Test Report_SAR_Appendix A

FCC ID: R9C-CPH1941

RF Exposure Info

Download: PDF
FCCID_4496262

                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                              Date: 2019-10-03

System Check_H835_1003

DUT: Dipole 835 MHz D835V2;SN:4d160;

Communication System: UID 0, CW (0); Frequency: 835 MHz; Duty Cycle: 1:1
Medium parameters used: f = 835 MHz; σ = 0.902 S/m; εr = 42.401; ρ = 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:22.4 ℃

DASY Configuration:

   •   Probe: ES3DV3 - SN3162; ConvF(5.92, 5.92, 5.92) @ 835 MHz; Calibrated: 2019-04-12
   •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 2.0, 32.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Right v5.0; Type: QD000P40CC; Serial: TP:1469
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x13x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 2.81 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 64.58 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 3.95 W/kg
SAR(1 g) = 2.39 W/kg; SAR(10 g) = 1.49 W/kg
Maximum value of SAR (measured) = 2.95 W/kg




                                                Page 1 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                              Date: 2019-10-06

System Check_H835_1006

DUT: Dipole 835 MHz D835V2;SN:4d160;

Communication System: UID 0, CW (0); Frequency: 835 MHz; Duty Cycle: 1:1
Medium parameters used: f = 835 MHz; σ = 0.901 S/m; εr = 42.791; ρ = 1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.2 ℃

DASY Configuration:

   •   Probe: ES3DV3 - SN3162; ConvF(5.92, 5.92, 5.92) @ 835 MHz; Calibrated: 2019-04-12
   •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 2.0, 32.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Right v5.0; Type: QD000P40CC; Serial: TP:1469
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x13x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 2.78 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 64.17 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 3.92 W/kg
SAR(1 g) = 2.4 W/kg; SAR(10 g) = 1.48 W/kg
Maximum value of SAR (measured) = 2.90 W/kg




                                                Page 2 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                               Date: 2019-10-08

System Check_H835_1008

DUT: Dipole 835 MHz D835V2;SN:4d160;

Communication System: UID 0, CW (0); Frequency: 835 MHz; Duty Cycle: 1:1
Medium parameters used: f = 835 MHz; σ = 0.9 S/m; εr = 42.763; ρ = 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:22.5 ℃

DASY Configuration:

   •   Probe: ES3DV3 - SN3162; ConvF(5.92, 5.92, 5.92) @ 835 MHz; Calibrated: 2019-04-12
   •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 2.0, 32.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Right v5.0; Type: QD000P40CC; Serial: TP:1469
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x13x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 2.80 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 64.52 V/m; Power Drift = -0.00 dB
Peak SAR (extrapolated) = 3.93 W/kg
SAR(1 g) = 2.42 W/kg; SAR(10 g) = 1.49 W/kg
Maximum value of SAR (measured) = 2.94 W/kg




                                                Page 3 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                              Date: 2019-10-09

System Check_H835_1009

DUT: Dipole 835 MHz D835V2;SN:4d160;

Communication System: UID 0, CW (0); Frequency: 835 MHz; Duty Cycle: 1:1
Medium parameters used: f = 835 MHz; σ = 0.902 S/m; εr = 42.411; ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.3 ℃

DASY Configuration:

   •   Probe: ES3DV3 - SN3162; ConvF(5.92, 5.92, 5.92) @ 835 MHz; Calibrated: 2019-04-12
   •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 2.0, 32.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Right v5.0; Type: QD000P40CC; Serial: TP:1469
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x13x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 2.81 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 64.64 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 3.95 W/kg
SAR(1 g) = 2.41 W/kg; SAR(10 g) = 1.49 W/kg
Maximum value of SAR (measured) = 2.95 W/kg




                                                Page 4 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                         Date: 2019-10-15

System Check_H835_1015

DUT: Dipole 835 MHz D835V2;

Communication System: UID 0, CW (0); Frequency: 835 MHz; Duty Cycle: 1:1
Medium parameters used: f = 835 MHz; σ = 0.89 S/m; εr = 42.987; ρ = 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:22.3 ℃

DASY Configuration:

   •   Probe: EX3DV4 - SN7544; ConvF(10.14, 10.14, 10.14) @ 835 MHz; Calibrated: 2019-09-09
   •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 1.0, 31.0
   •   Electronics: DAE4 Sn878; Calibrated: 2018-12-12
   •   Phantom: SAM Right v5.0; Type: QD000P40CC; Serial: TP:1469
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (7x13x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 3.03 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 56.85 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 3.46 W/kg
SAR(1 g) = 2.23 W/kg; SAR(10 g) = 1.45 W/kg
Maximum value of SAR (measured) = 3.03 W/kg




                                                Page 5 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                         Date: 2019-10-16

System Check_H835_1016

DUT: Dipole 835 MHz D835V2;SN:4d160;

Communication System: UID 0, CW (0); Frequency: 835 MHz; Duty Cycle: 1:1
Medium parameters used: f = 835 MHz; σ = 0.89 S/m; εr = 42.994; ρ = 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:22.5 ℃

DASY Configuration:

   •   Probe: EX3DV4 - SN7544; ConvF(10.14, 10.14, 10.14) @ 835 MHz; Calibrated: 2019-09-09
   •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 1.0, 31.0
   •   Electronics: DAE4 Sn878; Calibrated: 2018-12-12
   •   Phantom: SAM Right v5.0; Type: QD000P40CC; Serial: TP:1469
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x13x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 2.76 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 64.52 V/m; Power Drift = -0.00 dB
Peak SAR (extrapolated) = 3.89 W/kg
SAR(1 g) = 2.39 W/kg; SAR(10 g) = 1.47 W/kg
Maximum value of SAR (measured) = 2.91 W/kg




                                                Page 6 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                                 Date: 2019-09-29

System Check_H1750_0929

DUT: Dipole 1750 MHz D1750V2;SN:1101;

Communication System: UID 0, CW (0); Frequency: 1750 MHz; Duty Cycle: 1:1
Medium parameters used: f = 1750 MHz; σ = 1.419 S/m; εr = 38.36; ρ = 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:22.4 ℃

DASY Configuration:

   •   Probe: ES3DV3 - SN3162; ConvF(5.19, 5.19, 5.19) @ 1750 MHz; Calibrated: 2019-04-12
   •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 2.0, 32.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Left; Type: Twin SAM; Serial: 1784
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x8x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 12.2 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 100.5 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 16.4 W/kg
SAR(1 g) = 9.19 W/kg; SAR(10 g) = 4.94 W/kg
Maximum value of SAR (measured) = 11.4 W/kg




                                                Page 7 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                                 Date: 2019-10-01

System Check_H1750_1001

DUT: Dipole 1750 MHz D1750V2;SN:1101;

Communication System: UID 0, CW (0); Frequency: 1750 MHz; Duty Cycle: 1:1
Medium parameters used: f = 1750 MHz; σ = 1.421 S/m; εr = 38.42; ρ = 1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.3 ℃

DASY Configuration:

   •   Probe: ES3DV3 - SN3162; ConvF(5.19, 5.19, 5.19) @ 1750 MHz; Calibrated: 2019-04-12
   •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 2.0, 32.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Left; Type: Twin SAM; Serial: 1784
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x8x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 12.4 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 101.2 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 16.6 W/kg
SAR(1 g) = 9.32 W/kg; SAR(10 g) = 5.02 W/kg
Maximum value of SAR (measured) = 11.5 W/kg




                                                Page 8 of 30


                                                          Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                                 Date: 2019-10-02

System Check_H1750_1002

DUT: Dipole 1750 MHz D1750V2;SN:1101;

Communication System: UID 0, CW (0); Frequency: 1750 MHz; Duty Cycle: 1:1
Medium parameters used: f = 1750 MHz; σ = 1.358 S/m; εr = 39.714; ρ = 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:22.2 ℃

DASY Configuration:

   •   Probe: ES3DV3 - SN3162; ConvF(5.19, 5.19, 5.19) @ 1750 MHz; Calibrated: 2019-04-12
   •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 2.0, 32.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Left; Type: Twin SAM; Serial: 1784
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x8x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 12.2 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 102.5 V/m; Power Drift = -0.00 dB
Peak SAR (extrapolated) = 16.3 W/kg
SAR(1 g) = 9.12 W/kg; SAR(10 g) = 4.91 W/kg
Maximum value of SAR (measured) = 11.3 W/kg




                                                Page 9 of 30


                                                          Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                                 Date: 2019-10-11

System Check_H1750_1011

DUT: Dipole 1750 MHz D1750V2;SN:1101;

Communication System: UID 0, CW (0); Frequency: 1750 MHz; Duty Cycle: 1:1
Medium parameters used: f = 1750 MHz; σ = 1.412 S/m; εr = 41.149; ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.1 ℃

DASY Configuration:

   •   Probe: ES3DV3 - SN3162; ConvF(5.19, 5.19, 5.19) @ 1750 MHz; Calibrated: 2019-04-12
   •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 2.0, 32.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Left; Type: Twin SAM; Serial: 1784
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x8x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 12.9 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 103.7 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 17.4 W/kg
SAR(1 g) = 9.65 W/kg; SAR(10 g) = 5.15 W/kg
Maximum value of SAR (measured) = 12.1 W/kg




                                               Page 10 of 30


                                                          Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL Inc.     Date: 2019/9/28

System Check_H1900_0928

DUT: Dipole 1900 MHz D1900V2;SN:5d179;

Communication System: UID 0, CW (0); Frequency: 1900 MHz; Duty Cycle: 1:1
Medium parameters used: f = 1900 MHz; σ = 1.384 S/m; εr = 39.557; ρ = 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:22.4 ℃

DASY Configuration:

    •   Probe: EX3DV4 - SN7544; ConvF(8.26, 8.26, 8.26) @ 1900 MHz; Calibrated: 2019/9/9
    •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 1.0, 31.0
    •   Electronics: DAE4 Sn878; Calibrated: 2018/12/12
    •   Phantom: SAM Front; Type: Twin SAM; Serial: 1896
    •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x7x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 13.6 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 109.7 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 17.5 W/kg
SAR(1 g) = 9.77 W/kg; SAR(10 g) = 5.11 W/kg
Maximum value of SAR (measured) = 12.4 W/kg




                                                Page 11 of 30


                                                          Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL Inc.     Date: 2019/10/10

System Check_H1900_1010

DUT: Dipole 1900 MHz D1900V2;SN:5d179;

Communication System: UID 0, CW (0); Frequency: 1900 MHz; Duty Cycle: 1:1
Medium parameters used: f = 1900 MHz; σ = 1.379 S/m; εr = 39.603; ρ = 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:22.3 ℃

DASY Configuration:

    •   Probe: EX3DV4 - SN7544; ConvF(8.26, 8.26, 8.26) @ 1900 MHz; Calibrated: 2019/9/9
    •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 1.0, 31.0
    •   Electronics: DAE4 Sn878; Calibrated: 2018/12/12
    •   Phantom: SAM Front; Type: Twin SAM; Serial: 1896
    •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x7x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 14.2 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 112.4 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 18.3 W/kg
SAR(1 g) = 10.2 W/kg; SAR(10 g) = 5.33 W/kg
Maximum value of SAR (measured) = 12.9 W/kg




                                                 Page 12 of 30


                                                          Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL Inc.     Date: 2019/10/11

System Check_H1900_1011

DUT: Dipole 1900 MHz D1900V2;SN:5d179;

Communication System: UID 0, CW (0); Frequency: 1900 MHz; Duty Cycle: 1:1
Medium parameters used: f = 1900 MHz; σ = 1.422 S/m; εr = 39.337; ρ = 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:22.5 ℃

DASY Configuration:

    •   Probe: EX3DV4 - SN7544; ConvF(8.26, 8.26, 8.26) @ 1900 MHz; Calibrated: 2019/9/9
    •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 1.0, 31.0
    •   Electronics: DAE4 Sn878; Calibrated: 2018/12/12
    •   Phantom: SAM Front; Type: Twin SAM; Serial: 1896
    •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x7x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 14.7 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 112.4 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 18.8 W/kg
SAR(1 g) = 10.34 W/kg; SAR(10 g) = 5.38 W/kg
Maximum value of SAR (measured) = 13.2 W/kg




                                                 Page 13 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL Inc.     Date: 2019/10/12

System Check_H1900_1012

DUT: Dipole 1900 MHz D1900V2;SN:5d179;

Communication System: UID 0, CW (0); Frequency: 1900 MHz; Duty Cycle: 1:1
Medium parameters used: f = 1900 MHz; σ = 1.375 S/m; εr = 39.027; ρ = 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:22.5 ℃

DASY Configuration:

    •   Probe: ES3DV3 - SN3162; ConvF(4.9, 4.9, 4.9) @ 1900 MHz; Calibrated: 2019/4/12
    •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 2.0, 32.0
    •   Electronics: DAE3 Sn420; Calibrated: 2019/6/21
    •   Phantom: SAM Front; Type: Twin SAM; Serial: 1896
    •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x7x1): Interpolated grid: dx=15 mm, dy=15 mm
Maximum value of SAR (interpolated) = 14.4 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 113.2 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 18.5 W/kg
SAR(1 g) = 10.3 W/kg; SAR(10 g) = 5.39 W/kg
Maximum value of SAR (measured) = 13.0 W/kg




                                                 Page 14 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                          Date: 2019-10-17

System Check_H2450_1017

DUT: Dipole 2450 MHz D2450V2;SN:919;

Communication System: UID 0, CW (0); Frequency: 2450 MHz; Duty Cycle: 1:1
Medium parameters used (interpolated): f = 2450 MHz; σ = 1.885 S/m; εr = 38.186; ρ = 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:22.4 ℃

DASY Configuration:

   •   Probe: ES3DV3 - SN3162; ConvF(4.5, 4.5, 4.5) @ 2450 MHz; Calibrated: 2019-04-12
   •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 2.0, 32.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Left; Type: Twin SAM; Serial: 1784
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (7x7x1): Interpolated grid: dx=12 mm, dy=12 mm
Maximum value of SAR (interpolated) = 19.7 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 112.0 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 29.0 W/kg
SAR(1 g) = 13.5 W/kg; SAR(10 g) = 6.16 W/kg
Maximum value of SAR (measured) = 17.9 W/kg




                                                Page 15 of 30


                                                          Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL Inc.     Date: 2019/9/29

System Check_H2600_0929

DUT: Dipole 2600 MHz D2600V2;SN:1067;

Communication System: UID 0, CW (0); Frequency: 2600 MHz; Duty Cycle: 1:1
Medium parameters used: f = 2600 MHz; σ = 2.048 S/m; εr = 37.722; ρ = 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:22.1 ℃

DASY Configuration:

    •   Probe: EX3DV4 - SN7544; ConvF(7.4, 7.4, 7.4) @ 2600 MHz; Calibrated: 2019/9/9
    •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 1.0, 31.0
    •   Electronics: DAE4 Sn878; Calibrated: 2018/12/12
    •   Phantom: SAM Front; Type: Twin SAM; Serial: 1896
    •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (7x10x1): Interpolated grid: dx=12 mm, dy=12 mm
Maximum value of SAR (interpolated) = 21.8 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 110.9 V/m; Power Drift = -0.04 dB
Peak SAR (extrapolated) = 30.9 W/kg
SAR(1 g) = 14.2 W/kg; SAR(10 g) = 6.31 W/kg
Maximum value of SAR (measured) = 18.8 W/kg




                                                Page 16 of 30


                                                          Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL Inc.     Date: 2019/10/02

System Check_H2600_1002

DUT: Dipole 2600 MHz D2600V2;SN:1067;

Communication System: UID 0, CW (0); Frequency: 2600 MHz; Duty Cycle: 1:1
Medium parameters used: f = 2600 MHz; σ = 2.051 S/m; εr = 37.628; ρ = 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:22.4 ℃

DASY Configuration:

    •   Probe: EX3DV4 - SN7544; ConvF(7.4, 7.4, 7.4) @ 2600 MHz; Calibrated: 2019/9/9
    •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 1.0, 31.0
    •   Electronics: DAE4 Sn878; Calibrated: 2018/12/12
    •   Phantom: SAM Front; Type: Twin SAM; Serial: 1896
    •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (7x10x1): Interpolated grid: dx=12 mm, dy=12 mm
Maximum value of SAR (interpolated) = 21.7 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 111.7 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 31.2 W/kg
SAR(1 g) = 14.2 W/kg; SAR(10 g) = 6.33 W/kg
Maximum value of SAR (measured) = 18.9 W/kg




                                                 Page 17 of 30


                                                          Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL Inc.     Date: 2019/10/03

System Check_H2600_1003

DUT: Dipole 2600 MHz D2600V2;SN:1067;

Communication System: UID 0, CW (0); Frequency: 2600 MHz; Duty Cycle: 1:1
Medium parameters used: f = 2600 MHz; σ = 2.038 S/m; εr = 37.715; ρ = 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:22.3 ℃

DASY Configuration:

    •   Probe: EX3DV4 - SN7544; ConvF(7.4, 7.4, 7.4) @ 2600 MHz; Calibrated: 2019/9/9
    •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 1.0, 31.0
    •   Electronics: DAE4 Sn878; Calibrated: 2018/12/12
    •   Phantom: SAM Front; Type: Twin SAM; Serial: 1896
    •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (8x10x1): Interpolated grid: dx=12 mm, dy=12 mm
Maximum value of SAR (interpolated) = 22.1 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 112.6 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 31.8 W/kg
SAR(1 g) = 14.5 W/kg; SAR(10 g) = 6.42 W/kg
Maximum value of SAR (measured) = 19.2 W/kg




                                                 Page 18 of 30


                                                          Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL Inc.     Date: 2019/10/9

System Check_H2600_1009

DUT: Dipole 2600 MHz D2600V2;SN:1067;

Communication System: UID 0, CW (0); Frequency: 2600 MHz; Duty Cycle: 1:1
Medium parameters used: f = 2600 MHz; σ = 2.024 S/m; εr = 38.836; ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.5 ℃

DASY Configuration:

    •   Probe: EX3DV4 - SN7544; ConvF(7.4, 7.4, 7.4) @ 2600 MHz; Calibrated: 2019/9/9
    •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 1.0, 31.0
    •   Electronics: DAE4 Sn878; Calibrated: 2018/12/12
    •   Phantom: SAM Front; Type: Twin SAM; Serial: 1896
    •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (8x10x1): Interpolated grid: dx=12 mm, dy=12 mm
Maximum value of SAR (interpolated) = 21.6 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 111.9 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 31.1 W/kg
SAR(1 g) = 14.2 W/kg; SAR(10 g) = 6.31 W/kg
Maximum value of SAR (measured) = 18.8 W/kg




                                                Page 19 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL Inc.     Date: 2019/10/14

System Check_H2600_1014

DUT: Dipole 2600 MHz D2600V2;SN:1067;

Communication System: UID 0, CW (0); Frequency: 2600 MHz; Duty Cycle: 1:1
Medium parameters used: f = 2600 MHz; σ = 2.054 S/m; εr = 37.977; ρ = 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:22.5 ℃

DASY Configuration:

    •   Probe: ES3DV3 - SN3162; ConvF(4.38, 4.38, 4.38) @ 2600 MHz; Calibrated: 2019/4/12
    •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 2.0, 32.0
    •   Electronics: DAE3 Sn420; Calibrated: 2019/6/21
    •   Phantom: SAM Front; Type: Twin SAM; Serial: 1896
    •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (8x10x1): Interpolated grid: dx=12 mm, dy=12 mm
Maximum value of SAR (interpolated) = 22.7 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 113.7 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 32.7 W/kg
SAR(1 g) = 14.71 W/kg; SAR(10 g) = 6.64 W/kg
Maximum value of SAR (measured) = 19.8 W/kg




                                                 Page 20 of 30


                                                          Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL Inc.     Date: 2019/10/17

System Check_H2600_1017

DUT: Dipole 2600 MHz D2600V2;SN:1067;

Communication System: UID 0, CW (0); Frequency: 2600 MHz; Duty Cycle: 1:1
Medium parameters used: f = 2600 MHz; σ = 2.024 S/m; εr = 38.632; ρ = 1000 kg/m3
Ambient Temperature:23.2 ℃; Liquid Temperature:22.4 ℃

DASY Configuration:

    •   Probe: EX3DV4 - SN7544; ConvF(7.4, 7.4, 7.4) @ 2600 MHz; Calibrated: 2019/9/9
    •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 1.0, 31.0
    •   Electronics: DAE4 Sn878; Calibrated: 2018/12/12
    •   Phantom: SAM Front; Type: Twin SAM; Serial: 1896
    •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (7x10x1): Interpolated grid: dx=12 mm, dy=12 mm
Maximum value of SAR (interpolated) = 21.8 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 112.6 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 31.4 W/kg
SAR(1 g) = 14.3 W/kg; SAR(10 g) = 6.35 W/kg
Maximum value of SAR (measured) = 19.0 W/kg




                                                 Page 21 of 30


                                                          Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL Inc.     Date: 2019/10/18

System Check_H2600_1018

DUT: Dipole 2600 MHz D2600V2;SN:1067;

Communication System: UID 0, CW (0); Frequency: 2600 MHz; Duty Cycle: 1:1
Medium parameters used: f = 2600 MHz; σ = 2.049 S/m; εr = 37.739; ρ = 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:22.3 ℃

DASY Configuration:

    •   Probe: EX3DV4 - SN7544; ConvF(7.4, 7.4, 7.4) @ 2600 MHz; Calibrated: 2019/9/9
    •   Sensor-Surface: 4mm (Mechanical Surface Detection), z = 1.0, 31.0
    •   Electronics: DAE4 Sn878; Calibrated: 2018/12/12
    •   Phantom: SAM Front; Type: Twin SAM; Serial: 1896
    •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (7x10x1): Interpolated grid: dx=12 mm, dy=12 mm
Maximum value of SAR (interpolated) = 22.6 W/kg

Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 114.6 V/m; Power Drift = 0.07 dB
Peak SAR (extrapolated) = 31.9 W/kg
SAR(1 g) = 14.68 W/kg; SAR(10 g) = 6.59 W/kg
Maximum value of SAR (measured) = 19.7 W/kg




                                                 Page 22 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                         Date: 2019-10-24

System Check_H5200_1024

DUT: Dipole D5GHzV2;SN;1160;

Communication System: UID 0, CW (0); Frequency: 5200 MHz; Duty Cycle: 1:1
Medium parameters used: f = 5200 MHz; σ = 4.755 S/m; εr = 35.658; ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.4 ℃

DASY Configuration:

   •   Probe: EX3DV4 - SN7544; ConvF(5.54, 5.54, 5.54) @ 5200 MHz; Calibrated: 2019-09-09
   •   Sensor-Surface: 2mm (Mechanical Surface Detection), z = 1.0, 23.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Right v5.0; Type: QD000P40CC; Serial: TP:1469
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x6x1): Interpolated grid: dx=10 mm, dy=10 mm
Maximum value of SAR (interpolated) = 15.9 W/kg

Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 36.02 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 25.8 W/kg
SAR(1 g) = 7.24 W/kg; SAR(10 g) = 2.1 W/kg
Maximum value of SAR (measured) = 16.9 W/kg




                                               Page 23 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                          Date: 2019-10-13

System Check_H5300_1013

DUT: Dipole D5GHzV2;SN;1160;

Communication System: UID 0, CW (0); Frequency: 5300 MHz; Duty Cycle: 1:1
Medium parameters used (interpolated): f = 5300 MHz; σ = 4.815 S/m; εr = 35.945; ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.5 ℃

DASY Configuration:

   •   Probe: EX3DV4 - SN7544; ConvF(5.21, 5.21, 5.21) @ 5300 MHz; Calibrated: 2019-09-09
   •   Sensor-Surface: 2mm (Mechanical Surface Detection), z = 1.0, 23.0
   •   Electronics: DAE4 Sn878; Calibrated: 2018-12-12
   •   Phantom: SAM Left; Type: Twin SAM; Serial: 1784
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x6x1): Interpolated grid: dx=10 mm, dy=10 mm
Maximum value of SAR (interpolated) = 17.0 W/kg

Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 36.37 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 28.7 W/kg
SAR(1 g) = 7.39 W/kg; SAR(10 g) = 2.17 W/kg
Maximum value of SAR (measured) = 17.9 W/kg




                                                Page 24 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                         Date: 2019-10-24

System Check_H5300_1024

DUT: Dipole D5GHzV2;SN;1160;

Communication System: UID 0, CW (0); Frequency: 5300 MHz; Duty Cycle: 1:1
Medium parameters used: f = 5300 MHz; σ = 4.861 S/m; εr = 35.499; ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.4 ℃

DASY Configuration:

   •   Probe: EX3DV4 - SN7544; ConvF(5.21, 5.21, 5.21) @ 5300 MHz; Calibrated: 2019-09-09
   •   Sensor-Surface: 2mm (Mechanical Surface Detection), z = 1.0, 23.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Right v5.0; Type: QD000P40CC; Serial: TP:1469
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x6x1): Interpolated grid: dx=10 mm, dy=10 mm
Maximum value of SAR (interpolated) = 17.1 W/kg

Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 36.35 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 29.0 W/kg
SAR(1 g) = 7.36 W/kg; SAR(10 g) = 2.19 W/kg
Maximum value of SAR (measured) = 18.1 W/kg




                                               Page 25 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                        Date: 2019-10-13

System Check_H5500_1013

DUT: Dipole D5GHzV2;SN;1160;

Communication System: UID 0, CW (0); Frequency: 5500 MHz; Duty Cycle: 1:1
Medium parameters used: f = 5500 MHz; σ = 5.037 S/m; εr = 35.487; ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.5 ℃

DASY Configuration:

   •   Probe: EX3DV4 - SN7544; ConvF(4.95, 4.95, 4.95) @ 5500 MHz; Calibrated: 2019-09-09
   •   Sensor-Surface: 2mm (Mechanical Surface Detection), z = 1.0, 23.0
   •   Electronics: DAE4 Sn878; Calibrated: 2018-12-12
   •   Phantom: SAM Left; Type: Twin SAM; Serial: 1784
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x6x1): Interpolated grid: dx=10 mm, dy=10 mm
Maximum value of SAR (interpolated) = 20.9 W/kg

Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 40.49 V/m; Power Drift = -0.06 dB
Peak SAR (extrapolated) = 36.4 W/kg
SAR(1 g) = 7.99 W/kg; SAR(10 g) = 2.27 W/kg
Maximum value of SAR (measured) = 21.1 W/kg




                                               Page 26 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                         Date: 2019-10-24

System Check_H5500_1024

DUT: Dipole D5GHzV2;SN;1160;

Communication System: UID 0, CW (0); Frequency: 5500 MHz; Duty Cycle: 1:1
Medium parameters used: f = 5500 MHz; σ = 5.083 S/m; εr = 35.182; ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.4 ℃

DASY Configuration:

   •   Probe: EX3DV4 - SN7544; ConvF(4.95, 4.95, 4.95) @ 5500 MHz; Calibrated: 2019-09-09
   •   Sensor-Surface: 2mm (Mechanical Surface Detection), z = 1.0, 23.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Right v5.0; Type: QD000P40CC; Serial: TP:1469
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x6x1): Interpolated grid: dx=10 mm, dy=10 mm
Maximum value of SAR (interpolated) = 21.1 W/kg

Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 40.42 V/m; Power Drift = -0.06 dB
Peak SAR (extrapolated) = 36.9 W/kg
SAR(1 g) = 8.06 W/kg; SAR(10 g) = 2.29 W/kg
Maximum value of SAR (measured) = 21.3 W/kg




                                               Page 27 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                          Date: 2019-10-13

System Check_H5600_1013

DUT: Dipole D5GHzV2;SN;1160;

Communication System: UID 0, CW (0); Frequency: 5600 MHz; Duty Cycle: 1:1
Medium parameters used: f = 5600 MHz; σ = 5.158 S/m; εr = 35.271; ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.5 ℃

DASY Configuration:

   •   Probe: EX3DV4 - SN7544; ConvF(4.81, 4.81, 4.81) @ 5600 MHz; Calibrated: 2019-09-09
   •   Sensor-Surface: 2mm (Mechanical Surface Detection), z = 1.0, 23.0
   •   Electronics: DAE4 Sn878; Calibrated: 2018-12-12
   •   Phantom: SAM Left; Type: Twin SAM; Serial: 1784
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x6x1): Interpolated grid: dx=10 mm, dy=10 mm
Maximum value of SAR (interpolated) = 18.3 W/kg

Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 37.96 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 34.3 W/kg
SAR(1 g) = 7.98 W/kg; SAR(10 g) = 2.32 W/kg
Maximum value of SAR (measured) = 16.3 W/kg




                                               Page 28 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                         Date: 2019-10-24

System Check_H5600_1024

DUT: Dipole D5GHzV2;SN;1160;

Communication System: UID 0, CW (0); Frequency: 5600 MHz; Duty Cycle: 1:1
Medium parameters used: f = 5600 MHz; σ = 5.197 S/m; εr = 35.011; ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.4 ℃

DASY Configuration:

   •   Probe: EX3DV4 - SN7544; ConvF(4.81, 4.81, 4.81) @ 5600 MHz; Calibrated: 2019-09-09
   •   Sensor-Surface: 2mm (Mechanical Surface Detection), z = 1.0, 23.0
   •   Electronics: DAE3 Sn420; Calibrated: 2019-06-21
   •   Phantom: SAM Right v5.0; Type: QD000P40CC; Serial: TP:1469
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x6x1): Interpolated grid: dx=10 mm, dy=10 mm
Maximum value of SAR (interpolated) = 18.5 W/kg

Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 37.93 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 34.6 W/kg
SAR(1 g) = 8.04 W/kg; SAR(10 g) = 2.27 W/kg
Maximum value of SAR (measured) = 16.4 W/kg




                                               Page 29 of 30


                                                         Report No.: BTL-FCC SAR-1-1909C106_Appendix A.


Test Laboratory: BTL.Inc                         Date: 2019-10-14

System Check_H5800_1014

DUT: Dipole D5GHzV2;SN;1160;

Communication System: UID 0, CW (0); Frequency: 5800 MHz; Duty Cycle: 1:1
Medium parameters used: f = 5800 MHz; σ = 5.411 S/m; εr = 34.839; ρ = 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.5 ℃

DASY Configuration:

   •   Probe: EX3DV4 - SN7544; ConvF(4.75, 4.75, 4.75) @ 5800 MHz; Calibrated: 2019-09-09
   •   Sensor-Surface: 2mm (Mechanical Surface Detection), z = 1.0, 23.0
   •   Electronics: DAE4 Sn878; Calibrated: 2018-12-12
   •   Phantom: SAM Left; Type: Twin SAM; Serial: 1784
   •   DASY52 52.10.2(1495); SEMCAD X 14.6.12(7450)


Area Scan (6x6x1): Interpolated grid: dx=10 mm, dy=10 mm
Maximum value of SAR (interpolated) = 18.6 W/kg

Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm, dz=2mm
Reference Value = 35.32 V/m; Power Drift = -0.05 dB
Peak SAR (extrapolated) = 35.8 W/kg
SAR(1 g) = 7.78 W/kg; SAR(10 g) = 2.25 W/kg
Maximum value of SAR (measured) = 15.9 W/kg




                                               Page 30 of 30



Document Created: 2019-10-29 09:15:49