

The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels more
than the limits, and that have narrow margins from the limits will be re-measured with AV and QP
detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered to perform
the tests. All test modes are considered, refer to recorded points and plots below.

The amplitude of spurious emissions which are attenuated more than 20 dB below the permissible value
need not be reported.

Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis test
condition was recorded in this test report.

A. Test Plots and Suspicious Points:
NOTE: The emissions are too small to be measured and are at least 6 dB below the limit, So all the data
of marked are pass.

        160DBuV

            No Frequency       PeakAp     QP-Limit       AV-Limit     Quasi-P    Avera-P       Result
             1     129 K   42.81 DBuV       105.39             --           --         --          --
        140DBuV
              2   1.21 M   33.49 DBuV        45.98             --           --         --          --


        120DBuV



        100DBuV



        80DBuV



        60DBuV


                                                         1
        40DBuV                                                                                      2



        20DBuV



        0DBuV



        -20DBuV

       9K10K        20K    30K   40K 50K60K70K80K
                                                90K
                                                  100K         200K     300K 400K500K600K
                                                                                        700K
                                                                                           800K
                                                                                             900K
                                                                                               1M       2M   3M   4M   5M 6M 7M8M9M10M    20M 30M



                                                                    (Plot A: 9K – 30M)



Shenzhen Morlab Communications Technology Co., Ltd                                                                          Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                                                                                                Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                                                                                   Page 13 of 15


                                                                                   Report No.: SZ13100153E01




                                  (Plot B: 30MHz – 8GHz, Test Antenna Vertical)




          NO.        Fre.          Pk      QP     AV    Limit-   Limit-   Limit-     Antenna     Verdict
                    (MHz)                                PK       QP       AV
           1       97.731         N.A     27.75   N.A   N.A      43.5     N.A        Vertical     Pass
           2      158.204         N.A     33.11   N.A   N.A      43.5     N.A        Vertical     Pass
           3      390.424         N.A     31.35   N.A   N.A      46.0     N.A        Vertical     Pass
           4      479.925         N.A     23.61   N.A   N.A      46.0     N.A        Vertical     Pass
           5      680.698         N.A     34.89   N.A   N.A      46.0     N.A        Vertical     Pass
           6      2830.424        44.15   N.A     N.A   74.0     N.A      54.0       Vertical     Pass




Shenzhen Morlab Communications Technology Co., Ltd                                     Phone: +86 (0) 755 36698555
Web site: http://www.morlab.cn/                                                          Fax: +86 (0) 755 36698525
Email: info_sz@morlab.cn                                                                             Page 14 of 15


                                                                                     Report No.: SZ13100153E01




                                  (Plot C: 30MHz – 8GHz, Test Antenna Horizontal)




         NO.        Fre.           Pk      QP       AV    Limit-   Limit-   Limit-    Antenna      Verdict
                   (MHz)                                   PK       QP       AV
           1      59.027           N.A    24.89     N.A   N.A      40.0     N.A      Horizontal     Pass
           2      167.880          N.A    32.40     N.A   N.A      43.5     N.A      Horizontal     Pass
           3      235.611          N.A    33.22     N.A   N.A      46.0     N.A      Horizontal     Pass
           4      380.748          N.A    31.47     N.A   N.A      46.0     N.A      Horizontal     Pass
           5      772.618          N.A    31.32     N.A   N.A      46.0     N.A      Horizontal     Pass
           6     2820.449         44.14   N.A       N.A   74.0     N.A      54.0     Horizontal     Pass

Test Result: PASS

                                                  **END OF REPORT **




Shenzhen Morlab Communications Technology Co., Ltd                                       Phone: +86 (0) 755 36698555