Manual

FCC ID: R7PEC1R1S1

Users Manual

Download: PDF
FCCID_2126790

                   Certification Exhibit



                     FCC ID: R7PEC1R1S1

                      FCC Rule Part: 15.247

               ACS Project Number: 12-0278

       Manufacturer: Landis+Gyr Technology Inc.
       Model: Elster Multi-Function Meter Module




                               Manual




5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598


Draft 8/23/2013


                  Elster Multi-Function
                      Meter Module
                   Quick Start Guide
                   Publication: 98-1289 Rev AA




LANDIS+GYR CONFIDENTIAL INFORMATION


                           Draft 8/23/2013
Limitation on Warranties and Liability


Information in this document is subject to change without notice. This manual or any part of it thereof may not be re-
produced in any form unless permitted by contract or by written permission of Landis+Gyr.

In no event will Landis+Gyr be liable for any incidental, indirect, special, or consequential damages (including lost prof-
its) arising out of or relating to this publication or the information contained in it, even if Landis+Gyr has been advised,
knew, or should have known of the possibility of such damages.

Other brands or product names used are the trademarks or registered trademarks of their respective holders.


© 2013 Landis+Gyr, Inc. All Rights Reserved

 Elster Multi-Function Meter Module Quick Start Guide

 Publication: 98-1289

                                                        Revision History

               Modification Date                   Revision                Description                  Author

 12/4/2012                                        AA              In Progress                Vicky Costello

 Landis+Gyr
 30000 Mill Creek Avenue, Suite 100
 Alpharetta, GA 30022                             Copyright© 2013 Landis+Gyr
 Website: www.landisgyr.com                       All rights reserved.
 E-mail: solutionsupport.na@landisgyr.com
 Technical Support: 1-888-390-5733


                     Draft 8/23/2013
Elster Multi-Function Meter
Module Quick Start Guide

Overview
                 The Elster Multi-Function Meter Module (MFMM) is designed to provide active energy (Kilo-Watt
                 hour) and reactive energy (Kilo-Var hour) data from Elster Alpha+ (A2) meters for use in residential
                 and industrial commercial services.




                                           Figure 1 - 1. Elster Multi-Function Meter Module

                 The meter kit includes:
                     •   Elster Multi-Function Meter Module
                     •   Elster Alpha+ (A2) Meter


Landis+Gyr Confidential Information               98-1289 Rev AA                                                    3


                           Draft 8/23/2013
Elster Multi-Function Meter Module Quick Start Guide                                                             Landis+Gyr


                      •    Antenna


Required Software
                 To work with the endpoint, you need at least one of the following software tools and documentation:
                      •    UtiliNet Solution Center (USC)
                      •    Meter Master Lite software
                           •      Meter Master Lite Quick Start Guide, publication number 98-0071
                      •    Elster ALPHA Plus software
                 Landis+Gyr recommends you have RF Verify software and the RF Verify User Guide, publication
                 number 98-0069.

Labels
                 The endpoint contains the following labels:




                                           1                                                                      3

                      2



                                                       Figure 2. Label Identification



                                                    Table 1. Elster Label Identification
                          Label                           Description

                  1       Elster Meter Name Plate         AEP compliant bar code that defines meter manufacturer, form,
                                                          base, test voltage and current, watt-hour constant, serial number,
                                                          and customer specific information.

                                                          Manufacturer or customer specified serial number

                                                          Manufacturer model and style number


4                                                    98-1289 Rev AA                   Landis+Gyr Confidential Information


Landis+Gyr
                      Draft 8/23/2013                           Elster Multi-Function Meter Module Quick Start Guide


                                                 Table 1. Elster Label Identification
                       Label                            Description

                  2    Landis+Gyr FCC ID                Federal Communications Commission (FCC) Identification (ID)
                                                        number assigned to the Elster Multi-Function Meter Module for
                                                        use in the Elster Alpha+ meter.

                  3    Landis+Gyr LAN ID                Identifies the Elster Multi-Function Meter Module to the
                                                        Landis+Gyr billing network (printed and barcoded).


LAN ID
                 The LAN ID is a unique identifier for each Landis+Gyr endpoint. Landis+Gyr provides the LAN
                 address. You cannot change the radio’s LAN IDs.


Features and Functions
Endpoint Registration
                 The endpoint is automatically registered with the host system. No special tools are needed during
                 installation.
                 Admin packets are sent once each hour at a random time during the hour and play a crucial role in
                 the automatic discovery of a meter by the Landis+Gyr system. They tell what kind of meter the
                 module interfaces with, and other characteristics, such as the scaling constant, number of dials, and
                 the firmware version.
                 Admin packets include:

                                                 Table 2. Admin Packet Information
                  Meter ID                            Identifies the customer

                  Protocol ID                         Identifies the type of meter.

                  Scaling Constant                    Tells how to convert meter readings into real units such as kWh

                  Number of dials                     Also referred to as displayed digits.

                                                      Tells how much the meter reading can change in a certain period of
                  Maximum Sensor Change Rate
                                                      time.

                  Firmware Version                    Specifies the firmware revision number.

                  Current Cumulative Reading from the meter


Communication and Retrieving Data
                 A microprocessor on the communications module (MFMM) reads energy data through the meter’s
                 serial interface and transmits the information to the head end system. Several different packet types
                 are sent.The most frequently sent packet contains the current rotational count and historical interval
                 data that is useful for load profiling and time-of-use metering. Another less frequently sent (Admin)
                 packet contains the current cumulative rotation count, useful for basic automatic meter reading
                 applications. An Admin packet is sent once hourly and contains the information listed in Table 2.


Landis+Gyr Confidential Information               98-1289 Rev AA                                                           5


                         Draft 8/23/2013
Elster Multi-Function Meter Module Quick Start Guide                                                       Landis+Gyr


Power Outage/Restoration
                 The Multi-Function Meter Module gets Power Fail signal from meter. The communication module
                 saves critical endpoint data to non-volatile memory, creates and sends a configurable number of
                 power fail messages (typically 20) to the host system that include the LAN ID.
                 When power is restored, the communication module (MFMM) sends a Power Up message from
                 Channel 1 and Channel 2, if available, to the host system. This message includes the following
                 information:
                     •   LAN ID
                     •   Total count
                     •   Last ten interval counts


Customer Service
                 Contact Landis+Gyr Customer Support at solutionsupport.na@landisgyr.com or call 888-390-5733
                 with any questions or problems for guidance through the troubleshooting process.


Compliance
FCC Class B
                 This device complies with Part 15 of the FCC rules. Operation is subject to the following two
                 conditions:
                 (1) This device may not cause harmful interference, and
                 (2) This device must accept any interference received, including interference that may cause
                 undesired operation.
                 This equipment has been tested and found to comply with the limits for a Class B digital device,
                 pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
                 against harmful interference in a residential installation. This equipment generates, uses, and can
                 radiate radio frequency energy and, if not installed and used in accordance with the Instructions, may
                 cause harmful interference to radio communications. However, there is no guarantee that
                 interference will not occur in a particular installation. If this equipment does cause harmful
                 interference to radio or television reception, which can be determined by turning the equipment off
                 and on, the user is encouraged to try to correct the interference by one or more of the following
                 measures:
                     •   Reorient or relocate the antenna.
                     •   Increase the separation between the equipment and receiver.
                     •   Consult Landis+Gyr or an experienced radio technician for help.

       U         WARNING: Changes or modifications to this device not expressly approved by Landis+Gyr
                 could void the user’s authority to operate the equipment.




6                                                   98-1289 Rev AA                Landis+Gyr Confidential Information


Landis+Gyr
                     Draft 8/23/2013                            Elster Multi-Function Meter Module Quick Start Guide


RF Exposure
                 In accordance with FCC requirements of human exposure to radio frequency fields, the radiating
                 element shall be installed such that a minimum separation distance of 20 centimeters will be
                 maintained.




Host FCC Label Requirement
                 In the final installation, the following information must be visible:
                 “Contains FCC ID: R7PEC1R1S1
                 This device complies with Part 15 of the FCC rules. Operation is subject to the following two
                 conditions:
                 (1) This device may not cause harmful interference, and
                 (2) This device must accept any interference received, including interference that may cause
                 undesired operation.”




Landis+Gyr Confidential Information                98-1289 Rev AA                                                 7


                          Draft 8/23/2013
Elster Multi-Function Meter Module Quick Start Guide                                                     Landis+Gyr


Product Specifications
                          Table 3. Elster Multi-Function Meter Module Specifications
                  Category         Specification                    Value or Range

                                                                    Form             Class

                                                                    1S               200

                                                                    1S               320

                                                                    2S               200

                                                                    2S               320

                                                                    3S               20

                                                                    4S               20

                                                                    35S              20

                                                                    35A              20

                                   Elster ALPHA Plus Supported      12S              200
                                   Meter Forms
                  Compatible                                        12S              320
                  Meters           NOTE: Contact Elster
                                                                    13S              200
                                         Electricity for
                                         additional forms.          13S              320

                                                                    13A              100

                                                                    36S              20

                                                                    36A              20

                                                                    9S               20

                                                                    10S              20

                                                                    10A              20

                                                                    16S              200

                                                                    16S              320

                                                                    16A              100

                                                                    13.5VDC + 1V, 50mA (limited
                                   Voltage                          duration from meter’s power
                  Electrical                                        supply)

                                   Input Current                    50mA

                                   Output Power                     22-26.5 dBm
                  RF
                                   Transmit Frequency               917.58 MHz (Fixed))




8                                                  98-1289 Rev AA                 Landis+Gyr Confidential Information


Landis+Gyr
                     Draft 8/23/2013                             Elster Multi-Function Meter Module Quick Start Guide


                         Table 3. Elster Multi-Function Meter Module Specifications
                  Category            Specification                    Value or Range

                                      FCC Title 47 CFR Part 15         Radiated and Conducted
                                      Subpart B & C                    Emissions

                                      IEC 61000 4-2,3,4,5              Electromagnetic Compatibility

                                      ANSI C12.1-2011                  Electricity Metering
                  Standards           ANSI C12.20-2002                 Electricity Meters Standard
                  Compliance
                                                                       Substation Standards - Fast
                                      ANSI C37.90.1                    Transient and Oscillatory
                                                                       Waveform

                                                                       Workmanship Standard for
                                      ANSI/IPC-A-610-Class 2
                                                                       Electronic Assemblies

                                                                       Outdoor, rain-protected,
                                      General Environmental
                                                                       sunlight-exposed

                                                                       -40 to +85 C (under meter
                  Environmental       Operating Temperature Range
                                                                       glass)

                                                                       10% to 95% relative humidity,
                                      Humidity
                                                                       non-condensing

                                                                       Refer to Elster Technical
                                      Size (Meter & Module)            Manual, TM42-2182E for more
                                                                       details.
                  Mechanical
                                                                       Refer to Elster Technical
                                      Weight (Meter & Module)          Manual, TM42-2182E for more
                                                                       details.




Landis+Gyr Confidential Information                   98-1289 Rev AA                                               9


                         Draft 8/23/2013
Elster Multi-Function Meter Module Quick Start Guide                                                    Landis+Gyr


Physical Dimensions
                 The ALPHA Plus meter fits all standard S-base services. Meters with an A-base are also available.
                 Figure 1 - 1 illustrates the S-base meter type and dimensions.

                NOTE: The dimensions are for reference purposes only and should not be used for construction.




                   Figure 1 - 1. S-base Meter Type and Dimensions in Inches (millimeters) - Front and Side View
                 Figure 1 - 2 and Figure 1 - 3 illustrate the A-base meter type and dimensions.




10                                                98-1289 Rev AA                 Landis+Gyr Confidential Information


Landis+Gyr
                     Draft 8/23/2013                        Elster Multi-Function Meter Module Quick Start Guide




                   Figure 1 - 2. A-base Meter Type and Dimensions in Inches (millimeters) - Front and Side View




                        Figure 1 - 3. A-base Meter Type and Dimensions in Inches (millimeters) - Back View




Landis+Gyr Confidential Information             98-1289 Rev AA                                                11


                         Draft 8/23/2013
Elster Multi-Function Meter Module Quick Start Guide                                    Landis+Gyr




12                                              98-1289 Rev AA   Landis+Gyr Confidential Information



Document Created: 2013-08-26 10:21:06
Document Modified: 2013-08-26 10:21:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC