TEST REPORT

FCC ID: R6U-T9B-27M

Test Report

Download: PDF
FCCID_758437

Test Report of FCC Part 15 C for FCC Certificate
                               On Behalf of

              YINRUN PLASTIC CRAFTS CO.,LTD



Product description:      TOY-R/C MICRO CAR
Model No.:                T9B
FCC ID:                   R6U-T9B-27M



Prepared for:   YINRUN PLASTIC CRAFTS CO.,LTD
                Yinrun Ind, Garden, Laimei, Zone,Chenghai,Shantou City,
                Guangdong, China
Prepared by:    Bontek Compliance Laboratory Ltd
                Rm 802~804, 8/F, Jinmin Bld., Zizhu 6th Rd.,Zhuzi Lin, Futian,
                Shenzhen 518040, P.R. China.
                Tel: 86-755-82871080        Fax: 86-755-82871368
Issue Date:     February 12, 2007

Test Date:      February 04~09, 2007


Test by:                               Reviewed By:




                    Kendy Wang                                  Tony Wu


TABLE OF CONTENTS
1. GENERAL INFORMATION............................................................................................................... 3
 1.1 Product Description for Equipment Under Test (EUT) ............................................................ 3
  1.2 Related Submittal(s) / Grant (s) .............................................................................................. 3
  1.3 Test Methodology ................................................................................................................... 3
 1.4 Test Facility............................................................................................................................. 4
2. SYSTEM TEST CONFIGURATION .................................................................................................. 5
 2.1 EUT Configuration .................................................................................................................. 5
  2.2 EUT Exercise .......................................................................................................................... 5
  2.3 General Test Procedures........................................................................................................ 5
 2.4 List of Measuring Equipments Used ....................................................................................... 6
3. SUMMARY OF TEST RESULTS ...................................................................................................... 7
4. TEST OF CONDUCTED EMISSION ................................................................................................. 8
 4.1 Applicable Standard................................................................................................................ 8
 4.2 Test Setup Diagram ................................................................................................................ 8
5- RADIATED EMISSIONS ................................................................................................................... 9
 5.1 Limit of Radiated Emissions.................................................................................................. 9
  5.2 Test Equipment Used ............................................................................................................. 9
  5.3 EUT Setup ............................................................................................................................ 10
  5.4 Test Procedure ..................................................................................................................... 11
 5.5 Test Result............................................................................................................................ 11
6- EMISSIONS WITHIN BAND EDGES.............................................................................................. 15
 6.1 Limit of Emissions within Band Edges .................................................................................. 15
  6.2 Test Equipment Used ........................................................................................................... 15
  6.3 Test Procedure ..................................................................................................................... 15
  6.4 Emissions within Band Edges Test Result............................................................................ 15




Report No.: BCT07AR-032E                                                                                                           Page 2 of 16


1. GENERAL INFORMATION
  1.1 Product Description for Equipment Under Test (EUT)

  Applicant:                           YINRUN PLASTIC CRAFTS CO., LTD
  Address of applicant:                Yinrun Ind, Garden, Laimei, Zone,Chenghai,Shantou City,
                                       Guangdong, China
  Manufacturer:                        YINRUN PLASTIC CRAFTS CO., LTD
  Address of manufacturer:             Yinrun Ind, Garden, Laimei, Zone,Chenghai,Shantou City,
                                       Guangdong, China


  EUT Description:                     TOY-R/C MICRO CAR
  Trade Name:                          N/A
  Model No.:                           T9B
  Rated Voltage                        DC 6V (4 x1.5VAA alkaline battery) for Transmitter
  Frequency range                      27.151MHz
  Number of channels                   1
  Channel Separation                   None
  Product Class:                       Low Power Communication Device Transmitter
  Measurement Procedure                ANSI C63.4-2003

  Remark: * The test data gathered are from the production sample provided by the manufacturer.


  1.2 Related Submittal(s) / Grant (s)

  This submittal(s) is a test report based on the Electromagnetic Interference (EMI) tests performed
  on the EUT. The EMI measurements were performed according to the measurement procedure
  described in ANSI C63.4 - 2003.

  The tests were performed in order to determine compliance with FCC Part 15, Subpart C, section
  15.227 rules.


  1.3 Test Methodology

  Both conducted and radiated testing were performed according to the procedures in ANSI C63.4
  - 2003, American National Standard for Methods of Measurement of Radio-Noise Emissions from
  Low-Voltage Electrical and Electronic Equipment in the range of 9 kHz to 40 GHz. Radiated
  testing was performed at an antenna to EUT distance 3 meters.




Report No.: BCT07AR-032E                                                                    Page 3 of 16


  1.4 Test Facility

  All measurement required was performed at laboratory of Shenzhen Huatongwei International
  Inspection Co., Ltd at Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China and Solid Industrial
  (Shenzhen) Co., Ltd. at 333 Bulong Highway, Buji, Longgang, Shenzhen, Guangdong, China.

  The test facility is recognized, certified, or accredited by the following organizations:

  FCC – Registration No.: 662850

  Shenzhen Huatongwei International Inspection Co., Ltd, EMC Laboratory has been registered
  and fully described in a report filed with the (FCC) Federal Communications Commission. The
  acceptance letter from the FCC is maintained in our files. Registration 662850, November 17,
  2003.

  FCC – Registration No.: 759397

  Solid Industrial., Ltd, EMC Laboratory has been registered and fully described in a report filed
  with the (FCC) Federal Communications Commission. The acceptance letter from the FCC is
  maintained in our files. Registration 759397, Nov 04, 2003.




Report No.: BCT07AR-032E                                                                      Page 4 of 16


2. SYSTEM TEST CONFIGURATION
  The tests documented in this report were performed in accordance with ANSI C63.4-2003 and
  FCC CFR 47 Part 15 Subpart C.


  2.1 EUT Configuration

  The EUT configuration for testing is installed on RF field strength measurement to meet the
  Commissions requirement and operating in a manner that intends to maximize its emission
  characteristics in a continuous normal application.


  2.2 EUT Exercise

  The calibrated antennas used to sample the radiated field strength are mounted on a non-
  conductive, motorized antenna mast 3 or 10 meters from the leading edge of the turntable.


  2.3 General Test Procedures

  Conducted Emissions The EUT is placed on the turntable, which is 0.8 m above ground plane.
  According to the requirements in Section 7.1 of ANSI C63.4-2003.Conducted emissions from the
  EUT measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-Peak
  detector mode.

  Radiated Emissions The EUT is a placed on as turntable, which is 0.8 m above ground plane.
  The turntable shall rotate 360 degrees to determine the position of maximum emission level. EUT
  is set 3m away from the receiving antenna, which varied from 1m to 4m to find out the highest
  emission. And also, each emission was to be maximized by changing the polarization of receiving
  antenna both horizontal and vertical. In order to find out the maximum emissions, exploratory
  radiated emission measurements were made according to the requirements in Section 13.1.4.1 of
  ANSI C63.4-2003.




Report No.: BCT07AR-032E                                                               Page 5 of 16


  2.4 List of Measuring Equipments Used

                                                                                         Calibration
     Items           Equipment              Manufacturer         Model No.    Last Cal     Period
    Radiated Spurious Emission test: Solid Industrial., Ltd, EMC Laboratory
       1            EMC Analyzer                Agilent           E7402A       2006/8      1 year
       2          EMI Test Receiver              R&S                ESS        2006/8      1 year
       3             RF Selector                TOYO              NS4901A      2006/8      1 year
       4             Pre Amplifier              Anritsu           MH648A       2006/8      1 year
       5            Bilog Antenna              CHASE             CBL6111A      2006/8      1 year
       6               Turn Disc                  HD              DS4150S      2006/8      1 year
       7            Antenna Mast                  HD              MA2400       2006/8      1 year
    Other test: Shenzhen Huatongwei International Inspection Co., Ltd
                                              ROHDE &
       1          EMI Test Receiver                               ESCS30      2006/11      1 year
                                              SCHWARZ
                                              ROHDE &
       2          EMI Test Receiver                                ESI 26     2006/11      1 year
                                              SCHWARZ
                3m/5m Semi- Anechoic
       3                                         ETS                 N/A      2006/11      1 year
                     Chamber
       4            Loop Antenna                 R/S              HFH2-Z2     2006/11      1 year
       5            RF Test Panel                R/S              TS / RSP      N/A         N/A
       6               Turntable                 ETS                2088        N/A         N/A
       7            Antenna Mast                 ETS                2075        N/A         N/A




Report No.: BCT07AR-032E                                                                    Page 6 of 16


3. SUMMARY OF TEST RESULTS

    FCC Rules                       Description of Test                     Result
       15.207        Disturbance Voltage at The Mains Terminals   N/A, without AC power supply
       15.227              Radiation Emission                                 Pass
       15.227              Emissions within Band Edges                        Pass




Report No.: BCT07AR-032E                                                             Page 7 of 16


4. TEST OF CONDUCTED EMISSION
  4.1 Applicable Standard

  Section 15.207: For a Low-power Radio-frequency Device is designed to be connected to the AC
  power line, the radio frequency voltage that is conducted back onto the AC power line on any
  frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed below limits table.

                                                           Limits ( dBuV)
      Frequency Range (MHz)
                                             Quasi-Peak                       Average
             0.150~0.500                        66~56                          56~46
             0.500~5.000                          56                              46
             5.000~30.00                          60                              50


  4.2 Test Setup Diagram




  Remark: 1. The setup of EUT is according with per ANSI C63.4-2003 measurement procedure.
            The specification used was with the FCC 15.207 limits.

             2. The EUT is exclused from investigation of Disturbance Voltage at The Mains
                Terminals, for it is powered by DC 6V (4 x1.5VAA alkaline) bettary. According to the
                Section 15.207(d),measurement to demonstrate compliance with the limits of
                Disturbance Voltage at The Mains Terminals are not required to the devices which
                only employed bettary power for operation and which do not operate from the AC
                power lines or contain provisions for operation while connected to the AC power lines.




Report No.: BCT07AR-032E                                                                  Page 8 of 16


5- RADIATED EMISSIONS
  5.1 Limit of Radiated Emissions

  Limit of Field Strength of Fundamental Emissions (Fcc 47cfr 15.227):

                                       Field Strength of              Field Strength of
          Frequency Range            Fundamental Emission           Fundamental Emission
               (MHz)                        (Peak)                        (Average)
                                            (µV/m)                          (µV/m)
              26.96-27.28           100,000µV/m (100dBμV/m)         10,000µV/m (80dBμV/m)

  Limits of Spurious Emissions (Fcc 47 Cfr 15.209 Class B):

               Frequency                     Distance                Field Strengths Limits
                 (MHz)                       (Meters)                       (dBμV/m)
                 30 ~ 88                        3                              40
                 88~216                         3                              43.5
                216 ~ 960                       3                              46
               960 ~ 1000                       3                              54

  Note: (1) The tighter limit shall apply at the edge between two frequency bands.
          (2) The emission limits shown in the above table are based on measurement employing a
              CISPR quasi-peak detector and above 1000MHz are based on measurements
              employing an average detector.


  5.2 Test Equipment Used

                                                                                     Calibration
         Equipment            Manufacturer          Model No.       Last Cal           Period
        EMC Analyzer             Agilent             E7402A          2006/8            1 year
      EMI Test Receiver     ROHDE & SCHWARZ              ESS         2006/8            1 year
          RF Selector             TOYO              NS4901A          2006/8            1 year
         Pre Amplifier           Anritsu             MH648A          2006/8            1 year
         Bilog Antenna           CHASE              CBL6111A         2006/8            1 year
           Turn Disc               HD               DS4150S          2006/8            1 year
         Antenna Mast              HD                MA2400          2006/8            1 year
        Loop Antenna        ROHDE & SCHWARZ         HFH2-Z2         2006/11            1 year
      EMI Test Receiver     ROHDE & SCHWARZ             ESI 26      2006/11            1 year
        RF Test Panel       ROHDE & SCHWARZ         TS / RSP          N/A               N/A
           Turntable              ETS                   2088          N/A               N/A
        Antenna Mast              ETS                   2075          N/A               N/A




Report No.: BCT07AR-032E                                                                  Page 9 of 16


  5.3 EUT Setup

  Radiated Measurement Setup




Report No.: BCT07AR-032E       Page 10 of 16


  5.4 Test Procedure

  Maximizing procedure was performed on the highest emissions to ensure that the EUT complied
  with all installation combinations.

  1). Configure the EUT according to ANSI C63.4:2003.

  2). The EUT was placed on the top of the turntable 0.8 meter above ground.

  3). The receiving antenna was placed 3 meters far away from the turntable.

  4). The turntable was rotated by 360 degrees to determine the position of the highest radiation.

  5). For Spurious Emissions test, The height of the broadband receiving antenna was varied
      between one meter and four meters above ground to find the maximum emission field strength
      of both horizontal and vertical polarization. For each suspected emission, the antenna tower
      was scanned (from 1 M to 4 M) and then the turntable was rotated (from 0 degree to 360
      degrees) to find the maximum reading.

  6). For Field Strength of Fundamental Emissions test, Positioned the loop antenna with its plane
      vertical at the specified distance of 3 meters between its center and the EUT. The center of
      the loop antenna is set with 1m above the grounded plane. Then rotated about its vertical axis
      for finding out the maximum emission level of the EUT.


  5.5 Test Result

  Temperature ( ℃ ) : 22~23                             EUT: TOY-R/C MICRO CAR
  Humidity (%RH ): 50~54                                M/N: T9B
  Barometric Pressure ( mbar ): 950~1000                Operation Condition: Continuous Transmitting

  Fundamental Emission Test Data

                                          Peak Measurement
      Test Frequency       Measuring Level (dBµV/m)           Limits               Margin (dB)
           (MHz)            Vertical       Horizontal       (dBµV/m)       Vertical        Horizontal
          27.1512             81.8            72.1            100           18.2                 27.9
                                        Average Measurement
          27.1512             76.3            66.6             80            3.7                 13.4

  Remark: Duty Cycle Correction

  Each function key sends a different series of characters, but each packet period (15.65msec)
  never exceeds a series of 4 long (1.2msec) and 10 short (0.35msec) pulses. Assuming any
  combination of short and long pulses may be obtained due to encoding the worst case
  transmit duty cycle would be considered 4x1.2msec+10x0.35msec per 15.65msec =53%
  duty cycle. Figure A through C show the characteristics of the pulse train for one of these
  functions.



Report No.: BCT07AR-032E                                                                   Page 11 of 16


  Duty Cycle Correction = 20Log(0.53) = -5.51dB
  The following figures show the characteristics of the pulse train for one of these functions.

  So, the radiation(average)= 81.8+20*log(0.53)=76.3(dBµV/m)


  Result: The field strength of any emission within the operation band did not exceed 80(dBµV/m)
          for average value or 100 dB(dBµV/m)for peak value.




Report No.: BCT07AR-032E                                                                  Page 12 of 16


     ms                            Mon 2007 Feb 09 19:23/
          A_View   8_Blank MA 1.200 mo



DELTA MKR
1.200—ms




             Eomcs ow
                     i:




                                                       }    Lodia




                                  Euis                      2oX
                              m      f                 I


  Harmonics & Spurious Emission

                                              Spurious Emission

                                          Position and Level                    Limit         Margin
        Maximum
        Frequency                     Antenna    Value                Result
          (MHz)            Polarity    Height             Transd               dBµV/m        dBµV/m
                                         m      dBµV/m               dBµV/m

           54.302             V         1.4       26.9         8.2    35.1       40             4.9
           81.454             V         1.4       24.5     11.4       35.9       40             4.1
          108.605             V         1.2       21.7     11.5       33.2      43.5           10.3
          135.756             V         2.7       17.9     10.5       28.4      43.5           15.1
          162.907             V         2.4       18.8     10.9       29.7      43.5           13.8
          190.058             V         1.8       14.4     11.3       25.7      43.5           17.8
          217.209             V         1.4       9.8      13.4       23.2       46            22.8
          244.361             V         1.4       12.6     14.6       27.2       46            18.8
          271.512             V         1.2       10.7     14.7       25.4       46            20.6
             ---             ---        ---        ---         ---     ---       ---             ---

                                          Position and Level                    Limit         Margin
        Maximum
        Frequency                     Antenna    Value                Result
          (MHz)            Polarity    Height             Transd               dBµV/m        dBµV/m
                                         m      dBµV/m               dBµV/m

           54.302             H         1.3       14.0         8.3    22.3       40            17.7
           81.454             H         2.5       7.2      11.5       18.7       40            21.3
          108.605             H         3.1       4.2      11.8       16.0      43.5           27.5
          135.756             H         2.7       8.4      10.2       18.6      43.5           24.9
          162.907             H         1.4       9.5      11.3       20.8      43.5           22.7
          190.058            ---        ---        ---         ---     ---       ---             ---
          217.209            ---        ---        ---         ---     ---       ---             ---
          244.361            ---        ---        ---         ---     ---       ---             ---
          271.512            ---        ---        ---         ---     ---       ---             ---
             ---             ---        ---        ---         ---     ---       ---             ---
    Remark:
    --- Means that The emission level of the rest measuring harmonic up to 5GHz are so low below
        applicable limit in operation mode, so the result were not recorded.

Remark: The ‘Transd. ‘ in the above table is the Corrected Amplitude calculated by adding the
          Antenna Factor and Cable Factor, and subtracting the Amplifier Gain from the
          Amplitude reading. The basic equation is as follows:

           Transd. = Indicated Reading + Antenna Factor + Cable Factor - Amplifier Gain


Report No.: BCT07AR-032E                                                                Page 14 of 16


6- EMISSIONS WITHIN BAND EDGES
  6.1 Limit of Emissions within Band Edges
  According to the section 15.227 of FCC Part 15 Subpart C, The field strength of any emission
  within this band shall not exceed 10,000 microvolts/ meter at 3 meter. The emission limit in this
  paragraph is based on measurement instrumentation employing an average detector.


  6.2 Test Equipment Used

                                                                                    Calibration
         Equipment              Manufacturer         Model No.        Last Cal        Period
        Loop Antenna          ROHDE & SCHWARZ        HFH2-Z2          2006/11          1 year
      EMI Test Receiver       ROHDE & SCHWARZ          ESI 26         2006/11          1 year
        RF Test Panel         ROHDE & SCHWARZ        TS / RSP           N/A             N/A
           Turntable                ETS                2088             N/A             N/A
        Antenna Mast                ETS                2075             N/A             N/A


  6.3 Test Procedure

  Positioned the loop antenna with its plane vertical at the specified distance of 3 meters between
  its center and the EUT. The center of the loop antenna is set with 1m above the grounded plane.
  Then rotated about its vertical axis for finding out the maximum emission level of the EUT.
  (Details refer to the relevant sections of the standard ANSI C63.4-2003 ‘Methods of
  Measurement of Radio Noise Emissions from Low –Voltage Electrical and Electronic Equipment
  in the Range of 9KHz to 40GHz’.)

  Maximizing procedure was performed on the highest emissions to ensure that the EUT complied
  with all installation combinations.


  6.4 Emissions within Band Edges Test Result

  Temperature ( ℃ ) : 22~23                           EUT: TOY-R/C MICRO CAR
  Humidity (%RH ): 50~54                              M/N: T9B
  Barometric Pressure ( mbar ): 950~1000              Operation Condition: Continuous Transmitting

  Test plots see following:




Report No.: BCT07AR-032E                                                                 Page 15 of 16





Document Created: 2007-02-12 21:13:16
Document Modified: 2007-02-12 21:13:16