Test Report

FCC ID: R38YL7560T

Test Report

Download: PDF
FCCID_2095334

Unilab(Shanghai) Co.,Ltd.
Report No. : UL20130826001-2                                                    Page 1 of 15




                 FCC Part 15B TEST REPORT

                Product Name : Coolpad Flo
                Model Name        : Coolpad 7560T




                                        Prepared for:
  Yulong Computer Telecommunication Scientific (Shenzhen) Co. LTD
     Hi-Tech Industry Park(North),Nanshan District, Shenzhen City,
                     Guangdong Province, P.R.C.



                                        Prepared by:
                        Unilab (Shanghai) Co., Ltd.
                    FCC 2.948 register number is 714465
         No. 1350, Lianxi Rd. Pudong New District, Shanghai, China
                           TEL: +86-21-50275125
                           FAX: +86-21-50275126




                Report Number       :   UL20130826001-2
                Date of Report      :   2013-09-03
                Date of Test        :   2013-08-26~2013-09-03



Notes:
The test results only relate to these samples which have been tested.
Partly using this report will not be admitted unless been allowed by Unilab.
Unilab is only responsible for the complete report with the reported stamp of Unilab.


                                                                              Unilab
                                                                                 ®

Unilab(Shanghai) Co.,Ltd.
Report No. : UL20130826001—2                                                Page 2 of 15



Applicant:           Yulong Computer Telecommunication Scientific (Shenzhen) Co. LTD
                     Park(North),Nanshan District, Shenzhen City, Guangdong Province,
                     P.R.C.
Manufacturer:        Yulong Computer Telecommunication Scientific (Shenzhen) Co. LTD

                     Park(North),Nanshan District, Shenzhen City, Guangdong Province,
                     P.R.C.
Product Name:        Coolpad Flo

Brand Name:          Coolpad
Model Name:          Coolpad 7560T
FCC ID:              R3SYL756OT

IC ID:               10367A—YL7560T

EUT Voltage:         AC input: AC 100~240V 50/60Hz
                     Battery: 3.6V~4.2V
Date of Receipt:     2013—08—26
Test Standard:       FCC CFR Tile 47 Part 15 Subpart B

Test Result:         Complied
Date of Test         2013—08—26~2013—09—03



               Prepared by :             g            /ME?
                                   (Technical Engineer: Flame Wang)


               Reviewed by :
                                             F@f@s& (ad
                                     (Senior Engineer: Forest Cao)
                                             z
                                            /A Wom } /
                                            O 7   aA
               Approved by :                             )
                                        (Supervisor: Eva Wang)


Unilab(Shanghai) Co.,Ltd.
Report No. : UL20130826001-2                                                                                  Page 3 of 15



                                          TABLE OF CONTENTS
1.  TECHNIACL SUMMARY ...................................................................................... 4
    1.1    SUMMARY OF STANDARDS AND TEST RESULTS ............................... 4
    1.2    TEST UNCERTAINTY................................................................................ 4
    1.3    TEST EQUIPMENT LIST ........................................................................... 4
    1.4    SUPPORT EQUIPMENT ............................................................................ 5
    1.5    TEST FACILITY ......................................................................................... 5
    1.6    TEST SETUP CONFIGURATION .............................................................. 5
2.  CONDUCTED DISTURBANCE ............................................................................ 6
    2.1    TEST SETUP ............................................................................................. 6
    2.2    LIMITS........................................................................................................ 6
    2.3    TEST PROCEDURE .................................................................................. 6
    2.4    TEST RESULT ........................................................................................... 7
3.  RADIATED DISTURBANCE (RE) ........................................................................ 9
    3.1    TEST SETUP ............................................................................................. 9
    3.2    LIMITS........................................................................................................ 9
    3.3    TEST PROCEDURE ................................................................................ 10
    3.4    TEST RESULT ......................................................................................... 11
APPENDIX 1       PHOTOGRAPHS OF TEST SETUP.............................................. 15
APPENDIX 2       PHOTOGRAPHS OF EUT ............................................................ 15


Unilab(Shanghai) Co.,Ltd.
Report No. : UL20130826001-2                                                                Page 4 of 15



1. TECHNIACL SUMMARY
1.1 SUMMARY OF STANDARDS AND TEST RESULTS
The EUT have been tested according to the applicable standards as referenced below:
                          Test Item                         FCC                    Result

             Conducted disturbance              FCC 15.107                           P

             Radiated disturbance               FCC 15.109                           P

Note: P means pass, F means failure, N/A means not applicable

1.2 TEST UNCERTAINTY
Where relevant, the following test uncertainty levels have been estimated for tests
performed on the EUT as specified in CISPR 16-4-2. This uncertainty represents an
expanded uncertainty expressed at approximately the 95% confidence level using a
coverage factor of k=2.
                              Test item                     Value (dB)
                        Conducted disturbance                   3.4
                        Radiated disturbance                    4.2

1.3 TEST EQUIPMENT LIST
                        Shielding Room No. 3 - Conducted disturbance Test
         Equipment             Manufacturer         Model             Serial No.         Due Date
           Receiver               Agilent          N9038A         MY51210142             2013/09/28
            LISN                      R&S          ENV216              100069            2014/06/23


                      3m Semi-anechoic Chamber - Radiated disturbance Test
        Equipment              Manufacturer         Model             Serial No.         Due Date
       3m Chamber &
                              ETS-LINDGREN         FACT-3          CT-0000336            2013/11/27
    Accessory Equipment
         Receiver                 Agilent          N9038A         MY51210142             2013/09/28
      Biconilog Antenna      SCHWARZBECK         VULB 9160              3316             2013/09/20
        Horn Antenna         SCHWARZBECK         BBHA9120D            00057407           2013/09/20
    Microwave Preamplifier     EM Electronics     EM30180          3008A02425            2014/03/01
The measuring equipment utilized to perform the tests documented in this report has been
calibrated once a year or in accordance with the manufacturer's recommendations, and has
been calibrated by accredited calibration laboratories.


Unilab(Shanghai) Co.,Ltd.
Report No. : UL20130826001-2                                                             Page 5 of 15



1.4 SUPPORT EQUIPMENT
    Equipment     Manufacturer        Model                    Serial No.               Due Date
         PC           DELL        VOSTRO 260                   7JXLB3X                       /
     Displayer        DELL           E1910Hc        CN-0CD1MT-64180-OC7-06TS                 /
       Mouse          DELL           MS111-P         CN-0MF3JY-71581-2C7-05GB                /
     Keyboard         DELL           KB212-B       CN-0Y88XT-65890-22L-01MG-A01              /
      Adapter          JHC        JHC-A01-1A0                       /                        /

1.5 TEST FACILITY
All test facilities used to collect the test data are located at No. 1350, Lianxi Rd. Pudong New
District, Shanghai, China. The site and apparatus are constructed in conformance with the
requirements of ANSI C63.4: 2009, CISPR 16-1-1 and other equivalent standards. The
laboratory is compliance with the requirements of the ISO/IEC/E 17025.

1.6 TEST SETUP CONFIGURATION
See test photographs attached in Appendix 1 for the actual connections between EUT and
support equipment.
Notes:
1. All the equipment/cables were placed in the worst-case configuration to maximize the emission during
the test.
2. Grounding was established in accordance with the manufacturer’s requirements and conditions for the
intended use.
3. All the tests were carried out with the EUT in normal operation. Which was shown in this test
report is the worst test mode.


Unilab(Shanghai) Co.,Ltd.
Report No. : UL20130826001-2                                                              Page 6 of 15



2. CONDUCTED DISTURBANCE
2.1 TEST SETUP
For mains port:




2.2 LIMITS
                                  Limits for Class B digital devices
                                                          Limits
           Frequency range
                                                          dB(μV)
                (MHz)
                                          Quasi-peak                       Average
              0,15 to 0,50                  66 to 56                       56 to 46
                0,50 to 5                      56                             46
                 5 to 30                       60                             50
NOTE: 1. The lower limit shall apply at the transition frequencies.
      2. The limit decreases linearly with the logarithm of the frequency in the range 0.15 to 0.50 MHz.

2.3 TEST PROCEDURE
For mains port:
a. The EUT and support equipment were placed on a nonconductive table 0.8m above the
horizontal ground reference plane, and 0.4 m from the vertical ground reference plane. The
EUT connected to the main through Line Impedance Stability Network (L.I.S.N) to provide a
50 /50uH coupling impedance for the measuring equipment. The support equipment is
also connected to the main power through a LISN that provides a 50 /50uH coupling
impedance with 50  terminations. Both sides of AC line (Line & Neutral) were checked to
find out the maximum conducted emission.
b. The RBW of the receiver was set at 9 kHz. The frequency range from 150 kHz to 30 MHz
was checked. Run the receiver’s pre-scan to record the maximum disturbance generated
from EUT in all power lines in the full band.
c. For each frequency whose maximum record was higher or close to limit, measure its QP
and AVG values and record.


Unilab(Shanghai) Co.,Ltd.
Report No. : UL20130826001-2             Page 7 of 15



2.4 TEST RESULT
For mains port:
Test mode:               Data exchange


Unilab(Shanghai) Co., Lid                                                                                                         Unilab
Report No. : UL20130826001—2                                                                                                     Page 8 of 15
                   Level @Bu)
              zo
                   \—_IM&
              s




                      {                                                                                                  Fee prs class.Bav
              s




                                     2                                                                                       6
              &
              s
              3
              3


                   A6 2                          5            1                            2               5            10         20        30
                                    Frequency (Miz)
Site         : shielded room 3
Condition    _: FCC P15 CLASS—B (QP) ENV216(N)—20120730 NEUTRAL
Eut             Coolpad Flo
Model Name      Coolpad 7560T
Temp/Humi.      24 °C / 57%
Power Rating: DC 3.7V
Mode         : data exchange
Memo
                                          ReadAntenna       Cable Preanp                               Limit    Over
                          Freq           Level Factor         Loss Factor                      Level    Line   Limit Remark
                           Wiz             dBn       dB/m         d8               dB          dBn/m   dBn/m      dB
                                19       35.75   10.33        0.23                             46.31. 64.02    —17.71   Peak
                                28       32.72   10.43        0.19                             43.34 60.68     —17.34   Peak
                                56       32.92   10.38       .11                               43.41. 56.00    —12.59   Peak
                               .04       29.42   10.31.      0.14                              39.8756.00      —16.13   Peak
                                40       31.88   10.32        0.15                             42.3556.00      —13.65   Peak
                                co       32.60   10.45       0.39                              43.44 60.00     —16.56   Peak




 a uie w ie
                      Pursee
                                                                       s 0999 0
                                                                                  ssssss


Unilab(Shanghai) Co.,Ltd.
Report No. : UL20130826001-2                                                        Page 9 of 15



3. RADIATED DISTURBANCE (RE)
3.1 TEST SETUP
30MHz ~ 1GHz:




Above 1GHz:




3.2 LIMITS
                                Limits for Class B digital devices
                                                           limits at 3m
              Frequency (MHz)
                                                             dB(μV/m)

                    30-88                                     40.0
                   88-216                                     43.5
                   216-960                                    46.0
                 Above 960                                    54.0
NOTE: 1. The lower limit shall apply at the transition frequency.
        2. The limits shown above are based on measuring equipment employing a CISPR quasi-peak
detector function for frequencies below or equal to 1000MHz.
        3. The limits shown above are based on measuring equipment employing an average detector
function for frequencies above 1000MHz.


Unilab(Shanghai) Co.,Ltd.
Report No. : UL20130826001-2                                                   Page 10 of 15



3.3 TEST PROCEDURE
30MHz ~ 1GHz:
a. The EUT and support equipment were placed on the non-conductive turntable 0.8m
above the horizontal metal ground plane at a chamber. The EUT was set 3 meters away
from the receiving antenna, which was mounted on an antenna tower. Broadband antenna
(Calibrated Bilog Antenna) was used as receiving antenna.
b. The frequency range from 30MHz to 1GHz was checked. The RBW of the receiver was
set at 120kHz. Set the receiver in Peak detector, Max Hold mode. Record the maximum field
strength of all the pre-scan process in the full band when the antenna is varied between 1~4
m in both horizontal and vertical, and the turntable is rotated from 0 to 360 degrees.
c. For each frequency whose maximum record was higher or close to limit, measure its QP
value: vary the antenna’s height and rotate the turntable from 0 to 360 degrees to find the
height and degree where EUT radiated the maximum emission, then set the test frequency
receiver to QP Detector and record the maximum value.
Above 1GHz:
a. The EUT and support equipment were placed on the non-conductive turntable 0.8m
above the ground at a chamber. The EUT was set 3 meters away from the receiving
antenna, which was mounted on an antenna tower. Horn antenna was used as receiving
antenna.
b. The frequency range above 1GHz was checked. The RBW of the receiver was set at
1MHz. Set the receiver in Peak detector, Max Hold mode. Record the maximum field
strength of all the pre-scan process in the full band when the antenna is 1m and varied in
both horizontal and vertical, and the turntable is rotated from 0 to 360 degrees.
c. For each frequency whose maximum record was higher or close to limit, measure its
Average value: rotate the turntable from 0 to 360 degrees to find the degree where EUT
radiated the maximum emission, then set the test frequency receiver to EMI Average
Detector and record the maximum value.


Unilab(Shanghai) Co.,Ltd.
Report No. : UL20130826001-2              Page 11 of 15



3.4 TEST RESULT
30MHz ~ 1GHz:
Test mode:                Data exchange


Unilab(Ghanghai) Co.,Ltd                                                                                                 Unilab
Report No. : UL20130826001—2                                                                                          Page 12 of 15
                   Level (@Bu¥im)
              3
              s




                                                                                                                      ree class8
                                                                                                                              a8
              s
              &
              s
              3

                                    200.      300.               400.        500.      600.        700.        800.    800.   toco
                                                                         Frequency (MKz)
Site                        #f chanber
Condition                   .:   FCC CLASS—B 3m VULB916@ HORTZONTAL
EuT                              Coolpad Flo
Model. Name                 : Coolpad 7560T
Temp/Humi.                       2s °C / se ®
Power Ratin                      pe 3.7V
Mode                             data exchange
Memo
                                   ReadAntenna        Cable Preanp                        Limit       Over
                                  Level Factor         Loss Factor               Level      Line     Limit Remark
                                     dn      dB/m                d8              dBn/m    dBn/m           dB
                                                                          a
                                                                          &

                      96.93       21.74      9.91                .24             32.89        43.50 —10.61 Peak
                     240.49       21.25     11.71                42              35.08        46.00 —10.92 Peak
                     284.14       16.06     12.89                .23             31.18    46.00 —14.82 Peak
                     480.08       14.21     16.89                .00             34.10    46.00 —11.90 Peak
              pp     767.20       11.78     2139                 .71             36.88    46.00      —9.12 Peak
                     890.39         9.73°   22.38                .02             36.13    46.00      —9.87 Peak




 a ie un ce
                                                     > w wiy n
                                                                        sesses
                                                                        ssssss


Unilab(Shanghai) Co.,Ltd.
Report No. : UL20130826001-2              Page 13 of 15



Above 1GHz:
Test mode:                Data exchange


           Level (@Bu¥im)
                                                                                                Foc CLASs—8 PK
      70


      co
                                                                                                FCC CLASS—8 AV
      5o


      40


      30

      20


      10


       “‘1000               4000      6000.            8000.     10000,      12000.   14000.     16000.   18000
                                                          Frequency (MKz)
Site         :         chamber
Condition :            FCC CLASS—8 PK 3m BBHAO120D(942) VERTICAL
gut          :         Coolpad Flo
Model Name _:          Coolpad 7560T
Temp/Humi :            25 °C / 56 %
Power Rating:          DC 3.7V
Mode         :         data exchange
Memo
                      ReadAntenna Cable Preanp      Limit Over
                Freq Level Factor Loss Factor Level   Line Limit Remark
                 Wiz         dom    d8/m         d8            dB dBn/m don/m         d8
  1         1595.00     56.98      24.98       5.71      38.46    49.21     74.00 —24.79 Peak
  2         2462.00     5.27       27.49        7.39     38.32    46.83     74.00 —27.17 Peak
 3          2089.00 48.40 28.47 8.06 38.11 46.82 74.00 —27.18 Peak
 4          7205.00 37.61 36.47 12.73 37.01 49.80 74.00 —24.20 Peak
  5        10826.00     31.54      40.03      15.68      38.98    48.27     74.00 —25.73 Peak
  6 pp 14328.00 27.08 42.37 19.05 38.38 50.12 74.00 —23.88 Peak


Unilab(Shanghai) Co.,Ltd.
Report No. : UL20130826001-2                                          Page 15 of 15



               APPENDIX 1        PHOTOGRAPHS OF TEST SETUP

Please refer to the file named “R38YL7560T_Part15B Setup Photos”.


                     APPENDIX 2       PHOTOGRAPHS OF EUT

Please refer to the two files named “R38YL560T_External Photos” and
“R38YL560T_INternal Photos”.


                               ----End of the report----



Document Created: 2013-10-17 05:11:39
Document Modified: 2013-10-17 05:11:39

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC