Manual

FCC ID: R7PEG1R1S5

Users Manual

Download: PDF
FCCID_2418042

                   Certification Exhibit



                     FCC ID: R7PEG1R1S5
                      IC: 5294A-EG1R1S5

              FCC Rule Part: 15.247
    IC Radio Standards Specification: RSS-210

               ACS Project Number: 14-0179

      Manufacturer: Landis+Gyr Technology, Inc.
                 Model: G5 26-1905




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Draft 10.8.14




         Gridstream RF
        Generation 5 (G5)
      FOCUS AXe Endpoint
       Quick Start Guide
       Publication: 98-1482 Rev AA


                                              Draft 10.8.14


Limitation on Warranties and Liability


Information in this document is subject to change without notice. This manual or any part of it thereof may not be re-
produced in any form unless permitted by contract or by written permission of Landis+Gyr.

In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost prof-
its) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised,
knew, or should have known of the possibility of such damages.

© 2014 Landis+Gyr, Inc. All Rights Reserved

 Gridstream RF Generation 5 (G5) FOCUS AXe Endpoint Quick Start Guide

 Publication: 98-1482 Rev AA

                                                       Revision History

               Modification Date                   Revision               Description                   Author

 10/08/2014                                       AA             Pending                     Kim Utesch

                                          © 2014 Landis+Gyr • All rights reserved.


                                         Draft 10.8.14
Gridstream RF Generation 5
(G5) FOCUS AXe Endpoint
Quick Start Guide
Gridstream RF Generation 5 (G5) FOCUS AXe Endpoint




                                       Figure 1. FOCUS AXe Meter with a G5 FOCUS AXe Endpoint


G5 FOCUS AXe Endpoint Overview
                    Landis+Gyr FOCUS AXe meters are designed for use in residential and light commercial services.
                    The FOCUS AXe Advanced Function meter is an Active Energy kWh/kW/TOU Meter. The meter
                    features Digital Multiplication Measurement Technique, meets ANSI standards for performance and
                    utilizes ANSI C12.19 protocol.


Quick Start Guide                                  98-1482 Rev AA                                                 3


Quick Start Guide
                                              Draft 10.8.14                                                 Landis+Gyr


                    Contact your Landis+Gyr distributors for documentation and details on programming the FOCUS
                    AXe meter.

About the LAN ID
                    The LAN ID is a unique identifier for each Landis+Gyr endpoint and it is always displayed in hex
                    values. Landis+Gyr provides the LAN address. You cannot change the LAN ID of an endpoint.

Labels
                    The endpoint includes the following labels:




                                                         Figure 2. Label Identification

Demand (TOU Capable)
                        •   Peak demand
                        •   kWh, and kW demand (TOU capable)
                        •   Bi-directional measurement
                        •   Remote disconnect and reconnect capabilities on the FOCUS AXe Service Disconnect meter
                        •   Display and registers powered with disconnect switch in the open position
                        •   Detects, logs and reports program or memory failure
                        •   Module, ZigBee and Metrology firmware can be upgraded via the network
                        •   Metrology firmware can also be upgraded over the optical port
                        •   Normal operation during upgrades (displays blanks momentarily during F/W Flash)
                        •   Meter software remotely and locally readable
                        •   Remote or local load side voltage test
                        •   Self-reads occur at midnight for each register
                        •   Support for 12 self reads

TOU/Recorder
                        •   8-channels of load profile
                        •   Interval data of 1, 5, 15, 30 and 60 minutes
                        •   Interval data collection for energy consumption
                        •   Meter distinguishes between missing interval and zero consumption
                        •   Meter distinguishes between power outage and zero consumption
                        •   5-minute interval data is available for a maximum of 45 days for two channels

4                                                   98-1482 Rev AA                                  Quick Start Guide


Landis+Gyr
                                          Draft 10.8.14                                               Quick Start Guide


                        •   Over-the-air-flashable firmware
                        •   Module, ZigBee and Metrology firmware can be upgraded via the network

Meter Configuration Support
                    Consult Landis+Gyr 1132COM/1132Prog documentation or contact your Landis+Gyr distributor for
                    details on programming the Landis+Gyr meter.

Net Metering
                    Gridstream RF G5 FOCUS AXe endpoints also support the use of the Landis+Gyr meter for net
                    metering usage in metrology values with 5-dial reads or greater. Net metering allows the endpoint to
                    report the net power flow of energy in both directions when power is generated locally at a
                    customer’s site (wind, solar, etc.).




                                                      Figure 3. Enabling Net Metering

Time of Use (Battery-free)
                    Landis+Gyr offers the capability of the endpoint to remotely control up to four TOU schedules. The
                    Meter requires Network Time to keep TOU. The endpoint keeps time once acquired from the
                    Network. The meter must be enabled for TOU.

ZigBee/Home Area Network (HAN) Functionality
                    With the Gridstream RF G5 FOCUS AXe module, Landis+Gyr has the ZigBee radio platform for
                    Gridstream RF which gives a utility the ability to increase consumer awareness of energy
                    consumption and encourage personal responsibility for curbing the energy load. ZigBee released a
                    Smart Energy Profile (SEP) application in early 2008 and it is quickly becoming a standard for
                    communicating between energy management devices as part of a home area network (HAN). The
                    ZigBee radio is located on the Gridstream RF AXe module creating an Energy Service Interface
                    (ESI) that manages the bi-directional communication with ZigBee radio-based devices such as in-
                    home displays, smart thermostats and direct load control devices. See the figure below for a
                    demonstration of the communication flow between Command Center and the devices in the home.




Quick Start Guide                                   98-1482 Rev AA                                                     5


Quick Start Guide
                                               Draft 10.8.14                                                   Landis+Gyr




                                                      Figure 4. ZigBee Communication
                    Using Command Center, the utility sets up the HAN remotely via RF network via a provisioning
                    process. The utility registers each device and a security handshake occurs to ensure protected and
                    closed communication between the meter, endpoint and energy devices in the home.

                    The utility sends downstream pricing information and text messages via Command Center (or 3rd
                    party integrated application) to the module, which uses the ZigBee radio to push down the
                    information to the devices. Because the solution is bi-directional, the devices are also pulling meter
                    data and accurate time that is maintained at the endpoint.
                    The Gridstream RF G5 FOCUS AXe module refreshes data from the meter every 30 seconds and
                    makes it available to all the devices. The endpoint makes available kWh values (delivered only) up
                    to five dial resolution and instantaneous kW up to 99.999 for display. It supports up to five
                    provisioned devices and makes available five tiers for pricing events to align with the meter's
                    number of rates.Text messaging is limited to 80 characters.

                   NOTE: ZigBee radio devices are consumer products and should not be considered part of a
                    mandatory load control program, nor a replacement for viewing energy consumption with the same
                    accuracy found on the meter display. The utility will need to conduct some training of both internal
                    personnel and consumers of the capabilities and limitations of HAN technology.

                    ZigBee radio devices will need to be programmed to respond correctly to each pricing event or Time
                    of Use rate from the meter. An in-home display like the ecoMeter, for instance, will request energy
                    and instantaneous demand data every 7 seconds. It will also request price, which will be provided as
                    flat or Time of Use (TOU) depending on how the meter is programmed. When it sees the meter has
                    changed to Rate B, for instance, it may respond by changing the back lighting to indicate to the
                    consumer that the price of energy has increased.

Gridstream RF Network Indicator
                    This feature provides a ‘communications health’ view of a Gridstream RF enabled electric metering
                    endpoint on the LCD display of the meter. This health check information can be utilized during field
                    installation or troubleshooting activities to validate status of the Gridstream RF electric endpoint,
                    and provide key inputs to any communications issues that may be encountered from time to time.



6                                                    98-1482 Rev AA                                     Quick Start Guide


Landis+Gyr
                                           Draft 10.8.14                                              Quick Start Guide


                    The network indicator feature will display two key elements of communications health
                    characteristics.
                        •   Communication Hardware Status: Information about AMI radio communications, HAN
                            (ZigBee) radio communications, and the interactions between the two
                        •   RF Mesh Neighbor Status: Information about the number of RF mesh neighbors available
                            for network communications
                    For more information on this feature see Appendix E: <Italics>"Gridstream RF Network Indicator"
                    on page -109.

Power Outage/Restoration
                    When an outage occurs, the meter uses an early power failure signal to alert the communication
                    module to disconnect from the meter's power immediately. The communication module saves
                    critical module data to non-volatile memory and creates and sends a power outage message. This
                    message includes the following information:
                        •   LAN ID
                        •   Outage time
                        •   Reboot count
                    The communication module sends the message, then assists with routing other packets until the
                    back-up energy source can no longer keep the radio alive.
                    When power is restored, the communication module connects with the network. With network
                    communications restored, the communication module sends a power restoration message that
                    includes details such as:
                        •   LAN ID
                        •   Outage time
                        •   Restoration time
                        •   Reboot count
                    The communication module stores a history of up to the last five power outage and restoration event
                    pairs in the event log. The Host can request this data.

                   NOTE: The module is designed with a high temperature protection feature in which the firmware
                    automatically starts draining the super capacitor responsible for outage notification at 65 degrees
                    Celsius.


Standards Compliance
                    The Gridstream RF G5 FOCUS AXe module has Smart Utility Network (SUN) 802.15 4G ready
                    hardware.

Flash Memory Options
                    The standard hardware configuration for the Gridstream RF G5 FOCUS AXe modules has 4MB
                    flash memory. An 8MB flash memory option is also available.



Quick Start Guide                                   98-1482 Rev AA                                                        7


Quick Start Guide
                                         Draft 10.8.14                                                        Landis+Gyr


Gridstream RF G5 FOCUS AXe Specifications
                                                     Table 1. Specifications
               Category        Specification                       Value or Range
                                                                   FOCUS AXe                       FOCUS AXe-SD

                                                                   Form            Class           Form         Class

                                                                   1S              100             1S           200

                                                                   1S              200             2S           200

               Compatible      Landis+Gyr FOCUS AXe                2S              200             12S          200
               Meters          Supported Meter Forms               2SE             320             25S          200

                                                                   2K              480

                                                                   3S 120V         10/20

                                                                   3S 240V         10/20

                                                                   4S              10/20

                               Voltage                             3.8 V-4.2 V DC (from the meter's power supply)
               Electrical
                               Power                               Max: 5.6 W; Typical: 0.5W

                               Output Power                        +27 dBm Typical
                               Adjacent Channel Power              40 dBc Typical (9.6 kbps)

                               Transmit Frequency                  902.2 to 927.9 MHz ISM unlicensed (FCC Part 15)
               RF 900 MHz RF
                                                                    -114 dBm Typical (9.6 kbps)
                               Receive Sensitivity                 -105 dBm Typical (115.2 kbps)
                                                                   -99 dBm Typical (300 kbps)

                               RF Baud Rates Supported             9.6, 19.2, 38.4, 50, 115.2, 150, 200, 300 kbps
                               Output Power                        +20 dBm Typical

                               Error Vector Magnitude %            5% Typical

               RF ZigBee       Transmit Frequency                  2.405 to 2.475 GHz

                               Communication Protocol              ZigBee Protocol

                               Receive Sensitivity                 -104 dBm Typical

                                                                   Radiated and Conducted Emissions (incl. intentional
                               FCC Title 47 CFR Part 15
                                                                   radiators)

                               IEC 61000 4-2,3,4,5,11,12           Electromagnetic Compatibility

               Standards       ANSI C12.19                         Compatible with Utility Industry End Device Tables
               Compliance                                          National Standard for Electricity Meters - 0.2 and
                               ANSI C12.20
                                                                   0.5 Accuracy Classes

                               ANSI C12.21                         Code for Electricity Metering

                               ANSI C37.90.1 (1989)                Standard Surge Withstand Capability (SWC) Tests




8                                              98-1482 Rev AA                                            Quick Start Guide


Landis+Gyr
                                          Draft 10.8.14                                                     Quick Start Guide


                                                  Table 1. Specifications (Continued)
               Category               Specification                       Value or Range

                                      General Environmental               Outdoor, rain-protected, sunlight-exposed

               Environmental          Operating Temperature Range         -40 to +85 C (under meter cover

                                      Humidity                            0 to 95% relative humidity, non-condensing



FCC and Industry Canada Compliance
FCC Class B
                    This device complies with Part 15 of the FCC rules. Operation is subject to the following two
                    conditions:
                    1. This device may not cause harmful interference, and
                    2. This device must accept any interference received, including interference that may cause
                       undesired operation.
                    This equipment has been tested and found to comply with the limits for a Class B digital device,
                    pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
                    against harmful interference in a residential installation. This equipment generates, uses, and can
                    radiate radio frequency energy and, if not installed and used in accordance with the Instructions, may
                    cause harmful interference to radio communications. However, there is no guarantee that
                    interference will not occur in a particular installation. If this equipment does cause harmful
                    interference to radio or television reception, which can be determined by turning the equipment off
                    and on, the user is encouraged to try to correct the interference by one or more of the following
                    measures:
                        •   Reorient or relocate the receiving antenna.
                        •   Increase the separation between the equipment and receiver.
                        •   Consult Landis+Gyr or an experienced radio technician for help

       U            WARNING: Changes or modifications to this device not expressly approved by Landis+Gyr
                    could void the user’s authority to operate the equipment.



RF Exposure
                    This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
                    environment. This equipment should be installed and operated with minimum distance 20 cm
                    between the radiator and your body. This transmitter must not be co-located or operating in
                    conjunction with any other antenna or transmitter.


Industry Canada
                    This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
                    the following two conditions: (1) this device may not cause interference, and (2) this device must
                    accept any interference, including interference that may cause undesired operation of the device.


Quick Start Guide                                     98-1482 Rev AA                                                       9


Quick Start Guide
                                               Draft 10.8.14                                                   Landis+Gyr


                    Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a
                    type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce
                    potential radio interference to other users, the antenna type and its gain should be so chosen that the
                    equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
                    communication.
                    Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
                    exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit
                    pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage
                    radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
                    Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner
                    avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par
                    Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des
                    autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
                    rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une
                    communication satisfaisante.




10                                                   98-1482 Rev AA                                      Quick Start Guide



Document Created: 2014-10-10 16:34:49
Document Modified: 2014-10-10 16:34:49

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC