          FCC SAR Test Report                                                     Report No. : FA710507-03




                            FCC SAR Test Report

                           APPLICANT          : Getac Technology Corporation.
                           EQUIPMENT          : WLAN Module
                           BRAND NAME         : AMPAK
                           MODEL NAME         : AP6234
                           FCC ID             : QYLAP6234E
                           STANDARD           : FCC 47 CFR Part 2 (2.1093)
                                                ANSI/IEEE C95.1-1992
                                                IEEE 1528-2013

      The product was installed into Tablet (Brand Name Getac, Model Name: EX80) during test.

      We, SPORTON INTERNATIONAL INC., would like to declare that the tested sample has been
      evaluated in accordance with the procedures and had been in compliance with the
      applicable technical standards.

      The test results in this report apply exclusively to the tested model / sample. Without
      written approval of SPORTON INTERNATIONAL INC., the test report shall not be
      reproduced except in full.




           Reviewed by: Eric Huang / Manager




           Approved by: Jones Tsai / Manager



                                  SPORTON INTERNATIONAL INC.
No.52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei-Shan District, Taoyuan City, Taiwan (R.O.C.)




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                   Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                 Page 1 of 31             Form version. : 160427


              FCC SAR Test Report                                                                                                            Report No. : FA710507-03

                                                                Table of Contents
1. Statement of Compliance ............................................................................................................................................. 4
2. Administration Data ...................................................................................................................................................... 5
3. Guidance Applied .......................................................................................................................................................... 5
4. Equipment Under Test (EUT) Information ................................................................................................................... 6
     4.1 General Information ............................................................................................................................................... 6
5. RF Exposure Limits....................................................................................................................................................... 7
     5.1 Uncontrolled Environment ...................................................................................................................................... 7
     5.2 Controlled Environment .......................................................................................................................................... 7
6. Specific Absorption Rate (SAR) ................................................................................................................................... 8
     6.1 Introduction ............................................................................................................................................................ 8
     6.2 SAR Definition ........................................................................................................................................................ 8
7. System Description and Setup .................................................................................................................................... 9
     7.1 E-Field Probe ........................................................................................................................................................10
     7.2 Data Acquisition Electronics (DAE) .......................................................................................................................10
     7.3 Phantom ................................................................................................................................................................ 11
     7.4 Device Holder........................................................................................................................................................12
8. Measurement Procedures ...........................................................................................................................................13
     8.1 Spatial Peak SAR Evaluation ................................................................................................................................13
     8.2 Power Reference Measurement............................................................................................................................14
     8.3 Area Scan .............................................................................................................................................................14
     8.4 Zoom Scan ............................................................................................................................................................15
     8.5 Volume Scan Procedures ......................................................................................................................................15
     8.6 Power Drift Monitoring ...........................................................................................................................................15
9. Test Equipment List .....................................................................................................................................................16
10. System Verification ....................................................................................................................................................17
     10.1 Tissue Simulating Liquids ....................................................................................................................................17
     10.2 Tissue Verification ...............................................................................................................................................18
     10.3 System Performance Check Results...................................................................................................................19
11. RF Exposure Positions ..............................................................................................................................................19
     11.1 SAR Testing for Tablet .........................................................................................................................................19
12. Conducted RF Output Power (Unit: dBm) ................................................................................................................20
13. Bluetooth Exclusions Applied ..................................................................................................................................23
14. Antenna Location .......................................................................................................................................................24
15. SAR Test Results .......................................................................................................................................................26
     15.1 Body SAR ...........................................................................................................................................................27
16. Uncertainty Assessment ...........................................................................................................................................28
17. References ..................................................................................................................................................................31
Appendix A. Plots of System Performance Check
Appendix B. Plots of High SAR Measurement
Appendix C. DASY Calibration Certificate
Appendix D. Test Setup Photos




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                                                            Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                                                  Page 2 of 31                                     Form version. : 160427


          FCC SAR Test Report                                                   Report No. : FA710507-03



                                              Revision History
   REPORT NO.           VERSION                              DESCRIPTION              ISSUED DATE

   FA710507-03            Rev. 01       Initial issue of report                        May. 05, 2017




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                 Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                        Page 3 of 31    Form version. : 160427


          FCC SAR Test Report                                                   Report No. : FA710507-03
1. Statement of Compliance
The maximum results of Specific Absorption Rate (SAR) found during testing for Getac Technology
Corporation., WLAN Module, AP6234, are as follows.


                                                                          Highest SAR Summary
               Equipment                             Frequency                    Body
                 Class                                 Band                 (Separation 0mm)
                                                                              1g SAR (W/kg)
                  DTS                               2.4GHz WLAN                    0.26
                  NII                                5GHz WLAN                     0.78
                                 Date of Testing:                          2017/3/8 ~ 2017/3/9

This device is in compliance with Specific Absorption Rate (SAR) for general population/uncontrolled
exposure limits (1.6 W/kg) specified in FCC 47 CFR part 2 (2.1093) and ANSI/IEEE C95.1-1992, and had
been tested in accordance with the measurement methods and procedures specified in IEEE 1528-2013 and
FCC KDB publications




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                 Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                    Page 4 of 31        Form version. : 160427


seorrow cas._FCC SAR Test Report                                                                  Report No. : FA710507—03
  2. Administration Data
                                                     Testing Laboratory
  KESecnc                            SPORTON INTERNATIONAL INC.
                                     No.52, Hwa Ya 1st Rd., Hwa Ya Technology Park, Kwei—Shan District, Taoyuan City,
                                     Taiwan (R.O.C.)
  Test Site Location
                                     TEL: +886—3—327—3456
                                     FAX: +886—3—328—4978

                                                          Applicant
 Company Name                       Getac Technology Corporation.
 ob                                 5F., Building A, No. 209, Sec.1, Nangang Rd.,Nangang Dist., Taipei City 11568, Taiwan,
                                    R.0.G.

                                                        Manufacturer
 Company Name                       AMPAK Technology Inc.
 Address                            NO.1 Jen Ai Road, Hsinchu Industrial Park, Hukou, HsinChu, Taiwan




  3. Guidance Applied
      The Specific Absorption Rate (SAR) testing specification, method, and procedure for this device is in accordance with
      the following standards:
       >     FCC 47 CFR Part 2 (2.1093)
             ANSVIEEE C95.1—1992
             IEEE 1528—2013
             FCC KDB 865664 D01 SAR Measurement 100 MHz to 6 GHz v01r04
             FCC KDB 865664 D02 SAR Reporting v01r02
             FCC KDB 447498 DO1 General RF Exposure Guidance v06
             FCC KDB 248227 D01 802.11 Wi—Fi SAR v02r02
             FCC KDB 616217 D04 SAR for laptop and tablets v01r02




  SPORTON INTERNATIONAL INC.
  TEL : 886—3—327—3456 / FAX : 886—3—328—4978                                                 Issued Date : May. 05, 2017
  FCC ID : QYLAPG234E                                       Page 5 of 31                     Form version. : 160427


          FCC SAR Test Report                                                            Report No. : FA710507-03
4. Equipment Under Test (EUT) Information
4.1 General Information
                                      Product Feature & Specification
Equipment Name          WLAN Module
Brand Name              AMPAK
Model Name              AP6234
FCC ID                  QYLAP6234E
                        WLAN 2.4GHz Band: 2412 MHz ~ 2462 MHz
                        WLAN 5.2GHz Band: 5180 MHz ~ 5240 MHz
Wireless Technology and WLAN 5.3GHz Band: 5260 MHz ~ 5320 MHz
Frequency Range         WLAN 5.5GHz Band: 5500 MHz ~ 5700 MHz
                        WLAN 5.8GHz Band: 5745 MHz ~ 5805 MHz
                        Bluetooth: 2402 MHz ~ 2480 MHz
                        802.11a/b/g/n HT20/HT40
Mode
                        Bluetooth BR/EDR/LE
Remark:
1. WLAN and Bluetooth share the same antenna, and cannot transmit simultaneously.


                                        Host Information
Equipment Name                Tablet
Brand Name                    Getac
Model Name                    EX80
                              Brand Name: Jogtek
Integrated NFC Module
                              Model Name: TRF7970A
Wireless Technology and
                        NFC : 13.56 MHz
Frequency Range
Mode                    NFC:ASK
EUT Stage               Production Unit




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                          Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                        Page 6 of 31             Form version. : 160427


          FCC SAR Test Report                                                                  Report No. : FA710507-03
5. RF Exposure Limits
5.1 Uncontrolled Environment
Uncontrolled Environments are defined as locations where there is the exposure of individuals who have no knowledge or
control of their exposure. The general population/uncontrolled exposure limits are applicable to situations in which the
general public may be exposed or in which persons who are exposed as a consequence of their employment may not be
made fully aware of the potential for exposure or cannot exercise control over their exposure. Members of the general
public would come under this category when exposure is not employment-related; for example, in the case of a wireless
transmitter that exposes persons in its vicinity.


5.2 Controlled Environment
Controlled Environments are defined as locations where there is exposure that may be incurred by persons who are
aware of the potential for exposure, (i.e. as a result of employment or occupation). In general, occupational/controlled
exposure limits are applicable to situations in which persons are exposed as a consequence of their employment, who
have been made fully aware of the potential for exposure and can exercise control over their exposure. The exposure
category is also applicable when the exposure is of a transient nature due to incidental passage through a location where
the exposure levels may be higher than the general population/uncontrolled limits, but the exposed person is fully aware
of the potential for exposure and can exercise control over his or her exposure by leaving the area or by some other
appropriate means.


                               Limits for Occupational/Controlled Exposure (W/kg)




                         Limits for General Population/Uncontrolled Exposure (W/kg)




     1.   Whole-Body SAR is averaged over the entire body, partial-body SAR is averaged over any 1gram of tissue
          defined as a tissue volume in the shape of a cube. SAR for hands, wrists, feet and ankles is averaged over any
          10 grams of tissue defined as a tissue volume in the shape of a cube.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                      Page 7 of 31                     Form version. : 160427


          FCC SAR Test Report                                                                       Report No. : FA710507-03
6. Specific Absorption Rate (SAR)
6.1 Introduction
    SAR is related to the rate at which energy is absorbed per unit mass in an object exposed to a radio field. The SAR
    distribution in a biological body is complicated and is usually carried out by experimental techniques or numerical
    modeling. The standard recommends limits for two tiers of groups, occupational/controlled and general
    population/uncontrolled, based on a person’s awareness and ability to exercise control over his or her exposure. In
    general, occupational/controlled exposure limits are higher than the limits for general population/uncontrolled.


6.2 SAR Definition
    The SAR definition is the time derivative (rate) of the incremental energy (dW) absorbed by (dissipated in) an
    incremental mass (dm) contained in a volume element (dv) of a given density (ρ). The equation description is as
    below:
                                                        � ��    � ��
                                               � =        (   )= (    )
                                                        �� ��   �� ���
    SAR is expressed in units of Watts per kilogram (W/kg)

                                                              �|�|�
                                                          � =
                                                                �
    Where: σ is the conductivity of the tissue, ρ is the mass density of the tissue and E is the RMS electrical field strength.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                    Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                         Page 8 of 31                      Form version. : 160427


          FCC SAR Test Report                                                          Report No. : FA710507-03
7. System Description and Setup
The DASY system used for performing compliance tests consists of the following items:




     A standard high precision 6-axis robot with controller, teach pendant and software. An arm extension for
      accommodating the data acquisition electronics (DAE).
     An isotropic Field probe optimized and calibrated for the targeted measurement.
     A data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing,
      AD-conversion, offset measurements, mechanical surface detection, collision detection, etc. The unit is
      battery powered with standard or rechargeable batteries. The signal is optically transmitted to the EOC.
     The Electro-optical converter (EOC) performs the conversion from optical to electrical signals for the
      digital communication to the DAE. To use optical surface detection, a special version of the EOC is
      required. The EOC signal is transmitted to the measurement server.
     The function of the measurement server is to perform the time critical tasks such as signal filtering,
      control of the robot operation and fast movement interrupts.
     The Light Beam used is for probe alignment. This improves the (absolute) accuracy of the probe
      positioning.
     A computer running WinXP or Win7 and the DASY5 software.
     Remote control and teach pendant as well as additional circuitry for robot safety such as warning lamps,
      etc.
     The phantom, the device holder and other accessories according to the targeted measurement.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                        Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                 Page 9 of 31                  Form version. : 160427


seorron ias._FCC SAR Test Report                                                                    Report No. : FA710507—03
  7.1 E—Field Probe
  The SAR measurement is conducted with the dosimetric probe (manufactured by SPEAG).The probe is specially
  designed and calibrated for use in liquid with high permittivity. The dosimetric probe has special calibration in liquid at
  different frequency. This probe has a built in optical surface detection system to prevent from collision with phantom.


  <ES3DV3 Probe>
  Construction              Symmetric design with triangular core
                            Interleaved sensors
                            Built—in shielding against static charges
                            PEEK enclosure material (resistant to organic
                            solvents, e.g., DGBE)
  Frequency                 10 MHz — 4 GHz;
                            Lingarity: +0.2 dB (30 MHz — 4 GHz)
  Directivity               £0.2 dB in TSL (rotation around probe axis)
                            20.3 dB in TSL (rotation normal to probe axis)
  Dynamic Range             5 uW/g —>100 mWig;
                            Linearity: 40.2 dB
  Dimensions                Overall length: 337 mm (tip: 20 mm)
                            Tip diameter: 3.9 mm (body: 12 mm)
                            Distance from probetip to dipole centers: 3.0 mm


  <EX3DV4 Probe>
  Construction              Symmetric design with triangular core
                            Built—in shielding against static charges
                            PEEK enclosure material (resistant to organic
                            solvents, e.g., DGBE)
  Frequency                 10 MHz —>6 GHz
                            Lingarity: +0.2 dB (30 MHz — 6 GHz)
  Directivity               20.3 dB in TSL (rotation around probe axis)
                            20.5 dB in TSL (rotation normal to probe axis)
  Dynamic Range             10 uW/g —>100 mW/g
                            Linearity: 40.2 dB (noise: typically <1 uW/g)
  Dimensions                Overall length: 337 mm (tip: 20 mm
                            Tip diameter: 2.5 mm (body: 12 mm)
                            Typical distance from probetip to dipole centers: 1
                            mm



  7.2 Data Acquisition Electronics (DAE)
  The data acquisition electronics (DAE) consists of a highly sensitive
  electrometer—grade     preamplifier   with    auto—zeroing,     a   channel   and
  gain—switching multiplexer, a fast 16 bit AD—converter and a command
  decoder and control logic unit. Transmission to the measurement server is
  accomplished through an optical downlink for data and status information as
  well as an optical uplink for commands and the clock.
  The input impedance of the DAE is 200 MOhm; the inputs are symmetrical
  and floating. Common mode rejection is above 80 dB.                                     Fig 5.1      Photo of DAE




  SPORTON INTERNATIONAL INC.
  TEL : 886—3—327—3456 / FAX : 886—3—328—4978                                                  Issued Date : May. 05, 2017
                                                                Page 10 of 31                 Form version. : 160427
  FCC ID : QYLAPG234E


      FCC SAR Test Report                                                                        Report No. : FA710507-03
7.3 Phantom
<SAM Twin Phantom>
Shell Thickness              2 ± 0.2 mm;
                             Center ear point: 6 ± 0.2 mm
Filling Volume               Approx. 25 liters
Dimensions                   Length: 1000 mm; Width: 500 mm; Height:
                             adjustable feet
Measurement Areas            Left Hand, Right Hand, Flat Phantom




The bottom plate contains three pair of bolts for locking the device holder. The device holder positions are adjusted to the
standard measurement positions in the three sections. A white cover is provided to tap the phantom during off-periods to
prevent water evaporation and changes in the liquid parameters. On the phantom top, three reference markers are
provided to identify the phantom position with respect to the robot.



<ELI Phantom>
Shell Thickness          2 ± 0.2 mm (sagging: <1%)
Filling Volume           Approx. 30 liters
Dimensions               Major ellipse axis: 600 mm
                         Minor axis: 400 mm




The ELI phantom is intended for compliance testing of handheld and body-mounted wireless devices in the frequency
range of 30 MHz to 6 GHz. ELI4 is fully compatible with standard and all known tissue simulating liquids.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                  Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                       Page 11 of 31                     Form version. : 160427


      FCC SAR Test Report                                                                         Report No. : FA710507-03
7.4 Device Holder
<Mounting Device for Hand-Held Transmitter>
In combination with the Twin SAM V5.0/V5.0c or ELI phantoms, the Mounting Device for Hand-Held Transmitters enables
rotation of the mounted transmitter device to specified spherical coordinates. At the heads, the rotation axis is at the ear
opening. Transmitter devices can be easily and accurately positioned according to IEC 62209-1, IEEE 1528, FCC, or
other specifications. The device holder can be locked for positioning at different phantom sections (left head, right head,
flat). And upgrade kit to Mounting Device to enable easy mounting of wider devices like big smart-phones, e-books, small
tablets, etc. It holds devices with width up to 140 mm.




                           Mounting Device for Hand-Held
                                                                Mounting Device Adaptor for Wide-Phones
                                   Transmitters




<Mounting Device for Laptops and other Body-Worn Transmitters>
The extension is lightweight and made of POM, acrylic glass and foam. It fits easily on the upper part of the mounting
device in place of the phone positioned. The extension is fully compatible with the SAM Twin and ELI phantoms.




                                                 Mounting Device for Laptops




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                   Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                        Page 12 of 31                     Form version. : 160427


           FCC SAR Test Report                                                                     Report No. : FA710507-03
8. Measurement Procedures
   The measurement procedures are as follows:

   <Conducted power measurement>
   (a) For WWAN power measurement, use base station simulator to configure EUT WWAN transmission in conducted
       connection with RF cable, at maximum power in each supported wireless interface and frequency band.
   (b) Read the WWAN RF power level from the base station simulator.
   (c) For WLAN/BT power measurement, use engineering software to configure EUT WLAN/BT continuously
       transmission, at maximum RF power in each supported wireless interface and frequency band
   (d) Connect EUT RF port through RF cable to the power meter, and measure WLAN/BT output power

   <SAR measurement>
   (a) Use base station simulator to configure EUT WWAN transmission in radiated connection, and engineering
       software to configure EUT WLAN/BT continuously transmission, at maximum RF power, in the highest power
       channel.
   (b) Place the EUT in the positions as Appendix D demonstrates.
   (c) Set scan area, grid size and other setting on the DASY software.
   (d) Measure SAR results for the highest power channel on each testing position.
   (e) Find out the largest SAR result on these testing positions of each band
   (f) Measure SAR results for other channels in worst SAR testing position if the reported SAR of highest power
       channel is larger than 0.8 W/kg

         According to the test standard, the recommended procedure for assessing the peak spatial-average SAR value
         consists of the following steps:
   (a)     Power reference measurement
   (b)     Area scan
   (c)     Zoom scan
   (d)     Power drift measurement


8.1 Spatial Peak SAR Evaluation
     The procedure for spatial peak SAR evaluation has been implemented according to the test standard. It can be
     conducted for 1g and 10g, as well as for user-specific masses. The DASY software includes all numerical
     procedures necessary to evaluate the spatial peak SAR value.
     The base for the evaluation is a "cube" measurement. The measured volume must include the 1g and 10g cubes
     with the highest averaged SAR values. For that purpose, the center of the measured volume is aligned to the
     interpolated peak SAR value of a previously performed area scan.
     The entire evaluation of the spatial peak values is performed within the post-processing engine (SEMCAD). The
     system always gives the maximum values for the 1g and 10g cubes. The algorithm to find the cube with highest
     averaged SAR is divided into the following stages:
     (a)    Extraction of the measured data (grid and values) from the Zoom Scan
     (b)    Calculation of the SAR value at every measurement point based on all stored data (A/D values and
            measurement parameters)
     (c)    Generation of a high-resolution mesh within the measured volume
     (d)    Interpolation of all measured values form the measurement grid to the high-resolution grid
     (e)    Extrapolation of the entire 3-D field distribution to the phantom surface over the distance from sensor to surface
     (f)    Calculation of the averaged SAR within masses of 1g and 10g




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                    Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                        Page 13 of 31                      Form version. : 160427


      FCC SAR Test Report                                                                       Report No. : FA710507-03
8.2 Power Reference Measurement
The Power Reference Measurement and Power Drift Measurements are for monitoring the power drift of the device under
test in the batch process. The minimum distance of probe sensors to surface determines the closest measurement point
to phantom surface. This distance cannot be smaller than the distance of sensor calibration points to probe tip as defined
in the probe properties.


8.3 Area Scan
The area scan is used as a fast scan in two dimensions to find the area of high field values, before doing a fine
measurement around the hot spot. The sophisticated interpolation routines implemented in DASY software can find the
maximum found in the scanned area, within a range of the global maximum. The range (in dB0 is specified in the
standards for compliance testing. For example, a 2 dB range is required in IEEE standard 1528 and IEC 62209 standards,
whereby 3 dB is a requirement when compliance is assessed in accordance with the ARIB standard (Japan), if only one
zoom scan follows the area scan, then only the absolute maximum will be taken as reference. For cases where multiple
maximums are detected, the number of zoom scans has to be increased accordingly.
Area scan parameters extracted from FCC KDB 865664 D01v01r04 SAR measurement 100 MHz to 6 GHz.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                 Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                      Page 14 of 31                     Form version. : 160427


       FCC SAR Test Report                                                                      Report No. : FA710507-03
8.4 Zoom Scan
Zoom scans are used assess the peak spatial SAR values within a cubic averaging volume containing 1 gram and 10
gram of simulated tissue. The zoom scan measures points (refer to table below) within a cube shoes base faces are
centered on the maxima found in a preceding area scan job within the same procedure. When the measurement is done,
the zoom scan evaluates the averaged SAR for 1 gram and 10 gram and displays these values next to the job’s label.
Zoom scan parameters extracted from FCC KDB 865664 D01v01r04 SAR measurement 100 MHz to 6 GHz.




8.5 Volume Scan Procedures
The volume scan is used for assess overlapping SAR distributions for antennas transmitting in different frequency bands.
It is equivalent to an oversized zoom scan used in standalone measurements. The measurement volume will be used to
enclose all the simultaneous transmitting antennas. For antennas transmitting simultaneously in different frequency bands,
the volume scan is measured separately in each frequency band. In order to sum correctly to compute the 1g aggregate
SAR, the EUT remain in the same test position for all measurements and all volume scan use the same spatial resolution
and grid spacing. When all volume scan were completed, the software, SEMCAD postprocessor can combine and
subsequently superpose these measurement data to calculating the multiband SAR.


8.6 Power Drift Monitoring
All SAR testing is under the EUT install full charged battery and transmit maximum output power. In DASY measurement
software, the power reference measurement and power drift measurement procedures are used for monitoring the power
drift of EUT during SAR test. Both these procedures measure the field at a specified reference position before and after
the SAR testing. The software will calculate the field difference in dB. If the power drifts more than 5%, the SAR will be
retested.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                 Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                      Page 15 of 31                     Form version. : 160427


           FCC SAR Test Report                                                                 Report No. : FA710507-03
9. Test Equipment List
                                                                                                    Calibration
Manufacturer           Name of Equipment           Type/Model        Serial Number
                                                                                           Last Cal.            Due Date
   SPEAG          2450MHz System Validation Kit      D2450V2                 926         Jul. 25, 2016      Jul. 24, 2017
   SPEAG            5GHz System Validation Kit      D5GHzV2                 1040         Jun. 17, 2016      Jun. 16, 2017
   SPEAG            Data Acquisition Electronics      DAE4                   914         Jan. 06, 2017      Jan. 05, 2018
   SPEAG             Dosimetric E-Field Probe        EX3DV4                 3578         May. 11, 2016      May. 10, 2017
   WonDer                  Thermometer               WD-5015               TM685         Oct. 12, 2016      Oct. 11, 2017
   SPEAG                  Device Holder                N/A                   N/A              N/A                 N/A
   Anritsu               Signal Generator           MG3710A           6201502524         Dec. 09, 2016      Dec. 08, 2017
    Agilent           ENA Network Analyzer           E5071C           MY46316648         Jan. 04, 2017      Jan. 03, 2018
   SPEAG                Dielectric Probe Kit         DAK-3.5                1126         Jul. 19, 2016      Jul. 18, 2017
 LINE SEIKI            Digital Thermometer         LKMelectronic   DTM3000SPEZIAL        Sep. 05, 2016      Sep. 04, 2017
   Anritsu                 Power Meter               ML2495A               1419002       May. 10, 2016      May. 09, 2017
   Anritsu                Power Sensor              MA2411B                1339124       May. 10, 2016      May. 09, 2017
   Anritsu              Spectrum Analyzer           MS2830A           6201396378         Jun. 21, 2016      Jun. 20, 2017
 Mini-Circuits            Power Amplifier            ZVE-8G+               D120604       Mar. 16, 2016      Mar. 15, 2017
 Mini-Circuits            Power Amplifier           ZHL-42W+              QA1344002      Mar. 16, 2016      Mar. 15, 2017
     ATM             Dual Directional Coupler       C122H-10          P610410z-02                      Note 1
   Woken                   Attenuator 1            WK0602-XX                 N/A                       Note 1
     PE                    Attenuator 2             PE7005-10                N/A                       Note 1
     PE                    Attenuator 3             PE7005- 3                N/A                       Note 1
General Note:
 1.  Prior to system verification and validation, the path loss from the signal generator to the system check source and
     the power meter, which includes the amplifier, cable, attenuator and directional coupler, was measured by the
     network analyzer. The reading of the power meter was offset by the path loss difference between the path to the
     power meter and the path to the system check source to monitor the actual power level fed to the system check
     source.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                       Page 16 of 31                   Form version. : 160427


          FCC SAR Test Report                                                           Report No. : FA710507-03
10. System Verification
10.1 Tissue Simulating Liquids
    For the measurement of the field distribution inside the SAM phantom with DASY, the phantom must be
    filled with around 25 liters of homogeneous body tissue simulating liquid. For head SAR testing, the liquid
    height from the ear reference point (ERP) of the phantom to the liquid top surface is larger than 15 cm,
    which is shown in Fig. 10.1. For body SAR testing, the liquid height from the center of the flat phantom to
    the liquid top surface is larger than 15 cm, which is shown in Fig. 10.2.




       Fig 10.1Photo of Liquid Height for Head SAR           Fig 10.2 Photo of Liquid Height for Body SAR




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                         Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                  Page 17 of 31                 Form version. : 160427


seorrow cas._FCC SAR Test Report                                                                                     Report No. : FA710507—03


  10.2 Tissue Verification
  The following tissue formulations are provided for reference only as some of the parameters have not been
  thoroughly verified. The composition of ingredients may be modified accordingly to achieve the desired target
  tissue parameters required for routine SAR evaluation.



            750                    41.1                      .           1.4
            835                    40.3                      .           1.4
            900                    40.3                      .           1.4
   1800, 1900, 2000                55.2                                  0.3
         2450                      55.0                                   0
         2600                      54.8                                  0.1


            750                    51.7                                  0.9            0.1
            835                    50.8                                  0.9            0.1
            900                    50.8                                  0.9            0.1
   1800, 1900, 2000                70.2          0                       0.4             0
         2450                      68.6          0                        0              0
         2600                      68.1          0                       0.1             0


  Simulating Liquid for 5GHz, Manufactured by SPEAG

                         Water                                     64~78%
                     Mineral oil                                   11~18%
                     Emulsifiers                                    9~15%
                  Additives and Sait                                2~3%



  <Tissue Dielectric Parameter Check Results>
  Frequency Tissue          .I;Lqr:;j     Conductivity Permittivity Conductivity Permittivity   Delta (0)   Delta (;)   ooo         Date
    (MHz)    Type             t                (0)         C         Target(0) Target (s,)        (%)          (%)

     2450          MSL       22.6            1.980        54.067        1.95           52.70     1.54         2.59        +5      20177379
     5300          MSL       22.4            5.564        46.733        5.42           48.90     2.66        —4.43        +5      2017/3/8
     5600          MSL       22.4            5.963        46.212        5.77           48.50     3.34        —4.72        +5      2017/3/8
     5800          MSL       22.4            6.237        45.880        6.00           48.20     3.95        —4.81        +5      2017/3/8




  SPORTON INTERNATIONAL INC.
  TEL : 886—3—327—3456 / FAX : 886—3—328—4978                                                                 Issued Date : May. 05, 2017
  FCC ID : QYLAPG234E                                                  Page 18 of 31                         Form version. : 160427


       FCC SAR Test Report                                                                      Report No. : FA710507-03
10.3 System Performance Check Results
Comparing to the original SAR value provided by SPEAG, the verification data should be within its specification of 10 %.
Below table shows the target SAR and measured SAR after normalized to 1W input power. The table below indicates the
system performance check can meet the variation criterion and the plots can be referred to Appendix A of this report.
                              Input                                       Measured Targeted Normalized
             Frequency Tissue         Dipole        Probe          DAE                                 Deviation
   Date                       Power                                        1g SAR 1g SAR     1g SAR
               (MHz)    Type            S/N          S/N           S/N                                   (%)
                              (mW)                                         (W/kg)   (W/kg)    (W/kg)
 2017/3/9       2450    MSL    250  D2450V2-926 EX3DV4 - SN3578 DAE4 Sn914 13.10     51.20     52.40     2.34
 2017/3/8      5300     MSL     100   D5GHzV2-1040 EX3DV4 - SN3578 DAE4 Sn914      8.33      76.40      83.30      9.03
 2017/3/8      5300     MSL     100   D5GHzV2-1040 EX3DV4 - SN3578 DAE4 Sn914      8.53      78.40      85.30      8.80
 2017/3/8      5600     MSL     100   D5GHzV2-1040 EX3DV4 - SN3578 DAE4 Sn914      7.45      75.20      74.50      -0.93




            Fig 8.3.1 System Performance Check Setup                                      Fig 8.3.2 Setup Photo




11. RF Exposure Positions
11.1 SAR Testing for Tablet
This device can be used also in full sized tablet exposure conditions, due to its size. Per FCC KDB 616217, the back
surface and edges of the tablet should be tested for SAR compliance with the tablet touching the phantom. The SAR
exclusion threshold in KDB 447498 D01v06 can be applied to determine SAR test exclusion for adjacent edge
configurations. The closest distance from the antenna to an adjacent tablet edge is used to determine if SAR testing is
required for the adjacent edges, with the adjacent edge positioned against the phantom and the edge containing the
antenna positioned perpendicular to the phantom.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                 Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                     Page 19 of 31                      Form version. : 160427


          FCC SAR Test Report                                                                     Report No. : FA710507-03
12. Conducted RF Output Power (Unit: dBm)
<WLAN Conducted Power>
General Note:
1.  Per KDB 248227 D01v02r02, SAR test reduction is determined according to 802.11 transmission mode
    configurations and certain exposure conditions with multiple test positions. In the 2.4 GHz band, separate SAR
    procedures are applied to DSSS and OFDM configurations to simplify DSSS test requirements. For OFDM, in both
    2.4 and 5 GHz bands, an initial test configuration must be determined for each standalone and aggregated
    frequency band, according to the transmission mode configuration with the highest maximum output power
    specified for production units to perform SAR measurements. If the same highest maximum output power applies to
    different combinations of channel bandwidths, modulations and data rates, additional procedures are applied to
    determine which test configurations require SAR measurement. When applicable, an initial test position may be
    applied to reduce the number of SAR measurements required for next to the ear, UMPC mini-tablet or hotspot mode
    configurations with multiple test positions.
2.  For 2.4 GHz 802.11b DSSS, either the initial test position procedure for multiple exposure test positions or the
    DSSS procedure for fixed exposure position is applied; these are mutually exclusive. For 2.4 GHz and 5 GHz OFDM
    configurations, the initial test configuration is applied to measure SAR using either the initial test position procedure
    for multiple exposure test position configurations or the initial test configuration procedures for fixed exposure test
    conditions. Based on the reported SAR of the measured configurations and maximum output power of the
    transmission mode configurations that are not included in the initial test configuration, the subsequent test
    configuration and initial test position procedures are applied to determine if SAR measurements are required for the
    remaining OFDM transmission configurations. In general, the number of test channels that require SAR
    measurement is minimized based on maximum output power measured for the test sample(s).
3.  For OFDM transmission configurations in the 2.4 GHz and 5 GHz bands, When the same maximum power is
    specified for multiple transmission modes in a frequency band, the largest channel bandwidth, lowest order
    modulation, lowest data rate and lowest order 802.11a/g/n/ac mode is used for SAR measurement, on the highest
    measured output power channel for each frequency band.
4.  DSSS and OFDM configurations are considered separately according to the required SAR procedures. SAR is
    measured in the initial test position using the 802.11 transmission mode configuration required by the DSSS
    procedure or initial test configuration and subsequent test configuration(s) according to the OFDM procedures.18
    The initial test position procedure is described in the following:
    a. When the reported SAR of the initial test position is ≤ 0.4 W/kg, further SAR measurement is not required for
         the other test positions in that exposure configuration and 802.11 transmission mode combinations within the
         frequency band or aggregated band.
    b. When the reported SAR of the test position is > 0.4 W/kg, SAR is repeated for the 802.11 transmission mode
         configuration tested in the initial test position to measure the subsequent next closet/smallest test separation
         distance and maximum coupling test position on the highest maximum output power channel, until the report
         SAR is ≤ 0.8 W/kg or all required test position are tested.
    c. For all positions/configurations, when the reported SAR is > 0.8 W/kg, SAR is measured for these test
         positions/configurations on the subsequent next highest measured output power channel(s) until the reported
         SAR is ≤ 1.2 W/kg or all required channels are tested.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                   Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                       Page 20 of 31                      Form version. : 160427


          FCC SAR Test Report                                                                Report No. : FA710507-03

<2.4GHz WLAN>

                                                        Frequency       Average power    Tune-Up
                         Mode                 Channel                                                    Duty Cycle %
                                                          (MHz)             (dBm)         Limit

                                                1          2412             14.55          15.00
                    802.11b 1Mbps               6          2437             14.67          15.00            100.00
                                                11         2462             14.80          15.00
 2.4GHz WLAN
                                                1          2412             14.38          15.00
                    802.11g 6Mbps               6          2437             14.46          15.00            92.72
                                                11         2462             14.63          15.00
                                                1          2412             13.24          14.00
                  802.11n-HT20 MCS0             6          2437             13.31          14.00            92.86
                                                11         2462             13.52          14.00




<5GHz WLAN>

                                                        Frequency       Average power     Tune-Up
                         Mode                 Channel                                                    Duty Cycle %
                                                          (MHz)             (dBm)          Limit

                                                36         5180             10.93          11.00
                                                40         5200             10.90          11.00
                     802.11a 6Mbps                                                                          92.72
                                                44         5220             10.78          11.00
 5.2GHz WLAN                                    48         5240             10.73          11.00
                                                36         5180             10.41          11.00
                                                40         5200             10.40          11.00
                  802.11n-HT20 MCS0                                                                         92.14
                                                44         5220             10.06          11.00
                                                48         5240             10.01          11.00
                                                38         5190             10.56          11.00
                  802.11n-HT40 MCS0                                                                         86.18
                                                46         5230             10.55          11.00




                                                        Frequency       Average power    Tune-Up
                         Mode                 Channel                                                    Duty Cycle %
                                                          (MHz)             (dBm)         Limit

                                                52         5260             10.83          11.00
                                                56         5280             10.80          11.00
                     802.11a 6Mbps                                                                          92.72
                                                60         5300             10.86          11.00
 5.3GHz WLAN                                    64         5320             10.88          11.00
                                                52         5260             10.36          11.00
                                                56         5280             10.30          11.00
                  802.11n-HT20 MCS0                                                                         92.14
                                                60         5300             10.35          11.00
                                                64         5320             10.39          11.00
                                                54         5270             10.45          11.00
                  802.11n-HT40 MCS0                                                                         86.18
                                                62         5310             10.55          11.00




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                              Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                     Page 21 of 31                   Form version. : 160427


          FCC SAR Test Report                                                                Report No. : FA710507-03


                                                         Frequency      Average power      Tune-Up
                         Mode                 Channel                                                      Duty Cycle %
                                                           (MHz)            (dBm)           Limit

                                               100          5500            11.63            12.00
                                               116          5580            11.33            12.00
                     802.11a 6Mbps             124          5620            11.30            12.00             92.72
                                               132          5660            11.32            12.00
                                               140          5700            11.23            12.00
 5.5GHz WLAN                                   100          5500            10.76            11.50
                                               116          5580            10.43            11.50
                  802.11n-HT20 MCS0            124          5620            10.40            11.50             92.14
                                               132          5660            10.35            11.50
                                               140          5700            10.26            11.50
                                               102          5510            11.12            11.50
                                               110          5550            10.92            11.50
                  802.11n-HT40 MCS0                                                                            86.18
                                               126          5630            10.75            11.50
                                               134          5670            10.60            11.50




                                                         Frequency      Average power      Tune-Up
                         Mode                 Channel                                                      Duty Cycle %
                                                           (MHz)            (dBm)           Limit

                                               149          5745            11.13            11.50
                     802.11a MCS0              157          5785            11.01            11.50             92.72
 5.8GHz WLAN                                   161          5805            10.93            11.50
                                               149          5745            10.76            11.50
                  802.11n-HT20 MCS0            157          5785            10.69            11.50             92.14
                                               161          5805            10.54            11.50
                                               151          5755            11.13            11.50
                  802.11n-HT40 MCS0                                                                            86.18
                                               159          5795            11.05            11.50




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                              Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                     Page 22 of 31                   Form version. : 160427


          FCC SAR Test Report                                                                   Report No. : FA710507-03
13. Bluetooth Exclusions Applied
                                                       Average power(dBm)
      Mode Band
                                         BR/EDR                                    LE

   2.4GHz Bluetooth                           5                                    3
Note:
1. Per KDB 447498 D01v06, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
   distances ≤ 50 mm are determined by:
      [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for
     1-g SAR and ≤ 7.5 for 10-g extremity SAR
              f(GHz) is the RF channel transmit frequency in GHz
              Power and distance are rounded to the nearest mW and mm before calculation
              The result is rounded to one decimal place for comparison
  Bluetooth Max Power (dBm)        Separation Distance (mm)          Frequency (GHz)             exclusion thresholds
              5                                   <5                        2.48                         0.94
Note:
Per KDB 447498 D01v06, when the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to
determine SAR test exclusion. The test exclusion threshold is 0.94 which is <= 3, SAR testing is not required.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                 Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                       Page 23 of 31                    Form version. : 160427


          FCC SAR Test Report                                                      Report No. : FA710507-03
14. Antenna Location
<For Tablet>


                                                      Edge1




                                                                          NFC




 Edge4                                            Display screen                                   Edge2




                                                                                WLAN/BT
                                                                                Antenna




                                                     Edge3                                    Front View
The separation distance for antenna to edge:
                                       To Edge1          To Edge2     To Edge3             To Edge4
           Antenna
                                         (mm)              (mm)         (mm)                 (mm)
     WLAN / BT Antenna                    115               11.5         15                   224




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                  Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                   Page 24 of 31         Form version. : 160427


          FCC SAR Test Report                                                                 Report No. : FA710507-03
<SAR test exclusion table> Tablet
General Note:
1. The below table, when the distance is < 50 mm exclusion threshold is "Ratio", when the distance is > 50 mm exclusion
   threshold is "mW"
2. Maximum power is the source-based time-average power and represents the maximum RF output power among
   production units
3. Per KDB 447498 D01v06, for larger devices, the test separation distance of adjacent edge configuration is determined
   by the closest separation between the antenna and the user.
4. Per KDB 447498 D01v06, standalone SAR test exclusion threshold is applied; If the test separation distance is < 5mm,
   5mm is used to determine SAR exclusion threshold.
5. Per KDB 447498 D01v06, the 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
   distances ≤ 50 mm are determined by:
     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for
     1-g SAR and ≤ 7.5 for 10-g extremity SAR
               f(GHz) is the RF channel transmit frequency in GHz
               Power and distance are rounded to the nearest mW and mm before calculation
               The result is rounded to one decimal place for comparison
6. Per KDB 447498 D01v06, at 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion
   threshold is determined according to the following
     a) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·( f(MHz)/150)] mW, at 100 MHz to 1500 MHz
     b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6 GHz

                           Wireless Interface                                 BT       2.4GHz WLAN        5GHz WLAN
                                     Maximum power (dBm)                       5             15               12
   Exposure Position
                                    Maximum rated power(mW)                   3.0           32.0             16.0
                                     Separation distance(mm)                  5.0           5.0               5.0
      Bottom Face                      exclusion threshold                    0.9           10.0              7.7
                                        Testing required?                     No            Yes               Yes
                                     Separation distance(mm)                 115.0         115.0             115.0
        Edge 1                         exclusion threshold                   745.0         746.0             712.0
                                        Testing required?                     No            No                No
                                     Separation distance(mm)                  11.5          11.5             11.5
        Edge 2                         exclusion threshold                    0.4           4.4               3.4
                                        Testing required?                     No            Yes               Yes
                                     Separation distance(mm)                  15.0          15.0             15.0
        Edge 3                         exclusion threshold                    0.3           3.4               2.6
                                        Testing required?                     No            Yes               No
                                     Separation distance(mm)                 224.0         224.0             224.0
        Edge 4                         exclusion threshold                   1835.0        1836.0           1802.0
                                        Testing required?                     No            No                No




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                               Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                          Page 25 of 31               Form version. : 160427


          FCC SAR Test Report                                                                      Report No. : FA710507-03
15. SAR Test Results
General Note:
1.  Per KDB 447498 D01v06, the reported SAR is the measured SAR value adjusted for maximum tune-up tolerance.
   a. Tune-up scaling Factor = tune-up limit power (mW) / EUT RF power (mW), where tune-up limit is the maximum rated
       power among all production units.
   b. For SAR testing of WLAN signal with non-100% duty cycle, the measured SAR is scaled-up by the duty cycle scaling
       factor which is equal to "1/(duty cycle)"
   c. For WLAN: Reported SAR(W/kg)= Measured SAR(W/kg)* Duty Cycle scaling factor * Tune-up scaling factor
2. Per KDB 447498 D01v06, for each exposure position, testing of other required channels within the operating mode of a
    frequency band is not required when the reported 1-g or 10-g SAR for the mid-band or highest output power channel is:
        ≤ 0.8 W/kg or 2.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≤ 100 MHz
        ≤ 0.6 W/kg or 1.5 W/kg, for 1-g or 10-g respectively, when the transmission band is between 100 MHz and 200 MHz
        ≤ 0.4 W/kg or 1.0 W/kg, for 1-g or 10-g respectively, when the transmission band is ≥ 200 MHz
3. Per KDB 865664 D01v01r04, for each frequency band, repeated SAR measurement is required only when the measured
    SAR is ≥0.8W/kg.



WLAN Note:
1. Per KDB 248227 D01v02r02, for 2.4GHz 802.11g/n SAR testing is not required when the highest reported SAR for DSSS is
   adjusted by the ratio of OFDM to DSSS specified maximum output power and the adjusted SAR is ≤ 1.2 W/kg.
2. Per KDB 248227 D01v02r02, U-NII-1 SAR testing is not required when the U-NII-2A band highest reported SAR for a test
   configuration is ≤ 1.2 W/kg, SAR is not required for U-NII-1 band.
3. When the reported SAR of the test position is > 0.4 W/kg, SAR is repeated for the 802.11 transmission mode configuration
   tested in the initial test position to measure the subsequent next closet/smallest test separation distance and maximum
   coupling test position on the highest maximum output power channel, until the report SAR is ≤ 0.8 W/kg or all required test
   position are tested.
4. For all positions / configurations, when the reported SAR is > 0.8 W/kg, SAR is measured for these test positions /
   configurations on the subsequent next highest measured output power channel(s) until the reported SAR is ≤ 1.2 W/kg or all
   required channels are tested.
5. During SAR testing the WLAN transmission was verified using a spectrum analyzer.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                    Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                        Page 26 of 31                      Form version. : 160427


 seorrow cas. _FCC SAR Test Report                                                    Report No. : FA710507—03
     15.1 Body SAR
     <WLAN SAR>




01 |WLANZ.4GHz       802.11b 1Mbps     |Bottom Face|Omm                    100      1.000
     WLANZ.4GHz      802.11b 1Mbps        Edge 2   |Omm                    100      1.000
     WLANZ.4GHz      802.11b 1Mbps        Edge 3   |Omm                    100      1.000
     WLANSGHz 802.11n—HT40 MCSO |Bottom Face| Omm                         86.18     1.160
02   WLANSGHz 802.11n—HT40 MCSO           Edge 2   |Omm                   86.18     1.160
     WLANSGHz        802.11a 6Mbps     |Bottom Face|Omm                   92.72     1.079
03   WLANSGHz        802.11a 6Mbps        Edge 2   |Omm                   92.72     1.079
     WLANSGHz 802.11n—HT40 MCSO |Bottom Face| Omm                         86.18     1.160
04   WLANSGHz 802.11n—HT40 MCSO           Edge 2   |Omm                   86.18     1.160



            Test Engineer :       Iver Zhang




     SPORTON INTERNATIONAL INC.
     TEL : 886—3—327—3456 / FAX : 886—3—328—4978                                  Issued Date : May. 05, 2017
     FCC ID : QYLAPG234E                                  Page 27 of 31      Form version. : 160427


          FCC SAR Test Report                                                                      Report No. : FA710507-03
16. Uncertainty Assessment
    The component of uncertainly may generally be categorized according to the methods used to evaluate them. The
    evaluation of uncertainly by the statistical analysis of a series of observations is termed a Type An evaluation of
    uncertainty. The evaluation of uncertainty by means other than the statistical analysis of a series of observation is
    termed a Type B evaluation of uncertainty. Each component of uncertainty, however evaluated, is represented by an
    estimated standard deviation, termed standard uncertainty, which is determined by the positive square root of the
    estimated variance.

    A Type A evaluation of standard uncertainty may be based on any valid statistical method for treating data. This
    includes calculating the standard deviation of the mean of a series of independent observations; using the method of
    least squares to fit a curve to the data in order to estimate the parameter of the curve and their standard deviations; or
    carrying out an analysis of variance in order to identify and quantify random effects in certain kinds of measurement.

    A type B evaluation of standard uncertainty is typically based on scientific judgment using all of the relevant
    information available. These may include previous measurement data, experience, and knowledge of the behavior
    and properties of relevant materials and instruments, manufacture’s specification, data provided in calibration reports
    and uncertainties assigned to reference data taken from handbooks. Broadly speaking, the uncertainty is either
    obtained from an outdoor source or obtained from an assumed distribution, such as the normal distribution,
    rectangular or triangular distributions indicated in table below.

       Uncertainty Distributions              Normal             Rectangular           Triangular             U-Shape
                                 (a)                  (b)
           Multi-plying Factor                  1/k                   1/√                  1/√6                 1/√
    (a) standard uncertainty is determined as the product of the multiplying factor and the estimated range of
        variations in the measured quantity
    (b) κ is the coverage factor
                             Table 16.1. Standard Uncertainty for Assumed Distribution

    The combined standard uncertainty of the measurement result represents the estimated standard deviation of the
    result. It is obtained by combining the individual standard uncertainties of both Type A and Type B evaluation using
    the usual “root-sum-squares” (RSS) methods of combining standard deviations by taking the positive square root of
    the estimated variances.

    Expanded uncertainty is a measure of uncertainty that defines an interval about the measurement result within which
    the measured value is confidently believed to lie. It is obtained by multiplying the combined standard uncertainty by a
    coverage factor. Typically, the coverage factor ranges from 2 to 3. Using a coverage factor allows the true value of a
    measured quantity to be specified with a defined probability within the specified uncertainty range. For purpose of this
    document, a coverage factor two is used, which corresponds to confidence interval of about 95 %. The DASY
    uncertainty Budget is shown in the following tables.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                                    Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                         Page 28 of 31                     Form version. : 160427


          FCC SAR Test Report                                                                 Report No. : FA710507-03


                                     Uncertainty                                           Standard         Standard
                                                                           (Ci)   (Ci)
        Error Description              Value       Probability   Divisor                  Uncertainty     Uncertainty
                                                                            1g    10g
                                        (±%)                                               (1g) (±%)       (10g) (±%)
      Measurement System
         Probe Calibration               6.00           N          1        1      1           6.0             6.0
           Axial Isotropy                4.70           R        1.732     0.7    0.7          1.9             1.9
      Hemispherical Isotropy             9.60           R        1.732     0.7    0.7          3.9             3.9
         Boundary Effects                1.00           R        1.732      1      1           0.6             0.6
             Linearity                   4.70           R        1.732      1      1           2.7             2.7
     System Detection Limits             1.00           R        1.732      1      1           0.6             0.6
      Modulation Response                4.68           R        1.732      1      1           2.7             2.7
       Readout Electronics               0.30           N          1        1      1           0.3             0.3
          Response Time                  0.00           R        1.732      1      1           0.0             0.0
         Integration Time                2.60           R        1.732      1      1           1.5             1.5
        RF Ambient Noise                 3.00           R        1.732      1      1           1.7             1.7
     RF Ambient Reflections              3.00           R        1.732      1      1           1.7             1.7
         Probe Positioner                0.40           R        1.732      1      1           0.2             0.2
        Probe Positioning                2.90           R        1.732      1      1           1.7             1.7
          Max. SAR Eval.                 2.00           R        1.732      1      1           1.2             1.2
      Test Sample Related
        Device Positioning               3.03           N          1        1      1           3.0             3.0
          Device Holder                  3.60           N          1        1      1           3.6             3.6
            Power Drift                  5.00           R        1.732      1      1           2.9             2.9
          Power Scaling                  0.00           R        1.732      1      1           0.0             0.0
       Phantom and Setup
       Phantom Uncertainty               6.10           R        1.732      1      1          3.5             3.5
          SAR correction                 0.00           R        1.732      1     0.84        0.0             0.0
Liquid Conductivity Repeatability        0.03           N          1       0.78   0.71        0.0             0.0
   Liquid Conductivity (target)          5.00           R        1.732     0.78   0.71        2.3             2.0
    Liquid Conductivity (mea.)           2.50           R        1.732     0.78   0.71        1.1             1.0
    Temp. unc. - Conductivity            3.68           R        1.732     0.78   0.71        1.7             1.5
 Liquid Permittivity Repeatability       0.02           N          1       0.23   0.26        0.0             0.0
    Liquid Permittivity (target)         5.00           R        1.732     0.23   0.26        0.7             0.8
     Liquid Permittivity (mea.)          2.50           R        1.732     0.23   0.26        0.3             0.4
     Temp. unc. - Permittivity           0.84           R        1.732     0.23   0.26        0.1             0.1
                                 Combined Std. Uncertainty                                   11.6%           11.6%
                                  Coverage Factor for 95 %                                    K=2             K=2
                                 Expanded STD Uncertainty                                    23.2%           23.1%
                      Table 16.2. Uncertainty Budget for frequency range 300 MHz to 3 GHz




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                               Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                     Page 29 of 31                    Form version. : 160427


          FCC SAR Test Report                                                                 Report No. : FA710507-03


                                     Uncertainty                                           Standard         Standard
                                                                           (Ci)   (Ci)
        Error Description              Value       Probability   Divisor                  Uncertainty     Uncertainty
                                                                            1g    10g
                                        (±%)                                               (1g) (±%)       (10g) (±%)
      Measurement System
         Probe Calibration               7.00           N          1        1      1           7.0             7.0
           Axial Isotropy                4.70           R        1.732     0.7    0.7          1.9             1.9
      Hemispherical Isotropy             9.60           R        1.732     0.7    0.7          3.9             3.9
         Boundary Effects                2.00           R        1.732      1      1           1.2             1.2
             Linearity                   4.70           R        1.732      1      1           2.7             2.7
     System Detection Limits             1.00           R        1.732      1      1           0.6             0.6
      Modulation Response                4.68           R        1.732      1      1           2.7             2.7
       Readout Electronics               0.30           N          1        1      1           0.3             0.3
          Response Time                  0.00           R        1.732      1      1           0.0             0.0
         Integration Time                2.60           R        1.732      1      1           1.5             1.5
        RF Ambient Noise                 3.00           R        1.732      1      1           1.7             1.7
     RF Ambient Reflections              3.00           R        1.732      1      1           1.7             1.7
         Probe Positioner                0.40           R        1.732      1      1           0.2             0.2
        Probe Positioning                6.70           R        1.732      1      1           3.9             3.9
          Max. SAR Eval.                 4.00           R        1.732      1      1           2.3             2.3
      Test Sample Related
        Device Positioning               3.03           N          1        1      1           3.0             3.0
          Device Holder                  3.60           N          1        1      1           3.6             3.6
            Power Drift                  5.00           R        1.732      1      1           2.9             2.9
          Power Scaling                  0.00           R        1.732      1      1           0.0             0.0
       Phantom and Setup
       Phantom Uncertainty               6.60           R        1.732      1      1          3.8             3.8
          SAR correction                 0.00           R        1.732      1     0.84        0.0             0.0
Liquid Conductivity Repeatability        0.03           N          1       0.78   0.71        0.0             0.0
   Liquid Conductivity (target)          5.00           R        1.732     0.78   0.71        2.3             2.0
    Liquid Conductivity (mea.)           2.50           R        1.732     0.78   0.71        1.1             1.0
    Temp. unc. - Conductivity            3.68           R        1.732     0.78   0.71        1.7             1.5
 Liquid Permittivity Repeatability       0.02           N          1       0.23   0.26        0.0             0.0
    Liquid Permittivity (target)         5.00           R        1.732     0.23   0.26        0.7             0.8
     Liquid Permittivity (mea.)          2.50           R        1.732     0.23   0.26        0.3             0.4
     Temp. unc. - Permittivity           0.84           R        1.732     0.23   0.26        0.1             0.1
                                 Combined Std. Uncertainty                                   12.9%           12.9%
                                  Coverage Factor for 95 %                                    K=2             K=2
                                 Expanded STD Uncertainty                                    25.9%           25.8%
                       Table 16.3. Uncertainty Budget for frequency range 3 GHz to 6 GHz




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                               Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                     Page 30 of 31                    Form version. : 160427


          FCC SAR Test Report                                                      Report No. : FA710507-03
17. References
       [1]   FCC 47 CFR Part 2 “Frequency Allocations and Radio Treaty Matters; General Rules and
             Regulations”
       [2]   ANSI/IEEE Std. C95.1-1992, “IEEE Standard for Safety Levels with Respect to Human Exposure
             to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz”, September 1992
       [3]   IEEE Std. 1528-2013, “IEEE Recommended Practice for Determining the Peak Spatial-Average
             Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices:
             Measurement Techniques”, Sep 2013
       [4]   SPEAG DASY System Handbook
       [5]   FCC KDB 248227 D01 v02r02, “SAR Guidance for IEEE 802.11 (WiFi) Transmitters”, Oct 2015.
       [6]   FCC KDB 447498 D01 v06, “Mobile and Portable Device RF Exposure Procedures and
             Equipment Authorization Policies”, Oct 2015
       [7]   FCC KDB 616217 D04 v01r02, “SAR Evaluation Considerations for Laptop, Notebook, Netbook
             and Tablet Computers”, Oct 2015
       [8]   FCC KDB 865664 D01 v01r04, "SAR Measurement Requirements for 100 MHz to 6 GHz", Aug
             2015.
       [9]   FCC KDB 865664 D02 v01r02, “RF Exposure Compliance Reporting and Documentation
             Considerations” Oct 2015.




SPORTON INTERNATIONAL INC.
TEL : 886-3-327-3456 / FAX : 886-3-328-4978                                    Issued Date : May. 05, 2017
FCC ID : QYLAP6234E                                Page 31 of 31              Form version. : 160427



Document Created: 2017-10-25 00:20:16
Document Modified: 2017-10-25 00:20:16

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC