Test Report_DXX

FCC ID: R9C-CPH1941

Test Report

Download: PDF
FCCID_4496171

                                                            Report No.: BTL-FCCP-1-1909C106




                  FCC Radio Test Report
                       FCC ID: R9C-CPH1941
                         This report concerns: Original Grant

Project No.        :   1909C106
Equipment          :   Mobile Phone
Brand Name         :   OPPO
Test Model         :   CPH1941
Series Model       :   N/A
Applicant          :   GuangDong Oppo Mobile Telecommunications Corp., Ltd.
Address            :   NO. 18 HaiBin Road, WuSha village, Chang An Town,
                       DongGuan City,Guangdong,China.
Manufacturer       :   GuangDong Oppo Mobile Telecommunications Corp., Ltd.
Address            :   NO. 18 HaiBin Road, WuSha village, Chang An Town,
                       DongGuan City,Guangdong,China.
Factory            :   GuangDong Oppo Mobile Telecommunications Corp., Ltd.
Address            :   NO. 18 HaiBin Road, WuSha village, Chang An Town,
                       DongGuan City,Guangdong,China.
Date of Receipt    :   Sep. 19, 2019
Date of Test       :   Sep. 19, 2019 ~ Sep. 25, 2019
Issued Date        :   Oct. 24, 2019
Report Version     :   R00
Test Sample        :   Engineering Sample No.: DG20190920152
Standard(s)        :   FCC Part 15, Subpart C (15.225)
                       ANSI C63.10-2013


The above equipment has been tested and found compliance with the requirement of
the relative standards by BTL Inc.




   Prepared by : Vincent Tan



    Approved by : Ethan Ma


Add: No.3, Jinshagang 1st Road, Shixia, Dalang Town,Dongguan, Guangdong, China.
Tel: +86-769-8318-3000
Web: www.newbtl.com


                                     Page 1 of 32


                                                                               Report No.: BTL-FCCP-1-1909C106



Declaration
BTL represents to the client that testing is done in accordance with standard procedures as applicable and
that test instruments used has been calibrated with standards traceable to international standard(s) and/or
national standard(s).
BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility
to ensure that additional production units of this model are manufactured with the identical electrical and
mechanical components. BTL shall have no liability for any declarations, inferences or generalizations
drawn by the client or others from BTL issued reports.
The report must not be used by the client to claim product certification, approval, or endorsement by
NVLAP, NIST, A2LA, or any agency of the U.S. Government.
This report is the confidential property of the client. As a mutual protection to the clients, the public and
ourselves, the test report shall not be reproduced, except in full, without our written approval.
BTL’s laboratory quality assurance procedures are in compliance with the ISO/IEC 17025 requirements,
and accredited by the conformity assessment authorities listed in this test report.
BTL is not responsible for the sampling stage, so the results only apply to the sample as received.
The information, data and test plan are provided by manufacturer which may affect the validity of results,
so it is manufacturer’s responsibility to ensure that the apparatus meets the essential requirements of
applied standards and in all the possible configurations as representative of its intended use.
Limitation
For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this
test report is (are) included in the conformity assessment authorities acceptance respective.
Please note that the measurement uncertainty is provided for informational purpose only and are not use
in determining the Pass/Fail results.




                                                 Page 2 of 32


                                                 Report No.: BTL-FCCP-1-1909C106



                        Table of Contents                          Page


REPORT ISSUED HISTORY                                                5
1 . SUMMARY OF TEST RESULTS                                          6
  1.1 TEST FACILITY                                                  7
  1.2 MEASUREMENT UNCERTAINTY                                        7
  1.3 TEST ENVIRONMENT CONDITIONS                                    7
2 . GENERAL INFORMATION                                              8
  2.1 GENERAL DESCRIPTION OF EUT                                     8
  2.2 DESCRIPTION OF TEST MODES                                      9
  2.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10
  2.4 SUPPORT UNITS                                                 10
3 . AC POWER LINE CONDUCTED EMISSIONS TEST                         11
  3.1 LIMIT                                                         11
  3.2 TEST PROCEDURE                                                11
  3.3 DEVIATION FROM TEST STANDARD                                  11
  3.4 TEST SETUP                                                    12
  3.5 EUT OPERATING CONDITIONS                                      12
  3.6 TEST RESULTS                                                  12
4 . RADIATED EMISSION TEST                                         13
  4.1 LIMIT                                                         13
  4.2 TEST PROCEDURE                                                14
  4.3 DEVIATION FROM TEST STANDARD                                  14
  4.4 TEST SETUP                                                    15
  4.5 EUT OPERATING CONDITIONS                                      15
  4.6 TEST RESULTS - 9 KHZ TO 30 MHZ                                15
  4.7 TEST RESULTS - 30 MHZ TO 1000 MHZ                             15
5 . FREQUENCY TOLERANCE TEST                                       16
  5.1 LIMIT                                                         16
  5.2 TEST PROCEDURE                                                16
  5.3 DEVIATION FROM STANDARD                                       16
  5.4 TEST SETUP                                                    16
  5.5 EUT OPERATION CONDITIONS                                      16
  5.6 TEST RESULTS                                                  16
6 . MEASUREMENT INSTRUMENTS LIST                                   17




                                  Page 3 of 32


                                                 Report No.: BTL-FCCP-1-1909C106


                      Table of Contents                            Page


APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS                     18
APPENDIX B - RADIATED EMISSION - 9 KHZ-30 MHZ                      21
APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ                28
APPENDIX D - FREQUENCY TOLERANCE                                   31




                               Page 4 of 32


                                              Report No.: BTL-FCCP-1-1909C106



                 REPORT ISSUED HISTORY

Report Version                Description                   Issued Date
     R00                    Original Issue.                 Oct. 24, 2019




                       Page 5 of 32


                                                                          Report No.: BTL-FCCP-1-1909C106



1. SUMMARY OF TEST RESULTS

Test procedures according to the technical standard(s):


                                FCC Part15, Subpart C (15.225)
        Standard(s) Section              Test Item           Test Result      Judgment    Remark
                                  AC Power Line Conducted
               15.207                                        APPENDIX A         PASS       ------
                                        Emissions
             15.205(a)
                                                             APPENDIX B
             15.209(a)               Radiated Emission                          PASS       ------
                                                             APPENDIX C
            15.225(a)-(d)
             15.225(e)              Frequency Tolerance      APPENDIX D         PASS       ------

               15.203               Antenna Requirement          ------         PASS      Note(2)

Note:
        (1) “N/A” denotes test is not applicable in this test report
        (2) The device what use a permanently attached antenna were considered sufficient to
            comply with the provisions of 15.203.




                                             Page 6 of 32


                                                                          Report No.: BTL-FCCP-1-1909C106



1.1 TEST FACILITY
  The test facilities used to collect the test data in this report is at the location of No.3, Jinshagang
 1st Road, Shixia, Dalang Town, Dongguan, Guangdong, China
  BTL's Test Firm Registration Number for FCC: 357015
  BTL's Designation Number for FCC: CN1240

1.2 MEASUREMENT UNCERTAINTY
 ISO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the
 emissions test results be included in the report. The measurement uncertainties given below
 are based on a 95% confidence level (based on a coverage factor (k=2))
 The BTL measurement uncertainty as below table:

 A. AC power line conducted emissions test:

                Test Site    Method       Measurement Frequency Range             U, (dB)
                DG-C02       CISPR             150 kHz ~ 30 MHz                    2.32

 B. Radiated emissions test:

                                         Measurement Frequency            Ant.
                Test Site    Method                                               U, (dB)
                                                Range                     H/V
                                             9kHz ~ 30MHz                  V        3.79
                                             9kHz ~ 30MHz                  H        3.57
                                           30MHz ~ 200MHz                  V        4.88
                                           30MHz ~ 200MHz                  H        4.14
                                          200MHz ~ 1,000MHz                V        4.62
                DG-CB03      CISPR
                                          200MHz ~ 1,000MHz                H        4.80
                                             1GHz ~ 6GHz                   -        4.58
                                            6GHz ~ 18GHz                   -        5.18
                                           18GHz ~ 26.5GHz                 -        3.80
                                           26.5GHz ~ 40GHz                 -        4.30

 Note: Unless specifically mentioned, the uncertainty of measurement has not been taken into
 account to declare the compliance or non-compliance to the specification.

1.3 TEST ENVIRONMENT CONDITIONS

             Test Item            Temperature Humidity Test Voltage  Tested By
AC Power Line Conducted Emissions    25°C      60% AC 120V/60Hz Damon Deng
  Radiated Emissions-9K-30MHz        25°C      60% AC 120V/60Hz Sheldon Ou
Radiated Emissions-30 MHz to 1GHz    25°C      60% AC 120V/60Hz Sheldon Ou
       Frequency Tolerance                 Normal, Extreme          Robin Zhuang




                                              Page 7 of 32


                                                                       Report No.: BTL-FCCP-1-1909C106



2. GENERAL INFORMATION

2.1 GENERAL DESCRIPTION OF EUT

  Equipment                    Mobile Phone
  Brand Name                   OPPO
  Test Model                   CPH1941
  Series Model                 N/A
  Model Difference(s)          N/A
  Hardware Version             11
  Software Version             ColorOS V6.0.1
  Firmware Version             TBD
  Operation Frequency          13.56 MHz
  Antenna Type                 Loop Antenna
                               1. DC Voltage supplied from AC/DC adapter.
                                  1# Model: OP52KAUH
                                  2# Model: OP52JAUH
                                  3# Model: OP52YAUH
                               2. Supplied from Li-ion Polymer battery.
  Power Source                    1# Factory / Model: NVT / BLP727 (NA-P727-92)
                                  2# Factory / Model: Desay / BLP727 (DA-P727-923)
                                  3# Factory / Model: Sunwoda / BLP727 (XA-P727-922)
                                  4# Factory / Model: Desay / BLP727 (DD-P727-918)
                                  5# Factory / Model: Desay / BLP727 (DA-P727-931)
                               3. Supplied from USB port.
                               1. I/P:100-240V~ 50/60Hz 0.4A O/P:5V − − − 2A
  Power Rating                 2. 3.87Vdc, 5000mAh/19.35Wh
                               3. DC 5V
Note:
 1. For a more detailed features description, please refer to the manufacturer’s specifications or the
    user's manual.




                                             Page 8 of 32


                                                                   Report No.: BTL-FCCP-1-1909C106



2.2 DESCRIPTION OF TEST MODES


 The test system was pre-tested based on the consideration of all possible combinations of
 EUT operation mode.

          Pretest Mode                               Description
             Mode 1                             TX Mode_13.56MHz

 Following mode(s) was (were) found to be the worst case(s) and selected for the final test.

                           AC power line conducted emissions test

         Final Test Mode                             Description
             Mode 1                             TX Mode_13.56MHz


                            Radiated emissions test - Below 1GHz

         Final Test Mode                             Description
             Mode 1                             TX Mode_13.56MHz


                                        Conducted test

         Final Test Mode                             Description
             Mode 1                             TX Mode_13.56MHz

 Note:
 For radiated emissions below 1GHz, all adapters had been pre-tested and in this report only
 recorded the worst case.




                                          Page 9 of 32


                                                               Report No.: BTL-FCCP-1-1909C106



2.3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED




2.4 SUPPORT UNITS

Item   Equipment       Mfr/Brand              Model/Type No.              Series No.
 A      NFC Card          N/A                      N/A                       N/A


Item   Cable Type     Shielded Type            Ferrite Core                Length
 1      DC Cable          NO                       NO                        1m




                                   Page 10 of 32


                                                                        Report No.: BTL-FCCP-1-1909C106



3. AC POWER LINE CONDUCTED EMISSIONS TEST

 3.1 LIMIT

                                                              Limit (dBμV)
  Frequency of Emission (MHz)
                                               Quasi-peak                     Average
             0.15 - 0.50                         66 to 56*                    56 to 46*
             0.50 - 5.0                              56                           46
             5.0 - 30.0                              60                           50
 Note:
(1) The tighter limit applies at the band edges.
(2) The limit of " * " marked band means the limitation decreases linearly with the logarithm of the
    frequency in the range.

The following table is the setting of the receiver
              Receiver Parameters                                       Setting
                   Attenuation                                           10 dB
                 Start Frequency                                       0.15 MHz
                 Stop Frequency                                         30 MHz
                  IF Bandwidth                                           9 kHz

 3.2 TEST PROCEDURE
 a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
    to the power mains through a line impedance stabilization network (LISN). All other support
    equipment powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
    impedance for the measuring instrument.
 b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
    and forth in the center forming a bundle 30 to 40 cm long.
 c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
    cable may be terminated, if required, using the correct terminating impedance. The overall
    length shall not exceed 1 m.
 d. LISN at least 80 cm from nearest part of EUT chassis.
 e. For the actual test configuration, please refer to the related Item –EUT Test Photos.

3.3 DEVIATION FROM TEST STANDARD
No deviation




                                              Page 11 of 32


                                                                               Report No.: BTL-FCCP-1-1909C106



 3.4 TEST SETUP


                     Vertical Reference Ground Plane




             40 cm           EUT                                          Test Receiver



                                                       80 cm

             LISN


                                           Horizontal Reference Ground Plane




 3.5 EUT OPERATING CONDITIONS
The EUT was configured for testing in a typical function (as a customer would normally use it),
EUT was programmed to be in continuously transmitting data or hopping on mode.

 3.6 TEST RESULTS
Please refer to the APPENDIX A.

Remark:
    (1) All readings are QP Mode value unless otherwise stated AVG in column of『Note』 . If the QP
        Mode Measured value compliance with the QP Limits and lower than AVG Limits, the EUT
        shall be deemed to meet both QP & AVG Limits and then only QP Mode was measured,
        but AVG Mode didn‘t perform in this case, a “*” marked in AVG Mode column of Interference
        Voltage Measured.
    (2) Measuring frequency range from 150 kHz to 30 MHz.




                                                Page 12 of 32


                                                                     Report No.: BTL-FCCP-1-1909C106



4. RADIATED EMISSION TEST

4.1 LIMIT

Clause 15.225(a) the field strength of any emissions within the band 13.553-13.567 MHz shall not
exceed 15,848 microvolts/meter at 30 meters.
Clause 15.225(b) within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of
any emissions shall not exceed 334 microvolts/meter at 30 meters.
Clause 15.225(c) within the bands 13.110-13.410 MHz and 13.710-14.010 MHz the field strength of
any emissions shall not exceed 106 microvolts/meter at 30 meters.
Clause 15.225(d) The field strength of any emissions appearing outside of the 13.110-14.010 MHz
band shall not exceed the general radiated emission limits in §15.209.
§15.209 (a) Except as provided elsewhere in this subpart, the emissions from an intentional radiator
shall not exceed the field strength levels specified in the following table:

LIMITS OF RADIATED EMISSION MEASUREMENT (9 kHz-1000 MHz)

            Frequency                    Field Strength              Measurement Distance
             (MHz)                     (microvolts/meter)                    (meters)
          0.009-0.490                     2400/F(kHz)                          300
          0.490-1.705                    24000/F(kHz)                           30
           1.705-30.0                          30                               30
              30-88                           100                                3
             88-216                           150                                3
            216-960                           200                                3
           Above 960                          500                                3

Note:
   (1) The limit for radiated test was performed according to FCC PART 15C.
   (2) The tighter limit applies at the band edges.
   (3) Emission level (dBuV/m)=20log Emission level (uV/m).




                                           Page 13 of 32


                                                                      Report No.: BTL-FCCP-1-1909C106



4.2 TEST PROCEDURE

The test set-up was made in accordance to the general provisions of ANSI C63.10-2013.The
Equipment Under Test (EUT) was set up on a non-conductive table in the semi-anechoic chamber.
The test was performed at the distance of 3 m between the EUT and the receiving antenna. The
radiated emissions measurements were made in a typical installation configuration.
Sweep the whole frequency band through the range from 9 kHz to the 10th harmonic of the carrier,
and the emissions less than 20 dB below the permissible value are reported.

During the test, below 30MHz, the center of the loop shall be 1 meters; above 30MHz, the height of
receive antenna shall be moved from 1 to 4 meters, and the antenna shall be performed under
horizontal and vertical polarization. The turntable shall be rotated from 0 to 360 degrees for
detecting the maximum of radiated spurious signal level. The measurements shall be repeated with
orthogonal polarization of the test antenna. The data of cable loss and antenna factor has been
calibrated in full testing frequency range before the testing.
Set the spectrum analyzer in the following:
Below 1GHz (detector: Peak and Quasi-Peak)
RBW=100 kHz / VBW=300 kHz / Sweep=AUTO

The radiated emission was measured in the following position: EUT stand-up position (Z axis),
lie-down position (X, Y axis). The worst emission was found in stand-up position (Z axis) and the
worst case was recorded.

4.3 DEVIATION FROM TEST STANDARD
No deviation




                                           Page 14 of 32


                                                                       Report No.: BTL-FCCP-1-1909C106



4.4 TEST SETUP

                                          9 kHz-30 MHz




                                      30 MHz to 1000 MHz
                                        Absorbers



                                                                             1-4 m

                                          3m


                     EUT
                                                                            1m
           0.8 m


                                      Ground Plane




                                                            Receiver        Amp.



4.5 EUT OPERATING CONDITIONS
The EUT was programmed to be in continuously transmitting mode.

4.6 TEST RESULTS - 9 kHz TO 30 MHz
Please refer to the APPENDIX B

 Remark:
     (1) Distance extrapolation factor = 40 log (specific distance / test distance) (dB).
     (2) Limit line = specific limits (dBuV) + distance extrapolation factor.

4.7 TEST RESULTS - 30 MHz TO 1000 MHz
Please refer to the APPENDIX C.



                                            Page 15 of 32


                                                                     Report No.: BTL-FCCP-1-1909C106



5. FREQUENCY TOLERANCE TEST

5.1 LIMIT
                                    FCC Part15 Subpart C
       Section                            Test Item                             Limit
      15.225(e)                     Frequency Tolerance                      ±0.001MHz

5.2 TEST PROCEDURE

 1. The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the
    operating frequency over a temperature variation of −20 degrees to + 50 degrees C at
    normal supply voltage, and for a variation in the primary supply voltage from 85% to 115%
    of the rated supply voltage at a temperature of 20 degrees C. For battery operated
    equipment, the equipment tests shall be performed using a new battery.

5.3 DEVIATION FROM STANDARD
No deviation.

5.4 TEST SETUP




 5.5 EUT OPERATION CONDITIONS
The EUT tested system was configured as the statements of 3.5 unless otherwise a special
operating condition is specified in the follows during the testing.

5.6 TEST RESULTS
Please refer to the APPENDIX D.




                                           Page 16 of 32


                                                                     Report No.: BTL-FCCP-1-1909C106



6. MEASUREMENT INSTRUMENTS LIST

                             AC Power Line Conducted Emissions
Item Kind of Equipment      Manufacturer    Type No.        Serial No.            Calibrated until
  1 EMI Test Receiver          R&S            ESCI           100382               Mar. 10, 2020
  2        LISN               EMCO           3816/2           52765               Mar. 10, 2020
        TWO-LINE
  3                             R&S              ENV216              101447       May. 19, 2020
       V-NETWORK
  4   50Ω Terminator            SHX               TF5-3            15041305       Mar. 10, 2020
       Measurement                               EZ-EMC
  5                            Farad                                  N/A              N/A
         Software                            Ver.NB-03A1-01
  6        Cable                 N/A             RG223                12m         Mar. 12, 2020

                             Radiated Emissions - 9 kHz to 30 MHz
Item Kind of Equipment      Manufacturer      Type No.         Serial No.         Calibrated until
  1    Loop Antenna             EM          EM-6876-1             230             Jan. 15, 2020
  2        Cable                N/A           RG 213/U           C-102            May 31, 2020
  3 EMI Test Receiver          R&S              ESCI            100895            Mar. 10, 2020
       Measurement                            EZ-EMC
  4                            Farad                              N/A                  N/A
         Software                         Ver.NB-03A1-01

                             Radiated Emissions - 30 MHz to 1 GHz
Item Kind of Equipment      Manufacturer      Type No.         Serial No.         Calibrated until
  1       Antenna           Schwarzbeck      VULB9160          9160-3232          Mar. 09, 2020
  2*      Amplifier              HP            8447D          2944A09673          Aug. 11, 2021
  3      Receiver              Agilent        N9038A         MY52130039           Aug. 03, 2020
                                         LMR-400(30MHz-
  4         Cable               emci                              N/A             May 24, 2020
                                          1GHz)(8m+5m)
  5      Controller              CT            SC100              N/A                  N/A
  6      Controller              MF           MF-7802        MF780208416               N/A
        Measurement                           EZ-EMC
  7                            Farad                              N/A                  N/A
         Software                         Ver.NB-03A1-01

                                     Frequency Tolerance
Item Kind of Equipment      Manufacturer     Type No.              Serial No.     Calibrated until
  1 Spectrum Analyzer          R&S            FSP40                 100185        Aug. 03, 2020
      Precision Oven
  2                              Bell           BTH-50C          20170306001      Mar. 10, 2020
           Tester

Remark “N/A” denotes no model name, serial no. or calibration specified.
       “*” calibration period of equipment list is three year.
       Except * item, all calibration period of equipment list is one year.




                                           Page 17 of 32


                                  Report No.: BTL-FCCP-1-1909C106




APPENDIX A - AC POWER LINE CONDUCTED EMISSIONS




                  Page 18 of 32


                                                          Report No.: BTL-FCCP-1-1909C106



Test Mode        TX Mode_13.56MHz

                                           Line




REMARKS:
(1) Measurement Value = Reading Level + Correct Factor.
(2) Margin Level = Measurement Value - Limit Value.




                                         Page 19 of 32


                                                          Report No.: BTL-FCCP-1-1909C106



Test Mode        TX Mode_13.56MHz

                                          Neutral




REMARKS:
(1) Measurement Value = Reading Level + Correct Factor.
(2) Margin Level = Measurement Value - Limit Value.




                                         Page 20 of 32


                                  Report No.: BTL-FCCP-1-1909C106




APPENDIX B - RADIATED EMISSION - 9 KHZ-30 MHZ




                  Page 21 of 32


                                                          Report No.: BTL-FCCP-1-1909C106



Test Mode        TX Mode_13.56MHz

                                          Ant 0°




REMARKS:
(1) Measurement Value = Reading Level + Correct Factor.
(2) Margin Level = Measurement Value - Limit Value.




                                         Page 22 of 32


                                                          Report No.: BTL-FCCP-1-1909C106



Test Mode        TX Mode_13.56MHz

                                          Ant 90°




REMARKS:
(1) Measurement Value = Reading Level + Correct Factor.
(2) Margin Level = Measurement Value - Limit Value.




                                         Page 23 of 32


                                                          Report No.: BTL-FCCP-1-1909C106



Test Mode        TX Mode_13.56MHz

                                          Ant 0°




REMARKS:
(1) Measurement Value = Reading Level + Correct Factor.
(2) Margin Level = Measurement Value - Limit Value.




                                         Page 24 of 32


                                                          Report No.: BTL-FCCP-1-1909C106



Test Mode        TX Mode_13.56MHz

                                          Ant 0°




REMARKS:
(1) Measurement Value = Reading Level + Correct Factor.
(2) Margin Level = Measurement Value - Limit Value.




                                         Page 25 of 32


                                                          Report No.: BTL-FCCP-1-1909C106




Test Mode        TX Mode_13.56MHz

                                          Ant 90°




REMARKS:
(1) Measurement Value = Reading Level + Correct Factor.
(2) Margin Level = Measurement Value - Limit Value.




                                         Page 26 of 32


                                                          Report No.: BTL-FCCP-1-1909C106




Test Mode        TX Mode

                                          Ant 90°




REMARKS:
(1) Measurement Value = Reading Level + Correct Factor.
(2) Margin Level = Measurement Value - Limit Value.




                                         Page 27 of 32


                                     Report No.: BTL-FCCP-1-1909C106




APPENDIX C - RADIATED EMISSION - 30 MHZ TO 1000 MHZ




                     Page 28 of 32


                                                          Report No.: BTL-FCCP-1-1909C106



Test Mode        TX Mode_13.56MHz

                                          Vertical




REMARKS:
(1) Measurement Value = Reading Level + Correct Factor.
(2) Margin Level = Measurement Value - Limit Value.




                                         Page 29 of 32


                                                          Report No.: BTL-FCCP-1-1909C106



Test Mode        TX Mode_13.56MHz

                                        Horizontal




REMARKS:
(1) Measurement Value = Reading Level + Correct Factor.
(2) Margin Level = Measurement Value - Limit Value.




                                         Page 30 of 32


                            Report No.: BTL-FCCP-1-1909C106




APPENDIX D - FREQUENCY TOLERANCE




            Page 31 of 32


                                                                       Report No.: BTL-FCCP-1-1909C106



Test Mode               TX Mode_13.56MHz

                         Frequency Tolerance Versus Environmental Temperature
                                                          Frequency
              Temperature       Voltage    Frequency                        Limit
                                                             Error                     Result
                 (°C)             (V)        (MHz)                          (kHz)
                                                            (kHz)
                  25             3.87         13.56             -              -         -
 0 min            50             3.87        13.562             2          +/- 1.356   PASS
                  -20            3.87        13.5605          0.5          +/- 1.356   PASS
 2 min            50             3.87        13.5605          0.5          +/- 1.356   PASS
                  -20            3.87        13.5603          0.3          +/- 1.356   PASS
 5 min            50             3.87        13.5606          0.6          +/- 1.356   PASS
                  -20            3.87        13.5597          -0.3         +/- 1.356   PASS
10 min            50             3.87        13.5604          0.4          +/- 1.356   PASS
                  -20            3.87        13.5595          -0.5         +/- 1.356   PASS
                                Frequency Tolerance Versus Input Voltage
                                                          Frequency
  Temperature               Voltage        Frequency                        Limit
                                                             Error                     Result
     (°C)                     (V)            (MHz)                          (kHz)
                                                            (kHz)
         25             V-nom     3.87        13.56             -              -         -
         25             V-min    3.2895      13.5606          0.6          +/- 1.356   PASS
         25             V-max    4.4505      13.5606          0.6          +/- 1.356   PASS




                                           End of Test Report

                                              Page 32 of 32



Document Created: 2019-11-02 02:52:10
Document Modified: 2019-11-02 02:52:10

© 2024 FCC.report