Users Manual

FCC ID: QZC-ELIR1

Users Manual

Download: PDF
FCCID_2958583

                                                                                                             DRAFT




Litenode™ wireless node
Single load RME-GEN



Installation instructions
IL42-5047A



Description
Part of the DimOnOff wireless control technology, Litenode relays are suitable for general purpose
lighting control applications that add intelligent functions and networkability to any light fixture. The
relay provides continuous retroactive 0 V to 10 V (sink/source) for all types of ballasts and drivers and
provide power to external sensors (optional).
• intelligent distributed control, metering, and monitoring
• NEMA C136-41
• 5- and 7-pin with continuous retroactive 0 V to 10 V dimming


Operation
Unless otherwise programmed, the relay will turn on the fixture approximately 10 seconds after power
is restored to the relay.
The yellow LED will blink when power is properly applied.
Using DimOnOff software, test the communications link with the relay.


Before you install
• This device is to be installed and/or used in accordance with appropriate electrical codes and
  regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• Use this device only with NEMA C136-41 or C136-10 certified receptacles.




Use authorized utility procedures to install or service this device. Dangerous voltages are present.
Disconnect power at the circuit breaker or fuse when servicing, installing, or removing the light fixture.
Equipment damage, personal injury, or death may result if safety precautions are not followed.


                                                                                                                DRAFT

Litenode™ wireless node                                             2



Installation


Use authorized utility procedures to install or service this device. Dangerous voltages are present.
Disconnect power at the circuit breaker or fuse when servicing, installing, or removing the light fixture.
Equipment damage, personal injury, or death may result if safety precautions are not followed.




If you are uncertain about any part of these instructions, consult a qualified electrician.




The node input and output are low voltage (24 VDC). Consult local building codes and regulations for
information regarding low-voltage installation.


1 To avoid fire, shock, or death, be sure to turn off power at the circuit breaker or fuse. Verify that power
  is off before proceeding.
2 Connect lead wires according to the wiring diagram as follows:
  - Line voltage wiring: Remove 5/8-inch (1.6 cm) of insulation from each circuit conductor. Make sure
    that the ends of the conductors are straight. Connect lead wires from relay to line per the
    appropriate wiring diagram as follows. Twist strands of each lead tightly and, with circuit
    conductors, push firmly into the appropriate wire connector. Screw connectors on clockwise
    making sure that no bare conductor shows below the wiring connectors. Secure each connector
    with electrical tape.
  - Class II warning: Connect low-voltage wires from relay to fixture per appropriate wiring diagram
    as follows. Twist strands of each lead tightly, and with circuit conductors, push firmly into
    appropriate wire connector. Screw connectors on clockwise, making sure that no bare conductor
    shows below the wire connectors. Make sure to cap-off unused low-voltage wires. Secure each
    connector with electrical tape.
3 Restore power at circuit breaker or fuse.

                                              RME-GEN wiring

                              Line wires on C-136 socket supplied by others

                                                    Color                              Gauge
Line in                                             Black                                 14
Neutral/line 2                                     White                                  14
Line out                                            Red                                   14
                          DC control wires on C-136 socket supplied by others
0 V to 10 V+ out                                   Purple                                 18
0 V to 10 V- ground out                             Gray                                  18
Digital in 13 VDC to 30 VDC                       Orange                                  18
VCC 24 VDC 50 mA                                   Brown                                  18


                                                                                                             DRAFT

Litenode™ wireless node                                           3



Antenna location and installation
The antenna for the model ELIR1 Lightnode relay is integral to the unit and is contained wholly within the
device itself. It is not accessible to the user and may not be modified in any way.
To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation of 20 cm or
more should be maintained between the antenna of this device and persons during device operation.
To ensure compliance, operations at closer distance than 20 cm is not recommended.


Troubleshooting

General
• Make sure the wires are connected according to the wiring diagram.
• Make sure the wires have proper contact and are securely connected.
• If no LEDs are lit, then check the power.
Lights won’t turn on when relay is being powered:
• Make sure the wires are properly connected.
• Make sure the yellow LED is blinking.
Light won’t turn off after command has been sent:
• Make sure that relay is receiving communication (red LED blinks)
Relay doesn’t respond to commands:
• Make sure no obstacle (concrete, metal, etc.) is present between relay antenna and the emitter.
LED indicators:
• Yellow: blinks every 3 seconds to indicate that relay is powered and functioning normally
• Red: flashes to indicate message reception
• Green: flashes to indicate message transmission by the relay.
If there is no message reception/transmission, then possible causes are antenna positioning and
distance from another relay or the gateway.


Specifications
• Model: ELIR1
• IC: 4557A-ELIR1
• FCC ID: QZC-ELIR1
• Operating range: 110 VAC to 480 VAC 50 Hz or 60 Hz
• Max output: 8 A (2 A at 480 V)
• Inputs: 1 digital (0 VDC to 30 VDC), optional
• Output: 24 VDC 50 mA max
• Continuous retroactive 0 V to 10 V dimming
See the product data sheet for complete details


                                                                                                                                                                            DRAFT

Litenode™ wireless node                                                                            4


WARNING (PART 15.21)
Changes or modifications not expressly approved by Elster could void the user's authority to operate the equipment.
This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause undesired operation.
COMPLIANCE STATEMENT (FCC PART 15.19 AND INDUSTRY CANADA)
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may
not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
ÉNONCÉ DE CONFORMITÉ
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux
deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.



LiteNode is a trademark and/or registered trademark of DimOnOff Installation information obtained from DimOnOff and is used by permission of
DimOnOff.




DISCLAIMER OF WARRANTIES AND LIMITATIONS OF LIABILITY
There are no understandings, agreements, representations, or warranties either express or implied, including warranties of merchantability or fitness
for a particular purpose, other than those specifically set out by any existing contract between the parties. Any such contract states the entire
obligation of the seller. The contents of this document shall not become part of or modify any prior existing agreement, commitment, or relationship.
The information, recommendations, descriptions, and safety notices in this document are based on Elster Solutions, LLC experience and judgment
with respect to operation and maintenance of the described product. This information should not be considered as all-inclusive or covering all
contingencies. If further information is required, Elster Solutions, LLC should be consulted.
No warranties, either expressed or implied, including warranties of fitness for a particular purpose or merchantability, or warranties arising from the
course of dealing or usage of trade, are made regarding the information, recommendations, descriptions, warnings, and cautions contained herein.
In no event will Elster Solutions, LLC be responsible to the user in contract, in tort (including negligence), strict liability or otherwise for any special,
indirect, incidental, or consequential damage or loss whatsoever, including but not limited to: damage or loss of use of equipment, cost of capital,
loss of profits or revenues, or claims against the user by its customers resulting from the use of the information, recommendations, descriptions, and            Elster Solutions
safety notices contained herein.                                                                                                                                  Raleigh, North Carolina
                                                                                                                                                                  Technical support: 800 338 5251
© 2016 by Elster. All rights reserved. Produced in the United States.



Document Created: 2019-11-11 10:35:48