RF Exposure Evaluation

FCC ID: QWY-WMI2W167

RF Exposure Info

Download: PDF
FCCID_3934260

                                                TEST REPORT
                                          No.: 18-1-0081001T22a-C1



                                                             According to:
                                                          FCC Regulations
                                                               §1.1310
                                                           § 2.1091 & 2.1093




                                                                   for

                                                    peiker acustic GmbH


                                                Wireless Mobile Interface
                                                    WMI2-W167-M3
                                                   2609-090-554-51

                                          Laboratory Accreditation and Listings



                                                                                   Voluntary Controls for Electromagnetic
                                                      Industry Canada
                                                                                                Emissions
                                                     Reg. No.: 3462D-1
                                                     Reg. No.: 3462D-2                          Reg. No.:
         Accredited EMC-Test Laboratory              Reg. No.: 3462D-3                      R-4452, C-20009,
                                                                                            T-20006, G-20013




                                                                                            MRA US-EU 0003

                                    accredited according to DIN EN ISO/IEC 17025

                                                     CETECOM GmbH
                            Laboratory Radio Communications & Electromagnetic Compatibility
                                        Im Teelbruch 116 • 45219 Essen • Germany
                               Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                             Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                 E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                       Page 1 of 24
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the
written approval of the testing laboratory                                         © Copyright: All rights reserved by CETECOM


Test Report 18-1-0081001T22a-C1, Page 2 of 24


Table of contents
1. Summary of test results                                                                   3
2. Administrative Data                                                                       4
  2.1. Identification of the testing laboratory                                              4
  2.2. Test location                                                                         4
  2.3. Organizational items                                                                  4
  2.4. Applicant’s details                                                                   4
  2.5. Manufacturer’s details                                                                4

3. Equipment under test (EUT)                                                                5
  3.1. TECHNICAL DATA OF MAIN EUT DECLARED BY APPLICANT                                      5
  3.2. EUT: Type, S/N etc. and short descriptions used in this test report                   5
  3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions                       5
  3.4. EUT set-ups                                                                           6
  3.5. EUT operating modes                                                                   6
  3.6. Additional declaration and description of EUT                                         6

4. DESCRIPTION OF TEST SET-UP’s                                                              7
  4.1. Test Set-up for configuration                                                         7
  The RF exposure test is performed in shielded room.                                        7

5. Maximum Permissible RF Exposure                                                           8
  5.1. FCC References & Limits                                                               8
  5.2. E-Field Results                                                                       9
  5.3. H-Field Results                                                                      13

6. Measurement uncertainties                                                                18

7. Accreditation details of CETECOM’s laboratories and test sites                           18

8. Instruments and Ancillary                                                                19
  8.1. Used equipment “CTC”                                                                 19

9. Versions of test reports (change history)                                                24

Table of annex                                                                      Total pages


Annex 1: Measurement diagrams (separate document) TR18_1_0081001T22a_C1_A1                  23
Annex 2: External photographs of EUT (separate document) TR18_1_0081001T22a_C1_A2            5
Annex 3: Test setup photographs (separate document) TR18_1_0081001T22a_C1_A3                 8
The listed attachments are an integral part of this report.




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 3 of 24



1. Summary of test results
The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does not
assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or
samples of the type of the item presented to tests.

The Equipment Under Test (in this report, hereinafter referred as EUT) is a wireless Mobile Interfacee with NFC.
The wireless charger is operated at Frequency 125kHz.



TEST OVERVIEW
  No. of                                                    References, Standards & Limits   EUT
                           Test                                                                      EUT op-              Measured
  Diagram                                         Port                                       set-                                              Result
                           Cases                                  FCC             Limits             mode                  values
  group                                                                                      up
                                                 5cm            §1.1310                                                all values are
                     Electric field                                                                                      below the
       1.1                                    distance to       §2.1091         614 (V/m)     1      1+2+3                                     passed
                       strength                                                                                          regulatory
                                                 EUT            §2.1093                                                     limits
                                                 15cm           §1.1310                                                all values are
                     Electric field                                                                                      below the
       1.1                                    distance to       §2.1091         614 (V/m)     1      1+2+3                                     passed
                       strength                                                                                          regulatory
                                                 EUT            §2.1093                                                     limits
                                                 5cm            §1.1310                                                all values are
                    Magnetic field                                                                                       below the
       1.2                                    distance to       §2.1091         1.63 (A/m)    1      1+2+3                                     passed
                      strength                                                                                           regulatory
                                                 EUT            §2.1093                                                     limits
                                                                                                                       all values are
                                               15/20cm          §1.1310                                                 more than
                    Magnetic field
       1.2                                    distance to       §2.1091         1.63 (A/m)    1      1+2+3              50% below              passed
                      strength                                                                                        the regulatory
                                                 EUT            §2.1093
                                                                                                                            limits
Remark:
Following tests have been performed to show compliance with applicable Standards:
FCC §1.1310, §2.1091 §2.1093
OET Bulletin 65 Supplement C
KDB 680106 D01 V03.

Additional to KDB 680106 D01 V03 tests were performed due to customer declaration with 5cm distance
between edge and top of EUT and probe.

The current version of CETECOM Test Report 18-1-0081001T22a-C1 replaces the Test Report
CETECOM 18-1-00810T22a dated 2018-06-13. The replaced Test Report is herewith invalid




......................................................                                              ....................................................
Dipl.-Ing. Rachid Acharkaoui                                                                                                          W. Markus
Responsible for test section                                                                                  Responsible for test report




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 4 of 24


2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Dipl.-Ing. Rachid Acharkaoui
Deputy:                                                               Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report :                                         W. Markus
Receipt of EUT:                                                       2018-06-08
Date(s) of test:                                                      2018-06-12
Date of report:                                                       2018-07-16
       -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             12.11

2.4. Applicant’s details

Applicant’s name:                                                     peiker acustic GmbH
Address:                                                              Max-Planck-Str. 28-32
                                                                      61381 Friedrichsdorf

                                                                      Germany
Contact person:                                                       Mr. Uwe Hännig

2.5. Manufacturer’s details

Manufacturer’s name:                                                  please see Applicant's details

Address:                                                              please see Applicant's details




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 5 of 24


3. Equipment under test (EUT)
3.1. TECHNICAL DATA OF MAIN EUT DECLARED BY APPLICANT
Main function                   WMI – Wireless Mobile Interface
Type                            W205
Frequency range                 Fixed frequency 125kHz for wireless charging, 13,56MHz for NFC
Max. nominal power              9,25W each Coil
                                PCB antenna
                                - R = 4.0 Ohm
Antenna Type
                                - jZ= 58 Ohm
                                - L = 0.68uH
Power supply                     12V DC
Special EMI components          --
EUT sample type                  Production                         Pre-Production        Engineering
FCC label attached               yes                                no


3.2. EUT: Type, S/N etc. and short descriptions used in this test report

 Short
                                                                    S/N               HW                  SW
 descrip-            EUT                      Type
                                                               serial number     hardware status     software status
 tion*)

               Wireless Mobile         WMI2-W167-M3                                    0000              E005.5
 EUT A                                                        P18001040749
                  Interface            2609-090-554-51                               17/40.01           17/40.01

*) EUT short description is used to simplify the identification of the EUT in this test report.


3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions

    AE
                                                                     S/N              HW                  SW
   short     Auxiliary Equipment               Type
                                                                serial number    hardware status     software status
 descrip-
  tion *)
  AE 1          Main Harness                     --                   --                 --                 --

              VScom USB-CAN
  AE 2                                   USB-CAN Plus            380101643               --                 --
                  Adapter

  AE 3            USB cable                      --                   --                 --                 --

              AVID Qi Receiver
  AE 4                                        102-01              00000337               --                 --
                 Simulator

                                                                                    430 OHM,
  AE 5       OSRAM PointLED              LA P47F-AABA                 --                                    --
                                                                                     550mW
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 6 of 24

3.4. EUT set-ups

 EUT set-up
                         Combination of EUT and AE                                              Remarks
   no.*)

                  EUT A + AE 1 + AE 2 + AE 3 + AE 4 +
    Set. 1                                                                              for wireless charging
                                 AE 5
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.

3.5. EUT operating modes

    EUT
                   Description of
  operating                                                            Additional information
                  operating modes
 mode no.*)

                                                  Wireless charging was activated with special customer SW.
    op. 1        Wireless charging                          The EUT is transferring power to AE4
                                                          With 900mA LOAD (90% charging level)


                                                  Wireless charging was activated with special customer SW.
    op. 2        Wireless charging                          The EUT is transferring power to AE4
                                                           with 500mA LOAD (50%charging level)


                                                  Wireless charging was activated with special customer SW.
    op. 3        Wireless charging                          The EUT is transferring power to AE4
                                                           with 50 mA LOAD (5% charging level)

*) EUT operating mode no. is used to simplify the test report.
   Less than 5% charging level is not possible due to technical reasons with the Qi Receiver Simulator


3.6. Additional declaration and description of EUT
                                                       table-top                      typical use
                                                       floor-standing                  portable use
Set up 1
                                                       wall-mounted                    fixed use
                                                       not defined                     vehicular use
                                                       Residential, commercial and light industry
Place of use                                           Industrial environment
                                                       vehicular use
typical operating cycle of EUT                         < 0,5 sec.  :
Power line:                                           EUT-grounding:
 AC  120V,  230V,  400V                            none
 PE,  N,  L1,  L2  L3                             with power supply
 __ Hz                                                additional:
 DC  12.0V  24V                                    (in case of deviation during tests the single details are described on chapter 4)


Other Ports (description of interconnecting cables)                                                                        connected
                                                          possible total cable length                   shielding          during test
       Description                   Connector
                                               < 3m > 3m                           screened                              yes
1. Main                          Multi pin
                                               : other                              unscreened                            no
Does EUT contain devices susceptible to magnetic fields, e.g. Hall elements, electrodynamics                                yes
microphones, etc.?                                                                                                          no
                                                                                                                            yes
Is mounting position / usual operating position defined?
                                                                                                                            no



CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 7 of 24


4. DESCRIPTION OF TEST SET-UP’s

4.1. Test Set-up for configuration
The RF exposure test is performed in shielded room.

The EUT was placed on a table.

The measurement probe was surrounding point 1 to point 4 at a distance of 5cm and 15cm from the EUT
and 5cm and 20 cm above the top surface (point 5) for H-filed strength

The measurement probe was surrounding point 1 to point 4 at a distance of 5cm and 15cm from the EUT
and 5cm and 15cm above the top surface (point 5) for E-filed strength




                                   RF-
                                  Probe
                                   Field
                                  Probe
                                 be


                                       5 / 15 / 20cm

                5 / 15cm                        5 / 15cm
  be
   Probe
   Field
    RF-




                                                           e
                                                           Probe
                                                           Field
                                                           RF-




                                     EUT
                5 /15 cm                        5 / 15cm




    Schematic: Test set-up for Rf exposure measurements



CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 8 of 24


5. Maximum Permissible RF Exposure

5.1.FCC References & Limits

FCC Rules: §1.1310, § 2.1093

The criteria used for the evaluation of human exposure to radio frequency radiation is listed in table 1 according
FCC §1.1307(b, except in the case of portable devices which shall be evaluated according to the provisions of
§2.1093 of this.

Note 1 to table 1: Occupational/controlled limits apply in situations in which persons are exposed as a consequence
of their employment provide those persons are fully aware for a exposure and can control over their exposure.
Limits for occupational/controlled exposures also apply in situations when an individual is transient through a
location where occupational/controlled apply provided he or she is made aware of the potential for exposure.

Note 2 to table 1: General population/uncontrolled exposures apply in situations in which the general public may
be exposed, or which persons that are exposed as a consequence of their employment may not be fully aware of
the potential for exposure or cannot exercise control over their exposure.




So applicable limits in this case are as follows:

§1.1310 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
Table 1(B) Limits for General Population/Uncontrolled Exposure

0.3–1,34 MHz: Electric field: 614 V/m

0.3–1,34 MHz: Magnetic field: 1.63 A/m




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 9 of 24

5.2. E-Field Results
5.2.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
test location    CETECOM Essen (Chapter 2.2.1)           Please see Chapter 2.2.2           Please see Chapter 2.2.3
 equipment       686 EHP-200A                                                                              
 signaling       017 CMD 65    323 CMD 55               340 CMD 55
 signaling       298 CMU       460 CMU                  295 RACAL         392 MT8820A
line voltage     12V DC

5.2.2. Test condition and test set-up
link to test system (if used):                  air link  cable connection
 EUT-grounding (if different to chapter 3.5)    none  with power supply  additional connection
Equipment set up                               -                             -
Climatic conditions                            Temperature: 24 °C            Rel. humidity: 31 %

5.2.3. Results

Table 1:
The aggregate E-Field strenghts at 15cm surrounding the device:
 EUT Type and S/N or EUT set-up no.                                                         Set- up 1
 EUT operating mode or
                                                                        EUT operating mode 1 (90% charging level)
      operating mode no.
  Frequency              Distance between                                E-field                                E-field
                Position
    Range                 EUT and Field                                  (V/m)                                  Limit
                               probe                                                                            (V/m)
    (kHz)
                                (m)
     125           1            0.15                                      0,84                                    614
     125           2            0.15                                      1,21                                    614
     125           3            0.15                                       1,0                                    614
     125           4            0.15                                      0,86                                    614
Remarks:

 EUT Type and S/N or EUT set-up no.                                                         Set- up 1
 EUT operating mode or
                                                                        EUT operating mode 2 (50% charging level)
      operating mode no.
  Frequency              Distance between                                E-field                                E-field
                Position
    Range                 EUT and Field                                  (V/m)                                  Limit
                               probe                                                                            (V/m)
    (kHz)
                                (m)
     125           1            0.15                                      0,54                                    614
     125           2            0.15                                      0,89                                    614
     125           3            0.15                                      0,65                                    614
     125           4            0.15                                      0,59                                    614
Remarks:

 EUT Type and S/N or EUT set-up no.                                                         Set- up 1
 EUT operating mode or
                                                                        EUT operating mode 3 (5% charging level)
      operating mode no.
  Frequency              Distance between                                E-field                                E-field
                Position
    Range                 EUT and Field                                  (V/m)                                  Limit
                               probe                                                                            (V/m)
    (kHz)
                                (m)
     125           1            0.15                                      0,43                                    614
     125           2            0.15                                      0,42                                    614
     125           3            0.15                                      0,33                                    614
     125           4            0.15                                      0,35                                    614
Remarks:

CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 10 of 24



Table 2:
The aggregate E-Field strenghts at 15cm above the top of the device:
 EUT Type and S/N or EUT set-up no.                              Set- up 1
 EUT operating mode or
                                                 EUT operating mode 1 (5% charging level)
      operating mode no.
  Frequency              Distance between         E-field                        E-field
                Position
    Range                 EUT and Field           (V/m)                          Limit
                               probe                                             (V/m)
    (kHz)
                                (m)
     125           5            0.15               6,94                           614
Remarks:

 EUT Type and S/N or EUT set-up no.                              Set- up 1
 EUT operating mode or
                                                 EUT operating mode 2 (50% charging level)
      operating mode no.
  Frequency              Distance between         E-field                        E-field
                Position
    Range                 EUT and Field           (V/m)                          Limit
                               probe                                             (V/m)
    (kHz)
                                (m)
     125           5            0.15               4,57                           614
Remarks:

 EUT Type and S/N or EUT set-up no.                              Set- up 1
 EUT operating mode or
                                                 EUT operating mode 3 (90% charging level)
      operating mode no.
  Frequency              Distance between         E-field                        E-field
                Position
    Range                 EUT and Field           (V/m)                          Limit
                               probe                                             (V/m)
    (kHz)
                                (m)
     125           5            0.15               1,33                           614
Remarks:




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 11 of 24



Table 3:
The aggregate E-Field strenghts at 5cm surrounding the device:
 EUT Type and S/N or EUT set-up no.                              Set- up 1
 EUT operating mode or
                                                 EUT operating mode 1 (90% charging level)
      operating mode no.
  Frequency              Distance between         E-field                        E-field
                Position
    Range                 EUT and Field           (V/m)                          Limit
                               probe                                             (V/m)
    (kHz)
                                (m)
     125           1            0.05               1,87                           614
     125           2            0.05               2,51                           614
     125           3            0.05               1,99                           614
     125           4            0.05               1,69                           614
Remarks:

 EUT Type and S/N or EUT set-up no.                              Set- up 1
 EUT operating mode or
                                                 EUT operating mode 2 (50% charging level)
      operating mode no.
  Frequency              Distance between         E-field                        E-field
                Position
    Range                 EUT and Field           (V/m)                          Limit
                               probe                                             (V/m)
    (kHz)
                                (m)
     125           1            0.05                1,4                           614
     125           2            0.05               1,82                           614
     125           3            0.05               1,11                           614
     125           4            0.05               1,19                           614
Remarks:


 EUT Type and S/N or EUT set-up no.                              Set- up 1
 EUT operating mode or
                                                 EUT operating mode 3 (5% charging level)
      operating mode no.
  Frequency              Distance between         E-field                        E-field
                Position
    Range                 EUT and Field           (V/m)                          Limit
                               probe                                             (V/m)
    (kHz)
                                (m)
     125           1            0.05               1,05                           614
     125           2            0.05               1,07                           614
     125           3            0.05               0,53                           614
     125           4            0.05               0,70                           614
Remarks:




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 12 of 24



Table 4:
The aggregate E-Field strenghts at 5cm above the top of the device:
 EUT Type and S/N or EUT set-up no.                             Set- up 1
 EUT operating mode or
                                                 EUT operating mode 1 (5% charging level)
      operating mode no.
  Frequency              Distance between        E-field                        E-field
                Position
    Range                 EUT and Field          (V/m)                          Limit
                               probe                                            (V/m)
    (kHz)
                                (m)
     125           5            0.05              12,5                            614
Remarks:

 EUT Type and S/N or EUT set-up no.                             Set- up 1
 EUT operating mode or
                                                 EUT operating mode 1 (5% charging level)
      operating mode no.
  Frequency              Distance between        E-field                        E-field
                Position
    Range                 EUT and Field          (V/m)                          Limit
                               probe                                            (V/m)
    (kHz)
                                (m)
     125           5            0.05              8,76                            614
Remarks:

 EUT Type and S/N or EUT set-up no.                             Set- up 1
 EUT operating mode or
                                                 EUT operating mode 1 (5% charging level)
      operating mode no.
  Frequency              Distance between        E-field                        E-field
                Position
    Range                 EUT and Field          (V/m)                          Limit
                               probe                                            (V/m)
    (kHz)
                                (m)
     125           5            0.05              3,93                            614
Remarks:




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 13 of 24



5.3. H-Field Results
5.3.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
test location     CETECOM Essen (Chapter 2.2.1)          Please see Chapter 2.2.2          Please see Chapter 2.2.3
 equipment        686 EHP-200A                                                                            
 signaling        017 CMD 65    323 CMD 55              340 CMD 55
 signaling        298 CMU       460 CMU                 295 RACAL         392 MT8820A
line voltage      12V DC

5.3.2. Test condition and test set-up

link to test system (if used):                  air link  cable connection
 EUT-grounding (if different to chapter 3.5)    none  with power supply  additional connection
Equipment set up                               -                             -
Climatic conditions                            Temperature: 24 °C            Rel. humidity: 31 %



Table 5:
The aggregate H-Field strenghts at 15cm surrounding the device:
EUT Type and S/N or              EUT set-
                                                                                      Set-up 1
up no.
EUT operating mode or
                                                                  EUT operating mode 1 (90% charging level)
       operating mode no.
Frequency                         Distance
  Range                           between
                                                                            H-field                 H-field
               Position           EUT and              H-field
                                                                            Limit                Limit – 50%             Result
                                   Field               (A/m)
    (kHz)                                                                   (A/m)                  (A/m) 1)
                                   probe
                                    (m)
     125               1            0.15                 0,21                 1.63                   0,815               passed
   125           2         0.15         0,25                                  1.63                   0,815               passed
   125           3         0.15         0,16                                  1.63                   0,815               passed
   125           4         0.15         0,16                                  1.63                   0,815               passed
   125           5         0.15         0,45                                  1.63                     --                passed
Remarks: 1) according KDB 680106 D01 V03


EUT Type and S/N or              EUT set-
                                                                                      Set-up 1
up no.
EUT operating mode or
                                                                  EUT operating mode 2 (50% charging level)
       operating mode no.
Frequency                       Distance
  Range                         between
                                                                            H-field                 H-field
               Position         EUT and       H-field
                                                                            Limit                Limit – 50%             Result
                                 Field        (A/m)
    (kHz)                                                                   (A/m)                  (A/m) 1)
                                 probe
                                  (m)
   125                  1         0.15         0,17                           1.63                   0,815               passed
   125                  2         0.15         0,16                           1.63                   0,815               passed
   125                  3         0.15         0,10                           1.63                   0,815               passed
   125                  4         0.15         0,11                           1.63                   0,815               passed
   125                  5         0.15         0,65                           1.63                     --                passed
Remarks:        1) according KDB 680106 D01 V03



CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 14 of 24



EUT Type and S/N or         EUT set-
                                                                       Set-up 1
up no.
EUT operating mode or
                                                     EUT operating mode 3 (5% charging level)
       operating mode no.
Frequency                   Distance
  Range                     between
                                                             H-field                 H-field
               Position     EUT and        H-field
                                                             Limit                Limit – 50%   Result
                             Field         (A/m)
   (kHz)                                                     (A/m)                  (A/m) 1)
                             probe
                              (m)
    125           1           0.15          0,12              1.63                   0,815      passed
   125           2         0.15         0,11                  1.63                   0,815      passed
   125           3         0.15         0,06                  1.63                   0,815      passed
   125           4         0.15         0,09                  1.63                   0,815      passed
   125           5         0.15         0,95                  1.63                     --       passed
Remarks: 1) according KDB 680106 D01 V03




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 15 of 24



Table 6:
The aggregate H-Field strenghts at 20cm above the top of the device:
EUT Type and S/N or         EUT set-
                                                                    Set-up 1
up no.
EUT operating mode or
                                                 EUT operating mode 1 (90% charging level)
       operating mode no.
Frequency               Distance
  Range                 between
                                                          H-field                 H-field
               Position EUT and       H-field
                                                          Limit                Limit – 50%   Result
                         Field        (A/m)
   (kHz)                                                  (A/m)                  (A/m) 1)
                         probe
                          (m)
    125         5         0.2          0,54                1.63                   0,815      passed
         1
Remarks: ) according KDB 680106 D01 V03


EUT Type and S/N or         EUT set-
                                                                    Set-up 1
up no.
EUT operating mode or
                                                 EUT operating mode 2 (50% charging level)
       operating mode no.
Frequency                Distance
  Range                  between
                                                          H-field                 H-field
               Position  EUT and       H-field
                                                          Limit                Limit – 50%   Result
                          Field        (A/m)
   (kHz)                                                  (A/m)                  (A/m) 1)
                          probe
                           (m)
    125          5         0.2          0,43               1.63                   0,815      passed
Remarks: 1) according KDB 680106 D01 V03


EUT Type and S/N or         EUT set-
                                                                    Set-up 1
up no.
EUT operating mode or
                                                 EUT operating mode 3 (5% charging level)
       operating mode no.
Frequency                Distance
  Range                  between
                                                          H-field                 H-field
               Position  EUT and       H-field
                                                          Limit                Limit – 50%   Result
                          Field        (A/m)
   (kHz)                                                  (A/m)                  (A/m) 1)
                          probe
                           (m)
    125          5         0.2          0,29               1.63                   0,815      passed
Remarks: 1) according KDB 680106 D01 V03




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 16 of 24



Table 7:
The aggregate H-Field strenghts at 5cm surrounding the device:
EUT Type and S/N or         EUT set-
                                                                        Set-up 1
up no.
EUT operating mode or
                                                     EUT operating mode 1 (90% charging level)
       operating mode no.
Frequency                  Distance
  Range                    between
                                                              H-field                 H-field
               Position    EUT and       H-field
                                                              Limit                Limit – 50%   Result
                            Field        (A/m)
   (kHz)                                                      (A/m)                  (A/m) 1)
                            probe
                             (m)
   125             1         0.05         0,36                 1.63                   0,815      passed
   125             2         0.05         0,40                 1.63                   0,815      passed
   125             3         0.05         0,25                 1.63                   0,815      passed
   125             4         0.05         0,25                 1.63                   0,815      passed
Remarks:   1) according KDB 680106 D01 V03




EUT Type and S/N or         EUT set-
                                                                        Set-up 1
up no.
EUT operating mode or
                                                     EUT operating mode 2 (50% charging level)
       operating mode no.
Frequency                  Distance
  Range                    between
                                                              H-field                 H-field
               Position    EUT and       H-field
                                                              Limit                Limit – 50%   Result
                            Field        (A/m)
   (kHz)                                                      (A/m)                  (A/m) 1)
                            probe
                             (m)
   125             1         0.05         0,17                 1.63                   0,815      passed
   125             2         0.05         0,21                 1.63                   0,815      passed
   125             3         0.05         0,24                 1.63                   0,815      passed
   125             4         0.05         0,25                 1.63                   0,815      passed
Remarks:   1) according KDB 680106 D01 V03



EUT Type and S/N or         EUT set-
                                                                        Set-up 1
up no.
EUT operating mode or
                                                     EUT operating mode 3 (5% charging level)
       operating mode no.
Frequency                   Distance
  Range                     between
                                                              H-field                 H-field
               Position     EUT and        H-field
                                                              Limit                Limit – 50%   Result
                             Field         (A/m)
   (kHz)                                                      (A/m)                  (A/m) 1)
                             probe
                              (m)
    125           1           0.05          0,15               1.63                   0,815      passed
   125           2         0.05         0,17                   1.63                   0,815      passed
   125           3         0.05         0,18                   1.63                   0,815      passed
   125           4         0.05         0,21                   1.63                   0,815      passed
Remarks: 1) according KDB 680106 D01 V03


CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 17 of 24



Table 8:
The aggregate H-Field strenghts at 5cm above the top of the device:
EUT Type and S/N or         EUT set-
                                                                    Set-up 1
up no.
EUT operating mode or
                                                 EUT operating mode 1 (90% charging level)
       operating mode no.
Frequency               Distance
  Range                 between
                                                          H-field                 H-field
               Position EUT and       H-field
                                                          Limit                Limit – 50%   Result
                         Field        (A/m)
   (kHz)                                                  (A/m)                  (A/m) 1)
                         probe
                          (m)
    125         5         0.05         1,30                1.63                   0,815      passed
         1
Remarks: ) according KDB 680106 D01 V03


EUT Type and S/N or         EUT set-
                                                                    Set-up 1
up no.
EUT operating mode or
                                                 EUT operating mode 2 (50% charging level)
       operating mode no.
Frequency                Distance
  Range                  between
                                                          H-field                 H-field
               Position  EUT and       H-field
                                                          Limit                Limit – 50%   Result
                          Field        (A/m)
   (kHz)                                                  (A/m)                  (A/m) 1)
                          probe
                           (m)
    125          5         0.05         0,43               1.63                   0,815      passed
Remarks: 1) according KDB 680106 D01 V03


EUT Type and S/N or         EUT set-
                                                                    Set-up 1
up no.
EUT operating mode or
                                                 EUT operating mode 3 (5% charging level)
       operating mode no.
Frequency                Distance
  Range                  between
                                                          H-field                 H-field
               Position  EUT and       H-field
                                                          Limit                Limit – 50%   Result
                          Field        (A/m)
   (kHz)                                                  (A/m)                  (A/m) 1)
                          probe
                           (m)
    125          5         0.05         0,29               1.63                   0,815      passed
Remarks: 1) according KDB 680106 D01 V03




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 18 of 24


6. Measurement uncertainties

The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate
coverage factor k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account and
it’s contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                  Calculated uncertainty based
            RF-Measurement                  Frequency range                                                Remarks:
                                                                  on a confidence level of 95%
 Power Output conducted                     9 kHz .. 20 GHz                   1.0 dB                            --
 Power Output radiated                      30 MHz .. 4 GHz                  3.17 dB                  Substitution method
 Conducted emissions on antenna ports       9 kHz .. 20 GHz                   1.0 dB                            --
                                            9 kHz .. 30 MHz                   5.0 dB                     Magnetic field
                                             9 MHz .. 1 GHz                   5.0 dB                        E-Field
 Radiated emissions enclosure
                                            30 MHz .. 1 GHz                   4.2 dB                        E-Field
                                            1 GHz .. 20 GHz                  3.17 dB                  Substitution method
                                             9 kHz .. 4 GHz         0.1272 ppm (Delta Marker )          Frequency error
 Occupied bandwidth
                                                                               1.0 dB                       Power
                                             9 kHz .. 4 GHz          0.1272 ppm (Delta Marker)          Frequency error
 Emission bandwidth
                                                                               1.0 dB                       Power
 Frequency stability                        9 kHz .. 20 GHz                 0.0636 ppm                        --
 Conducted emissions                        9 kHz .. 150 kHz                   4.0 dB                         --
 on AC-mains port (UCISPR)                 150 kHz .. 30 MHz                   3.6 dB

Table: measurement uncertainties, valid for conducted/radiated measurements




7. Accreditation details of CETECOM’s laboratories and test sites

 Ref.-   Accreditation                  Valid for laboratory area or test site
 No.      Certificate                                                                             Accreditation Body
 -          D-PL-                                                                            DAkkS, Deutsche
                         All laboratories and test sites of CETECOM GmbH, Essen
         12047-01-01                                                                         Akkreditierungsstelle GmbH
 337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                             FCC, Federal Communications
 487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
      MRA US-EU                                                                              Commission
 558                 Radiated Measurements above 1 GHz, 3 m (FAR)
          0003                                                                               Laboratory Division, USA
 348                 Mains Ports Conducted Interference Measurements
                                                                                             (MRA US-EU 0003)
 348                 Telecommunication Ports Conducted Interference Measurem.
 337    3462D-1      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                             IC, Industry Canada
 487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                             Certification and Engineering
 550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                             Bureau
 558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
 337    R-20013      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                        VCCI, Voluntary Control
 487    G-20013      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)                         Council for Interference by
 550    C-20009      Mains Ports Conducted Interference Measurements                         Information Technology
 348     T-20006     Telecommunication Ports Conducted Interference Measurem.                Equipment, Japan
 OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 19 of 24


8. Instruments and Ancillary
8.1. Used equipment “CTC”
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory
equipment.


8.1.1. Test software and firmware of equipment
  Ref.-No.




                            Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001          EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012          Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013          Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017          Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
053          Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
119          RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
140          Signal Generator                          SMHU                     831314/006          Firm.= 3.21
261          Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262          Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263          Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
264          Spectrum Analyzer                         FSEK 30                  826939/005          Bios=2.1, Analyzer= 3.20
                                                                                                    UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295          Racal Digital Radio Test Set              6103                     1572
                                                                                                    SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                    R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298          Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                    all band used
323          Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
331          Climatic Test Chamber -40/+80 Grad        HC 4055                  43146               TSI 1.53
335          CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340          Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
355          Power Meter                               URV 5                    891310/027          Firm.= 1.31
365          10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
366          Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371          Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377          EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378          Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
389          Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                    Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392          Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                    4.52#002
                                                                                                    R&S Test Firmware Base=5.14, Mess-Software=
436          Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                    GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441          CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442          CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                       System CTC-FAR-EMI-
443          CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 9.15.00
                                                       RSE
444          CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 9.15.00
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
460          Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489          EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491          ESD Simulator dito                        ESD dito                 dito307022          V 2.30
524          Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
526          Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
527          Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
528          Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
546          Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                    R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547          Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                    f. all band used, GSM = 5.14 WCDMA: = 5.14
584          Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                    R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597          Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                    not installed, Mainboard= µP1=V.850
598          Spectrum Analyzer                         FSEM 30 (Reserve)        831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
620          EMI Test Receiver                         ESU 26                   100362              4.43_SP3
642          Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
                                                                                                    CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692          Bluetooth Tester                          CBT 32                   100236
                                                                                                    RF)




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 20 of 24



8.1.2. Single instruments and test systems
 Ref.-No.




                           Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001         EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012         Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013         Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017         Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
053         Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
119         RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
140         Signal Generator                          SMHU                     831314/006          Firm.= 3.21
261         Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262         Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263         Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
264         Spectrum Analyzer                         FSEK 30                  826939/005          Bios=2.1, Analyzer= 3.20
                                                                                                   UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295         Racal Digital Radio Test Set              6103                     1572
                                                                                                   SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                   R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298         Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                   all band used
323         Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
331         Climatic Test Chamber -40/+80 Grad        HC 4055                  43146               TSI 1.53
335         CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340         Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
355         Power Meter                               URV 5                    891310/027          Firm.= 1.31
365         10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
366         Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371         Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377         EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378         Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
383         Signal Generator                          SME 03                   842 828 /034        Firm.= 4.61
389         Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                   Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392         Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                   4.52#002
                                                                                                   R&S Test Firmware Base=5.14, Mess-Software=
436         Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                   GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441         CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442         CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                      System CTC-FAR-EMI-
443         CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 8.53
                                                      RSE
444         CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 8.40
                                                                                                   R&S Test Firmware Base=5.14, GSM=5.14
460         Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                   WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489         EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491         ESD Simulator dito                        ESD dito                 dito307022          V 2.30
524         Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
526         Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
527         Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
528         Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                   R&S Test Firmware Base=5.14, GSM=5.14
546         Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                   WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                   R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547         Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                   f. all band used, GSM = 5.14 WCDMA: = 5.14
584         Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                   R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597         Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                   not installed, Mainboard= µP1=V.850
598         Spectrum Analyzer                         FSEM 30 (Reserve)        831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
620         EMI Test Receiver                         ESU 26                   100362              4.43_SP3
642         Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
                                                                                                   CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692         Bluetooth Tester                          CBT 32                   100236
                                                                                                   RF)




CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 21 of 24



8.1.3. Single instruments and test systems
 Ref.-No.




                                                                                                                       calibration
                                                                                                                       Interval of



                                                                                                                                         Remark
                           Equipment                              Type            Serial-No.        Manufacturer                                      Cal
                                                                                                                                                      due

001         EMI Test Receiver                         ESS                      825132/017      Rohde & Schwarz         12 M          -            16.05.2019
005         AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                  861741/005      Rohde & Schwarz         12 M          -            16.05.2019
007         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                  892563/002      Rohde & Schwarz         12 M          -            16.05.2019
009         Power Meter (EMS-radiated)                NRV                      863056/017      Rohde & Schwarz         24 M          -            15.05.2019
011         Insertion Unit (EMS-radiated)             URV5-Z2                  864169/004      Rohde & Schwarz         24 M          -
012         Signal Generator (EMS-cond.)              SMY 01                   839069/027      Rohde & Schwarz         24 M          -            15.05.2019
013         Power Meter (EMS cond.)                   NRVD                     839111/003      Rohde & Schwarz         24 M          -            15.05.2019
014         Insertion Unit (EMS cond.)                URV5-Z2                  838519/029      Rohde & Schwarz         24 M          -            15.05.2019
015         Insertion Unit (EMS cond.)                URV5-Z4                  838570/024      Rohde & Schwarz         24 M          -            15.05.2019
016         Line Impedance Simulating Network         Op. 24-D                 B6366           Spitzenberger+Spies     36 M          -            30.05.2019
017         Digital Radiocommunication Tester         CMD 60 M                 844365/014      Rohde & Schwarz         pre-m         3
021         Loop Antenna (H-Field)                    6502                     9206-2770       EMCO                    36 M          -            30.05.2021
031         Absorbing Clamp                           MDS-21                   863325/015      Rohde & Schwarz         36 M          -            30.05.2021
033         RF-current probe (100kHz-30MHz)           ESH2-Z1                  879581/18       Rohde & Schwarz         24 M          -            15.05.2019
049         Current Clamp (injection)                 F-120-2                  48              FCC                     24 M          -            30.05.2020
050         3-ph Coupling Decoupling Netw. (Burst)    CDN 300                  176             Schaffner               36 M          -            30.05.2021
051         VHF-Current Probe 20-300 MHz              ESV-Z1                   872421          Rohde & Schwarz         36 M          -            30.05.2021
052         Notch Filter DECT                         WRCB 1887,82/1889,55SS   12              Wainwright Industries   pre-m         2
057         relay-switch-unit (EMS system)            RSU                      494440/002      Rohde & Schwarz         pre-m         1a
058         capacitive clamp (Burst)                  IP 4                     99              Haefely                 36 M          -            30.05.2021
060         power amplifier (DC-2kHz)                 PAS 5000                 B6363           Spitzenberger+Spies     -             3
067         coupling decoupling-network               CDN 801-M2/M3            272             Lüthi                   36 M          -            15.05.2020
068         coupling decoupling-network               CDN 801-M5               95226           Lüthi                   36 M          -            17.05.2020
069         EM - clamp                                EM101                    9535159         Lüthi                   36 M          -            30.05.2019
072         coupling decoupling-network               CDN 801-M2/M3            276             Lüthi                   36 M          -            17.05.2020
083         AC - power supply, 0-10 A                 EAC/MT 27010             910502096       EURO TEST               pre-m         2
084         AC - power supply, 0-5 A                  ELABO-8-34214            -               ELABO                   pre-m         2
085         AC - power supply, 0-10 A                 R250                     -               Schunterm.&Benningh.    pre-m         2
086         DC - power supply, 0 -10 A                LNG 50-10                -               Heinzinger Electronic   pre-m         2
087         DC - power supply, 0 -5 A                 EA-3013 S                -               Elektro Automatik       pre-m         2
091         USB-LWL-Converter                         OLS-1                    007/2006        Ing. Büro Scheiba       -             4
094         artificial head (No.1)                    4905                     1566990         Brüel & Kjaer           pre-m         2
099         passive voltage probe                     ESH2-Z3                  299.7810.52     Rohde & Schwarz         36 M          -            30.05.2021
100         passive voltage probe                     Probe TK 9416            without         Schwarzbeck             36 M          -            30.05.2021
110         USB-LWL-Converter                         OLS-1                    -               Ing. Büro Scheiba       -             4
119         RT Harmonics Analyzer dig. Flickermeter   B10                      G60547          BOCONSULT               36 M          -            30.05.2019
131         RF-Current Probe                          F-52                     19              FCC                     36 M          -            17.05.2020
133         horn antenna 18 GHz (Meas 1)              3115                     9012-3629       EMCO                    36 M          1c           10.03.2020
134         horn antenna 18 GHz (Subst 2)             3115                     9005-3414       EMCO                    36 M          -            10.03.2020
248         attenuator                                SMA 6dB 2W               -               Radiall                 pre-m         2
249         attenuator                                SMA 10dB 10W             -               Radiall                 pre-m         2
252         attenuator                                N 6dB 12W                -               Radiall                 pre-m         2
256         attenuator                                SMA 3dB 2W               -               Radiall                 pre-m         2
257         hybrid                                    4031C                    04491           Narda                   pre-m         2
260         hybrid coupler                            4032C                    11342           Narda                   pre-m         2
261         Thermal Power Sensor                      NRV-Z55                  825083/0008     Rohde & Schwarz         24 M          -            30.05.2020
262         Power Meter                               NRV-S                    825770/0010     Rohde & Schwarz         24 M          -            30.05.2019
263         Signal Generator                          SMP 04                   826190/0007     Rohde & Schwarz         36 M          -            30.05.2019
265         peak power sensor                         NRV-Z33, Model 04        840414/009      Rohde & Schwarz         24 M          -            30.05.2020
266         Peak Power Sensor                         NRV-Z31, Model 04        843383/016      Rohde & Schwarz         24 M          -            30.05.2020
267         notch filter GSM 850                      WRCA 800/960-6EEK        9               Wainwright GmbH         pre-m         2
268         AC/DC power supply                        EA 3050-A                9823636         Elektro Automatik       pre-m         -
270         termination                               1418 N                   BB6935          Weinschel               pre-m         2
271         termination                               1418 N                   BE6384          Weinschel               pre-m         2
272         attenuator (20 dB) 50 W                   Model 47                 BF6239          Weinschel               pre-m         2
273         attenuator (10 dB) 100 W                  Model 48                 BF9229          Weinschel               pre-m         2
274         attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W    BG0321          Weinschel               pre-m         2
275         DC-Block                                  Model 7003 (N)           C5129           Weinschel               pre-m         2
276         DC-Block                                  Model 7006 (SMA)         C7061           Weinschel               pre-m         2
279         power divider                             1515 (SMA)               LH855           Weinschel               pre-m         2
284         coupling decoupling network               CDN 801-M1               1661            Lüthi                   36 M          -            17.05.2020
285         coupling decoupling network               CDN 801-S1               1642            Lüthi                   36 M          -            17.05.2020
295         Racal Digital Radio Test Set              6103                     1572            Racal                   pre-m         3
                                                                               R=316568/004
296         audio measurement amplifier               2636C (Reserve)                          Brüel & Kjaer           pre-m         2
                                                                               B=1537541
298         Univ. Radio Communication Tester          CMU 200                  832221/091      Rohde & Schwarz         pre-m         3
299         audio microphone                          134                      -               Brüel & Kjaer           pre-m         2
300         AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                  892 239/020     Rohde & Schwarz         12 M          -            17.05.2019
301         attenuator (20 dB) 50W, 18GHz             47-20-33                 AW0272          Lucas Weinschel         pre-m         2

CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 22 of 24
 Ref.-No.




                                                                                                                            calibration
                                                                                                                            Interval of



                                                                                                                                              Remark
                           Equipment                              Type                Serial-No.         Manufacturer                                      Cal
                                                                                                                                                           due

302         horn antenna 40 GHz (Meas 1)             BBHA9170                     155               Schwarzbeck             36 M          -            14.03.2020
303         horn antenna 40 GHz (Subst 1)            BBHA9170                     156               Schwarzbeck             36 M          -            20.03.2020
304         fix dipole antenna 1,6 GHz               EMCO 3125-307                9907-1001         ETS                     pre-m         -
305         fix dipole antenna 1,8-2,0 GHz           EMCO 3125-306                9907-1001         ETS                     pre-m         -
306         fix dipole antenna 2,45 GHz              EMCO 3125-308                9907-1001         ETS                     pre-m         -
307         fix dipole antenna 3 GHz                 EMCO 3125-309                9907-1001         ETS                     pre-m         -
317         1000 Hz calibrator 94 dB SPL             4230 94dB                    1542286           Brüel & Kjaer           12 M          -
323         Digital Radiocommunication Tester        CMD 55                       825878/0034       Rohde & Schwarz         pre-m         3
337         System CTC OATS NSA                      System EMI OATS NSA          -                 HD GmbH                 24 M          5            12.04.2019
340         Digital Radiocommunication Tester        CMD 55                       849709/037        Rohde & Schwarz         pre-m         3
341         Digital Multimeter                       Fluke 112                    81650455          Fluke                   24 M          -            30.05.2020
342         Digital Multimeter                       Voltcraft M-4660A            IB 255466         Voltcraft               24 M          -            17.05.2019
344         adaptor 150/50 Ohm                       150/50                       -                 Krohne                  36 M          -            17.05.2020
345         adaptor 150/50 Ohm                       150/50                       -                 Krohne                  36 M          -            17.05.2020
347         laboratory site                          radio lab.                   -                 -                       -             5
348         laboratory site                          EMI conducted                -                 -                       -             5
349         car battery 12 V                         car battery 12 V             without           -                       -             3
350         car battery 12 V                         car battery 12 V             without           -                       -             3
354         DC - Power Supply 40A                    NGPE 40/40                   448               Rohde & Schwarz         pre-m         2
357         power sensor                             NRV-Z1                       861761/002        Rohde & Schwarz         24 M          -            24.05.2019
363         Kalibrieradapter HF-uns.                 CR 100 A                     without           Lüthi                   24 M          -            30.05.2020
364         Kalibrieradapter HF-uns.                 CR 100 A                     128               Lüthi                   24 M          -            30.05.2020
366         Ultra Compact Simulator                  UCS 500 M4                   V0531100594       EM-Test                 12 M          -            30.05.2019
368         ROD-Antenna                              HFH 2-Z1                     879283/31         Rohde & Schwarz         60 M          -            17.07.2019
371         Bluetooth Tester                         CBT32                        100153            R&S                     36 M          -            30.05.2019
373         Single-Line V-Network (50 Ohm/5µH)       ESH3-Z6                      100535            Rohde & Schwarz         12 M          -            17.05.2019
374         Power Amplifier 0,8-3 GHz                60S1G3                       306528            Amplifier Research      12 M          1a           20.03.2018
375         Directional Coupler                      DC7144M1                     306498            Amplifier Research      12 M          1a           20.03.2018
376         Horn Antenna 6 GHz                       BBHA9120 E                   BBHA 9120 E 179   Schwarzbeck             36 M          -            28.02.2020
377         EMI Test Receiver                        ESCS 30                      100160            Rohde & Schwarz         12 M          -            30.05.2019
386         Coupling Decoupling Network              CDN USB/p                    19397             Schaffner               36 M          -            17.05.2020
387         Coupling Decoupling Network              CDN L-801 M2                 2051              Lüthi                   36 M          -            18.05.2020
388         Coupling Decoupling Network              CDN L-801 T2                 1929              Lüthi                   36 M          -            18.05.2020
389         Digital Multimeter                       Keithley 2000                0583926           Keithley                pre-m         -
390         Industry Acoustic System                 MO 2000 Set                  2127100123        Sennheiser              pre-m         2
392         Radio Communication Tester               MT8820A                      6K00000788        Anritsu                 12 M          -            18.05.2018
399         Sound Calibrator                         Sound Calibrator 4231        2665101           Brüel & Kjaer           12 M          -            30.05.2019
431         Model 7405                               Near-Field Probe Set         9305-2457         EMCO                    -             4
436         Univ. Radio Communication Tester         CMU 200                      103083            Rohde & Schwarz         12 M          -            06.03.2019
439         UltraLog-Antenna                         HL 562                       100248            Rohde & Schwarz         36 M          -            10.03.2020
440         CDN for Datacable                        CDN-UTP                      CDN-UTP 029       EMC Partner AG, CH      36 M          -            30.05.2019
                                                                                                    ETS-Lindgren /
442         CTC-SAR-EMS                              System EMS field (SAR)       -                                         12 M          5            20.03.2018
                                                                                                    CETECOM
450         6dB attenuator N/N                       6806.17B 6dB                 -                 Huber & Suhner          12 M          -            20.05.2019
454         Oscilloscope                             HM 205-3                     9210 P 29661      Hameg                   -             4
455         Oscilloscope                             HP 54602B                    US 350 336 45     Hawlett Packard         -             4
456         DC-Power supply 0-5 A                    EA 3013 S                    207810            Elektro Automatik       pre-m         2
459         DC -Power supply 0-5 A , 0-32 V          EA-PS 2032-50                910722            Elektro Automatik       pre-m         2
460         Univ. Radio Communication Tester         CMU 200                      108901            Rohde & Schwarz         12 M          -            30.05.2019
462         AF-Generator                             MX-2020                      -                 Conrad                  -             4
463         Universal source                         HP3245A                      2831A03472        Agilent                 -             4
466         Digital Multimeter                       Fluke 112                    89210157          Fluke USA               24 M          -            30.05.2020
467         Digital Multimeter                       Fluke 112                    89680306          Fluke USA               36 M          -            30.05.2019
468         Digital Multimeter                       Fluke 112                    90090455          Fluke USA               36 M          -            30.04.2021
477         ReRadiating GPS-System                   AS-47                        -                 Automotive Cons. Fink   -             3
480         power meter (Fula)                       NRVS                         838392/031        Rohde & Schwarz         24 M          -            16.05.2019
482         filter matrix                            Filter matrix SAR 1          -                 CETECOM (Brl)           -             1d
                                                                                                    ETS Lindgren /
487         System CTC NSA-Verification SAR-EMI      System EMI field (SAR) NSA   -                                         24 M          -            31.03.2019
                                                                                                    CETECOM
489         EMI Test Receiver                        ESU40                        1000-30           Rohde & Schwarz         12 M          -            18.05.2018
491         ESD Simulator dito                       ESD dito                     dito307022        EM-Test                 12 M          -            30.05.2019
498         Power Supply                             NGPE 40/40                   402               Rohde & Schwarz         pre-m         2
500         Industry Acoustic System                 MO 2000 Set                  100048            Sennheiser              pre-m         2
502         band reject filter                       WRCG 1709/1786-1699/1796-    SN 9              Wainwright              pre-m         2
503         band reject filter                       WRCG 824/849-814/859-        SN 5              Wainwright              pre-m         2
517         relais switch matrix                     HF Relais Box Keithley       SE 04             Keithley                pre-m         2
523         Digital Multimeter                       L4411A                       MY46000154        Agilent                 24 M          -            18.05.2019
524         Voltage Drop Simulator                   VDS 200                      0196-16           EM Test                 24 M          -            16.05.2019
525         CDN coupling network                     CNA 200                      1196-01           EM Test                 24 M          -            16.05.2019
526         Burst Generator                          EFT 200 A                    0496-06           EM Test                 24 M          -            16.05.2019
527         Micro Pulse Generator                    MPG 200 B                    0496-05           EM Test                 24 M          -            16.05.2019
528         Load Dump Simulator                      LD 200B                      0496-06           EM Test                 24 M          -            16.05.2019
529         6 dB Broadband resistive power divider   Model 1515                   LH 855            Weinschel               pre-m         2


CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 23 of 24
 Ref.-No.




                                                                                                                                  calibration
                                                                                                                                  Interval of



                                                                                                                                                    Remark
                             Equipment                              Type                Serial-No.            Manufacturer                                       Cal
                                                                                                                                                                 due

530         10 dB Broadband resistive power divider   R 416110000                   LOT 9828             -                        pre-m         2
533         Impedance Stabilization Network           ISN T200A                     25706                Teseq                    36 M          -            18.05.2020
534         Impedance Stabilization Network           ISN T400A                     24881                Teseq                    36 M          -            18.05.2020
535         Impedance Stabilization Network           ISN T800                      26321                Teseq                    36 M          -            18.05.2020
536         Impedance Stabilization Network           ISN ST08                      25867                Teseq                    36 M          -            18.05.2020
541         Impedance Stabilization Network           ISN T8-Cat6                   26373                Teseq Berlin             36 M          -            18.05.2020
546         Univ. Radio Communication Tester          CMU 200                       106436               R&S                      12 M          -            30.03.2018
547         Univ. Radio Communication Tester          CMU 200                       835390/014           Rohde & Schwarz          12 M          -            05.07.2018
549         Log.Per-Antenna                           HL025                         1000060              Rohde & Schwarz          36/12 M       -            31.07.2018
            System CTC S-VSWR Verification SAR-       System EMI Field SAR S-                            ETS
550                                                                                 -                                             24 M          -            30.03.2019
            EMI                                       VSWR                                               Lindgren/CETECOM
558         System CTC FAR S-VSWR                     System CTC FAR S-VSWR         -                    CTC                      24 M          -            08.08.2019
574         Biconilog Hybrid Antenna                  BTA-L                         980026L              Frankonia                36/12 M       -            31.03.2019
584         Spectrum Analyzer                         FSU 8                         100248               Rohde & Schwarz          pre-m         -
592         CDN-HDMI                                  CDN-HDMI                      A3029004             Frankonia / Dr.Hubert    36 M          -            18.05.2020
595         Analog Adder                              TS8910                        -                    Rohde & Schwarz          pre-m         2
597         Univ. Radio Communication Tester          CMU 200                       100347               Rohde & Schwarz          pre-m         -
600         power meter                               NRVD (Reserve)                834501/018           Rohde & Schwarz          24 M          -            17.05.2019
602         peak power sensor                         NRV-Z32 (Reserve)             835080               Rohde & Schwarz          24 M          -
607         Signal Generator                          SMR 20                        832033/011           Rohde & Schwarz          36 M          -            18.05.2020
611         DC power supply                           E3632A                        KR 75305854          Agilent                  pre-m         2
612         DC power supply                           E3632A                        MY 40001321          Agilent                  pre-m         2
613         Attenuator                                R416120000 20dB 10W           Lot. 9828            Radiall                  pre-m         2
615         Analog Adder                              TS8920                        -                    Rohde & Schwarz          pre-m         2
616         Digitalmultimeter                         Fluke 177                     88900339             Fluke                    24 M          -            30.05.2020
620         EMI Test Receiver                         ESU 26                        100362               Rohde-Schwarz            12 M          -            30.05.2019
625         Generic Test Load USB                     Generic Test Load USB         -                    CETECOM                  -             2
                                                                                    201.0999.9302.6.4.
627         data logger                               OPUS 1                                             G. Lufft GmbH            24 M          -            30.03.2019
                                                                                    1.43
637         High Speed HDMI with Ethernet 1m          HDMI cable with Ethernet 1m   -                    KogiLink                 -             2
638         HDMI Kabel with Ethernet 1,5 m flach      HDMI cable with Ethernet      -                    Reichelt                 -             2
640         HDMI cable 2m rund                        HDMI cable 2m rund            -                    Reichelt                 -             2
641         HDMI cable with Ethernet                  Certified HDMI cable with     -                    PureLink                 -             2
642         Wideband Radio Communication Tester       CMW 500                       126089               Rohde&Schwarz            24 M          -            24.05.2019
644         Amplifierer                               ZX60-2534M+                   SN865701299          Mini-Circuits            -             -
645         Power Amplifier                           CBA 230M-080                  T44236               TESEQ                    -             1g
670         Univ. Radio Communication Tester          CMU 200                       106833               Rohde & Schwarz          24 M          -            30.05.2020
671         DC-power supply 0-5 A                     EA-3013S                      -                    Elektro Automatik        pre-m         2
672         Digitalmultimeter                         Keithley 2700                 1182075              Keithley                 pre-m         -
673         Diditalmultimeter                         Keithley 2700                 1181408              Keithley                 pre-m         -
674         Digitalmultimeter                         Keithley 2700                 1182090              Keithley                 pre-m         -
675         Digitalmultimeter                         Keithley 2700                 1162865              Keithley                 pre-m         -
676         Digitalmultimeter                         Keithley 2700                 1182092              Keithley                 24 M          -            16.05.2019
677         Digitalmultimeter                         Keithley 2700                 1182089              Keithley                 pre-m         -
678         Power Meter                               NRP                           101638               Rohde&Schwarz            pre-m         -
679         Power Supply                              High Speed Power Supply       0783417              Keithley                 pre-m         -
680         Power Sensor                              NRP-Z21                       100622               Rohde & Schwarz          pre-m         -
682         Vector Signal Generator                   SMU 200A                      101319               Rohde & Schwarz          pre-m         -
683         Spectrum Analyzer                         FSU 26                        200571               Rohde & Schwarz          12 M          -            30.05.2019
684         Widerstand 100 Ohm                        SL 403-403                    72973                Teseq                    pre-m         -
685         Widerstand 100 OHM                        SL 403-403                    72974                Teseq                    pre-m         -
                                                                                                         Narda Safety Test
686         Field Analyzer                            EHP-200A                      160WX30702                                    24 M          -            29.03.2019
                                                                                                         Solutions
687         Signal Generator                          SMF 100A                      102073               Rohde&Schwarz            12 M          -            30.05.2019
689         Vector Signal Generator                   SMU200                        100970               Rohde&Schwarz            24 M          -            30.05.2020
690         Spectrum Analyzer                         FSU                           100302/026           Rohde&Schwarz            24 M          -            16.05.2019
692         Bluetooth Tester                          CBT 32                        100236               Rohde & Schwarz          36 M          -            29.05.2020
695         ReRadiating GPS-System                    AS-47                         G1406003500001       Automotive Cons. Fink    -             3
698         Sound Calibrator                          Sound Calibrator 4231         2035208              Brüel & Kjaer            12 M          -            30.05.2019
700         Audio Analyzer                            UPL 16                        830695/0016          Rohde&Schwarz            24 M          -            30.04.2020
705         NRV-Z1                                    Power Sensor                  893350/020           Rohde & Schwarz          12 M          -            30.05.2019
706         NRV-Z1                                    Power Sensor                  830961/001           Rohde &Schwarz           12 M          -            30.05.2019
707         RadiCentre                                CTR-1004B                     10I00037SN038-1      D.A.R.E!! Instruments    24 M          -
            Laser powered Electrical Field Strength                                                      D.A.R.E.!! Instruments
708                                                   RadiSense 6                   10I00037SN038                                 24 M          -            31.03.2019
            Probe                                                                                        BV
710         RF Power Amplifier                        BLMA 2560-100                 1610879              Bonn Elektronik          12 M          -            20.03.2018
711         Harmonic Mixer 90 GHz - 140GHz            RPG FS-Z140                   101004               RPG                      24 M          -            22.02.2019
712         Harmonic Mixer 75 GHz - 110GHz            FS-Z110                       101468               Rohde & Schwarz          24 M          -            22.02.2019
713         Harmonic Mixer, 50 GHz - 75GHz            FS-Z75                        101022               Rohde & Schwarz          24 M          -            22.05.2019
714         Signal Analyzer 67GHz                     FSW67                         104023               Rohde & Schwarz          24 M          -            28.02.2020
                                                                                                         RPG Radiometer
715         Harmonic Mixer, 140 GHz - 220GHz          FS-Z220                       101009                                        24 M          -            03.08.2019
                                                                                                         Physics
716         Harmonic Mixer 220 GHz to 325 GHZ         FS-Z325                       101005               RPG Radiometer Physics   24 M          -            13.02.2019


CETECOM_TR18_1_0081001T22a_C1.docx


Test Report 18-1-0081001T22a-C1, Page 24 of 24
 Ref.-No.




                                                                                                                                        calibration
                                                                                                                                        Interval of



                                                                                                                                                          Remark
                           Equipment                               Type                     Serial-No.             Manufacturer                                        Cal
                                                                                                                                                                       due

717         Signal Generator                          SMP02                            830682/005            Rohde&Schwarz              36 M          -
718         Robot                                     Dasy 5 / TX90                    F11/5GM9A1/A/01       Stäubli                    pre-m         -
747         Spectrum Analyzer                         FSU 26                           200152                Rohde & Schwarz            12 M          -            30.05.2019
751         Digital Optical System                    optoCAN-FD Transceiver           17-010416             mk-messtechnik GmbH        -             -
752         Digital Optical System                    optoCAN-FD Transceiver           17-010083             mk-messtechnik GmbH        -             -
753         Digital Optical System                    optoCAN-FD Transceiver           17-010084             mk-messtechnik GmbH        -             -
754         Digital Optical System                    optoCAN-FD Transceiver           17-010415             mk-messtechnik GmbH        -             -
755         Digital Optical System                    optoLAN-100-MAX                  17-010795             mk-messtechnik GmbH        -             -
            WIDEBAND RADIO
757                                                   CMW500                           163673                Rohde&Schwarz              12 M          -            20.07.2018
            COMMUNICATION
758         Signal Generator                          SMU 200A                         100754                Rohde & Schwarz            24 M          -            11.10.2019
780         Spectrum Analyzer                         FSH3                             101726                Rohde & Schwarz            12 M          -            19.07.2018
                                                                                                             Elektro-Automatik
781         Power Supply                              PS 2042-10 B                     2815450369                                       -             -
                                                                                                             GmbH
                                                                                                             lektro-Automatik GmbH
782         Power Supply                              PS 2042-10 B                     2815450348                                       -             -
                                                                                                             &Co.KG
783         Spectrum Analyzer                         FSU 26                           100414                Rohde & Schwarz            12 M          -            30.05.2019
784         Power Supply                              NGSM 32/10                       00196                 Rohde & Schwarz            12 M          -
785         RSP                                       RF Step Attenuator               860712/012            Rohde & Schwarz            12 M          -



8.1.4. Legend
Note / remarks                             Calibrated during system calibration:
                                 1a        System CTC-SAR-EMS (Ref.-No. 442)
                                 1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                                 1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                                 1d        System CTC-SAR-EMI (Ref.-No . 441)
                                 1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                                 1f        System CTC-CTIA-OTA (Ref.-No . 420)
                                 1g        System CTC-FAR-EMS (Ref.-No . 444)
                                 2         Calibration or equipment check immediately before measurement
                                 3         Regulatory maintained equipment for functional check or support purpose
                                 4         calibration of this equipment
                                           Ancillary equipment   without has no effect
                                                                         calibration   onmechanical
                                                                                     e.g. measuring result
                                                                                                    equipment or monitoring equipment
                                 5         Test System


Interval of calibration          12 M      12 month
                                 24 M      24 month
                                 36 M      36 month
                                 24/12 M   Calibration every 24 months, between this every 12 months internal validation
                                 36/12 M   Calibration every 36 months, between this every 12 months internal validation
                                 Pre-m     Check before starting the measurement
                                 -         Without calibration




9. Versions of test reports (change history)

            Version             Applied changes                                                                                     Date of release
              --                Initial release                                                                                      2018-06-13
              C1                Additional test H-Field 15cm top side                                                                2018-07-16




CETECOM_TR18_1_0081001T22a_C1.docx



Document Created: 2018-07-17 08:44:38
Document Modified: 2018-07-17 08:44:38