Manual

FCC ID: R7PER6R1S2

Users Manual

Download: PDF
FCCID_2655626

                   Certification Exhibit



                     FCC ID: R7PER6R1S2

               FCC Rule Part: 15.247, 15.249


               ACS Project Number: 15-0174

      Manufacturer: Landis+Gyr Technology, Inc.
                    Model: M120




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


               M120 Module User Guide
                   Publication: 98-1718 Rev AA




LANDIS+GYR CONFIDENTIAL INFORMATION


Limitation on Warranties and Liability


Information in this document is subject to change without notice. This manual or any part of it thereof may not be re-
produced in any form unless permitted by contract or by written permission of Landis+Gyr.

In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost prof-
its) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised,
knew, or should have known of the possibility of such damages.

© 2015 Landis+Gyr, Inc. All Rights Reserved

 M120 Module User Guide

 Publication: 98-1718

                                                       Revision History

               Modification Date                   Revision               Description                   Author

 06/09/2015                                       AA             Released                    Charlie Goerges

                                          © 2015 Landis+Gyr • All rights reserved.


M120 Module User Guide


Introduction
             The M120 is a battery operated module designed for automated gas meter reading. The M120 is
             capable of recording gas consumption data from residential gas meters. It has a 2-way radio that is
             compatible with electric meters, routers, and mesh extenders for relaying sensor data to the utility.


Federal Communication Commission (FCC)
Compliance Notice
             This device complies with Part 15 of the FCC rules. Operation is subject to the following two
             conditions:
             1. This device may not cause harmful interference, and
             2. This device must accept any interference received, including interference that may cause
                undesired operation.
             This equipment has been tested and found to comply with the limits for a Class B digital device,
             pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
             against harmful interference in a residential installation. This equipment generates, uses, and can
             radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
             cause harmful interference to radio communications. However, there is no guarantee that
             interference will not occur in a particular installation. If this equipment does cause harmful
             interference to radio or television reception, which can be determined by turning the equipment off
             and on, the user is encouraged to try to correct the interference by one or more of the following
             measures:
             1. Reorient or relocate the receiving antenna.
             2. Increase the separation between the equipment and receiver.
             3. Consult Landis+Gyr or an experienced radio technician for help.

       U     WARNING: Changes or modifications to this device not expressly approved by Landis+Gyr
             will void the equipment warranty.




User Guide                                    98-1718 Rev AA                                                         3


M120 Module User Guide                                                                                   Landis+Gyr


Host FCC Label Requirements
               The host label(s) must be clearly visible after the device is installed, and display the module FCC ID
               in the following format:
               Contains FCC ID: R7PER6R1S2
               The following statement must also be clearly visible:
               This device complies with part 15 of the
               FCC Rules. Operation is subject to the
               following two conditions:
               (1) This device may not cause
               harmful interference, and (2) this
               device must accept any
               interference received, including
               interference that may cause
               undesired operation.


RF Exposure Information
               In accordance with FCC requirements of human exposure to radio frequency fields, the radiating
               element shall be installed such that a minimum separation distance of 20 centimeters (8 inches) will
               be maintained.


Electrical Characteristics
               Battery:
                   •     Battery type: Lithium-Manganese Dioxide
                   •     Nominal voltage: 3.0 V
                   •     Capacity: 4800 mAh
                   •     Landis+Gyr Part number: 40-1235
               DC Characteristics:
                   •     Operating Voltage Range: 2.4 V - 3.3 V
                   •     Typical Sleep Current: 7 uA
               Radio Characteristics:
                   •     Typical Antenna Gain: 0 dBi
                   •     Frequency Range: 902 MHz - 928 MHz
                   •     Modulation Format: FSK
                   •     Transmit Output Power (typical)
                         •   Single Channel Mode: - 27 dBm
                         •   Frequency Hopping Mode: 24 dBm
                   •     Receive sensitivity (typical)

4                                                 98-1718 Rev AA                                         User Guide


Landis+Gyr                                                                             M120 Module User Guide


                     •   9.6 kbps: -112 dBm
                     •   19.2 kbps: -110 dBm
                     •   38.4 kbps: -108 dBm
                     •   115.2 kbps: -101 dBm
                 •   Max Input Power, No Damage: 10 dBm


Functional Description
             The M120 is a wireless battery endpoint for the application of automatic gas meter reading. The
             primary function of the module is to record pulses that represent measurement of gas consumption,
             and then deliver the data to the utility for processing. The block diagram below demonstrates this
             operation.




                                              Figure 1. Operation Block Diagram
             The module is designed to record pulses from a Form-C type pulse initiator. The pulse initiator is a
             sensor board that measures gas volume flow and relays the measurement to the M120 in the form of
             electrical pulses.
             The radio has two operating modes, frequency hopping and single channel. The frequency hopping
             mode is the normal operating mode for network communication. The single channel mode is a low
             power mode, and is primarily used for field diagnostic purposes.




User Guide                                    98-1718 Rev AA                                                      5


M120 Module User Guide                                                                                 Landis+Gyr


Host Installation
               The battery is connected to the battery connector. The sensor board is connected to the M120
               through a flex-cable. See picture below.




                             Battery
                             Connector
                                                                                                         Sensor
                                                                                                         Board


                                                                              Flex Cable




                                                                      M120
                                                                      Module
                                Figure 2. Sensor Board and Battery Connection to M120 Module
               The M120 module and sensor board (pulse initiator) are designed to be heat-staked inside a plastic
               enclosure. See picture below.


                 HEAT STAKE THESE PINS
                TO HOLD SENSOR BOARD                                    HEAT STAKE THESE PINS TO
                        TO HOST                                         HOLD FLEX-CABLE TO HOST




                                                                                 HEAT STAKE THESE TWO
                                                                               PINS TO HOLD M120 TO HOST

                                  Figure 3. M120 Module and Sensor Board Staking Locations



6                                              98-1718 Rev AA                                          User Guide



Document Created: 2015-06-11 09:38:13
Document Modified: 2015-06-11 09:38:13

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC