RF EXPOSURE

FCC ID: R7PER1R2S4

RF Exposure Info

Download: PDF
FCCID_823589

         FCC Part 15.247 Certification
                Test Report

                     FCC ID: R7PER1R2S4

                      FCC Rule Part: 15.247

           ACS Report Number: 07-0292-15C

     Manufacturer: Cellnet Technology, Inc.
 Model: L+G Focus AX w/ Zigbee Utilinet Endpoint




          RF Exposure Information




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Model: L&G Focus AX w/ Zigbee Utilinet Endpoint                                          FCC ID: R7PER1R2S4


General Information:
Applicant:                Cellnet
ACS Project:              07-0292
FCC ID:                   R7PER1R2S4
Device Category:          Mobile
Environment:              General Population/Uncontrolled Exposure

Technical Information 900 MHz Utilinet:
Antenna Type: PCB Slot
Antenna Gain: 3dBi
Transmitter Conducted Power: 17.95dBm
Maximum System EIRP: 20.95dBm
Operating Configuration: Fixed mounted
Exposure Conditions: Greater than 20 centimeters

Technical Information 2400 MHz Zigbee:
Antenna Type: PCB Inverted F
Antenna Gain: 4dBi
Transmitter Conducted Power: 3.55dBm
Maximum System EIRP: 7.55dBm
Operating Configuration: Fixed mounted
Exposure Conditions: Greater than 20 centimeters

MPE Calculation
The Power Density (mW/cm2) is calculated as follows:

      PG
S=
     4πR 2
Where:
S = power density (in appropriate units, e.g. mW/cm2)
P = power input to the antenna (in appropriate units, e.g., mW)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

                                   MPE Calculator for Mobile Equipment
                          Limits for General Population/Uncontrolled Exposure*
  Transmit       Radio          Power         Radio     Antenna Antenna
                                                                           Distance Power Density
 Frequency       Power      Density Limit     Power      Gain     Gain (mW
                                                                             (cm)    (mW/cm^2)
   (MHz)         (dBm)       (mW/Cm2)         (mW)       (dBi)       eq.)
    902.1         17.95          0.60         62.37         3       1.995      20      0.025
    2405           3.55          1.00          2.26         4       2.512      20      0.001

Installation Guidelines
The installation manual should contain text similar to the following advising how to install the equipment to
maintain compliance with the FCC RF exposure requirements:

RF Exposure
In accordance with FCC requirements of human exposure to radio frequency fields, the radiating element
shall be installed such that a minimum separation distance of 20 centimeters will be maintained.

Conclusion
This device complies with the MPE requirements by providing adequate separation between the device,
any radiating structure and the general population.


                 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598



Document Created: 2007-07-27 13:42:55
Document Modified: 2007-07-27 13:42:55

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC