RF Exposure Report

FCC ID: R59CMJUNIOR

RF Exposure Info

Download: PDF
FCCID_4205992

                                                           RF Exposure Report

                       Report No.: SA181206C23

                            FCC ID: R59CMJUNIOR

                       Test Model: Cloud Master Jr.

                 Received Date: Dec. 06, 2018

          Date of Evaluation: Jan. 17, 2019

                     Issued Date: Jan. 19, 2019


                         Applicant: ECOLUMINA TECHNOLOGIES, INC.

                          Address: 6F-5, No.432 Sec.1, Keelung Rd., Xinyi Dist., Taipei City 11051, Taiwan.



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd, Wen Hwa Vil, Kwei Shan Dist., Taoyuan City
                                 33383, Taiwan (R.O.C)
            FCC Registration /
                                            788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set fo rth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.



Report No.: SA181206C23                                              Page No. 1 / 6                                              Report Format Version: 6.1.1


                                                               Table of Contents
Release Control Record ........................................................................................................................ 3
1         Certificate of Conformity ............................................................................................................. 4
2         General Information .................................................................................................................... 5
3         RF Exposure ............................................................................................................................... 5
    2.1      Limits for Maximum Permissible Exposure (MPE) ........................................................................ 5
    2.2      MPE Calculation Formula........................................................................................................... 5
    2.3      Classification ............................................................................................................................. 5
    2.4      Calculation Result of Maximum Conducted Power ....................................................................... 6




Report No.: SA181206C23                                          Page No. 2 / 6                                           Report Format Version: 6.1.1


                                         Release Control Record


Issue No.             Description                                        Date Issued
SA181206C23           Original Release                                   Jan. 19, 2019




Report No.: SA181206C23                     Page No. 3 / 6        Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Wireless IoT Gateway

              Brand: ECOLUMINA

        Test Model: Cloud Master Jr.

    Sample Status: Mass product

          Applicant: ECOLUMINA TECHNOLOGIES, INC.

Date of Evaluation: Jan. 17, 2019

         Standards: FCC Part 2 (Section 2.1091)

                          KDB 447498 D01 General RF Exposure Guidance v06
                          IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                              ,   Date:       Jan. 19, 2019
                                 Rona Chen / Specialist




     Approved by :                                               ,   Date:       Jan. 19, 2019
                              Dylan Chiou / Project Engineer




Report No.: SA181206C23                         Page No. 4 / 6                        Report Format Version: 6.1.1


2      General Information
This report is issued as a duplicate report to BV CPS report no.: SA180627C01. The difference compared
with original report is modifying product name of EUT. Due to no effect on RF exposure, the original
evaluation result is kept in this report.


3      RF Exposure
3.1      Limits for Maximum Permissible Exposure (MPE)

    Frequency Range           Electric Field     Magnetic Field       Power Density       Average Time
         (MHz)               Strength (V/m)      Strength (A/m)         (mW/cm2)            (minutes)
                              Limits For General Population / Uncontrolled Exposure
        0.3-1.34                  614                  1.63               (100)*                 30
                                                                                 2
         1.34-30                 824/f                2.19/f             (180/f )*               30
         30-300                   27.5                0.073                0.2                   30
        300-1500                   …                    …                 f/1500                 30
      1500-100,000                 …                    …                  1.0                   30
f = Frequency in MHz ; *Plane-wave equivalent power density



3.2      MPE Calculation Formula

Pd = (Pout*G) / (4*pi*r 2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
pi = 3.1416
r = distance between observation point and center of the radiator in cm



3.3      Classification

      The antenna of this product, under normal use condition, is at least 20cm away from the body of the user.
         So, this device is classified as Mobile Device.


2.1      Antenna Gain

WLAN 2.4GHz: PCB antenna with 3.6 dBi gain
Zigbee: PIFA antenna with 3.74 dBi gain




Report No.: SA181206C23                           Page No. 5 / 6                        Report Format Version: 6.1.1


3.4     Calculation Result of Maximum Conducted Power

                Frequency Band   Max Power     Antenna Gain   Distance   Power Density        Limit
      Band
                    (MHz)          (dBm)           (dBi)        (cm)       (mW/cm2)         (mW/cm2)
      WLAN         2412-2462        22.79             3.6       20           0.087              1.00

      Zigbee       2405-2480        4.77             3.74       20           0.001              1.00


Conclusion:
The formula of calculated the MPE is:
CPD1 / LPD1 + CPD2 / LPD2 + ……etc. < 1
CPD = Calculation power density
LPD = Limit of power density

WLAN 2.4GHz + Zigbee = 0.087 / 1.00 + 0.001 / 1.00 = 0.088
Therefore the maximum calculations of above situations are less than the “1” limit.


--- END ---




Report No.: SA181206C23                      Page No. 6 / 6                     Report Format Version: 6.1.1



Document Created: 2019-03-18 16:25:00
Document Modified: 2019-03-18 16:25:00

© 2024 FCC.report