Test Report

FCC ID: QYLK120R

Test Report

Download: PDF
FCCID_4054743

                                                              FCC Test Report

                      Report No.: RF180227C27B

                            FCC ID: QYLK120R

                      Test Model: K120

                 Received Date: Sep. 11, 2018

                         Test Date: Sep. 16, 2018 ~ Sep. 17, 2018

                     Issued Date: Sep. 21, 2018


                        Applicant: Getac Technology Corporation.

                          Address: 5F., Building A, No. 209, Sec.1, Nangang Rd.,Nangang Dist., Taipei City
                                   11568, Taiwan, R.O.C.



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                   Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                ( R.O.C )
                  Test Location: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan
                                 Hsien 333, Taiwan, R.O.C.
           FCC Registration /
                                            788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, pr ovided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.



Report No.: RF180227C27B                                             Page No. 1 / 33                                            Report Format Version: 6.1.1
Reference No.: 180911C14


                                                            Table of Contents
Release Control Record ........................................................................................................................ 3
1 Certificate of Conformity .................................................................................................................. 4
2 Summary of Test Results ................................................................................................................. 5
    2.1 Measurement Uncertainty ............................................................................................................ 5
    2.2 Modification Record..................................................................................................................... 5
3 General Information ......................................................................................................................... 6
    3.1 General Description of EUT ......................................................................................................... 6
    3.2 Description of Test Modes ............................................................................................................ 7
        3.2.1 Test Mode Applicability and Tested Channel Detail ............................................................... 7
    3.3 Description of Support Units......................................................................................................... 8
        3.3.1 Configuration of System under Test..................................................................................... 8
    3.4 General Description of Applied Standards ..................................................................................... 9
4 Test Types and Results .................................................................................................................. 10
    4.1 Radiated Emission Measurement ............................................................................................... 10
        4.1.1 Limits of Radiated Emission Measurement ........................................................................ 10
        4.1.2 Test Instruments .............................................................................................................. 11
        4.1.3 Test Procedures............................................................................................................... 13
        4.1.4 Deviation from Test Standard............................................................................................ 13
        4.1.5 Test Set Up ..................................................................................................................... 14
        4.1.6 EUT Operating Conditions ................................................................................................ 14
        4.1.7 Test Results .................................................................................................................... 15
    4.2 Conducted Emission Measurement ............................................................................................ 24
        4.2.1 Limits of Conducted Emission Measurement ..................................................................... 24
        4.2.2 Test Instruments .............................................................................................................. 24
        4.2.3 Test Procedures............................................................................................................... 25
        4.2.4 Deviation from Test Standard............................................................................................ 25
        4.2.5 Test Setup ....................................................................................................................... 25
        4.2.6 EUT Operating Conditions ................................................................................................ 25
        4.2.7 Test Results .................................................................................................................... 26
    4.3 Frequency Stability.................................................................................................................... 28
        4.3.1 Limits of Frequency Stability Measurement........................................................................ 28
        4.3.2 Test Setup ....................................................................................................................... 28
        4.3.3 Test Instruments .............................................................................................................. 28
        4.3.4 Test Procedure ................................................................................................................ 28
        4.3.5 Deviation from Test Standard............................................................................................ 28
        4.3.6 EUT Operating Conditions ................................................................................................ 28
        4.3.7 Test Results .................................................................................................................... 29
    4.4 20 dB Bandwidth ....................................................................................................................... 30
        4.4.1 Limits of 20 dB Bandwidth Measurement ........................................................................... 30
        4.4.2 Test Setup ....................................................................................................................... 30
        4.4.3 Test Instruments .............................................................................................................. 30
        4.4.4 Test Procedures............................................................................................................... 30
        4.4.5 Deviation from Test Standard............................................................................................ 30
        4.4.6 EUT Operating Conditions ................................................................................................ 30
        4.4.7 Test Results .................................................................................................................... 31
5 Pictures of Test Arrangements ....................................................................................................... 32
Appendix – Information on the Testing Laboratories .......................................................................... 33




Report No.: RF180227C27B                                      Page No. 2 / 33                                      Report Format Version: 6.1.1
Reference No.: 180911C14


                                              Release Control Record


 Issue No.                 Description                                         Date Issued
 RF180227C27B              Original Release                                    Sep. 21, 2018




Report No.: RF180227C27B                         Page No. 3 / 33       Report Format Version: 6.1.1
Reference No.: 180911C14


1    Certificate of Conformity


            Product: Tablet

              Brand: Getac

        Test Model: K120

    Sample Status: Identical Prototype

          Applicant: Getac Technology Corporation.

          Test Date: Sep. 16, 2018 ~ Sep. 17, 2018

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.225)
                           47 CFR FCC Part 15, Subpart C (Section 15.215)
                           ANSI C63.10:2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                                ,   Date:      Sep. 21, 2018
                                   Rona Chen / Specialist




     Approved by :                                                 ,   Date:      Sep. 21, 2018
                               Dylan Chiou / Project Engineer




Report No.: RF180227C27B                         Page No. 4 / 33                      Report Format Version: 6.1.1
Reference No.: 180911C14


2     Summary of Test Results

                            47 CFR FCC Part 15, Subpart C (Section 15.225, 15.215)
    FCC Clause                   Test Item                    Result                    Remarks
                                                                         Meet the requirement of limit.
      15.207               Conducted emission test                Pass   Minimum passing margin is -11.35 dB
                                                                         at 13.56130 MHz.
                                                                         Meet the requirement of limit.
                   The field strength of any emissions
    15.225 (a)                                                    Pass   Minimum passing margin is -68.02 dB
                   within the band 13.553-13.567 MHz
                                                                         at 13.56 MHz.
                   The field strength of any emissions
    15.225 (b)    within the bands 13.410-13.553 MHz              Pass   Meet the requirement of limit.
                         and 13.567-13.710 MHz
                    The field strength of any emissions
    15.225 (c)     within the bands 13.110-13.410 MHz             Pass   Meet the requirement of limit.
                          and 13.710-14.010 MHz
                   The field strength of any emissions                   Meet the requirement of limit.
    15.225 (d)          appearing outside of the                  Pass   Minimum passing margin is -4.44 dB at
                       13.110-14.010 MHz band                            170.65 MHz.
    15.225 (e)             The frequency tolerance                Pass   Meet the requirement of limit.
    15.215 (c)                20 dB Bandwidth                     Pass   Meet the requirement of limit.
      15.203                Antenna Requirement                   Pass   No antenna connector is used.


2.1    Measurement Uncertainty

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16-4-2:


                                                                                        Expended Uncertainty
                   Measurement                                     Frequency
                                                                                              (k=2) (±)

        Conducted Emissions at mains ports                   150 kHz ~ 30 MHz                    2.44 dB
                                                             30 MHz ~ 200 MHz                    2.93 dB
          Radiated Emissions up to 1 GHz
                                                           200 MHz ~ 1000 MHz                    2.95 dB


2.2    Modification Record
There were no modifications required for compliance.




Report No.: RF180227C27B                        Page No. 5 / 33                           Report Format Version: 6.1.1
Reference No.: 180911C14


3      General Information
3.1     General Description of EUT

 Product                          Tablet
 Brand                            Getac
 Test Model                       K120
 Status of EUT                    Identical Prototype
                                  11.1 Vdc (Battery)
 Power Supply Rating
                                  19 Vdc (Adapter)
 Modulation Type                  ASK
 Operating Frequency              13.56 MHz
 Antenna Type                     Loop Antenna
 Accessory Device                 Refer to Note
 Data Cable Supplied              Refer to Note
Note:
1. The EUT contains following accessory devices.
       Product                   Brand                        Model                          Description
                                                                               I/P: 100-240 Vac, 50-60 Hz, 1.7 A
        Adapter                 Chicony                   A12-065N2A           O/P: 19 Vdc, 3.42 A
                                                                               1.75 m shielded cable with 1 core
       Battery 1                 Getac                 BP3S1P2100S-01          11.1 Vdc, 2100 mAh
       Battery 2                 Getac                 BP4S1P3450P-01          14.4 Vdc, 3450 mAh
 WWAN Module                     Sierra                     EM7455             --
WiFi & BT Module                  Intel                    8265NGW              --
      RFID Module                Getac                K120 PN7462 NFC           --
* According to the pretest result, the Battery 1 had worse value. Therefore, Battery 1 was used for the final test.
2. The above EUT information is declared by manufacturer and for more detailed features description,
   please refers to the manufacturer's specifications or user's manual.




Report No.: RF180227C27B                             Page No. 6 / 33                               Report Format Version: 6.1.1
Reference No.: 180911C14


3.2     Description of Test Modes

One channel was provided to this EUT:
        Channel                Frequency (MHz)
              1                       13.56


3.2.1       Test Mode Applicability and Tested Channel Detail

 EUT Configure                                      Applicable To
                                                                                                             Description
      Mode                RE                  PLC                   FS                EB

        -                  √                   √                    √                   √           -

Where             RE: Radiat ed Emission                                   PLC: Power Line Conducted Emission
                  FS: Frequency Stability                                  EB: 20 dB Bandwidth measurement
NOTE: The E UT had been pre-tested on the positioned of eac h 3 axis and NB mode. The worst case was found when positioned on NB
mode.



Radiated Emission Test:
   Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
   available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
   Following channel(s) was (were) selected for the final test as listed below.
 EUT Configure
                        Available Channel              Tested Channel             Modulation Type                  Axis
      Mode

        -                       1                             1                         ASK                      NB mode



Power Line Conducted Emission Test:
   Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
  available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
   Following channel(s) was (were) selected for the final test as listed below.
 EUT Configure
                        Available Channel              Tested Channel             Modulation Type                  Axis
      Mode

        -                       1                             1                         ASK                      NB mode



Frequency Stability:
   This item includes all test value of each mode, but only includes spectrum plot of worst value of each
   mode.
   Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
   available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
   Following channel(s) was (were) selected for the final test as listed below.
 EUT Configure
                        Available Channel              Tested Channel             Modulation Type                  Axis
      Mode

        -                       1                             1                         ASK                      NB mode




Report No.: RF180227C27B                                 Page No. 7 / 33                                Report Format Version: 6.1.1
Reference No.: 180911C14


20 dB Bandwidth:
      This item includes all test value of each mode, but only includes spectrum plot of worst value of each
      mode.
      Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
      available modulations, data rates and antenna ports (if EUT with antenna diversity architecture).
      Following channel(s) was (were) selected for the final test as listed below.
EUT Configure
                            Available Channel               Tested Channel              Modulation Type              Axis
       Mode

         -                         1                              1                             ASK                NB mode



Test Condition:

   Applicable To                 Environmental Conditions                       Input Power                   Tested By

             RE                        25 deg. C, 65 % RH                      120 Vac, 60 Hz               Jisyong Wang

             FS                        25 deg. C, 65 % RH                         11.1 Vdc                  Jisyong Wang

         PLC                           25 deg. C, 65 % RH                      120 Vac, 60 Hz                 Anson Lin

             EB                        25 deg. C, 68 % RH                         11.1 Vdc                  Jisyong Wang




3.3     Description of Support Units
The following support units or accessories were used to form a representative test configuration during the
tests.
 No.              Product                   Brand              Model No.                     Serial No.             FCC ID
  1.              Easy Card                  N/A                  N/A                           N/A                   N/A

 No.                                       Signal Cable Description Of The Above Support Units
  1.    N/A
Note:
1. All power cords of the above support units are non-shielded (1.8m).
2. Items 1 acted as communication partners to transfer data.


3.3.1        Configuration of System under Test




                                                                  EUT          (Power from AC adapt er)
                                             Easy Card
                                                                               EUT



              *Test Table




Report No.: RF180227C27B                                     Page No. 8 / 33                              Report Format Version: 6.1.1
Reference No.: 180911C14


3.4   General Description of Applied Standards
The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:

FCC Part 15, Subpart C (15.225)
FCC Part 15, Subpart C (15.215)
ANSI C63.10-2013

All test items have been performed and recorded as per the above standards.




Report No.: RF180227C27B                    Page No. 9 / 33                    Report Format Version: 6.1.1
Reference No.: 180911C14


4       Test Types and Results
4.1     Radiated Emission Measurement
4.1.1    Limits of Radiated Emission Measurement
a. The field strength of any emissions within the band 13.553-13.567 MHz shall not exceed 15,848
   microvolts/meter at 30 meters.
b. Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of any emissions shall
   not exceed 334 microvolts/meter at 30 meters.
c. Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz the field strength of any emissions shall not
   exceed 106 microvolts/meter at 30 meters.
d. The field strength of any emissions appearing outside of the 13.110-14.010 MHz band shall not exceed
   the general radiated emission limits in §15.209 as below table:


            Frequencies                      Field Strength                Measurement Distance
               (MHz)                       (microvolts/meter)                    (meters)
            0.009 ~ 0.490                     2400/F (kHz)                           300
            0.490 ~ 1.705                    24000/F (kHz)                            30
            1.705 ~ 30.0                            30                                30
               30 ~ 88                             100                                 3
              88 ~ 216                             150                                 3
             216 ~ 960                             200                                 3
             Above 960                             500                                 3
NOTE:
1. The lower limit shall apply at the transition frequencies.
2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
3. For frequencies above 1000 MHz, the field strength limits are based on average detector, however, the
   peak field strength of any emission shall not exceed the maximum permitted average limits, specified
   above by more than 20 dB under any condition of modulation.




Report No.: RF180227C27B                    Page No. 10 / 33                      Report Format Version: 6.1.1
Reference No.: 180911C14


4.1.2    Test Instruments

        Description &                                            Date of               Due Date of
                             Model No.            Serial No.
        Manufacturer                                            Calibration            Calibration
Test Receiver
                              N9038A            MY51210203     Mar. 16, 2018          Mar. 15, 2019
Agilent
Spectrum Analyzer
                              N9010A            MY52220314     Nov. 24, 2017          Nov. 23, 2018
Agilent
Spectrum Analyzer
                              FSU43                 101261     Jan. 11, 2018          Jan. 10, 2019
ROHDE & SCHWARZ
BILOG Antenna
                            VULB 9168             9168-472     Dec. 06, 2017          Dec. 05, 2018
SCHWARZBECK
Fixed Attenuator
                            MDCS18N-10        MDCS18N-10-01    Apr. 18, 2018          Apr. 17, 2019
Mini-Circuits

Loop Antenna                 EM-6879                  269      Sep. 07, 2018          Sep. 06, 2019

Preamplifier
                            EMC001340               980201     Nov. 01, 2017          Oct. 30, 2018
EMCI
Preamplifier
                             EMC 330H               980112     Oct. 13, 2017          Oct. 12, 2018
EMCI
Power Meter
                             ML2495A               1012010     Sep. 05, 2018          Sep. 04, 2019
Anritsu
Power Sensor
                             MA2411B               1315050     Sep. 04, 2018          Sep. 03, 2019
Anritsu
RF Coaxial Cable
                              8D-FB            Cable-Ch10-01   Oct. 20, 2017          Oct. 19, 2018
Worken
Software                        E3
                                                      NA            NA                      NA
BV ADT                       6.120103
Antenna Tower
                             MFA-440H                 NA            NA                      NA
MF
Turn Table
                            MFT-201SS                 NA            NA                      NA
MF
Antenna Tower &Turn
Table Controller             MF-7802                  NA            NA                      NA
MF
Temperature & Humidity
                            HRM-120RF               931022     Nov. 20, 2017          Nov. 19, 2018
Chamber
DC Power Supply
                              33010D                807748     Oct. 25, 2016          Oct. 24, 2018
Topward
Digital Multimeter
                               87-III             70360742     Jun. 29, 2018          Jun. 28, 2019
Fluke




Report No.: RF180227C27B                 Page No. 11 / 33                      Report Format Version: 6.1.1
Reference No.: 180911C14


Note: 1. The calibration interval of the above test instruments is 12 / 24 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Chamber 10.
      3. The horn antenna and preamplifier (model: EMC 184045) are used only for the measurement of
         emission frequency above 1 GHz if tested.
      4. The IC Site Registration No. is IC7450F-10.




Report No.: RF180227C27B                      Page No. 12 / 33                        Report Format Version: 6.1.1
Reference No.: 180911C14


4.1.3   Test Procedures
For Radiated Emission below 30 MHz
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
   room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
   of a variable-height antenna tower.
c. Both Parallel, perpendicular, and ground-parallel orientations of the antenna are set to make the
   measurement.
d. For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
   from 0 degrees to 360 degrees to find the maximum reading.
e. The test-receiver system was set to Quasi-Peak Detect Function and Specified Bandwidth with Maximum
   Hold Mode.
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9 kHz at frequency
   below 30 MHz.

For Radiated Emission above 30 MHz
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at 3 meter chamber room
   for test. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
   of a variable-height antenna tower.
c. The height of antenna is varied from one meter to four meters above the ground to determine the
   maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
   make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
   heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find
   the maximum reading.
e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
   hold mode when the test frequency is below 1 GHz.
f. The test-receiver system was set to peak and average detected function and specified bandwidth with
   maximum hold mode when the test frequency is above 1 GHz. If the peak reading value also meets
   average limit, measurement with the average detector is unnecessary.
Note:
1. The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 kHz for
   Quasi-peak detection (QP) at frequency below 1 GHz.
2. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is 3 MHz
   for Peak detection (PK) at frequency above 1 GHz.
3. The resolution bandwidth of test receiver/spectrum analyzer is 1 MHz and the video bandwidth is ≥ 1/T
   (Duty cycle < 98 %) or 10 Hz (Duty cycle ≥ 98 %) for Average detection (AV) at frequency above 1 GHz.
4. All modes of operation were investigated and the worst-case emissions are reported.


4.1.4   Deviation from Test Standard
No deviation.




Report No.: RF180227C27B                     Page No. 13 / 33                        Report Format Version: 6.1.1
Reference No.: 180911C14


4.1.5   Test Set Up
  <Radiated Emission below 30 MHz>


                                                                                   1m
           EUT&                                3m
           Support Units

                                    Turn Table

              80 cm


                                            Ground Plane
                                            Test Receiver




  <Radiated Emission 30 MHz to 1 GHz>

                                                               Ant. Tower
                                                                                      1-4m
                                                                                      Variable
              EUT&
                                               3m
                                                10m
              Support Units

                                         Turn Table

                 80cm


                                              Ground Plane

                                              Test Receiver




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.1.6   EUT Operating Conditions

a. Placed the EUT on the testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF180227C27B                        Page No. 14 / 33                           Report Format Version: 6.1.1
Reference No.: 180911C14


4.1.7   Test Results
No non-compliance noted:

KDB 937606 OATS and Chamber Correlation Justification

- Base on FCC 15.31 (f) (2): measurements may be performed at a distance closer than that specified in the
regulations; however, an attempt should be made to avoid making measurements in the near field.

- OATs and chamber correlation testing had been performed and chamber measured test result is the worst
case test result.




Report No.: RF180227C27B                     Page No. 15 / 33                       Report Format Version: 6.1.1
Reference No.: 180911C14


EUT Test Condition                                               Measurement Detail
Channel                            Channel 1                     Frequency Range                  13.553 ~ 13.567 MHz

Input Power                        120 Vac, 60 Hz                Detector Function                Quasi-Peak
Environmental
                                   25 deg. C, 65 % RH            Tested By                        Jisyong Wang
Conditions




                        Antenna Polarity & Test Distance: Loop Antenna Open at 3 m
            Emi ssion      Read                              Antenna                             Antenna    Table
Frequency                              Limit     Margin                   Cable Loss Preamp
              Level        Level                              Factor                             Height     Angle      Remark
   (MHz)                              (dBuV/m)      (dB)                    (dB)   Factor (dB)
            (dBuV/m)       (dBuV )                            (dB/m)                              (cm)     (Degree)

   13.56      55.98        59.36        124      -68.02       37.67         0.31     41.36         100       360         QP

Remarks:
1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m)
2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value.
5. Above limits have been translated by the formula

The measured field strength was extrapolated to distance 30 meters, using the formula that the limit of field
strength varies as the inverse distance square (40dB per decade of distance)
Example:
13.56 MHz = 15848 uV/m                   30m
            = 84 dBuV/m                  30m
                               2
            = 84+20log(30/3)             3m
            = 124 dBuV/m




Report No.: RF180227C27B                               Page No. 16 / 33                              Report Format Version: 6.1.1
Reference No.: 180911C14


EUT Test Condition                                               Measurement Detail
Channel                            Channel 1                     Frequency Range                  13.553 ~ 13.567 MHz

Input Power                        120 Vac, 60 Hz                Detector Function                Quasi-Peak
Environmental
                                   25 deg. C, 65 % RH            Tested By                        Jisyong Wang
Conditions




                        Antenna Polarity & Test Distance: Loop Antenna Close at 3 m
            Emi ssion      Read                              Antenna                             Antenna    Table
Frequency                              Limit     Margin                   Cable Loss Preamp
              Level        Level                              Factor                             Height     Angle      Remark
   (MHz)                              (dBuV/m)      (dB)                    (dB)   Factor (dB)
            (dBuV/m)       (dBuV )                            (dB/m)                              (cm)     (Degree)

   13.56      50.52         53.9        124      -73.48       37.67         0.31     41.36         100        0          QP
Remarks:
1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m)
2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value.
5. Above limits have been translated by the formula

The measured field strength was extrapolated to distance 30 meters, using the formula that the limit of field
strength varies as the inverse distance square (40dB per decade of distance)
Example:
13.56 MHz = 15848 uV/m                   30m
            = 84 dBuV/m                  30m
            = 84+20log(30/3) 2           3m
            = 124 dBuV/m




Report No.: RF180227C27B                               Page No. 17 / 33                              Report Format Version: 6.1.1
Reference No.: 180911C14


EUT Test Condition                                               Measurement Detail
Channel                            Channel 1                     Frequency Range                  13.553 ~ 13.567 MHz

Input Power                        120 Vac, 60 Hz                Detector Function                Quasi-Peak
Environmental
                                   25 deg. C, 65 % RH            Tested By                        Jisyong Wang
Conditions




                 Antenna Polarity & Test Distance: Loop Antenna Ground-parallel at 3 m
            Emi ssion      Read                              Antenna                             Antenna    Table
Frequency                              Limit     Margin                   Cable Loss Preamp
              Level        Level                              Factor                             Height     Angle      Remark
   (MHz)                              (dBuV/m)      (dB)                    (dB)   Factor (dB)
            (dBuV/m)       (dBuV )                            (dB/m)                              (cm)     (Degree)

   13.56      50.98        54.36        124      -73.02       37.67         0.31     41.36         100       360         QP

Remarks:
1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m)
2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value.
5. Above limits have been translated by the formula

The measured field strength was extrapolated to distance 30 meters, using the formula that the limit of field
strength varies as the inverse distance square (40dB per decade of distance)
Example:
13.56 MHz = 15848 uV/m                   30m
            = 84 dBuV/m                  30m
            = 84+20log(30/3) 2           3m
            = 124 dBuV/m




Report No.: RF180227C27B                               Page No. 18 / 33                              Report Format Version: 6.1.1
Reference No.: 180911C14


EUT Test Condition                                            Measurement Detail
Channel                         Channel 1                     Frequency Range                 Below 30 MHz

Input Power                     120 Vac, 60 Hz                Detector Function               Quasi-Peak
Environmental
                                25 deg. C, 65 % RH            Tested By                       Jisyong Wang
Conditions




                        Antenna Polarity & Test Distance: Loop Antenna Open at 3 m
            Emi ssion      Read                           Antenna                             Antenna    Table
Frequency                             Limit     Margin                 Cable Loss Preamp
              Level        Level                           Factor                             Height     Angle      Remark
   (MHz)                             (dBuV/m)    (dB)                    (dB)   Factor (dB)
            (dBuV/m)       (dBuV )                         (dB/m)                              (cm)     (Degree)

   27.12      25.62        31.02      69.54     -43.92     35.55         0.38     41.33         100        0          QP
Remarks:
1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m)
2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value.




Report No.: RF180227C27B                            Page No. 19 / 33                              Report Format Version: 6.1.1
Reference No.: 180911C14


EUT Test Condition                                               Measurement Detail
Channel                            Channel 1                     Frequency Range                  Below 30 MHz

Input Power                        120 Vac, 60 Hz                Detector Function                Quasi-Peak
Environmental
                                   25 deg. C, 65 % RH            Tested By                        Jisyong Wang
Conditions




                        Antenna Polarity & Test Distance: Loop Antenna Close at 3 m
            Emi ssion      Read                              Antenna                             Antenna    Table
Frequency                              Limit     Margin                   Cable Loss Preamp
              Level        Level                              Factor                             Height     Angle      Remark
   (MHz)                              (dBuV/m)      (dB)                    (dB)   Factor (dB)
            (dBuV/m)       (dBuV )                            (dB/m)                              (cm)     (Degree)

   27.12      38.99        44.39       69.54     -30.55       35.55         0.38     41.33         100       360         QP
Remarks:
1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m)
2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value.




Report No.: RF180227C27B                               Page No. 20 / 33                              Report Format Version: 6.1.1
Reference No.: 180911C14


EUT Test Condition                                               Measurement Detail
Channel                            Channel 1                     Frequency Range                  Below 30 MHz

Input Power                        120 Vac, 60 Hz                Detector Function                Quasi-Peak
Environmental
                                   25 deg. C, 65 % RH            Tested By                        Jisyong Wang
Conditions




                 Antenna Polarity & Test Distance: Loop Antenna Ground-parallel at 3 m
            Emi ssion      Read                              Antenna                             Antenna    Table
Frequency                              Limit     Margin                   Cable Loss Preamp
              Level        Level                              Factor                             Height     Angle      Remark
   (MHz)                              (dBuV/m)      (dB)                    (dB)   Factor (dB)
            (dBuV/m)       (dBuV )                            (dB/m)                              (cm)     (Degree)

   27.12      39.98        45.38       69.54     -29.56       35.55         0.38     41.33         100        0          QP
Remarks:
1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m)
2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value.




Report No.: RF180227C27B                               Page No. 21 / 33                              Report Format Version: 6.1.1
Reference No.: 180911C14


 EUT Test Condition                                    Measurement Detail
 Channel                   Channel 1                   Frequency Range      Below 1000 MHz

 Input Power               120 Vac, 60 Hz              Detector Function    Quasi-Peak
 Environmental
                           25 deg. C, 65 % RH          Tested By            Jisyong Wang
 Conditions

Horizontal




Vertical




Report No.: RF180227C27B                    Page No. 22 / 33                  Report Format Version: 6.1.1
Reference No.: 180911C14


                               Antenna Polarity & Test Distance: Horizontal at 3 m
            Emi ssion      Read                            Antenna      Cable                 Antenna    Table
Frequency                               Limit    Margin                          Preamp
              Level        Level                             Factor     Loss                  Height     Angle     Remark
  (MHz)                               (dBuV/m)    (dB)                          Factor (dB)
            (dBuV/m)       (dBuV )                          (dB/m)      (dB)                   (cm)     (Degree)

  170.65      39.06        58.06        43.5      -4.44      11.67      1.07      31.74         185       265        Peak
   253.1      38.44         57.3         46       -7.56      11.57      1.48      31.91         132       251        Peak
  600.36      26.19        35.93         46      -19.81      19.61       2.9      32.25         111       174        Peak
  722.58      26.55        33.65         46      -19.45      21.13      3.41      31.64         165       295        Peak
  792.42      28.57        34.22         46      -17.43      22.12      3.64      31.41         174       185        Peak
  937.92      30.15        34.19         46      -15.85      23.72      4.18      31.94         102       231        Peak
                                   Antenna Polarity & Test Distance: Vertical at 3 m
            Emi ssion      Read                            Antenna      Cable                 Antenna    Table
Frequency                               Limit    Margin                          Preamp
              Level        Level                             Factor     Loss                  Height     Angle     Remark
  (MHz)                               (dBuV/m)    (dB)                          Factor (dB)
            (dBuV/m)       (dBuV )                          (dB/m)      (dB)                   (cm)     (Degree)

   43.58      31.41        48.43         40       -8.59      13.59       0.5      31.11         165       285        Peak
   69.77      28.04        48.45         40      -11.96      10.77      0.64      31.82         111       195        Peak
  177.44      36.15        55.84        43.5      -7.35      11.01      1.11      31.81         102       231        Peak
  257.95       31.3        49.97         46       -14.7      11.71      1.49      31.87         111       165        Peak
  754.59      28.65         34.9         46      -17.35      21.59      3.53      31.37         185       295        Peak
  908.82       32.4        36.81         46       -13.6      23.56      4.08      32.05         111       152        Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
2. Margin value = Emission level – Limit value.
3. The other emission levels were very low against the limit.
4. Correction Factor(dB/m) = Antenna Factor(dB/m) + Cable Factor(dB)
                                   – Pre-Amplifier Factor (dB)




Report No.: RF180227C27B                             Page No. 23 / 33                             Report Format Version: 6.1.1
Reference No.: 180911C14


4.2     Conducted Emission Measurement
4.2.1     Limits of Conducted Emission Measurement

                                                           Conducted Limit (dBuV)
        Frequency (MHz)
                                            Quasi-Peak                                  Average
            0.15 - 0.5                         66 - 56                                   56 - 46
            0.50 - 5.0                            56                                       46
            5.0 - 30.0                            60                                       50
Note:
1. The lower limit shall apply at the transition frequencies.
2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.
3. All emanations from a class A/B digital device or system, including any network of conductors and
   apparatus connected thereto, shall not exceed the level of field strengths specified above.


4.2.2     Test Instruments

        Description &                                                      Date of               Due Date of
                               Model No.               Serial No.
        Manufacturer                                                      Calibration            Calibration
Test Receiver
                                  ESCI                   100613          Nov. 23, 2017          Nov. 22, 2018
ROHDE & SCHWARZ
RF signal cable
                                 5D-FB             Cable-cond1-01        Sep. 05, 2018          Sep. 04, 2019
Woken
LISN/AMN
ROHDE & SCHWARZ                 ENV216                   101826          Feb. 26, 2018          Feb. 25, 2019
(EUT)
LISN/AMN
ROHDE & SCHWARZ                 ESH3-Z5                  100311          Aug. 19, 2018          Aug. 18, 2019
(Peripheral)
Software                     BV ADT_Cond_
                                                           NA                  NA                     NA
ADT                             V7.3.7.4

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Shielded Room 1.
      3. The VCCI Site Registration No. is C-2040.




Report No.: RF180227C27B                       Page No. 24 / 33                          Report Format Version: 6.1.1
Reference No.: 180911C14


4.2.3   Test Procedures
a.   The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
     connected to the power mains through a line impedance stabilization network (LISN). Other support units
     were connected to the power mains through another LISN. The two LISNs provide 50 ohm/50 uH of
     coupling impedance for the measuring instrument.
b.   Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c.   The frequency range from 150 kHz to 30 MHz was searched. Emission levels under (Limit – 20 dB) was
     not recorded.

Note: The resolution bandwidth and video bandwidth of test receiver is 9 kHz for quasi-peak detection (QP)
and average detection (AV) at frequency 0.15 MHz - 30 MHz.


4.2.4   Deviation from Test Standard

No deviation.


4.2.5   Test Setup

                                  Vertical Ground
                                  Reference Plane                                Test Receiver


                                  EUT
                     40cm




                                                        80cm
                     LISN



                                                                   Horizontal Ground
                                                                    Reference Plane

                      Note: 1.Support units were connected to second LISN.
                              2.Both of LISNs (AMN) are 80 cm from EUT and at least 80
                       cm       from other units and other metal planes
                           support.   units.
For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.2.6   EUT Operating Conditions

a. Placed the EUT on the testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF180227C27B                        Page No. 25 / 33                           Report Format Version: 6.1.1
Reference No.: 180911C14


4.2.7   Test Results
                                                         Detector Function &
                                                                               Quasi-Peak (QP) /
Frequency Range            150kHz ~ 30MHz                Resolution
                                                                               Average (AV), 9kHz
                                                         Bandwidth
                                                         Environmental
Input Power                120Vac, 60Hz                                        25℃, 65%RH
                                                         Conditions
Tested by                  Jisyong Wang                  Test Date             2018/9/17

                                           Phase Of Power : Line (L)
        Frequency      Correction   Reading Value     Emission Level            Limit              Margin
 No                     Factor          (dBuV)            (dBuV)              (dBuV)                 (dB)
           (MHz)         (dB)        Q.P.     AV.      Q.P.      AV.       Q.P.       AV.       Q.P.      AV.
  1       0.16564        9.67       43.03    29.14    52.70    38.81      65.18     55.18      -12.48 -16.37
  2       0.17744        9.67       30.82    11.99    40.49    21.66      64.60     54.60      -24.11 -32.94
  3       0.22024        9.67       32.85    18.45    42.52    28.12      62.81     52.81      -20.29 -24.69
  4       0.31813        9.66       18.84     4.85    28.50    14.51      59.76     49.76      -31.26 -35.25
  5       0.48626        9.66       25.13     8.88    34.79    18.54      56.23     46.23      -21.44 -27.69
  6      13.56130        9.87       35.25    10.00    45.12    19.87      60.00     50.00      -14.88 -30.13
Remarks:
       1.   Q.P. and AV. are abbreviations of quasi-peak and average individually.
       2.   The emission levels of other frequencies were very low against the limit.
       3.   Margin value = Emission level – Limit value
       4.   Correction factor = Insertion loss + Cable loss
       5.   Emission Level = Correction Factor + Reading Value




Report No.: RF180227C27B                       Page No. 26 / 33                         Report Format Version: 6.1.1
Reference No.: 180911C14


                                                         Detector Function &
                                                                               Quasi-Peak (QP) /
Frequency Range            150kHz ~ 30MHz                Resolution
                                                                               Average (AV), 9kHz
                                                         Bandwidth
                                                         Environmental
Input Power                120Vac, 60Hz                                        25℃, 65%RH
                                                         Conditions
Tested by                  Jisyong Wang                  Test Date             2018/9/17

                                          Phase Of Power : Neutral (N)
        Frequency     Correction    Reading Value     Emission Level            Limit              Margin
 No                    Factor           (dBuV)            (dBuV)              (dBuV)                 (dB)
           (MHz)        (dB)         Q.P.     AV.      Q.P.      AV.       Q.P.       AV.       Q.P.      AV.
  1       0.17744       9.67        39.86    18.15    49.53     27.82     64.60     54.60      -15.07 -26.78
  2       0.18903       9.67        35.16    20.28    44.83     29.95     64.08     54.08      -19.25 -24.13
  3       0.24775       9.67        27.80    10.51    37.47     20.18     61.83     51.83      -24.36 -31.65
  4       0.31021       9.67        23.72     7.06    33.39     16.73     59.96     49.96      -26.57 -33.23
  5       0.54882       9.67        23.75     7.85    33.42     17.52     56.00     46.00      -22.58 -28.48
  6      13.56130       9.92        38.73    18.82    48.65     28.74     60.00     50.00      -11.35 -21.26
Remarks:
       1.   Q.P. and AV. are abbreviations of quasi-peak and average individually.
       2.   The emission levels of other frequencies were very low against the limit.
       3.   Margin value = Emission level – Limit value
       4.   Correction factor = Insertion loss + Cable loss
       5.   Emission Level = Correction Factor + Reading Value




Report No.: RF180227C27B                       Page No. 27 / 33                         Report Format Version: 6.1.1
Reference No.: 180911C14


4.3      Frequency Stability
4.3.1      Limits of Frequency Stability Measurement

The frequency tolerance of the carrier signal shall be maintained within +/ - 0.01 % of the operating frequency
over a temperature variation of –20 degrees to 50 degrees C at normal supply voltage, and for a variation in
the primary supply voltage from 85 % to 115 % of the rated supply voltage at a temperature of 20 degrees C.


4.3.2      Test Setup

                            Temperature
                            Chamber

      Spectrum Analyzer




                     DC Power Supply




4.3.3      Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.3.4      Test Procedure
a. The EUT was placed inside the environmental test chamber and powered by nominal DC voltage.
b. Turned the EUT on and coupled its output to a spectrum analyzer.
c. Turned the EUT off and set the chamber to the highest temperature specified.
d. Allowed sufficient time (approximately 30 min) for the temperature of the chamber to stabilize then turned
   the EUT on and measured the operating frequency after 2, 5, and 10 minutes.
e. Repeated step 2 and 3 with the temperature chamber set to the lowest temperature.
f. The test chamber was allowed to stabilize at +20 degree C for a minimum of 30 minutes. The supply
   voltage was then adjusted on the EUT from 85 % to 115 % and the frequency record.


4.3.5      Deviation from Test Standard

No deviation.


4.3.6      EUT Operating Conditions

a. Placed the EUT on the testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF180227C27B                       Page No. 28 / 33                        Report Format Version: 6.1.1
Reference No.: 180911C14


4.3.7   Test Results

                                      Frequency Stability Versus Temperature

                           0 Minute                2 Minute                5 Minute                 10 Minute
Temp. Power Measured Frequency Measured Frequency Measured Frequency Measured Frequency
      Supply
 (℃ )        Frequency  Drift  Frequency   Drift  Frequency   Drift  Frequency   Drift
       (Vdc)
               (MHz)     %       (MHz)      %       (MHz)      %       (MHz)      %

  50     11.1    13.56005       0.00037      13.56005     0.00037     13.56005   0.00037    13.56005       0.00037
  40     11.1    13.55997       -0.00022     13.55997    -0.00022     13.55997   -0.00022   13.55997       -0.00022
  30     11.1    13.56004       0.00029      13.56005     0.00037     13.56006   0.00044    13.56006       0.00044
  20     11.1    13.55996       -0.00029     13.55996    -0.00029     13.55996   -0.00029   13.55996       -0.00029
  10     11.1    13.55995       -0.00037     13.55995    -0.00037     13.55995   -0.00037   13.55995       -0.00037
   0     11.1    13.56005       0.00037      13.56005     0.00037     13.56004   0.00029    13.56005       0.00037
  -10    11.1    13.56004       0.00029      13.56004     0.00029     13.56005   0.00037    13.56003       0.00022
  -20    11.1    13.56004       0.00029      13.56004     0.00029     13.56005   0.00037    13.56005       0.00037


                                           Frequency Stability Versus Voltage

                           0 Minute                2 Minute                5 Minute                 10 Minute
Temp. Power Measured Frequency Measured Frequency Measured Frequency Measured Frequency
      Supply
 (℃ )        Frequency  Drift  Frequency   Drift  Frequency   Drift  Frequency   Drift
       (Vdc)
               (MHz)     %       (MHz)      %       (MHz)      %       (MHz)      %

        12.765 13.55996         -0.00029     13.55996    -0.00029     13.55996   -0.00029   13.55996       -0.00029
  20     11.1    13.55996       -0.00029     13.55996    -0.00029     13.55996   -0.00029   13.55996       -0.00029
        9.435    13.55996       -0.00029     13.55996    -0.00029     13.55996   -0.00029   13.55996       -0.00029




Report No.: RF180227C27B                           Page No. 29 / 33                         Report Format Version: 6.1.1
Reference No.: 180911C14


4.4     20 dB Bandwidth
4.4.1    Limits of 20 dB Bandwidth Measurement

The 20 dB bandwidth shall be specified in operating frequency band.


4.4.2    Test Setup
Refer to section 4.1.5.


4.4.3    Test Instruments

Refer to section 4.1.2 to get information of above instrument.


4.4.4    Test Procedures

The bandwidth of the fundamental frequency was measured by spectrum analyzer with 1 kHz RBW and 3 kHz
VBW. The 20 dB bandwidth is defined as the total spectrum the power of which is higher than peak power
minus 20 dB.


4.4.5    Deviation from Test Standard

No deviation.


4.4.6    EUT Operating Conditions

a. Placed the EUT on the testing table.
b. Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF180227C27B                       Page No. 30 / 33                    Report Format Version: 6.1.1
Reference No.: 180911C14


4.4.7   Test Results

                                                  Operating Frequency Band
   20 dBc Point (Low)      20 dBc Point (High)                                    Pass / Fail
                                                            (MHz)
   13.558910256 MHz        13.561474359 MHz                 13.553~13.567             Pass


                                      Spectrum Plot Of Value




Report No.: RF180227C27B                 Page No. 31 / 33                    Report Format Version: 6.1.1
Reference No.: 180911C14


5    Pictures of Test Arrangements
Please refer to the attached file (Test Setup Photo).




Report No.: RF180227C27B                       Page No. 32 / 33   Report Format Version: 6.1.1
Reference No.: 180911C14


Appendix – Information on the Testing Laboratories

We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab                                       Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                    Tel: 886-3-6668565
Fax: 886-2-26051924                                    Fax: 886-3-6668323

Hwa Ya EMC/RF/Safety
Tel: 886-3-3183232
Fax: 886-3-3270892

Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF180227C27B                       Page No. 33 / 33                  Report Format Version: 6.1.1
Reference No.: 180911C14



Document Created: 2018-10-11 14:51:27
Document Modified: 2018-10-11 14:51:27

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC