                               Manual




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Gridstream
Series IV IWR Radio
Data Sheet

General
                 The Gridstream Series IV Integrated WanGate Radio (IWR) provides a basis for a powerful RF
                 wireless mesh network for remote data collection. The radio provides full two-way peer-to-peer
                 communication to all devices within the network. The Gridstream Series IV IWR also offers
                 advanced functionality, such as individual message prioritization, additional memory for localized
                 intelligence, and a programming language Device Control Word (DCW) used to provide interface
                 and control to distributed automation equipment.
                 The Gridstream Series IV IWR has one RS-232 serial port for the LAN Packet Port (LPP) and one
                 RS-232/485 serial port for the Transparent Packet Port (TPP). The LAN Packet Protocol Port is used
                 to communicate to devices that use the Gridstream IWR LAN Packet Protocol, such as a PC with
                 configuration or diagnostic software. The Transparent Packet Port is a general-purpose data port that
                 is used to transport byte-oriented data, such as DNP 3.0, Modbus, or DF1.




                                              Figure 1. Gridstream Series IV IWR Radio



Landis+Gyr Confidential Information               98-0064 Rev AB                                                      1


Gridstream Series IV IWR Radio Data Sheet                                                              Landis+Gyr


Gridstream Series IV IWR Radio Usage
                 The Gridstream Series IV IWR Radio, P/N 26-1309, was engineered specifically for varied
                 needs of residential and commercial applications. It enables access to the RF mesh network
                 using a standard RS-232 connection.
                 Useful features of the Gridstream Series IV IWR Radio include:
                 •   User-friendly interface via RadioShop for configuring the Gridstream Series IV IWR Radio. The
                     interface provides:
                     •   Current status information
                     •   Logical configurations for:
                         •   LPP port
                         •   TPP port
                 •   Simultaneous connections per RS-232 interface by:
                     •   LPP applications
                     •   TPP applications




2                                                98-0064 Rev AB               Landis+Gyr Confidential Information


Landis+Gyr                                                               Gridstream Series IV IWR Radio Data Sheet


Regulatory Compliance
FCC (Part 15.247)
                 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
                 conditions:
                 1. This device may not cause harmful interference, and
                 2. This device must accept any interference received, including interference that may cause
                    undesired operation.

                              Changes or modifications not expressly approved by Landis+Gyr for compliance
                              could void the user’s authority to operate the equipment.



FCC Class B

                                 This equipment has been tested and found to comply with the limits for
                                 Class B digital service, pursuant to Part 15 of the FCC Rules. These
                                 limits are designed to provide reasonable protection against harmful
                                 interference in a residental installation. This equipment generates, uses,
                                 and can radiate radio frequency energy and, if not installed and used in
                                 accordance with the instructions, may cause harmful interference to
                                 radio communications. However, there is no guarantee that interference
                                 will not occur in a particular installation. If this equipment does cause
                                 harmful interference to radio or television reception, which can be
                                 determined by turning the equipment off and on, the user is
                                 encouraged to try to connect the interference by one or more of the
                                 following measures:
                                 •    Reorient or relocate the receiving antenna
                                 •    Increase the separation between the equipment and receiver
                                 •    Connect the equipment into an outlet on a circuit different from that
                                      to which the receiver is connected.
                                 •    Consult the dealer or an experienced radio/TV technican for help


RF Exposure
                 The equipment complies with FCC radiation exposure limits set forth for an uncontrolled
                 environment. This equipment should be installed and operated with minimum distance 22cm
                 between the radiator and your body. This transmitter must not be co-located or operating in
                 conjunction with any other antenna or transmitter.




Landis+Gyr Confidential Information              98-0064 Rev AB                                                  3


Gridstream Series IV IWR Radio Data Sheet                                                                                     Landis+Gyr


Gridstream Series IV IWR Radio Specifications

                                             Table 1. General Series IV IWR Specification
    Electrical (General)
    Input Voltage Range                        6 - 28 VDC
    Input Current (in transmitting mode)       320 mA typical (12 VDC operation)
    Input Current (in receiving mode)          38 mA typical (12 VDC operation)
    RF Frequency Range                         902-928 MHz
    Channel Spacing                            100 kHz, 300 kHz (depending on mode)
    RF Data Rate                               9.6-38.4 Kbps (100 kHz channels), 9.6-115.2 Kbps (300 kHz channels)

    Receiver
    Sensitivity (at 10% packet error rate)     -112 dBm (9.6 Kbps), -102 dBm (115.2 Kbps) typical
    Co-channel rejection                       10 dB Typical
    Adjacent Channel Rejection                 30 dB Typical
    Alternate Channel Rejection                45 dB Typical

    Transmitter
    Output Power (at Antenna Connector)        126 mW (21 dBm)/316 mW (25 dBm)/1 Watt (30 dBm)
    Modulation Type                            2-FSK, GFSK
    Modulation Index                           1
    Out-of-band Spurious Emissions             <-70 dBc

    Antenna Requirements
    Type                                       Vertically polarized, omnidirectional
    Gain                                       < 5 dBi

    Processing
    CPU                                        M16C/65P
    Clock Speed                                14.7456 MHz
    SRAM Memory                                47 kbytes internal + 512 kbytes external
    FLASH Memory                               768 kbytes internal + 1 Mbytes external




    Data Ports/Formats

                                               LAN Packet Port                            Transparent Port
    Serial Interface                           RS-232C; DB9 female; 1200 to               RS-232C/RS-485; DB9 Female; 300 to 38,400 bps
                                               115,200 bps
    Protocol                                   Gridstream LAN Packet Protocol             Any Asynchronous Byte-Oriented Protocol
    Parity                                     None                                       None
    Data Bits                                  8                                          7 or 8
    Stop Bits                                  1                                          1 or 2
    Duplex                                     Full                                       Full




4                                                             98-0064 Rev AB                        Landis+Gyr Confidential Information


Landis+Gyr                                                                     Gridstream Series IV IWR Radio Data Sheet


                                Table 1. General Series IV IWR Specification(Continued)
  Mechanical
  Enclosure                              Extruded Aluminum
  Power Connection                       Molex Mini-fit
  Dimensions                             4.250” W x 5.770” D x 1.720” H
  Weight                                 1.10 lbs
  Antenna                                SMA Type, Female
  Operating Temperature Range            -40° to 85° C
  Storage Temperature Range              -40° to 85° C




                                Technical Support:         Internet:                 E-mail:
Contact Information:            1.888.390.5733             www.landisgyr.com         solutionsupport.na@landisgyr.com




Landis+Gyr Confidential Information                    98-0064 Rev AB                                                   5


Gridstream Series IV IWR Radio Data Sheet                                           Landis+Gyr




6                                           98-0064 Rev AB   Landis+Gyr Confidential Information