TEST REPORT

FCC ID: R6U6024-49M

Test Report

Download: PDF
FCCID_696638

Test Report of FCC Part 15 C for FCC Certificate
                               On Behalf of

              YINRUN PLASTIC CRAFTS CO.,LTD



Product description:      R/C Airplane
Model No.:                6024
FCC ID:                   R6U6024-49M



Prepared for:   YINRUN PLASTIC CRAFTS CO.,LTD
                Yinrun Ind, Garden, Laimei, Zone,Chenghai,Shantou City,
                Guangdong, China
Prepared by:    Bontek Compliance Laboratory Ltd
                Rm 802~804, 8/F, Jinmin Bld., Zizhu 6th Rd.,Zhuzi Lin, Futian,
                Shenzhen 518040, P.R. China.
                Tel: 86-755-82871080        Fax: 86-755-82871368
Issue Date:     August 21, 2006

Test Date:      August 15 ~20, 2006


Test by:                               Reviewed By:




                    Kendy Wang                                  Tony Wu


TABLE OF CONTENTS
1. GENERAL INFORMATION............................................................................................................... 3
 1.1 Product Description for Equipment Under Test (EUT)............................................................ 3
  1.2 Related Submittal(s) / Grant (s) .............................................................................................. 3
  1.3 Test Methodology ................................................................................................................... 3
 1.4 Test Facility............................................................................................................................. 4
2. SYSTEM TEST CONFIGURATION .................................................................................................. 5
 2.1 EUT Configuration .................................................................................................................. 5
  2.2 EUT Exercise .......................................................................................................................... 5
  2.3 General Test Procedures........................................................................................................ 5
 2.4 List of Measuring Equipments Used ....................................................................................... 5
3. SUMMARY OF TEST RESULTS ...................................................................................................... 6
4. TEST OF CONDUCTED EMISSION ................................................................................................. 7
 4.1 Applicable Standard................................................................................................................ 7
 4.2 Test Setup Diagram ................................................................................................................ 7
5- RADIATED EMISSIONS ................................................................................................................... 8
 5.1 Limit of Radiated Emissions.................................................................................................. 8
  5.2 Test Equipment Used ............................................................................................................. 8
  5.3 EUT Setup .............................................................................................................................. 9
  5.4 Test Procedure ....................................................................................................................... 9
 5.5 Test Result............................................................................................................................ 10
6- OCCUPIED BANDWIDTH .............................................................................................................. 12
 6.1 Limit of Occupied Bandwidth ................................................................................................ 12
  6.2 Test Equipment Used ........................................................................................................... 12
  6.3 Test Procedure ..................................................................................................................... 12
  6.4 Occupied Bandwidth Test Result.......................................................................................... 12




Report No. BCT06H-029E                                                                                                             Page 2 of 13


1. GENERAL INFORMATION
  1.1 Product Description for Equipment Under Test (EUT)

  Applicant:                           YINRUN PLASTIC CRAFTS CO.,LTD
  Address of applicant:                Yinrun Ind, Garden, Laimei, Zone,Chenghai,Shantou City,
                                       Guangdong, China
  Manufacturer:                        YINRUN PLASTIC CRAFTS CO.,LTD
  Address of manufacturer:             Yinrun Ind, Garden, Laimei, Zone,Chenghai,Shantou City,
                                       Guangdong, China


  EUT Description:                     R/C Airplane
  Trade Name:                          N/A
  Model No.:                           6024
  Rated Voltage                        DC 9V (6 x1.5VAA alkaline battery) for Transmitter
  Frequency range                      49.86MHz
  Number of channels                   1
  Channel Separation                   None
  Product Class:                       Low Power Communication Device Transmitter
  Measurement Procedure                ANSI C63.4-2003

  Remark: * The test data gathered are from the production sample provided by the manufacturer.


  1.2 Related Submittal(s) / Grant (s)
  This submittal(s) is a test report based on the Electromagnetic Interference (EMI) tests performed
  on the EUT. The EMI measurements were performed according to the measurement procedure
  described in ANSI C63.4 - 2003.

  The tests were performed in order to determine compliance with FCC Part 15, Subpart C, section
  15.235 rules.


  1.3 Test Methodology

  Both conducted and radiated testing were performed according to the procedures in ANSI C63.4
  - 2003, American National Standard for Methods of Measurement of Radio-Noise Emissions from
  Low-Voltage Electrical and Electronic Equipment in the range of 9 kHz to 40 GHz. Radiated
  testing was performed at an antenna to EUT distance 3 meters.




Report No. BCT06H-029E                                                                      Page 3 of 13


  1.4 Test Facility

  All measurement required was performed at laboratory of Solid Industrial (Shenzhen) Co., Ltd. at
  333 Bulong Highway, Buji, Longgang, Shenzhen, Guangdong, China.

  The test facility is recognized, certified, or accredited by the following organizations:

  FCC – Registration No.: 759397

  Solid Industrial., Ltd, EMC Laboratory has been registered and fully described in a report filed
  with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is
  maintained in our files. Registration 759397, Nov 04, 2003.




Report No. BCT06H-029E                                                                        Page 4 of 13


2. SYSTEM TEST CONFIGURATION
  The tests documented in this report were performed in accordance with ANSI C63.4-2003 and
  FCC CFR 47 Part 15 Subpart C.


  2.1 EUT Configuration
  The EUT configuration for testing is installed on RF field strength measurement to meet the
  Commissions requirement and operating in a manner that intends to maximize its emission
  characteristics in a continuous normal application.


  2.2 EUT Exercise
  The calibrated antennas used to sample the radiated field strength are mounted on a non-
  conductive, motorized antenna mast 3 or 10 meters from the leading edge of the turntable.


  2.3 General Test Procedures
  Conducted Emissions The EUT is placed on the turntable, which is 0.8 m above ground plane.
  According to the requirements in Section 7.1 of ANSI C63.4-2003.Conducted emissions from the
  EUT measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-Peak
  detector mode.

  Radiated Emissions The EUT is a placed on as turntable, which is 0.8 m above ground plane.
  The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT
  is set 3m away from the receiving antenna, which varied from 1m to 4m to find out the highest
  emission. And also, each emission was to be maximized by changing the polarization of receiving
  antenna both horizontal and vertical. In order to find out the maximum emissions, exploratory
  radiated emission measurements were made according to the requirements in Section 13.1.4.1 of
  ANSI C63.4-2003.


  2.4 List of Measuring Equipments Used

                                                                                   Calibration
     Items           Equipment        Manufacturer      Model No.       Last Cal     Period
       1          Spectrum Analyzer        HP             8594A          2006/8       1 year
       2          EMI Test Receiver       R&S              ESS           2006/8       1 year
       3             RF Selector          TOYO           NS4901A         2006/8       1 year
       4             Pre Amplifier       Anritsu         MH648A          2006/8       1 year
       5            Bilog Antenna        CHASE          CBL6111A         2006/8       1 year
       6                 Turn Disc         HD            DS4150S         2006/8       1 year
       7            Antenna Mast           HD            MA2400          2006/8       1 year




Report No. BCT06H-029E                                                                 Page 5 of 13


3. SUMMARY OF TEST RESULTS

    FCC Rules                    Description of Test                        Result
       15.207        Disturbance Voltage at The Mains Terminals   N/A, without AC power supply
       15.235                    Radiation Emission                           Pass
       15.235                   Occupied Bandwidth                            Pass




Report No. BCT06H-029E                                                               Page 6 of 13


4. TEST OF CONDUCTED EMISSION
  4.1 Applicable Standard

  Section 15.207: For a Low-power Radio-frequency Device is designed to be connected to the AC
  power line, the radio frequency voltage that is conducted back onto the AC power line on any
  frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed below limits table.

                                                           Limits ( dBuV)
      Frequency Range (MHz)
                                             Quasi-Peak                       Average
             0.150~0.500                        66~56                          56~46
             0.500~5.000                          56                              46
             5.000~30.00                          60                              50


  4.2 Test Setup Diagram




  Remark: 1. The setup of EUT is according with per ANSI C63.4-2003 measurement procedure.
            The specification used was with the FCC 15.207 limits.

             2. The EUT is exclused from investigation of Disturbance Voltage at The Mains
                Terminals, for it is powered by DC 9V (6 x1.5VAA alkaline) bettary. According to the
                Section 15.207(d),measurement to demonstrate compliance with the limits of
                Disturbance Voltage at The Mains Terminals are not required to the devices which
                only employed bettary power for operation and which do not operate from the AC
                power lines or contain provisions for operation while connected to the AC power lines.




Report No. BCT06H-029E                                                                    Page 7 of 13


5- RADIATED EMISSIONS
  5.1 Limit of Radiated Emissions

  Limits of Spurious Emissions (Fcc 47 Cfr 15.209 Class B):

               Frequency                     Distance                Field Strengths Limits
                 (MHz)                       (Meters)                       (dBµV/m)
                 30 ~ 88                        3                              40
                 88~216                         3                              43.5
                216 ~ 960                       3                              46
               960 ~ 1000                       3                              54

  Note: (1) The tighter limit shall apply at the edge between two frequency bands.
          (2) The emission limits shown in the above table are based on measurement employing a
              CISPR quasi-peak detector and above 1000MHz are based on measurements
              employing an average detector.


  5.2 Test Equipment Used

                                                                                     Calibration
         Equipment            Manufacturer          Model No.       Last Cal           Period
      EMI Test Receiver     ROHDE & SCHWARZ             ESS          2006/8            1 year
          RF Selector             TOYO              NS4901A          2006/8            1 year
         Pre Amplifier           Anritsu             MH648A          2006/8            1 year
        Bilog Antenna            CHASE              CBL6111A         2006/8            1 year
           Turn Disc               HD               DS4150S          2006/8            1 year
         Antenna Mast              HD                MA2400          2006/8            1 year




Report No. BCT06H-029E                                                                    Page 8 of 13


  5.3 EUT Setup
  Radiated Measurement Setup




  5.4 Test Procedure
  Maximizing procedure was performed on the highest emissions to ensure that the EUT complied
  with all installation combinations.

  1). Configure the EUT according to ANSI C63.4:2003.

  2). The EUT was placed on the top of the turntable 0.8 meter above ground.

  3). The receiving antenna was placed 3 meters far away from the turntable.

  4). The turntable was rotated by 360 degrees to determine the position of the highest radiation.

  5). For Spurious Emissions test, The height of the broadband receiving antenna was varied
      between one meter and four meters above ground to find the maximum emission field strength
      of both horizontal and vertical polarization. For each suspected emission, the antenna tower
      was scanned (from 1 M to 4 M) and then the turntable was rotated (from 0 degree to 360
      degrees) to find the maximum reading.




Report No. BCT06H-029E                                                                  Page 9 of 13


  5.5 Test Result

  Temperature ( ℃ ) : 22~23                           EUT: R/C Airplane
  Humidity (%RH ): 50~54                              M/N: 6024
  Barometric Pressure ( mbar ): 950~1000              Operation Condition: Continuous Transmitting

  Fundamental Emission Test Data

                                        Peak Measurement
      Test Frequency       Measuring Level (dBµV/m)         Limits                Margin (dB)
           (MHz)            Vertical     Horizontal       (dBµV/m)        Vertical        Horizontal
          49.8595             88.2          74.3            100            11.8                 25.7
                                       Average Measurement
          49.8595             77.8          69.5             80             2.2                 10.5

  Result: The field strength of any emission within the operation band did not exceed 80 dBµV/m
           for average value or 100 dBµV/m for peak value.




Report No. BCT06H-029E                                                                    Page 10 of 13


  Harmonics & Spurious Emission

                                    49.86MHz Spurious Emission

        Maximum                      Position and Level                   Limit       Margin
        Frequency
                                     Value                  Result
          (MHz)          Polarity              Transd                   dBµV/m        dBµV/m
                                    dBµV/m                 dBµV/m
           99.719           V        30.1       11.7         41.8         43.5          1.7
          149.579           V        19.7       10.8         30.5         43.5          13.0
          199.438           V        25.6       11.1         36.7         43.5          6.8
          249.296           V        26.5       12.9         39.4          46           6.6
          299.157           V        16.1       16.2         32.3          46           13.7
          349.016           V        13.1       20.3         33.4          46           12.6
          398.876           V        8.7        22.9         31.6          46           14.4
          448.736           V        12.6       23.2         35.8          46           10.2
          498.595           V        13.0       22.6         35.6          46           10.4
             ---           ---        ---        ---          ---          ---           ---

        Maximum                      Position and Level                   Limit       Margin
        Frequency
                                     Value                  Result
          (MHz)          Polarity              Transd                   dBµV/m        dBµV/m
                                    dBµV/m                 dBµV/m
           99.719           H        22.9       11.6         34.4         43.5          9.1
          149.579           H        15.6       10.9         26.5         43.5          17.0
          199.438           H        17.6       10.7         28.3         43.5          15.2
          249.296           H        13.8       12.5         26.3          46           19.7
          299.157           H        14.5       14.0         28.5          46           17.5
          349.016           H        9.4        20.5         29.9          46           16.1
          398.876           H        3.8        23.8         27.6          46           18.4
          448.736           H        3.9        24.2         28.1          46           17.9
          498.595           H        5.6        24.5         30.1          46           15.9
             ---           ---        ---        ---          ---          ---           ---
    Remark:
    --- Means that The emission level of the rest measuring harmonic up to 5GHz are so low below
        applicable limit in operation mode, so the result were not recorded.




Report No. BCT06H-029E                                                                 Page 11 of 13


6- OCCUPIED BANDWIDTH
  6.1 Limit of Occupied Bandwidth
  The field strength of any emissions appearing between the band edges and up to 10 kHz above
  and below the band edges shall be attenuated at least 26 dB below the level of the un-modulated
  carrier or to the general limits of 15.209, whichever permits the higher emission levels.


  6.2 Test Equipment Used

                                                                                   Calibration
         Equipment            Manufacturer          Model No.        Last Cal        Period
    Spectrum Analyzer              HP                 8594A           2006/8          1 year
          RF Selector             TOYO               NS4901A          2006/8          1 year
         Pre Amplifier           Anritsu             MH648A           2006/8          1 year
        Bilog Antenna            CHASE              CBL6111A          2006/8          1 year
           Turn Disc               HD                DS4150S          2006/8          1 year
         Antenna Mast              HD                 MA2400          2006/8          1 year



  6.3 Test Procedure
  Maximizing procedure was performed on the highest emissions to ensure that the EUT complied
  with all installation combinations.

  1). Configure the EUT according to ANSI C63.4:2003.

  2). The EUT was placed on the top of the turntable 0.8 meter above ground.

  3). The receiving antenna was placed 3 meters far away from the turntable.

  4). The turntable was rotated by 360 degrees to determine the position of the highest radiation.

  5). For Spurious Emissions test, The height of the broadband receiving antenna was varied
      between one meter and four meters above ground to find the maximum emission field
      strength of both horizontal and vertical polarization. For each suspected emission, the
      antenna tower was scanned (from 1 M to 4 M) and then the turntable was rotated (from 0
      degree to 360 degrees) to find the maximum reading.


  6.4 Occupied Bandwidth Test Result

  Temperature ( ℃ ) : 22~23                           EUT: R/C Airplane
  Humidity (%RH ): 50~54                              M/N: 6024
  Barometric Pressure ( mbar ): 950~1000              Operation Condition: Continuous Transmitting

  Test plots see following:




Report No. BCT06H-029E                                                                  Page 12 of 13


Report No. BCT06H-029E   Page 13 of 13



Document Created: 2006-08-22 21:31:46
Document Modified: 2006-08-22 21:31:46

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC