RF Test Report

FCC ID: QYLK120

Test Report

Download: PDF
FCCID_3899543

                                                               FCC Test Report

                       Report No.: RF180227C27-10

                            FCC ID: QYLK120

                       Test Model: TP-125S01-H1S1-GT

                 Received Date: Mar. 02, 2018

                         Test Date: May 24, 2018 ~ May 25, 2018

                     Issued Date: Jun. 06, 2018


                         Applicant: Getac Technology Corporation.

                          Address: 5F., Building A, No. 209, Sec.1, Nangang Rd.,Nangang Dist., Taipei City
                                   11568, Taiwan, R.O.C.



                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch

                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan
                                 ( R.O.C )
                  Test Location: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan
                                 Hsien 333, Taiwan, R.O.C.
            FCC Registration /
                                            788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.




Report No.: RF180227C27-10                                           Page No. 1 / 26                                            Report Format Version: 6.1.1


                                                                Table of Contents
Release Control Record .................................................................................................................................. 3
1 Certificate of Conformity ........................................................................................................................... 4
2 Summary of Test Results ........................................................................................................................... 5
    2.1 Measurement Uncertainty ..................................................................................................................... 5
    2.2 Modification Record .............................................................................................................................. 5
3 General Information ................................................................................................................................... 6
    3.1 General Description of EUT .................................................................................................................. 6
    3.2 Description of Support Units ................................................................................................................. 7
        3.2.1 Configuration of System under Test ........................................................................................... 7
    3.3 General Description of Applied Standards ............................................................................................ 7
4 Test Types and Results .............................................................................................................................. 8
    4.1 Radiated Emission and Bandedge Measurement ................................................................................ 8
        4.1.1 Limits of Radiated Emission and Bandedge Measurement ....................................................... 8
        4.1.2 Test Instruments ......................................................................................................................... 9
        4.1.3 Test Procedures ........................................................................................................................ 10
        4.1.4 Deviation from Test Standard ................................................................................................... 10
        4.1.5 Test Setup .................................................................................................................................. 11
        4.1.6 EUT Operating Conditions ......................................................................................................... 11
        4.1.7 Test Results .............................................................................................................................. 12
    4.2 Conducted Emission Measurement .................................................................................................... 18
        4.2.1 Limits of Conducted Emission Measurement ........................................................................... 18
        4.2.2 Test Instruments ....................................................................................................................... 18
        4.2.3 Test Procedures ........................................................................................................................ 19
        4.2.4 Deviation from Test Standard ................................................................................................... 20
        4.2.5 Test Setup ................................................................................................................................. 20
        4.2.6 EUT Operating Conditions ........................................................................................................ 20
        4.2.7 Test Results .............................................................................................................................. 21
5 Pictures of Test Arrangements................................................................................................................ 25
Appendix – Information on the Testing Laboratories ................................................................................ 26




Report No.: RF180227C27-10                                        Page No. 2 / 26                                           Report Format Version: 6.1.1


                                           Release Control Record


 Issue No.              Description                                       Date Issued
 RF180227C27-10         Original Release                                  Jun. 06, 2018




Report No.: RF180227C27-10                    Page No. 3 / 26       Report Format Version: 6.1.1


1    Certificate of Conformity


            Product: Digitizer module

              Brand: HANVON

        Test Model: TP-125S01-H1S1-GT

    Sample Status: Identical Prototype

          Applicant: Getac Technology Corporation.

          Test Date: May 24, 2018 ~ May 25, 2018

         Standards: 47 CFR FCC Part 15, Subpart C (Section 15.209)
                        ANSI C63.10: 2013



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




     Prepared by :                                               ,   Date:       Jun. 06, 2018
                                Evonne Liu / Specialist




     Approved by :                                               ,   Date:       Jun. 06, 2018
                             Dylan Chiou / Project Engineer




Report No.: RF180227C27-10                     Page No. 4 / 26                        Report Format Version: 6.1.1


2     Summary of Test Results

                             47 CFR FCC Part 15, Subpart C (Section 15.207, 15.209)

    FCC Clause                     Test Item                    Result                     Remarks
                                                                            Meet the requirement of limit.
      15.207             Conducted emission test                    Pass    Minimum passing margin is —17.81 dB
                                                                            at 0.47915 MHz.
                                                                            Meet the requirement of limit.
      15.209                 Radiated emission test                 Pass    Minimum passing margin is —13.55 dB
                                                                            at 160.95 MHz.


2.1    Measurement Uncertainty

Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT as specified in CISPR 16—4—2:


                                                                                           Expended Uncertainty
                    Measurement                                      Frequenc
                                                                           Aes                     (k=2) (©)
        Conducted Emissions at mains ports                     150 kHz ~ 30 MHz                     2.44 dB
                                                               30 MHz ~ 200 MHz                     2.93 dB
          Radiated Emissions up to 1 GHz
                                                             200 MHz ~ 1000 MHz                     2.95 dB



2.2    Modification Record
There were no modifications required for compliance.




Report No.: RF180227G27—10                        Page No. 5 / 26                            Report Format Version: 6.1.1


3     General Information
3.1    General Description of EUT

 Product                       Digitizer module
 Brand                         HANVON
 Test Model                    TP-125S01-H1S1-GT
 Status of EUT                 Identical Prototype
 Power Supply Rating           5 Vdc from host device
                               500 kHz
 Operating Frequency
                               400 kHz (Button on)
 Antenna Type                  Array Antenna
 Antenna Connector             N/A
 Accessory Device              Refer to Note as below
 Data Cable Supplied           Refer to Note as below
Note:
1. The EUT is authorized for use in specific End-product. Please refer to below for more details.
                Product                                Brand                             Model
                    Tablet                              Getac                            K120
2. The EUT contains following accessory devices.
      Product                Brand                        Model                     Description
                                                                      I/P: 100-240 Vac, 50-60 Hz, 1.7 A
      Adapter                Chicony                  A12-065N2A      O/P: 19 Vdc, 3.42 A
                                                                      1.75 m shielded cable with 1 core
    Battery 1                 Getac                BP3S1P2100S-01     11.1 Vdc, 2100 mAh
    Battery 2                 Getac                BP4S1P3450P-01     14.4 Vdc, 3450 mAh
 WWAN Module                  Sierra                   EM7455         --
WiFi & BT Module               Intel                  8265NGW         --
      * According to the pretest result, the Battery 1 had worse value. Therefore, Battery 1 was used for the
      final test.
3. This device has 2 configurations as below.
     Mode A: 500 kHz
      Mode B: 400 kHz (Button on)
4. The above EUT information is declared by manufacturer and for more detailed features description,
   please refers to the manufacturer's specifications or user's manual.




Report No.: RF180227C27-10                        Page No. 6 / 26                      Report Format Version: 6.1.1


3.2      Description of Support Units

The EUT has been tested as an independent unit together with other necessary accessories or support units.
The following support units or accessories were used to form a representative test configuration during the
tests.
  No.            Product                 Brand              Model No.                      Serial No.              FCC ID
  A.           Digitizer pen              N/A                   N/A                           N/A                    N/A


 No.                                      Signal Cable Description Of The Above Support Units
 1.     N/A
Note:
1.   All power cords of the above support units are non—shielded (1.8m).
2. The pen is just replaced the hand to touch tablet screen, not with other RF function.


3.2.1     Configuration of System under Test

                                                  Q_




                                                          $$S
                                                           NB
                                                        EUT
                                                 (Power from AC Adapter)



          *Test Table



3.3     General Description of Applied Standards

The EUT is a RF Product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:


FCC Part 15, Subpart C (15.209)
ANSI C63.10—2013


All test items have been performed and recorded as per the above standards.




Report No.: RF180227G27—10                               Page No. 7 / 26                                Report Format Version: 6.1.1


4      Test Types and Results
4.1      Radiated Emission and Bandedge Measurement
4.1.1     Limits of Radiated Emission and Bandedge Measurement

              Frequencies                        Field Strength                 Measurement Distance
                 (MHz)                         (microvolts/meter)                     (meters)
             0.009 ~ 0.490                        2400/F (kHz)                             300
             0.490 ~ 1.705                       24000/F (kHz)                             30
              1.705 ~ 30.0                              30                                 30
                 30 ~ 88                               100                                  3
                88 ~ 216                               150                                  3
               216 ~ 960                               200                                  3
               Above 960                               500                                  3
NOTE:
1. The lower limit shall apply at the transition frequencies.
2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
3. For frequencies below 1000 MHz, the field strength limits are based on average detector, however, the
      peak field strength of any emission shall not exceed the maximum permitted average limits, specified
      above by more than 20 dB under any condition of modulation.




Report No.: RF180227C27-10                      Page No. 8 / 26                        Report Format Version: 6.1.1


4.1.2    Test Instruments

        Description &                                                      Date of               Due Date of
                                  Model No.              Serial No.
        Manufacturer                                                      Calibration            Calibration
Test Receiver
                                    ESCI                  100424         Oct. 17, 2017          Oct. 16, 2018
ROHDE & SCHWARZ
Spectrum Analyzer
                                   FSP40                  100041         Dec. 12, 2017          Dec. 11, 2018
ROHDE & SCHWARZ
BILOG Antenna
                                 VULB9168                9168-171        Dec. 11, 2017          Dec. 10, 2018
SCHWARZBECK
HORN Antenna
                                    9120D                   209          Dec. 13, 2017          Dec. 12, 2018
SCHWARZBECK
HORN Antenna
                                 BBHA 9170           BBHA9170241         Dec. 01, 2017          Nov. 30, 2018
SCHWARZBECK
Fixed Attenuator
                               MDC9331N-20                 0724          Jun. 21, 2016          Jun. 20, 2018
Worken
Loop Antenna                        6509                 00217556        Aug. 31, 2017          Aug. 30, 2018
Preamplifier
                                 EMC001340                980201         Nov. 01, 2017          Oct. 31, 2018
EMCI
Bluetooth Tester                     CBT                  100946         Jul. 29, 2016           Jul. 28, 2018
Preamplifier
                                EMC 012645                980115         Oct. 20, 2017          Oct. 19, 2018
EMCI
Preamplifier
                                EMC 184045                980116         Oct. 20, 2017          Oct. 19, 2018
EMCI
Preamplifier
                                 EMC 330H                 980112         Oct. 20, 2017          Oct. 19, 2018
EMCI
High Speed Peak Power
                                  ML2495A                0824012         Aug. 18, 2017          Aug. 17, 2018
Meter
Power Sensor                      MA2411B              0738171           Aug. 18, 2017          Aug. 17, 2018
RF signal cable                                      Cable-CH3-03
                               SUCOFLEX 104                              Aug. 21, 2017          Aug. 20, 2018
HUBER+SUHNER                                          (223653/4)
RF signal cable                 SUCOFLEX
                                               Cable-CH3-03
HUBER+SUHNER&                104&EMC104-SM-S                             Sep.11, 2017           Sep. 10, 2018
                                             (309224+170907)
EMCI                              M-8000
RF Coaxial Cable
                                    8D-FB            Cable-Ch10-01       Oct. 20, 2017          Oct. 19, 2018
Worken
Software                             E3
                                                            NA                NA                       NA
BV ADT                            6.120103
Antenna Tower
                                  MFA-440H                  NA                NA                       NA
MF
Turn Table
                                 MFT-201SS                  NA                NA                       NA
MF
Antenna Tower &Turn
Table Controller                  MF-7802                   NA                NA                       NA
MF


Note: 1. The calibration interval of the above test instruments is 12 / 24 months and the calibrations are
         traceable to NML/ROC and NIST/USA.
        2. The test was performed in HwaYa Chamber 10.
        3. The horn antenna and preamplifier (model: EMC 184045) are used only for the measurement of
           emission frequency above 1GHz if tested.
        4. The IC Site Registration No. is IC7450F-10.




Report No.: RF180227C27-10                     Page No. 9 / 26                           Report Format Version: 6.1.1


4.1.3    Test Procedures

For Radiated Emission below 30 MHz
a.   The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter chamber
     room. The table was rotated 360 degrees to determine the position of the highest radiation.
b.   The EUT was set 3 meters away from the interference—receiving antenna, which was mounted on the top
     of a variable—height antenna tower.
c.   Both Parallel, perpendicular, and ground—paralle! orientations of the antenna are set to make the
     measurement.
d.   For each suspected emission, the EUT was arranged to its worst case and the rotatable table was turned
     from 0 degrees to 360 degrees to find the maximum reading.
e.   The test—receiver system was set to Quasi—Peak Detect Function and Specified Bandwidth with Maximum
     Hold Mode.
Note:
1.   The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 9 kHz at frequency
     below 30 MHz.
2.   The emission limits shown in the above table are based on measurements employing a CISPR
     quasi—peak detector except for the frequency bands 9 — 90 kHz, 110 — 490 kHz . Radiated emission limits
     in these two bands are based on measurements employing an average detector.


For Radiated Emission above 30 MHz
a.   The EUT was placed on the top of a rotating table 0.8 meters above the ground at 3 meter chamber room
     for test. The table was rotated 360 degrees to determine the position of the highest radiation.
b.   The EUT was set 3 meters away from the interference—receiving antenna, which was mounted on the top
     of a variable—height antenna tower.
c.   The height of antenna is varied from one meter to four meters above the ground to determine the
     maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
     make the measurement.
d.    For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
     heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find
     the maximum reading.
e.   The test—receiver system was set to quasi—peak detect function and specified bandwidth with maximum
     hold mode when the test frequency is below 1 GHz.
f.   The test—receiver system was set to peak and average detected function and specified bandwidth with
     maximum hold mode when the test frequencyis above 1 GHz. If the peak reading value also meets
     average limit, measurement with the average detector is unnecessary.
Note:
1.   The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 kHz for
     Quasi—peak detection (QP) at frequency below 1 GHz.
2.   All modes of operation were investigated and the worst—case emissions are reported.


4.1.4    Deviation from Test Standard

No deviation.




Report No.: RF180227G27—10                      Page No. 10 / 26                         Report Format Version: 6.1.1


4.1.5   Test Setup
 <Radiated Emission below 30 MHz>


                                                                                   1m
            EUT&                               3m
            Support Units

                                    Turn Table

               80 cm


                                            Ground Plane
                                            Test Receiver




 <Radiated Emission 30 MHz to 1 GHz>

                                                               Ant. Tower
                                                                                      1-4m
                                                                                      Variable
                                               3m
                                                10m
              EUT&
              Support Units

                                         Turn Table

                  80cm


                                              Ground Plane

                                              Test Receiver




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.1.6   EUT Operating Conditions

Set the EUT under transmission condition continuously at specific channel frequency.




Report No.: RF180227C27-10                      Page No. 11 / 26                           Report Format Version: 6.1.1


4.1.7    Test Results
Mode A
EUT Test Condition                                            Measurement Detail

 Input Power                     120 Vac, 60 Hz               Frequency Range                 0.009 ~ 30 MHz
Environmental                                                                                 Average
                                 25 deg. C, 65 % RH           Detector Function
Conditions                                                                                    Quasi-Peak
Tested By                        Jisyong Wang


                                  Antenna Polarity & Test Distance: Open at 3 m
            Emission     Read                            Antenna                   Preamp   Antenna        Table
Frequency                            Limit    Margin                     Cable
              Level      Level                            Factor                   Factor    Height       Angle      Remark
  (MHz)                            (dBuV/m)    (dB)                    Loss (dB)
            (dBuV/m)    (dBuV)                            (dB/m)                    (dB)      (cm)       (Degree)
   0.5       57.09      77.43       73.62     -16.53      20.25          0.06      40.65      100           360         QP
    1        45.95      66.29        67.6     -21.65      20.27          0.13      40.74      100           360         QP
   1.5       43.38      63.72       64.08       -20.7     20.28          0.15      40.77      100           360         QP
    2        41.39      61.73       69.54     -28.15      20.29          0.17       40.8      100           360         QP
   2.5       40.38      60.74       69.54     -29.16      20.32          0.18      40.86      100           360         QP
    3        39.72      60.09       69.54     -29.82      20.35          0.19      40.91      100           360         QP
   3.5       39.91      60.28       69.54     -29.63      20.39          0.19      40.95      100           360         QP
                                  Antenna Polarity & Test Distance: Close at 3 m
            Emission     Read                            Antenna                   Preamp   Antenna        Table
Frequency                            Limit    Margin                     Cable
              Level      Level                            Factor                   Factor    Height       Angle      Remark
  (MHz)                            (dBuV/m)    (dB)                    Loss (dB)
            (dBuV/m)    (dBuV)                            (dB/m)                    (dB)      (cm)       (Degree)
   0.5       53.31      73.65       73.62     -20.31      20.25          0.06      40.65      100            0          QP
    1        46.61      66.95        67.6     -20.99      20.27          0.13      40.74      100            0          QP
   1.5       43.87      64.21       64.08     -20.21      20.28          0.15      40.77      100            0          QP
    2        46.39      66.73       69.54     -23.15      20.29          0.17       40.8      100            0          QP
   2.5       44.38      64.74       69.54     -25.16      20.32          0.18      40.86      100            0          QP
    3        40.95      61.32       69.54     -28.59      20.35          0.19      40.91      100            0          QP
   3.5       46.87      67.24       69.54     -22.67      20.39          0.19      40.95      100            0          QP
                                 Antenna Polarity & Test Distance: Ground at 3 m
            Emission     Read                            Antenna                   Preamp   Antenna        Table
Frequency                            Limit    Margin                     Cable
              Level      Level                            Factor                   Factor    Height       Angle      Remark
  (MHz)                            (dBuV/m)    (dB)                    Loss (dB)
            (dBuV/m)    (dBuV)                            (dB/m)                    (dB)      (cm)       (Degree)
   0.5       51.59      71.93       73.62     -22.03      20.25          0.06      40.65      100           360         QP
    1        44.25      64.59        67.6     -23.35      20.27          0.13      40.74      100           360         QP
   1.5       41.95      62.29       64.08     -22.13      20.28          0.15      40.77      100           360         QP
    2        41.08      61.42       69.54     -28.46      20.29          0.17       40.8      100           360         QP
   2.5       40.82      61.18       69.54     -28.72      20.32          0.18      40.86      100           360         QP
    3         38.2      58.57       69.54     -31.34      20.35          0.19      40.91      100           360         QP
   3.5       38.63       59         69.54     -30.91      20.39          0.19      40.95      100           360         QP

Remarks:
1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m)
2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value.
5. Above limits have been translated by the formula




Report No.: RF180227C27-10                          Page No. 12 / 26                                Report Format Version: 6.1.1


 EUT Test Condition                                      Measurement Detail

 Input Power                 120 Vac, 60 Hz              Frequency Range      30 MHz ~ 1000 MHz
 Environmental
                             25 deg. C, 65 % RH          Detector Function    Peak
 Conditions
Tested By                    Jisyong Wang

Horizontal




Vertical




Report No.: RF180227C27-10                    Page No. 13 / 26                  Report Format Version: 6.1.1


                               Antenna Polarity & Test Distance: Horizontal at 3 m
            Emission      Read                             Antenna      Cable                 Antenna     Table
Frequency                                Limit    Margin                         Preamp
              Level       Level                             Factor      Loss                   Height    Angle     Remark
  (MHz)                                (dBuV/m)    (dB)                         Factor (dB)
            (dBuV/m)     (dBuV)                             (dB/m)       (dB)                   (cm)    (Degree)
  51.34       13.11      31.01           40       -26.89     12.87      0.54      31.31         152       231        Peak
  137.67      25.86      44.42           43.5     -17.64     12.21      0.92      31.69         165       214        Peak
  163.86      28.36          46.8        43.5     -15.14     12.34      1.04      31.82         111       152        Peak
  409.27      19.38      33.74           46       -26.62     15.52      2.12        32          102       231        Peak
  599.39      23.17      32.92           46       -22.83     19.59       2.9      32.24         165       258        Peak
  824.43      26.59      31.94           46       -19.41     22.54      3.76      31.65         111       165        Peak
                                    Antenna Polarity & Test Distance: Vertical at 3 m
            Emission      Read                             Antenna      Cable                 Antenna     Table
Frequency                                Limit    Margin                         Preamp
              Level       Level                             Factor      Loss                   Height    Angle     Remark
  (MHz)                                (dBuV/m)    (dB)                         Factor (dB)
            (dBuV/m)     (dBuV)                             (dB/m)       (dB)                   (cm)    (Degree)
  145.43      20.74      38.86           43.5     -22.76     12.54      0.96      31.62         185       214        Peak
  305.48      16.59      33.73           46       -29.41     13.08      1.68       31.9         111       165        Peak
  542.16      23.09      33.91           46       -22.91     18.28      2.67      31.77         203       211        Peak
  727.43      24.68      31.66           46       -21.32      21.2      3.43      31.61         211       165        Peak
  839.95       27.9      33.16           46       -18.1      22.74       3.8       31.8         120       231        Peak
  972.84      28.25      31.82           54       -25.75     23.92      4.34      31.83         111       195        Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
  Margin value = Emission level – Limit value.




Report No.: RF180227C27-10                           Page No. 14 / 26                             Report Format Version: 6.1.1


Mode B
EUT Test Condition                                          Measurement Detail

 Input Power                    120 Vac, 60 Hz              Frequency Range                 0.009 ~ 30 MHz
Environmental                                                                               Average
                                25 deg. C, 65 % RH          Detector Function
Conditions                                                                                  Quasi-Peak
Tested By                       Toby Tian


                                 Antenna Polarity & Test Distance: Open at 3 m
            Emission    Read                           Antenna                   Preamp   Antenna        Table
Frequency                           Limit    Margin                    Cable
              Level     Level                           Factor                   Factor    Height       Angle      Remark
  (MHz)                           (dBuV/m)    (dB)                   Loss (dB)
            (dBuV/m)   (dBuV)                           (dB/m)                    (dB)      (cm)       (Degree)
   0.4       62.53      82.94       95.56    -33.03     20.26          0.04      40.71      100           360      Average
   0.8        49.8      70.14       69.54    -19.74     20.26          0.11      40.71      100           360         QP
   1.2       46.48      66.82       66.02    -19.54     20.28          0.14      40.76      100           360         QP
   1.6       42.69      63.03       63.52    -20.83     20.28          0.16      40.78      100           360         QP
    2        41.39      61.73       69.54    -28.15     20.29          0.17       40.8      100           360         QP
   2.4       40.12      60.47       69.54    -29.42     20.32          0.18      40.85      100           360         QP
   2.8        40.5      60.87       69.54    -29.04     20.34          0.18      40.89      100           360         QP
                                 Antenna Polarity & Test Distance: Close at 3 m
            Emission    Read                           Antenna                   Preamp   Antenna        Table
Frequency                           Limit    Margin                    Cable
              Level     Level                           Factor                   Factor    Height       Angle      Remark
  (MHz)                           (dBuV/m)    (dB)                   Loss (dB)
            (dBuV/m)   (dBuV)                           (dB/m)                    (dB)      (cm)       (Degree)
   0.4       58.62      79.03       95.56    -36.94     20.26          0.04      40.71      100            0       Average
   0.8        47.8      68.14       69.54    -21.74     20.26          0.11      40.71      100            0          QP
   1.2       44.25      64.59       66.02    -21.77     20.28          0.14      40.76      100            0          QP
   1.6       42.39      62.73       63.52    -21.13     20.28          0.16      40.78      100            0          QP
    2        46.39      66.73       69.54    -23.15     20.29          0.17       40.8      100            0          QP
   2.4       44.76      65.11       69.54    -24.78     20.32          0.18      40.85      100            0          QP
   2.8       41.74      62.11       69.54    -27.8      20.34          0.18      40.89      100            0          QP
                                Antenna Polarity & Test Distance: Ground at 3 m
            Emission    Read                           Antenna                   Preamp   Antenna        Table
Frequency                           Limit    Margin                    Cable
              Level     Level                           Factor                   Factor    Height       Angle      Remark
  (MHz)                           (dBuV/m)    (dB)                   Loss (dB)
            (dBuV/m)   (dBuV)                           (dB/m)                    (dB)      (cm)       (Degree)
   0.4       58.44      78.85       95.56    -37.12     20.26          0.04      40.71      100           317      Average
   0.8        47.4      67.74       69.54    -22.14     20.26          0.11      40.71      100           317         QP
   1.2       43.56      63.9        66.02    -22.46     20.28          0.14      40.76      100           317         QP
   1.6       42.19      62.53       63.52    -21.33     20.28          0.16      40.78      100           317         QP
    2        41.08      61.42       69.54    -28.46     20.29          0.17       40.8      100           317         QP
   2.4       40.23      60.58       69.54    -29.31     20.32          0.18      40.85      100           317         QP
   2.8       38.35      58.72       69.54    -31.19     20.34          0.18      40.89      100           317         QP

Remarks:
1. Emission level (dBuV/m) = Raw Value (dBuV) + Correction Factor (dB/m)
2. Correction Factor (dB/m) = Antenna Factor (dB/m) + Cable Factor (dB) – Pre-Amplifier Factor (dB)
3. The other emission levels were very low against the limit.
4. Margin value = Emission level – Limit value.
5. Above limits have been translated by the formula




Report No.: RF180227C27-10                        Page No. 15 / 26                                Report Format Version: 6.1.1


 EUT Test Condition                                      Measurement Detail

 Input Power                 120 Vac, 60 Hz              Frequency Range      30 MHz ~ 1000 MHz
 Environmental
                             25 deg. C, 65 % RH          Detector Function    Peak
 Conditions
Tested By                    Jisyong Wang

Horizontal




Vertical




Report No.: RF180227C27-10                    Page No. 16 / 26                  Report Format Version: 6.1.1


                               Antenna Polarity & Test Distance: Horizontal at 3 m
            Emission      Read                             Antenna      Cable                 Antenna     Table
Frequency                                Limit    Margin                         Preamp
              Level       Level                             Factor      Loss                   Height    Angle     Remark
  (MHz)                                (dBuV/m)    (dB)                         Factor (dB)
            (dBuV/m)     (dBuV)                             (dB/m)       (dB)                   (cm)    (Degree)
  160.95      29.95      48.15           43.5     -13.55     12.63      1.03      31.86         125       231        Peak
   224        24.33      44.37           46       -21.67     10.38      1.35      31.77         111       165        Peak
  371.44      24.43      39.72           46       -21.57     14.66      1.97      31.92         253       121        Peak
  772.05       25.1      31.02           46       -20.9      21.83      3.58      31.33         165       251        Peak
  845.77      26.12      31.33           46       -19.88     22.81      3.82      31.84         111       102        Peak
  955.38      27.11      30.92           46       -18.89     23.82      4.25      31.88         185       214        Peak
                                    Antenna Polarity & Test Distance: Vertical at 3 m
            Emission      Read                             Antenna      Cable                 Antenna     Table
Frequency                                Limit    Margin                         Preamp
              Level       Level                             Factor      Loss                   Height    Angle     Remark
  (MHz)                                (dBuV/m)    (dB)                         Factor (dB)
            (dBuV/m)     (dBuV)                             (dB/m)       (dB)                   (cm)    (Degree)
  101.78      14.56      36.49           43.5     -28.94      9.25      0.76      31.94         132       256        Peak
  157.07      16.94      35.01           43.5     -26.56     12.72      1.01       31.8         152       231        Peak
  266.68      14.21          32.7        46       -31.79     11.97      1.52      31.98         165       251        Peak
  458.74      20.34      33.52           46       -25.66      16.5      2.31      31.99         132       251        Peak
  680.87      24.37          32.4        46       -21.63     20.59      3.22      31.84         165       214        Peak
  927.25      26.75      30.93           46       -19.25     23.66      4.15      31.99         201       231        Peak

Remarks:
1. Emission Level = Read Level + Antenna Factor + Cable Loss - Preamp Factor
  Margin value = Emission level – Limit value.




Report No.: RF180227C27-10                           Page No. 17 / 26                             Report Format Version: 6.1.1


4.2      Conducted Emission Measurement
4.2.1      Limits of Conducted Emission Measurement

                                                              Conducted Limit (dBuV)
         Frequency (MHz)
                                               Quasi-Peak                                  Average
             0.15 - 0.5                           66 - 56                                  56 - 46
             0.50 - 5.0                             56                                        46
             5.0 - 30.0                             60                                        50
Note:
1. The lower limit shall apply at the transition frequencies.
2. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50 MHz.
3. All emanations from a class A/B digital device or system, including any network of conductors and
      apparatus connected thereto, shall not exceed the level of field strengths specified above.


4.2.2      Test Instruments

        Description &                                                         Date of              Due Date of
                                  Model No.              Serial No.
        Manufacturer                                                         Calibration           Calibration
Test Receiver
                                     ESCI                   100613         Nov. 23, 2017           Nov. 22, 2018
ROHDE & SCHWARZ
RF signal cable (with
10dB PAD)                           5D-FB            Cable-cond1-01        Sep. 05, 2017           Sep. 04, 2018
Woken
LISN/AMN
ROHDE & SCHWARZ                    ESH3-Z5               835239/001        Mar. 06, 2018           Mar. 05, 2019
(EUT)
LISN/AMN
ROHDE & SCHWARZ                    ESH3-Z5                  100311         Aug. 15, 2017           Aug. 14, 2018
(Peripheral)
Software                       BV ADT_Cond_
                                                             NA                  NA                      NA
ADT                               V7.3.7.3

Note: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable
         to NML/ROC and NIST/USA.
      2. The test was performed in HwaYa Shielded Room 1.
      3. The VCCI Site Registration No. is C-2040.




Report No.: RF180227C27-10                       Page No. 18 / 26                          Report Format Version: 6.1.1


4.2.3   Test Procedures

a.   The EUT was placed 0.4 meters from the conducting wall of the shielded room with EUT being
     connected to the power mains through a line impedance stabilization network (LISN). Other support units
     were connected to the power mains through another LISN. The two LISNs provide 50 ohm/ 50 uH of
     coupling impedance for the measuring instrument.
b.   Both lines of the power mains connected to the EUT were checked for maximum conducted interference.
c.   The frequency range from 150 kHz to 30 MHz was searched. Emission levels under (Limit – 20 dB) was
     not recorded.


NOTE: The resolution bandwidth and video bandwidth of test receiver is 9 kHz for quasi-peak detection (QP)
        and average detection (AV) at frequency 0.15 MHz - 30 MHz.




Report No.: RF180227C27-10                    Page No. 19 / 26                       Report Format Version: 6.1.1


4.2.4   Deviation from Test Standard

No deviation.


4.2.5   Test Setup

                                   Vertical Ground
                                   Reference Plane                                Test Receiver

                     oi                                                            L___JI
                                                                                o o o o
                      40cm         EUT                                       E* 5 a o o




                                                        80cm
                      LISN
                               L                L1                           L
                                                        \            N
                                                                    Ho
                                                                                              T
                                                                      rizontal G
                                                                                 round
                                                                    Refere       Plane
                                                                           nce

                        Note: 1.Support units were connected to second LISN.




For the actual test configuration, please refer to the attached file (Test Setup Photo).


4.2.6   EUT Operating Conditions

Same as 4.1.6.




Report No.: RF180227G27—10                      Page No. 20 / 26                           Report Format Version: 6.1.1


4.2.7    Test Results
Mode A
                                                             Detector Function & Quasi—Peak (QP) /
Frequency Range           150kHz ~ 30MHz                     g{giglwultgl)fl              Average (AV), 3kHz


Input Power               120Vac, 60Hz                       Eg‘r’]';‘ii?o’:]‘:”‘a'      25°C, 65%RH
Tested by                 Getaz Yang                         Test Date                   2018/5/25

                                               Phase Of Power : Line (L)
         Frequency      |Correction|   Reading Value       Emission Level                    Limit                 Margin
 No                       Factor          (dBuV)                 (dBuV)                  (dBuV)                       (dB)
            (MHz)            (dB)      Q.P.       AV.       a.P.           AV.        Q.P.           AV.       Q.P.          AV.
  1       0.17744            10.10     31.15     15.90     41.25         26.00        64.60      54.60        —23.35      —28.60
  2       0.23602            10.11     23.93     7.65      34.04         17.76        62.24      52.24        —28.20      —34.48
  3       0.29120            10.11     17.39     2.38      27.50         12.49        60.49      50.49        —32.99      —38.00
  4       0.48422            10.12     25.24     10.57     35.36         20.69        56.27      46.27        —20.91      —25.58
  5       240216             10.21     10.88     4.77      21.09         14.98        56.00      46.00        —34.91      —31.02
  6      13.92884            10.85     16.64     0.81      27.49          11.66       60.00      50.00        —32.51      —38.34
Remarks:
          1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value




Report No.: RF180227G27—10                         Page No. 21 / 26                                    Report Format Version: 6.1.1


                                                              Detector Function & Quasi—Peak (QP) /
Frequency Range          150kHz ~ 30MHz                       g{giglwultgl)fl            Average (AV), 9kHz


Input Power              120Vac, 60Hz                         Eg‘r’]';‘ii?o”r:sma'      25°C, 65%RH
Tested by                Getaz Yang                           Test Date                 2018/5/25


                                              Phase Of Power : Neutral (N)
        Frequency      |Correction|   Reading Value         Emission Level                Limit               Margin
 No                      Factor            (dBuyV)              (dBuV)                    (dBuyV)              (dB)
           (MHz)          (dB)         Q.P.       AV.        Q.P      AV.             Q.P.       AV.      Q.P.       AV.
  1       0.15391        10.10        34.74      20.92      44.84    31.02           65.79      55.79    —20.95    —24.77
  2       0.17737        10.10        30.99      16.06      41.09    26.16           64.61      54.61    —23.52    —28.45
  3      0.22038             10.11    26.65      10.60      36.76        20.71       62.80     52.80     —26.04      —32.09
  4      0.48626             10.12    24.80      10.91      34.92        21.03       56.23     46.23     —21.31      —25.20
  5      244517              10.20    13.90      0.67       24.10        10.87       56.00     46.00     —31.90      —35.13
  6      14.72648            10.72    14.32      0.96       25.04        11.68       60.00     50.00     —34.96      —38.32
Remarks:
         1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value




Report No.: RF180227G27—10                          Page No. 22 / 26                              Report Format Version: 6.1.1


Mode B
                                                           Detector Function & Quasi—Peak (QP) /
Frequency Range          150kHz ~ 30MHz                    g{giglwultgl)fl      Average (AV), 9kHz

                                                           Environmental          s
Input Power              120Vac, 60Hz                      Conditions          25°C, 65%RH

Tested by                Getaz Yang                        Test Date           2018/5/25


                                             Phase Of Power : Line (L)
         Frequency     |Correction|   Reading Value      Emission Level          Limit               Margin
 No                      Factor            (dBuV)             (dBuV)             (dBuV)               (dB)
          (MHz)           (dB)         Q.P.       AV.     Q.P.      AV.      Q.P.      AV.       Q.P.       AV.
  1      0.16564         10.10        34.05     20.85    44.15     30.95    65.18     55.18     —21.03    —24.23
  2      0.20865         10.10        27.09     11.07    3719      21.17    63.26     53.26     —26.07    —32.09
  3      0.25166         10.11        22.80      8.26    32.91     18.37    61.70     51.70     —28.79    —33.33
  4      0.48550         10.12        25.15     10.25    35.27     20.37    56.24     46.24     —20.97    —25.87
  5      241780          10.21        13.02      0.91    23.23     11.12    56.00     46.00     —32.77    —34.88
  6      14.30811        10.88        16.17      0.97    27.05     11.85    60.00     50.00     —32.95    —38.15
Remarks:
         1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value




Report No.: RF180227G27—10                       Page No. 23 / 26                        Report Format Version: 6.1.1


                                                              Detector Function & Quasi—Peak (QP) /
Frequency Range          150kHz ~ 30MHz                       g{giglwultgl)fl            Average (AV), 9kHz


Input Power              120Vac, 60Hz                         Eg‘r’]';‘ii?o”r:sma'      25°C, 65%RH
Tested by                Getaz Yang                           Test Date                 2018/5/25


                                              Phase Of Power : Neutral (N)
        Frequency      |Correction|   Reading Value         Emission Level                Limit               Margin
 No                      Factor            (dBuyV)              (dBuV)                    (dBuyV)              (dB)
           (MHz)          (dB)         Q.P.       AV.        Q.P      AV.             Q.P.       AV.      Q.P.       AV.
  1       0.16173        10.10        34.26      21.68      44.36    31.78           65.37      55.37    —21.01    —23.59
  2       0.20031        10.10        28.45      13.09      38.55    23.19           63.60      53.60    —25.05    —30.41
  3       0.22434        10.11        25.53      10.31      35.64    20.42           62.66      52.66    —27.02    —32.24
  4       0.47915        10.12        24.82      18.42      34.94        28.54       56.35     46.35     —21.41      —17.81
  5      2.27704             10.19    13.26       0.14      23.45        10.33       56.00     46.00     —32.55      —35.67
  6      14.71475            10.72    14.99       0.60      25.71        11.32       60.00     50.00     —34.29      —38.68
Remarks:
         1. Q.P. and AV. are abbreviations of quasi—peak and average individually.
         2. The emission levels of other frequencies were very low against the limit.
         3. Margin value = Emission level — Limit value
         4. Correction factor = Insertion loss + Cable loss
         5. Emission Level = Correction Factor + Reading Value




Report No.: RF180227G27—10                          Page No. 24 / 26                              Report Format Version: 6.1.1


5    Pictures of Test Arrangements

Please refer to the attached file (Test Setup Photo).




Report No.: RF180227C27-10                     Page No. 25 / 26   Report Format Version: 6.1.1


Appendix – Information on the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are FCC
recognized accredited test firms and accredited according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab                                       Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                    Tel: 886-3-6668565
Fax: 886-2-26051924                                    Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: RF180227C27-10                     Page No. 26 / 26                  Report Format Version: 6.1.1



Document Created: 2018-06-22 13:23:28
Document Modified: 2018-06-22 13:23:28

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC