RF exposure info

FCC ID: QZC-RFMD-01

RF Exposure Info

Download: PDF
FCCID_3263425

      FCC Part 1 Subpart I
      FCC Part 2 Subpart J

RF EXPOSURE EXCLUSION REPORT

   WIRELESS TRANSMITTER

    MODEL NUMBER: RFMD

     FCC ID: QZC-RFMD-01

  REPORT NUMBER: 10583303D

   ISSUE DATE: April 26, 2016

           Prepared for
  Elster American Meter Co LLC
        2221 Industrial Rd
          Nebraska City
       NE, 68410-6886, USA

          Prepared by
            UL LLC
       333 Pfingsten Rd.
      Northbrook, IL 60062
      TEL: (847) 272-8800




    NVLAP Lab code: 100414-0


REPORT NO: 10583303D                                                                         DATE: April 26, 2016
FCC ID: QZC-RFMD-01
                                               Revision History


           Issue
 Rev.      Date            Revisions                                                                Revised By
           2016-
   --                      Initial Issue                                                            VS
           04-26




                                                  Page 2 of 6
UL LLC                                                                                   FORM NO: CCSUP4701I
333 Pfingsten Rd., Northbrook, IL 60062, USA                                                TEL: (847) 272-8800
            This report shall not be reproduced except in full, without the written approval of UL LLC.


REPORT NO: 10583303D                                                                                                 DATE: April 26, 2016
FCC ID: QZC-RFMD-01
                                                 TABLE OF CONTENTS
1.     ATTESTATION OF TEST RESULTS .................................................................................... 4

2.     TEST METHODOLOGY ........................................................................................................ 5

3.     REFERENCES ...................................................................................................................... 5

4.     FACILITIES AND ACCREDITATION .................................................................................... 5

5.     STANDALONE SAR TEST EXCLUSION CONSIDERATIONS............................................ 6
     5.1.    FCC ................................................................................................................................ 6




                                                                 Page 3 of 6
UL LLC                                                                                                          FORM NO: CCSUP4701I
333 Pfingsten Rd., Northbrook, IL 60062, USA                                                                       TEL: (847) 272-8800
                 This report shall not be reproduced except in full, without the written approval of UL LLC.


REPORT NO: 10583303D                                                                         DATE: April 26, 2016
FCC ID: QZC-RFMD-01

1. ATTESTATION OF TEST RESULTS
COMPANY NAME:                     Elster American Meter Co LLC
                                  2221 Industrial Rd
                                  Nebraska City, NE, 68410-6886, USA

EUT DESCRIPTION:                  902-928MHz transceiver

MODEL:                            RFMD

SERIAL NUMBER:                    None

DATE TESTED:                      September 10, 2015 to April 5, 2016

                                       APPLICABLE STANDARDS
                            STANDARD                                                 TEST RESULTS
         FCC PART 1 SUBPART I & PART 2 SUBPART J                                            Pass


 UL Verification Services Inc. calculated the RF Exposure of the above equipment in
accordance with the requirements set forth in the above standards, using test results reported in
the test report documents referenced below and/or documentation furnished by the applicant.
All indications of Pass/Fail in this report are opinions expressed by UL Verification Services Inc.
based on interpretations of these calculations. The results show that the equipment is capable
of demonstrating compliance with the requirements as documented in this report.

Note: The results documented in this report apply only to the tested sample, under the
conditions and modes of operation as described herein. This document may not be altered or
revised in any way unless done so by UL Verification Services Inc. and all revisions are duly
noted in the revisions section. Any alteration of this document not carried out by UL Verification
Services Inc. will constitute fraud and shall nullify the document. This report must not be used
by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any
agency of the Federal Government, or any agency of any government.

Approved & Released For
UL LLC By:                                                    Tested By:




Vincent Sabalvaro                                             Bart Mucha
EMC Engineer                                                  Staff Engineer
UL LLC                                                        UL LLC




                                                  Page 4 of 6
UL LLC                                                                                   FORM NO: CCSUP4701I
333 Pfingsten Rd., Northbrook, IL 60062, USA                                                TEL: (847) 272-8800
            This report shall not be reproduced except in full, without the written approval of UL LLC.


REPORT NO: 10583303D                                                                         DATE: April 26, 2016
FCC ID: QZC-RFMD-01

2. TEST METHODOLOGY
All calculations were made in accordance with FCC KDB “447498 D01 General RF Exposure
Guidance v06”.


3. REFERENCES

Output power, Duty cycle and Antenna gain data is excerpted from the applicable test reports.


4. FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 333 Pfingsten
Road, Northbrook, IL 60062 USA.

UL NBK is accredited by NVLAP, Laboratory Code 100414-0. The full scope of accreditation
can be viewed at http://ts.nist.gov




                                                  Page 5 of 6
UL LLC                                                                                   FORM NO: CCSUP4701I
333 Pfingsten Rd., Northbrook, IL 60062, USA                                                TEL: (847) 272-8800
            This report shall not be reproduced except in full, without the written approval of UL LLC.


REPORT NO: 10583303D                                                                           DATE: April 26, 2016
FCC ID: QZC-RFMD-01
5. STANDALONE SAR TEST EXCLUSION CONSIDERATIONS
    5.1.          FCC
SAR test exclusion in accordance with KDB 447498.

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance, mm)]·[√f(GHz)] ≤ 3.0, for
1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
        f(GHz) is the RF channel transmit frequency in GHz
        Power and distance are rounded to the nearest mW and mm before calculation
        The result is rounded to one decimal place for comparison
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is <
5 mm, a distance of 5 mm is applied to determine SAR test exclusion.

SAR Exclusion Calculations Table for Portable Devices (separation distance < 20cm)

                                                  Average Output
    Antenna            Tx       Frequency              power                 Separation     Calculated
                                  (MHz)           dBm        mW            distances (mm) Threshold Value
     *Main            FHSS         902            1.16       1.31                 5            0.25
     **Main           FHSS         902            1.56       1.43                 5            0.27
* Initial power measured during EMC testing where settings adjusted to put out maximum power.
** Accounting for additional +0.4dB based on power tolerance reported by the manufacurer.



Conclusion:
The computed value is < 3; therefore, this device qualifies for Standalone SAR test exclusion




                                            END OF REPORT




                                                    Page 6 of 6
UL LLC                                                                                     FORM NO: CCSUP4701I
333 Pfingsten Rd., Northbrook, IL 60062, USA                                                  TEL: (847) 272-8800
              This report shall not be reproduced except in full, without the written approval of UL LLC.



Document Created: 2017-12-21 00:53:59
Document Modified: 2017-12-21 00:53:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC