RF EXPOSURE

FCC ID: R7PTOP04

RF Exposure Info

Download: PDF
FCCID_611784

               FCC Part 15 Subpart C
              Transmitter Certification
Frequency Hopping Spread Spectrum Transmitter

                        FCC ID: R7PTOP04

                      FCC Rule Part: 15.247

           ACS Report Number: 05-0327-15C

          Manufacturer: Cellnet Technology, Inc.
             Model: Take Out Point (TOP)




          RF Exposure Information




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: Take Out Point (TOP)               Advanced Compliance Solutions                   FCC ID: R7PTOP04


General Information:

Applicant:               Cellnet
ACS Project:             05-0327
FCC ID:                  R7PTOP04
Device Category:         Fixed
Environment:             General Population/Uncontrolled Exposure

Technical Information:

Antenna Type: Whip
Antenna Gain: 5dBi
Transmitter Conducted Power: 29.75dBm
Maximum System EIRP: 34.75dBm
Operating Configuration: Fixed mounted
Exposure Conditions: Greater than 20 centimeters
Antenna Separation (Co-location): Greater than 20 centimeters

MPE Calculation

The Power Density (mW/cm2) is calculated as follows:

      PG
S=
     4πR 2
Where:

S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                                MPE Calculator for Mobile Equipment
                       Limits for General Population/Uncontrolled Exposure*

Transmit      Radio          Power          Radio      Antenna      Antenna
                                                                                                 Power
  Freq.       Power         Density         Power       Gain          Gain       Distance
                                                                                                 Density
 (MHz)        (dBm)          Limit          (mW)        (dBi)       (mW eq.)       (cm)
                                                                                               (mW/cm^2)
                           (mW/Cm2)

   903         29.75           0.60         944.06        5.00        3.162          20          0.594

Installation Guidelines
The installation manual contains the following text advising how to install the equipment to maintain
compliance with the FCC RF exposure requirements:

“RF Exposure (Intentional Radiators Only)
In accordance with FCC requirements of human exposure to radiofrequency fields, the radiating element
shall be installed such that a minimum separation distance of 20cm is maintained from the general
population.”

Conclusion
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.


ACS Report: 05-0327-15C                                                                          Page 2