Test Report

FCC ID: R7PEC6R2S3

Test Report

Download: PDF
FCCID_2660760

                                               Certification Test Report

                                                          FCC ID: R7PEC6R2S3
                                                           IC: 5294A-EC6R1S3

                                           FCC Rule Part: 15.249
                                 IC Radio Standards Specification: RSS-210

                                       ACS Report Number: 15-0160.W06.2A


                                    Manufacturer: Landis+Gyr Technology, Inc.
                                                  Model: GPR2

                                                 Test Begin Date: April 27, 2015
                                                  Test End Date: April 29, 2015

                                              Report Issue Date: June 19, 2015




                                       FOR THE SCOPE OF ACCREDITATION UNDER LAB Code 200612-0

This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of
                                                       the Federal Government.




                                                Reviewed by:
                                                                   Kirby Munroe
                                                         Director, Wireless Certifications
                                                                     ACS, Inc.

This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of ACS, Inc. The results contained in this report
                                                        are representative of the sample(s) submitted for evaluation.
                                                            This report contains 16 pages

                          5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


                                                         TABLE OF CONTENTS
1      GENERAL ............................................................................................................................................ 3
    1.1       PURPOSE.......................................................................................................................................... 3
    1.2       PRODUCT DESCRIPTION ................................................................................................................... 3
    1.3       TEST METHODOLOGY AND CONSIDERATIONS ................................................................................. 4
2      TEST FACILITIES .............................................................................................................................. 5
    2.1     LOCATION ....................................................................................................................................... 5
    2.2     LABORATORY ACCREDITATIONS/RECOGNITIONS/CERTIFICATIONS ................................................ 5
    2.3     RADIATED EMISSIONS TEST SITE DESCRIPTION .............................................................................. 6
       2.3.1    Semi-Anechoic Chamber Test Site .......................................................................................... 6
       2.3.2    Open Area Tests Site (OATS) ................................................................................................. 7
    2.4     CONDUCTED EMISSIONS TEST SITE DESCRIPTION ........................................................................... 8
3      APPLICABLE STANDARD REFERENCES.................................................................................... 8

4      LIST OF TEST EQUIPMENT ............................................................................................................ 9

5      SUPPORT EQUIPMENT ...................................................................................................................10

6      EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM ..........................................................10

7      SUMMARY OF TESTS ......................................................................................................................11
    7.1     ANTENNA REQUIREMENT – FCC 15.203 ........................................................................................11
    7.2     POWER LINE CONDUCTED EMISSIONS – FCC 15.207; IC RSS-GEN 8.8 .........................................11
    7.3     20DB / 99% BANDWIDTH – FCC 15.215; IC RSS-GEN 6.6.............................................................11
       7.3.1    Measurement Procedure ........................................................................................................11
       7.3.2    Measurement Results .............................................................................................................11
    7.4     FUNDAMENTAL FIELD STRENGTH – FCC 15.249(A); IC RSS-210 A2.9(A) ....................................13
       7.4.1    Measurement Procedure ........................................................................................................13
       7.4.2    Measurement Results .............................................................................................................13
    7.5     RADIATED SPURIOUS EMISSIONS – FCC 15.249(A)(D)(E); IC RSS-210 A2.9(A)(B) .......................14
       7.5.1    Measurement Procedure ........................................................................................................14
       7.5.2    Measurement Results .............................................................................................................14
       7.5.3    Sample Calculation: ..............................................................................................................15
8      CONCLUSION ....................................................................................................................................16




                    5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


    Model: GPR2                         FCC ID: R7PEC6R2S3             IC: 5294A-EC6R1S3

1     GENERAL

1.1      Purpose

The purpose of this report is to demonstrate compliance with Part 15 Subpart C of the FCC’s
Code of Federal Regulations and Industry Canada’s Radio Standards Specification RSS-210 for
modular approval certification.

1.2      Product description

The GPR2 is a battery-powered 2-way gas module that operates in the frequency range of 902.3
– 927.5 MHz. The GPR2 is designed to provide two-way communications within the Landis+Gyr
Gridstream RF network, and can communicate with electric meters, routers, mesh extenders or
radios on distribution automation devices.

Technical Information:
The model 2 provides two distinct modes of operation; frequency hopping mode at high power,
and single channel mode at low power. This report addresses the single channel mode as
outlined below.

                         Frequency                         Channel          Data Rates
                                          Number of
Mode of Operation          Range                          Separation        Supported
                                          Channels
                           (MHz)                            (kHz)             (kbps)
          1             902.3 - 927.5            64          400               115.2

Modulation Format:     FSK/GFSK
Antenna Type / Gain:   Inverted F / 2dBi gain
Operating Voltage:     3VDC (Internal Battery)

Manufacturer Information:
Landis+Gyr Technology, Inc.
30000 Mill Creek Ave., Suite 100
Alpharetta, GA 30022

EUT Serial Numbers: E145S311400000070 (Radiated), E145S311400000058 (RF Conducted)

Test Sample Condition: The test samples were provided in good working order with no visible
defects.




    ACS Report: 15-0160.W06.2A           Advanced Compliance Solutions             Page 3


 Model: GPR2                               FCC ID: R7PEC6R2S3               IC: 5294A-EC6R1S3

1.3     Test Methodology and Considerations

For radiated emissions, the EUT was configured in an orientation typical of normal installation.

The EUT is battery operated; therefore, AC power-line conducted emissions are not applicable.

Software power setting during test (900 MHz Radio): 00




 ACS Report: 15-0160.W06.2A                Advanced Compliance Solutions                  Page 4


    Model: GPR2                           FCC ID: R7PEC6R2S3              IC: 5294A-EC6R1S3

2     TEST FACILITIES

2.1      Location

The radiated and conducted emissions test sites are located at the following address:

      Advanced Compliance Solutions
      5015 B.U. Bowman Drive
      Buford, GA 30518
      Phone: (770) 831-8048
      Fax: (770) 831-8598

2.2      Laboratory Accreditations/Recognitions/Certifications

ACS is accredited to ISO/IEC 17025 by the National Institute of Standards and Technology under
their National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 200612-0. Unless
otherwise specified, all tests methods described within this report are covered under the ISO/IEC
17025 scope of accreditation.

The Semi-Anechoic Chamber Test Site, Open Area Test Site (OATS) and Conducted Emissions
Site have been fully described, submitted to, and accepted by the FCC, Industry Canada and the
Japanese Voluntary Control Council for Interference by information technology equipment.

FCC Registration Number: 511277
Industry Canada Lab Code: IC 4175A
VCCI Member Number: 1831
•       VCCI OATS Registration Number R-1526
•       VCCI Conducted Emissions Site Registration Number: C-1608




    ACS Report: 15-0160.W06.2A            Advanced Compliance Solutions                 Page 5


 Model: GPR2                                FCC ID: R7PEC6R2S3                IC: 5294A-EC6R1S3

2.3     Radiated Emissions Test Site Description

2.3.1   Semi-Anechoic Chamber Test Site

The Semi-Anechoic Chamber Test Site consists of a 20’ x 30’ x 18’ shielded enclosure. The
chamber is lined with Toyo Ferrite Grid Absorber, model number FFG-1000. The ferrite tile grid is
101 x 101 x 19mm thick and weighs approximately 550 grams. These tiles are mounted on steel
panels and installed directly on the inner walls of the chamber.

The turntable is 150cm in diameter and is located 160cm from the back wall of the chamber. The
chamber is grounded via 1 - 8’ copper ground rod, installed at the center of the back wall, it is
bound to the ground plane using 3/4" stainless steel braided cable.

The turntable is all steel, flush mounted table installed in an all steel frame. The table is remotely
operated from inside the control room located 25’ from the range. The turntable is electrically
bonded to the surrounding ground plane via steel fingers installed on the edge of the turn table.
The steel fingers make constant contact with the ground plane during operation.

Behind the turntable is a 3’ x 6’ x 4’ deep shielded pit used for support equipment if necessary.
The pit is equipped with 1 - 4” PVC chases from the turntable to the pit that allow for cabling to
the EUT if necessary. The underside of the turntable can be accessed from the pit so cables can
be supplied to the EUT from the pit.

A diagram of the Semi-Anechoic Chamber Test Site is shown in Figure 2.3-1 below:




                                             3 Meters


                                                                         5 Feet
                                                                        Diameter




                                                                                    20 Feet


                                               30 Feet
                        Figure 2.3-1: Semi-Anechoic Chamber Test Site




 ACS Report: 15-0160.W06.2A                 Advanced Compliance Solutions                   Page 6


 Model: GPR2                               FCC ID: R7PEC6R2S3                 IC: 5294A-EC6R1S3

2.3.2   Open Area Tests Site (OATS)

The open area test site consists of a 40’ x 66’ concrete pad covered with a perforated electro-
plated galvanized sheet metal. The perforations in the sheet metal are 1/8” holes that are
staggered every 3/16”. The individual sheets are placed to overlap each other by 1/4” and are
riveted together to provide a continuous seam. Rivets are spaced every 3” in a 3 x 20 meter
perimeter around the antenna mast and EUT area. Rivets in the remaining area are spaced as
necessary to properly secure the ground plane and maintain the electrical continuity.

The entire ground plane extends 12’ beyond the turntable edge and 16’ beyond the antenna mast
when set to a 10 meter measurement distance. The ground plane is grounded via 4 - 8’ copper
ground rods, each installed at a corner of the ground plane and bound to the ground plane using
3/4" stainless steel braided cable.

The turntable is an all aluminum 10’ flush mounted table installed in an all aluminum frame. The
table is remotely operated from inside the control room located 40’ from the range. The turntable
is electrically bonded to the surrounding ground plane via steel fingers installed on the edge of
the turn table. The steel fingers make constant contact with the ground plane during operation.

Adjacent to the turntable is a 7’ x 7’ square and 4’ deep concrete pit used for support equipment if
necessary. The pit is equipped with 5 - 4” PVC chases from the pit to the control room that allow
for cabling to the EUT if necessary. The underside of the turntable can be accessed from the pit
so cables can be supplied to the EUT from the pit. The pit is covered with 2 sheets of 1/4"
diamond style re-enforced steel sheets. The sheets are painted to match the perforated steel
ground plane; however the underside edges have been masked off to maintain the electrical
continuity of the ground plane. All reflecting objects are located outside of the ellipse defined in
ANSI C63.4.

A diagram of the Open Area Test Site is shown in Figure 2.3-2 below:



                                             10Meters


                                                        3 Meters



                                                                                  40Feet




                                                                      7x7x4
                                                                       Pit

                                           66 Feet

                               Figure 2.3-2: Open Area Test Site




 ACS Report: 15-0160.W06.2A                Advanced Compliance Solutions                   Page 7


    Model: GPR2                              FCC ID: R7PEC6R2S3               IC: 5294A-EC6R1S3

2.4       Conducted Emissions Test Site Description

The AC mains conducted EMI site is located in the main EMC lab. It consists of an 8’ x 8’ solid
aluminum horizontal ground reference plane (GRP) bonded every 3” to an 8’ X 8’ vertical ground
plane.

The site is of sufficient size to test table top and floor standing equipment in accordance with
section 6.1.4 of ANSI C63.4.

A diagram of the room is shown below in figure 4.1.3-1:



                  Vertical Ground Plane (8’ x 8’)




                                                     Non-Conductive EUT Table
                                                         (1m x 1.5m x .8m)


             .4 Meters




                .8 Meters


                                                           Horizontal Ground Plane (8’ x 8’)

              LISN
                            Figure 2.4-1: AC Mains Conducted EMI Site

3     APPLICABLE STANDARD REFERENCES

The following standards were used:
         ANSI C63.10-2009: American National Standard for Testing Unlicensed Wireless Devices
         ANSI C63.10-2013: American National Standard of Procedures for Compliance Testing of
          Unlicensed Wireless Devices – Reference for Industry Canada only
         US Code of Federal Regulations (CFR): Title 47, Part 2, Subpart J: Equipment Authorization
          Procedures, 2015
         US Code of Federal Regulations (CFR): Title 47, Part 15, Subpart C: Radio Frequency Devices,
          Intentional Radiators, 2015
         Industry Canada Radio Standards Specification: RSS-210 - Low-power License-exempt
          Radiocommunication Devices (All Frequency Bands): Category I Equipment, Issue 8, December
          2010
         Industry Canada Radio Standards Specification:      RSS-GEN – General Requirements for
          Compliance of Radio Apparatus, Issue 4, November 2014.




    ACS Report: 15-0160.W06.2A               Advanced Compliance Solutions                     Page 8


    Model: GPR2                                          FCC ID: R7PEC6R2S3                     IC: 5294A-EC6R1S3

4      LIST OF TEST EQUIPMENT

The calibration interval of test equipment is annually or the manufacturer’s recommendations.
Where the calibration interval deviates from the annual cycle based on the instrument
manufacturer’s recommendations, it shall be stated below.

                                             Table 4-1: Test Equipment
                                                                                                                  Calibration
    AssetID       Manufacturer            Model #        Equipment Type        Serial #   Last Calibration Date    Due Date
      1         Rohde & Schwarz        ESMI - Display   Spectrum Analyzers   833771/007         7/11/2014          7/11/2015
      2         Rohde & Schwarz        ESMI-Receiver    Spectrum Analyzers   839587/003         7/11/2014          7/11/2015
      30      Spectrum Technologies     DRH-0118            Antennas           970102           4/23/2013          5/23/2015
      40             EMCO                  3104             Antennas            3211            2/10/2015          2/10/2017
      73             Agilent              8447D             Amplifiers       2727A05624         7/15/2014          7/15/2015
                                       Chamber EMI
     167              ACS                Cable Set          Cable Set           167            10/28/2014         10/28/2015
     267             Agilent              N1911A             Meters          MY45100129         7/30/2013          7/30/2015
     268             Agilent              N1921A             Sensors         MY45240184         7/30/2013          7/30/2015
                                       SMR-290AW-
     292       Florida RF Cables        480.0-SMR            Cables             None           3/3/2015           3/3/2016
     331       Microwave Circuits       H1G513G1              Filters           31417          6/2/2014           6/2/2015
     338        Hewlett Packard           8449B             Amplifiers       3008A01111        7/30/2013          7/30/2015
     340       Aeroflex/Weinschel          AS-20           Attenuators          7136           7/14/2014          7/14/2015
     412         Electro Metrics          LPA-25            Antennas            1241           7/24/2014          7/24/2016
                                      SMS-200AW-72.0-
     422           Florida RF              SMR               Cables             805            11/5/2014          11/5/2015
                                      SMRE-200W-12.0-
     616        Florida RF Cables          SMRE              Cables              N/A           9/10/2014          9/10/2015
     622        Rohde & Schwarz           FSV40             Analyzers          101338          7/12/2014          7/12/2015




    ACS Report: 15-0160.W06.2A                           Advanced Compliance Solutions                            Page 9


    Model: GPR2                            FCC ID: R7PEC6R2S3        IC: 5294A-EC6R1S3

5       SUPPORT EQUIPMENT

                              Table 5-1: Support Equipment
Item      Equipment Type    Manufacturer    Model Number            Serial Number
    1         Battery         Landis + Gyr           40-1235               N/A


6       EQUIPMENT UNDER TEST SETUP BLOCK DIAGRAM




                                               EUT




                                                    A



                                                1




    A: DC Power Cable, 7cm, Non-shielded


                           Figure 6-1: Test Setup Block Diagram




ACS Report: 15-0160.W06.2A                 Advanced Compliance Solutions         Page 10


    Model: GPR2                           FCC ID: R7PEC6R2S3              IC: 5294A-EC6R1S3

7     SUMMARY OF TESTS

Along with the tabular data shown below, plots were taken of all signals deemed important
enough to document.

7.1      Antenna Requirement – FCC 15.203

The integral antenna is an Inverted F with 2dBi gain and cannot be removed without permanently
damaging the device, therefore satisfying the requirements of Section 15.203.


7.2      Power Line Conducted Emissions – FCC 15.207; IC RSS-Gen 8.8

The EUT is a battery operated module; therefore, AC power line conducted emissions testing was
not performed.


7.3      20dB / 99% Bandwidth – FCC 15.215; IC RSS-Gen 6.6

7.3.1    Measurement Procedure

The span of the spectrum analyzer display was set between two times and five times the
occupied bandwidth (OBW) of the emission. The RBW of the spectrum analyzer was set to
approximately 1 % to 5 % of the OBW. The trace was set to max hold with a peak detector active.
The Delta function of the analyzer was utilized to determine the 20 dB bandwidth of the emission.

The occupied bandwidth measurement function of the spectrum analyzer was used to measure
the 99% bandwidth. The span of the analyzer was set to capture all products of the modulation
process, including the emission sidebands. The resolution bandwidth was set to 1% to 5% of the
occupied bandwidth. The video bandwidth was set to 3 times the resolution bandwidth. A peak
detector was used.

7.3.2    Measurement Results


                             Table 7.3.2-1: 20dB / 99% Bandwidth

                                         20dB Bandwidth              99% Bandwidth
            Frequency (MHz)
                                              (kHz)                      (kHz)

                  902.3                       235.512                    211.033
                  914.8                       234.852                    210.713
                  927.5                       235.172                    212.593




 ACS Report: 15-0160.W06.2A              Advanced Compliance Solutions                 Page 11


Model: GPR2                                FCC ID: R7PEC6R2S3             IC: 5294A-EC6R1S3




       Figure 7.3.2-1: 20dB BW Low Channel           Figure 7.3.2-2: 20dB BW Mid Channel




      Figure 7.3.2-3: 20dB BW High Channel            Figure 7.3.2-4: 99% BW Low Channel




      Figure 7.3.2-5: 99% BW Mid Channel              Figure 7.3.2-6: 99% BW High Channel




ACS Report: 15-0160.W06.2A                 Advanced Compliance Solutions                   Page 12


 Model: GPR2                                    FCC ID: R7PEC6R2S3                       IC: 5294A-EC6R1S3

7.4       Fundamental Field Strength – FCC 15.249(a); IC RSS-210 A2.9(a)

7.4.1     Measurement Procedure

The EUT was rotated through 360° and the receive antenna height was varied from 1m to 4m so
that the maximum radiated emissions level would be detected. Quasi-peak measurements were
made with RBW and VBW of 120 kHz and 300 kHz respectively.

7.4.2     Measurement Results


                                Table 7.4.2-1: Fundamental Field Strength
                        Level        Antenna    Correction    Corrected Level           Limit           Margin
  Frequency            (dBuV)        Polarity    Factors         (dBuV/m)             (dBuV/m)           (dB)
    (MHz)
                  pk       Qpk/Avg    (H/V)        (dB)         pk       Qpk/Avg     pk     Qpk/Avg pk       Qpk/Avg
      902.3    ---------    67.47       H          0.31      ---------    67.78    --------  94.0   --------  26.2
      902.3    ---------    62.51       V          0.31      ---------    62.82    --------  94.0   --------  31.2
      914.8    ---------    68.25       H          1.10      ---------    69.35    --------  94.0   --------  24.6
      914.8    ---------    63.04       V          1.10      ---------    64.14    --------  94.0   --------  29.8
      927.5    ---------    65.30       H          1.13      ---------    66.43    --------  94.0   --------  27.6
      927.5    ---------    61.11       V          1.13      ---------    62.24    --------  94.0   --------  31.7




 ACS Report: 15-0160.W06.2A                     Advanced Compliance Solutions                            Page 13


 Model: GPR2                                            FCC ID: R7PEC6R2S3                             IC: 5294A-EC6R1S3

7.5       Radiated Spurious Emissions – FCC 15.249(a)(d)(e); IC RSS-210 A2.9(a)(b)

7.5.1     Measurement Procedure

Radiated emissions tests were made over the frequency range of 30MHz to 10 GHz, > 10 times
the highest fundamental frequency.

The EUT was rotated through 360° and the receive antenna height was varied from 1m to 4m so
that the maximum radiated emissions level would be detected. For frequencies below 1000MHz,
quasi-peak measurements were made using a resolution bandwidth RBW of 120 kHz and a video
bandwidth VBW of 300 kHz. For frequencies above 1000MHz, peak and average measurements
were made with RBW and VBW of 1 MHz and 3MHz respectively.

All out of band emissions were evaluated, including any emissions at or near the band-edge.

7.5.2     Measurement Results


                                 Table 7.5.2-1: Radiated Spurious Emissions
                           Level           Antenna     Correction      Corrected Level            Limit                 Margin
      Frequency           (dBuV)           Polarity     Factors           (dBuV/m)              (dBuV/m)                 (dB)
        (MHz)
                    pk         Qpk/Avg       (H/V)         (dB)         pk        Qpk/Avg     pk       Qpk/Avg     pk        Qpk/Avg
                                                902.3 MHz (Low Channel)
         902      ---------     30.72          H           0.28       ---------    31.00    --------    46.0     ---------    15.0
         902      ---------     25.89          V           0.28       ---------    26.17    --------    46.0     ---------    19.8
                                               914.8 MHz (Middle Channel)
                              No Emissions detected above the noise floor of the measurement system.
                                                927.5 MHz (High Channel)
         928      ---------     22.82          H           1.12       ---------    23.94    --------    46.0     ---------    22.1
         928      ---------     21.47          V           1.12       ---------    22.59    --------    46.0     ---------    23.4




 ACS Report: 15-0160.W06.2A                             Advanced Compliance Solutions                                        Page 14


 Model: GPR2                           FCC ID: R7PEC6R2S3          IC: 5294A-EC6R1S3

7.5.3 Sample Calculation:
RC = RU + CFT

Where:
CFT      =     Total Correction Factor (AF+CA+AG)-DC (Average Measurements Only)
RU       =     Uncorrected Reading
RC       =     Corrected Level
AF       =     Antenna Factor
CA       =     Cable Attenuation
AG       =     Amplifier Gain
DC       =     Duty Cycle Correction Factor


Example Calculation: Quasi-Peak
Corrected Level: 30.72 + 0.28 = 31.00dBuV
Margin: 46dBuV – 31.00dBuV = 15.00dB




ACS Report: 15-0160.W06.2A             Advanced Compliance Solutions           Page 15


    Model: GPR2                         FCC ID: R7PEC6R2S3             IC: 5294A-EC6R1S3

8     CONCLUSION

In the opinion of ACS, Inc. the GPR2, manufactured by Landis+Gyr Technology, Inc. meets the
requirements of FCC Part 15 subpart C and Industry Canada’s Radio Standards Specification
RSS-210.




                                   END REPORT




ACS Report: 15-0160.W06.2A              Advanced Compliance Solutions               Page 16



Document Created: 2015-06-18 17:18:47
Document Modified: 2015-06-18 17:18:47

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC