Test Report - Part 18 M1

FCC ID: QWY-WMI2W167

Test Report

Download: PDF
FCCID_3720219

                                            TEST REPORT
                                            No.: 17-1-0290001T07



                                                       According to:
                                                     FCC Regulations
                                                            Part 18.305
                                                            Part 18.307




                                                               for

                                          Peiker acustic GmbH

                                        Wireless Mobile Interface
                                            WMI2-W167-M1
                                           2609-090-403-51

                                          FCC-ID: QWY-WMI2W167



                                           Laboratory Accreditation and Listings




                                                                                                  Voluntary Controls for
                                                                            Industry Canada    Electromagnetic Emissions
                                                                           Reg. No.: 3462D-1           Reg. No.:
                                                     MRA US-EU 0003        Reg. No.: 3462D-2        R-2666 C-2914,
                                                                           Reg. No.: 3462D-3        T-1967, G-301




                                     accredited according to DIN EN ISO/IEC 17025
                                                   CETECOM GmbH
                              Laboratory Radio Communications & Electromagnetic Compatibility
                                          Im Teelbruch 116 • 45219 Essen • Germany
                                 Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                               Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                   E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                    Page 1 of 17
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without
the written approval of the testing laboratory                                  © Copyright: All rights reserved by CETECOM


Test Report 17-10290001T07, Page 2 of 17


TABLE OF CONTENTS
1. SUMMARY OF TEST RESULTS...................................................................................................................... 3
  1.1. Tests overview according CFR47, Part 18 ...................................................................................................... 3
2. ADMINISTRATIVE DATA ............................................................................................................................... 4
  2.1. Identification of the testing laboratory ............................................................................................................. 4
  2.2. Test location .................................................................................................................................................... 4
  2.3. Organizational items ........................................................................................................................................ 4
  2.4. Applicant’s details ........................................................................................................................................... 4
  2.5. Manufacturer’s details ..................................................................................................................................... 4
3. EQUIPMENT UNDER TEST (EUT) ................................................................................................................. 5
  3.1. Technical data of main EUT declared by applicant ......................................................................................... 5
  3.2. EUT: Type, S/N etc. and short descriptions used in this test report ................................................................ 5
  3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions .................................................................. 6
  3.4. EUT set-ups ..................................................................................................................................................... 6
  3.5. EUT operating modes ...................................................................................................................................... 6
4. DESCRIPTION OF TEST SYSTEM SET-UP’S .............................................................................................. 7
  4.1. Test system set-up for radiated magnetic field measurements below 30 MHz ................................................ 7
  4.2. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz ............................................... 8
5. MEASUREMENTS ............................................................................................................................................. 9
  5.1. General Limit - Radiated field strength emissions........................................................................................... 9
  5.2. Measurement uncertainties .............................................................................................................................. 12
6. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES ......................... 13
7. INSTRUMENTS AND ANCILLARY ................................................................................................................ 14
  7.1. Used equiment “CTC” ..................................................................................................................................... 14
8. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ............................................................................. 17



Table of annex                        The listed attachments are an integral part of this report                                                     Total pages
Annex 1: Test result diagrams (separate document) CETECOM-TR17-1-0290001T07-A1                                                                                         7
Annex 2: External photographs of EUT (separate document) CETECOM-TR17-1-0290001T07-A2                                                                                  6
Annex 3: Internal photographs of EUT (separate document) CETECOM-TR17-1-0290001T07-A3                                                                                  5
Annex 4: Test set-up photographs (separate document) CETECOM-TR17-1-0290001T07-A4                                                                                      5




CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 3 of 17



1. Summary of test results
The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does
not assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or
samples of the type of the item presented to tests.

The Equipment Under Test (in this report, hereinafter referred as EUT) is a wireless power transfer (WPT)
source with nominal operating frequency 125 kHz.


1.1. Tests overview according CFR47, Part 18
   No. of                                                       References, Standards & Limits                               EUT
                           Test                                                                                 EUT
  Diagram                                                Port                                                                 op-            Result
                           Cases                                   FCC                    Limits               set-up
   group                                                                                                                     mode
                         AC
                      Power Lines
                                                   AC                                   consumer                                           Not
       1                                                          §18.307                                         --             -        Applicable
                      Conducted                 Power lines                             devices
                       emissions
                    0.15 – 30 MHz
                                                  Cabinet +
                       Radiated
                                                   Inter-                             Any non ISM
       2               emissions                                  §18.305                                          1          1+2             Pass
                                                 connecting                            frequency
                    9 kHz-30 MHz
                                                   cables
                                                  Cabinet +
                       Radiated
                                                   Inter-                             Any non ISM
       3               emissions                                  §18.305                                          1          1+2             Pass
                                                 connecting                            frequency
                    30 MHz-1 GHz
                                                   cables




......................................................                                           ....................................................
Dipl.-Ing. Rachid Acharkaoui                                                                                          MSc. Ajit Phadtare
Responsible for test section                                                                               Responsible for test report




CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 4 of 17



2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Dipl.-Ing. Rachid Acharkaoui
Deputy:                                                               Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report :                                         MSc. Ajit Phadtare
Project leader:                                                       Dipl.-Ing. C. Lorenz
Receipt of EUT:                                                       2017-10-30
Date(s) of test:                                                      2017-12-01 - 2017-12-14
Date of report:                                                       2017-12-18
       -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             13.02
2.4. Applicant’s details

Applicant’s name:                                                     Peiker acustic GmbH
Address:                                                              Max-Planck-Str. 28-32
                                                                      61381 Friedrichsdorf

                                                                      GERMANY
Contact person:                                                       Mr. Uwe Hänning



2.5. Manufacturer’s details

Manufacturer’s name:                                                  please see Applicant's details

Address:                                                              please see Applicant's details




CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 5 of 17



3. Equipment under test (EUT)
3.1. Technical data of main EUT declared by applicant
Main function                         Wireless Mobile Interface
Type                                  WMI2-W167-M1 2609-090-403-51
Type of modulation (packet types)     2ASK (Amplitude Shift Keying)
Number of channels
                                      1 nominal channel at 125 kHz
(USA/Canada -bands)
                                       Integrated
Antenna Type                           External, no RF- connector
                                       External, separate RF-connector
Antenna Gain                          0 dBi                                    Flat Coil Antenna
Max. rated value:                     Proprietary Mode (5W)
MAX Field strength (radiated):        10.138 dBμV/m Quasi Peak@300 m distance
99 % Occupied Bandwidth               5.55 kHz ( Mode 2 : TX & RX )
Installed options                      NFC (13.56 MHz) (not tested within this test report)

Power Supply                           12 V DC using Laboratory Power Supply

Special EMI components                --
EUT sample type                        Production       Pre-Production   Engineering
Firmware                                                 for normal use  Special version for test execution
FCC label attached                     yes              no


3.2. EUT: Type, S/N etc. and short descriptions used in this test report
Short
                                                                   S/N              HW                  SW
descrip-            EUT                       Type
                                                                  serial       hardware status     software status
tion*)
                                                                 number
              Wireless Mobile          WMI2-W167-M1
EUT A                                                          0000002363           40.01              45.01
                 Interface             2609-090-403-51
*) EUT short description is used to simplify the identification of the EUT in this test report.




CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 6 of 17


3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions

   AE
                                                                S/N                 HW                   SW
  short     Auxiliary Equipment           Type
                                                           serial number       hardware status      software status
descrip-
 tion *)

 AE 1          Main Harness                 --                   --                    --                  --


             VScom USB-CAN
 AE 2                                USB-CAN Plus           380101643                  --                  --
                 Adapter


 AE 3            USB cable                  --                   --                    --                  --


             Wireless Charging
 AE 4                               WPR1500-LDO              900-28439                 --                  --
                 Receiver


 AE 5         Electronic load           5W/15W                   --                    --                  --

*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.



3.4. EUT set-ups

EUT set-up
                         Combination of EUT and AE                                      Remarks
  no.*)

   set. 1       EUT A + AE 1 + AE 2 + AE 3 + AE 4 + AE 5                                    --
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.


3.5. EUT operating modes

   EUT
                Description of
 operating                                                      Additional information
               operating modes
mode no.*)
                 Wireless
   op. 1      Charging (WPT) WPT Mode 1 charging at 5 Watt nominal setting
              Mode TX only
                 Wireless
    op. 2     Charging (WPT) WPT Mode 2 charging at 5 Watt nominal setting + Data transfer
              Mode TX & RX
*) EUT operating mode no. is used to simplify the test report.




CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 7 of 17



4. Description of test system set-up’s
4.1. Test system set-up for radiated magnetic field measurements below 30 MHz


Specification:              ANSI C63.4-2009 chapter 8.2.1, ANSI C63.10-2013 chapter 6.4

General Description:        Evaluating the radiated field emissions are done first by an exploratory emission
                            measurement and a final measurement for most critical frequencies determined.
                            The loop antenna was placed at 1 m height above ground plane and 3 m
                            measurement distance from set-up for investigations. Because of reduced
                            measurement distance, correction data were applied, as stated in chapter “General
                            Limit - Radiated field strength emissions below 30 MHz“. The tests are
                            performed in the semi anechoic room recognized by the regulatory commission.

Schematic:




Testing method:             Exploratory, preliminary measurement                Final measurement on critical frequencies
                            The EUT and it’s associated accessories are         Based on the exploratory measurements, the most
                            placed on a non-conductive position manipulator     critical frequencies are re-measured by main-
                            (tipping device) of 0.8 m height which is placed    taining the EUT’s worst-case operation mode,
                            on the turntable. By rotating the turntable (step   cable position, etc.
                            90°, range 0°to 360°) and the EUT itself either
                            on 3-orthogonal axis (portable equipment) or 2-     First a frequency zoom around the critical
                            orthogonal axis (defined operational position of    frequency is done to locate the frequency more
                            EUT), the emission spectrum was recorded. The       precisely. After this step, for all identified critical
                            loop antenna was moved at least to                  frequencies, the maximum peak was determined.
                            2-perpendicular axes (antenna vector in direction
                            of EUT and parallel to EUT) in order to             Following parameters were varied: the turntable
                            maximize the emissions. The results are             angle continuously in the range 0 to 360 degree,
                            documented in a diagram. Critical frequencies       the EUT itself either over 3-orthogonal axis (not
                            (low margin to limit) are saved within a data       defined usage position) or 2-orthogonal axis
                            reduction table for further investigations. If      (defined usage position).
                            various operating modes are supported, further
                            investigations are made to find the worst-case.     On the determined worst-case position, a final
                            Also the interconnection cables and equipment       measurement with necessary bandwidth and
                            position were varied in order to maximize the       detector according standard has been carried out.
                            emissions.

Formula:                    EC = ER + AF + CL + DF - GA               AF =Antenna factor
                                                                      CL = Cable loss
                            M = LT-EC                                 DF= Distance correction factor
                                                                      EC = Electrical field – corrected value
                                                                      ER = Receiver reading
                                                                      GA= Gain of pre-amplifier (if used)
                                                                      LT = Limit
                                                                      M = Margin
                            All units are dB-units, positive margin means value is below limit.

Distance correction:        Reference for applied correction (extrapolating) factors:
                            IEEC Transaction EMC, Vol. 47, No. 3 , Aug. 2005, Journal Paper
                            “Extrapolating Near-field emissions of low frequency loop transmitters”.



CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 8 of 17


4.2. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz


Specification:              ANSI C63.4-2009 chapter 8, ANSI C63.10-2013 chapter 6.5

General Description:        Evaluating the field emissions have to be done first by an exploratory emissions
                            measurement and a final measurement for most critical frequencies. The tests are
                            performed in a NSA-compliant semi anechoic room (SAR) recognized by the
                            regulatory commissions.

Schematic:




Testing method:             Exploratory, preliminary measurements                Final measurement on critical frequencies
                            The EUT and its associated accessories are           Based on the exploratory measurements, the most
                            placed on a non-conductive position manipulator      critical frequencies are re-measured by main-
                            (tipping device) of 0.8 m height which is placed     taining the EUT’s worst-case operation mode,
                            on the turntable. By rotating the turntable (range   cable position, etc.
                            0° to 360°, step 90°) and the EUT itself either on
                            3-orthogonal axis (portable equipment) or 2-         First a frequency zoom around the critical
                            orthogonal axis (defined operational position of     frequency is done to locate the frequency more
                            EUT) the emission spectrum and it’s                  precisely. After this step, for all identified critical
                            characteristics was recorded with an EMI-            frequencies, the maximum peak was determined.
                            receiver, broadband antenna and software.
                                                                                 Following parameters were varied: the turntable
                            Measurement antenna: horizontal and vertical,        angle continuously in the range 0 to 360 degree,
                            heights: 1,0 m and 1,82 m as worst-case              the EUT itself either over 3-orthogonal axis (not
                            determined by an exploratory emission                defined usage position) or 2-orthogonal axis
                            measurements. The results are documented in a        (defined usage position). The measurement
                            diagram. Critical frequencies (low margin to         antenna height between 1 m and 4 m.
                            limit) are saved within a table for further
                            investigations. If various operating modes are       On the determined worst-case position, a final
                            supported, further investigations are made to find   measurement with necessary bandwidth and
                            the worst-case of them. Also the interconnection     detector according standard has been carried out.
                            cables and equipment position were varied in
                            order to maximize the emissions.

Formula:                    EC = ER + AF + CL + DF - GA (1)           AF = Antenna factor
                                                                      CL = Cable loss
                            M = LT - EC         (2)                   DF = Distance correction factor (if used)
                                                                      EC = Electrical field – corrected value
                                                                      ER = Receiver reading
                                                                      GA = Gain of pre-amplifier (if used)
                                                                      LT = Limit
                                                                      M = Margin
                            All units are dB-units, positive margin means value is below limit.




CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 9 of 17



5. Measurements
5.1. General Limit - Radiated field strength emissions
5.1.1. Test location and equipment
test location      CETECOM Essen (Chapter. 2.2.1)     Please see Chapter. 2.2.2          Please see Chapter. 2.2.3
test site          441 EMI SAR  487 SAR NSA  347 Radio.lab.                                               
receiver           377 ESCS30      001 ESS                                                               
spectr. analys.    584 FSU         120 FSEM          264 FSEK                                            
antenna            574 BTA-L       021 EMCO6502  302 BBHA9170  289 CBL 6141           
signaling          392 MT8820A  371 CBT32            547 CMU           594 CMW
otherwise          400 FTC40x15E  401 FTC40x15E  110 USB LWL  482 Filter Matrix  378 RadiSense
DC power           087 EA 3013S  457 EA 3013A  459 EA 2032-50  268 EA- 3050            494 AG6632A  498 NGPE 40
line voltage       12 VDC (for EUT A from Laboratory Power Supply)       060 120 V 60 Hz via PAS 5000 (for AE4)

5.1.2. Requirements/Limits
                     FCC                          Part 18.305
                    other                        OET MP-5
                                                                              Radiated emissions limits
                          Operating
                                                     RF Power
     Equipment            Frequency                                                             [dBµV/m] @   Distance Correction
                                                   generated by         [µV/m] @300m
                            [MHz]                                                                  300m       factor 300m-3m
                                                 equipment (watts)

   Any type unless
                          Any ISM                   Below 500                25                     27.95
 otherwise specified                                                                                              See table
                          frequency                500 or more       25 × SQRT(power/500)             --
   (miscellaneous)

                          Any non-
                                                    Below 500                15                     23.52
                             ISM                                                                                  See table
                                                   500 or more       15 × SQRT(power/500)             --
                          frequency



5.1.3. Operating frequencies accord. §18.301
                            ISM Frequency                                                      Tolerance
                              6.78 MHz                                                         ±15.0 kHz
                              13.56 MHz                                                         ±7.0 kHz
                              27.12 MHz                                                        ±163.0 kHz
                              40.68 MHz                                                        ±20.0 kHz
                              915 MHz                                                          ±13.0 MHz
                              2,450 MHz                                                        ±50.0 MHz
                              5,800 MHz                                                        ±75.0 MHz
                             24,125 MHz                                                       ±125.0 MHz
                              61.25 GHz                                                       ±250.0 MHz
                             122.50 GHz                                                       ±500.0 MHz
                             245.00 GHz                                                         ±1.0 GHz



5.1.4. Prohibited frequencies accord. §18.303
                                                                                            Frequencies
                                                                                            490-510 kHz
                                                                                          2170-2194 kHz
                                                                                          8354-8374 kHz
                       Safety and Rescue bands
                                                                                         121.4-121.6 MHz
                                                                                         156.7-156.9 MHz
                                                                                         242.8-243.2 MHz




CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 10 of 17


5.1.5. Test condition and test set-up1: 9kHz to 30MHz
Signal link to test system (if used):          air link      cable connection        none
EUT-grounding                                  none          with power supply  additional connection
Equipment set up                               table top                              floor standing
Climatic conditions                           Temperature: (22±3°C)                   Rel. humidity: (40±20)%
                                               9 – 150 kHz             RBW/VBW = 200 Hz           Scan step = 80 Hz
                     Scan data                 150 kHz – 30 MHz RBW/VBW = 9 kHz                   Scan step = 4 kHz
                                               other:
 EMI-Receiver or Scan-Mode                     6 dB EMI-Receiver Mode  3dB Spectrum analyser Mode
 Analyzer Settings Detector                   Peak (pre-measurement) and Quasi-PK/Average (final if applicable)
                   Mode:                      Repetitive-Scan, max-hold
                   Sweep-Time                 Coupled – calibrated display if continuous signal otherwise adapted to EUT’s individual
                                              transmission duty-cycle
General measurement procedures                Please see chapter “Test system set-up radiated magnetic field measurements below 30 MHz”




5.1.6. Test condition and measurement test set-up2: 30MHz to 1GHz
Signal link to test system (if used):          air link      cable connection         none
 EUT-grounding                                 none          with power supply  additional connection
 Equipment set up                              table top 0.8m height                  floor standing
 Climatic conditions                          Temperature: (22±3°C)                   Rel. humidity: (40±20)%
 EMI-Receiver         Scan frequency range:    30 – 1000 MHz  other:
(Analyzer) Settings Scan-Mode                  6 dB EMI-Receiver Mode  3 dB spectrum analyser mode
                      Detector                Peak / Quasi-peak
                      RBW/VBW                 100 kHz/300 kHz
                      Mode:                   Repetitive-Scan, max-hold
                      Scan step               80 kHz
                      Sweep-Time              Coupled – calibrated display if continuous tx-signal otherwise adapted to EUT’s individual
                                              duty-cycle
General measurement procedures                Please see chapter “Test system set-up for electric field measurement in the range 30 MHz
                                               to 1 GHz”



5.1.7. Measurement Results

               Carrier                                 Set-     OP-
Diagram                                                                                                            Used detector
               Channel         Frequency range          up      mode                    Remark                                        Result
  No.
                                                       no.       no.
                 Range                                                                                            PK AV        QP

                                  100 kHz –
    1          Nominal
                                   145 kHz
                                                        1         1      Carrier Spectrum EUT Laying **                             Pass

                                  100 kHz –
    2          Nominal
                                   145 kHz
                                                        1         2     Carrier Spectrum EUT Standing **                            Pass

                                  100 kHz –
    3          Nominal
                                   145 kHz
                                                        1         2       Carrier Spectrum EUT Laying**                             Pass


                                                                         125 kHz WPT Carrier on diagram:
    4          Nominal         9 kHz- 30 MHz            1         1           Not relevant for verdict                              Pass
                                                                          EUT Laying + EUT Standing**

                                                                         125 kHz WPT Carrier on diagram:
    5          Nominal         9 kHz- 30 MHz            1         2           Not relevant for verdict                              Pass
                                                                          EUT Laying + EUT Standing**

    6          Nominal        30 MHz -1 GHz             1         1        EUT Laying + EUT Standing*                               Pass


    7          Nominal        30 MHz -1 GHz             1         2        EUT Laying + EUT Standing*                               Pass

 ** 300m to 3m distance correction factors used             * 20dB/decade used as correction factor due 3m measurement distance
Remark: 1.) For further details please refer diagrams in separate annex A1




CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 11 of 17


5.1.7.1. Correction factors due to reduced meas. distance (f< 30 MHz)

The used correction factors when the measurement distance is reduced compared to regulatory measurement
distance, are calculated according Extrapolation formulas valid for EUT’s with maximum dimension of
0.625xLambda. Formula 2+3+4 as presented in ANSI C63.10, Chapter 6.4.4 are used for the calculations of
proper extrapolation factors.

         Frequency: 9.00 kHz, Correction: -80.00 dB           Frequency: 1100.00 kHz, Correction: -63.21 dB
         Frequency: 10.00 kHz, Correction: -80.00 dB          Frequency: 1200.00 kHz, Correction: -62.46 dB
         Frequency: 20.00 kHz, Correction: -80.00 dB          Frequency: 1300.00 kHz, Correction: -61.76 dB
         Frequency: 30.00 kHz, Correction: -80.00 dB          Frequency: 1400.00 kHz, Correction: -61.12 dB
         Frequency: 40.00 kHz, Correction: -80.00 dB          Frequency: 1500.00 kHz, Correction: -60.52 dB
         Frequency: 50.00 kHz, Correction: -80.00 dB          Frequency: 1600.00 kHz, Correction: -59.96 dB
         Frequency: 60.00 kHz, Correction: -80.00 dB          Frequency: 1700.00 kHz, Correction: -59.43 dB
         Frequency: 70.00 kHz, Correction: -80.00 dB          Frequency: 1800.00 kHz, Correction: -58.94 dB
         Frequency: 80.00 kHz, Correction: -80.00 dB          Frequency: 1900.00 kHz, Correction: -58.47 dB
         Frequency: 90.00 kHz, Correction: -80.00 dB          Frequency: 2000.00 kHz, Correction: -58.02 dB
        Frequency: 100.00 kHz, Correction: -80.00 dB          Frequency: 2100.00 kHz, Correction: -57.60 dB
        Frequency: 110.00 kHz, Correction: -80.00 dB          Frequency: 2200.00 kHz, Correction: -57.19 dB
        Frequency: 125.00 kHz, Correction: -80.00 dB          Frequency: 2300.00 kHz, Correction: -56.81 dB
        Frequency: 130.00 kHz, Correction: -80.00 dB          Frequency: 2350.00 kHz, Correction: -56.62 dB
        Frequency: 140.00 kHz, Correction: -80.00 dB          Frequency: 2400.00 kHz, Correction: -56.44 dB
        Frequency: 150.00 kHz, Correction: -80.00 dB          Frequency: 2500.00 kHz, Correction: -56.08 dB
        Frequency: 155.00 kHz, Correction: -80.00 dB          Frequency: 2600.00 kHz, Correction: -55.74 dB
        Frequency: 160.00 kHz, Correction: -79.96 dB          Frequency: 2700.00 kHz, Correction: -55.41 dB
        Frequency: 165.00 kHz, Correction: -79.69 dB          Frequency: 2850.00 kHz, Correction: -54.94 dB
        Frequency: 170.00 kHz, Correction: -79.43 dB          Frequency: 3000.00 kHz, Correction: -54.50 dB
        Frequency: 180.00 kHz, Correction: -78.94 dB          Frequency: 3300.00 kHz, Correction: -53.67 dB
        Frequency: 190.00 kHz, Correction: -78.47 dB          Frequency: 3500.00 kHz, Correction: -53.16 dB
        Frequency: 200.00 kHz, Correction: -78.02 dB          Frequency: 3800.00 kHz, Correction: -52.45 dB
        Frequency: 210.00 kHz, Correction: -77.60 dB          Frequency: 4000.00 kHz, Correction: -52.00 dB
        Frequency: 220.00 kHz, Correction: -77.19 dB          Frequency: 4200.00 kHz, Correction: -51.58 dB
        Frequency: 230.00 kHz, Correction: -76.81 dB          Frequency: 4500.00 kHz, Correction: -50.98 dB
        Frequency: 240.00 kHz, Correction: -76.44 dB          Frequency: 4800.00 kHz, Correction: -50.42 dB
        Frequency: 250.00 kHz, Correction: -76.08 dB          Frequency: 5000.00 kHz, Correction: -50.06 dB
        Frequency: 260.00 kHz, Correction: -75.74 dB          Frequency: 5200.00 kHz, Correction: -49.72 dB
        Frequency: 270.00 kHz, Correction: -75.41 dB          Frequency: 5500.00 kHz, Correction: -49.23 dB
        Frequency: 280.00 kHz, Correction: -75.10 dB          Frequency: 5800.00 kHz, Correction: -48.77 dB
        Frequency: 290.00 kHz, Correction: -74.79 dB          Frequency: 6000.00 kHz, Correction: -48.48 dB
        Frequency: 300.00 kHz, Correction: -74.50 dB          Frequency: 6500.00 kHz, Correction: -47.78 dB
        Frequency: 310.00 kHz, Correction: -74.21 dB          Frequency: 7000.00 kHz, Correction: -47.14 dB
        Frequency: 320.00 kHz, Correction: -73.94 dB          Frequency: 8000.00 kHz, Correction: -45.98 dB
        Frequency: 330.00 kHz, Correction: -73.67 dB          Frequency: 9000.00 kHz, Correction: -44.96 dB
        Frequency: 340.00 kHz, Correction: -73.41 dB          Frequency: 10000.00 kHz, Correction: -44.04 dB
        Frequency: 350.00 kHz, Correction: -73.16 dB          Frequency: 11000.00 kHz, Correction: -43.21 dB
        Frequency: 360.00 kHz, Correction: -72.91 dB          Frequency: 12000.00 kHz, Correction: -42.46 dB
        Frequency: 370.00 kHz, Correction: -72.68 dB          Frequency: 13000.00 kHz, Correction: -41.76 dB
        Frequency: 380.00 kHz, Correction: -72.45 dB          Frequency: 13560.00 kHz, Correction: -41.40 dB
        Frequency: 390.00 kHz, Correction: -72.22 dB          Frequency: 14000.00 kHz, Correction: -41.12 dB
        Frequency: 400.00 kHz, Correction: -72.00 dB          Frequency: 15000.00 kHz, Correction: -40.52 dB
        Frequency: 435.00 kHz, Correction: -71.27 dB          Frequency: 15500.00 kHz, Correction: -40.23 dB
        Frequency: 450.00 kHz, Correction: -70.98 dB          Frequency: 15750.00 kHz, Correction: -40.10 dB
        Frequency: 475.00 kHz, Correction: -70.51 dB          Frequency: 15920.00 kHz, Correction: -40.00 dB
        Frequency: 480.00 kHz, Correction: -70.42 dB          Frequency: 16000.00 kHz, Correction: -40.00 dB
        Frequency: 490.00 kHz, Correction: -70.24 dB          Frequency: 17000.00 kHz, Correction: -40.00 dB
        Frequency: 490.10 kHz, Correction: -70.23 dB          Frequency: 18000.00 kHz, Correction: -40.00 dB
        Frequency: 491.00 kHz, Correction: -70.22 dB          Frequency: 19000.00 kHz, Correction: -40.00 dB
        Frequency: 493.00 kHz, Correction: -70.18 dB          Frequency: 20000.00 kHz, Correction: -40.00 dB
        Frequency: 495.00 kHz, Correction: -70.15 dB          Frequency: 21000.00 kHz, Correction: -40.00 dB
        Frequency: 500.00 kHz, Correction: -70.06 dB          Frequency: 22000.00 kHz, Correction: -40.00 dB
        Frequency: 550.00 kHz, Correction: -69.23 dB          Frequency: 23000.00 kHz, Correction: -40.00 dB
        Frequency: 600.00 kHz, Correction: -68.48 dB          Frequency: 24000.00 kHz, Correction: -40.00 dB
        Frequency: 650.00 kHz, Correction: -67.78 dB          Frequency: 25000.00 kHz, Correction: -40.00 dB
        Frequency: 700.00 kHz, Correction: -67.14 dB          Frequency: 26000.00 kHz, Correction: -40.00 dB
        Frequency: 750.00 kHz, Correction: -66.54 dB          Frequency: 27000.00 kHz, Correction: -40.00 dB
        Frequency: 800.00 kHz, Correction: -65.98 dB          Frequency: 28000.00 kHz, Correction: -40.00 dB
        Frequency: 850.00 kHz, Correction: -65.45 dB          Frequency: 29000.00 kHz, Correction: -40.00 dB
        Frequency: 900.00 kHz, Correction: -64.96 dB          Frequency: 30000.00 kHz, Correction: -40.00 dB
        Frequency: 950.00 kHz, Correction: -64.49 dB
        Frequency: 1000.00 kHz, Correction: -64.04 dB




CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 12 of 17


5.2. Measurement uncertainties
The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate
coverage factor k, such that a confidence level of approximately 95% is achieved. For uncertainty determination,
each component used in the concrete measurement set-up was taken in account and it contribution to the overall
uncertainty according it’s statistical distribution calculated.

                                                       Calculated uncertainty based
    RF-Measurement           Reference       Frequency range                                         Remarks
                                                       on a confidence level of 95%
Conducted emissions                 9 kHz - 150 kHz  4.0 dB
                       CISPR 16-2-1                                                                      -
(U CISPR)                           150 kHz - 30 MHz 3.6 dB
Radiated emissions                  30 MHz - 1 GHz   4.2 dB
                       CISPR 16-2-3                                                                   E-Field
Enclosure                           1 GHz - 18 GHz   5.1 dB
Disturbance power      CISPR 16-2-2 30 MHz - 300 MHz -                                                   -
Power Output radiated       -       30 MHz - 4 GHz   3.17 dB                                     Substitution
Power Output conducted      -       9 kHz - 20 GHz   1.0 dB                                              -
Conducted emissions         -       9 kHz - 20 GHz   1.0 dB                                              -
on antenna ports                    20 GHz - 40 GHz
                                                     0.1272 ppm (Delta Marker)                   Frequency error
Occupied bandwidth          -       9 kHz - 4 GHz
                                                     1.0 dB                                      Power
                            -                        0.1272 ppm (Delta Marker)                   Frequency error
Emission bandwidth                  9 kHz - 4 GHz
                            -                        1.0 dB                                      Power
Frequency stability         -       9 kHz - 20 GHz   0.0636 ppm                                          -
                                    150 kHz - 30 MHz 5.0 dB                                      Magnetic field
Radiated emissions
                            -       30 MHz - 1 GHz   4.2 dB                                      E-field
Enclosure
                                    1 GHz - 20 GHz   3.17 dB                                     Substitution
Table: measurement uncertainties, valid for conducted/radiated measurements




CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 13 of 17



6. Accreditation details of CETECOM’s laboratories and test sites

Ref.-   Accreditation                Valid for laboratory area or test site
No.      Certificate                                                                    Accreditation Body
-          D-PL-                                                                  DAkkS, Deutsche
                        All laboratories and test sites of CETECOM GmbH, Essen
        12047-01-01                                                               Akkreditierungsstelle GmbH
337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                  FCC, Federal Communications
487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
     MRA US-EU                                                                    Commission
558                 Radiated Measurements above 1 GHz, 3 m (FAR)
         0003                                                                     Laboratory Division, USA
348                 Mains Ports Conducted Interference Measurements
348                 Telecommunication Ports Conducted Interference Measurem.
337    3462D-1      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)              IC, Industry Canada Certification
550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)               and Engineering Bureau
558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
487     R-2666      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                  VCCI, Voluntary Control Council
550     G-301       Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                  for Interference by Information
348     C-2914      Mains Ports Conducted Interference Measurements
                                                                                  Technology Equipment, Japan
348     T-1967      Telecommunication Ports Conducted Interference Measurem.
OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 14 of 17



7. Instruments and Ancillary
7.1. Used equiment “CTC”
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory
equipment.


7.1.1. Test software and firmware of equipment
 Ref.-No.




                           Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001         EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012         Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013         Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017         Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
053         Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
119         RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
140         Signal Generator                          SMHU                     831314/006          Firm.= 3.21
261         Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262         Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263         Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
                                                                                                   UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295         Racal Digital Radio Test Set              6103                     1572
                                                                                                   SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                   R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298         Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                   all band used
323         Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
335         CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340         Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
355         Power Meter                               URV 5                    891310/027          Firm.= 1.31
365         10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
366         Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371         Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377         EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378         Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
389         Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                   Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392         Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                   4.52#002
                                                                                                   R&S Test Firmware Base=5.14, Mess-Software=
436         Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                   GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441         CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442         CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                      System CTC-FAR-EMI-
443         CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 9.15.00
                                                      RSE
444         CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 9.15.00
                                                                                                   R&S Test Firmware Base=5.14, GSM=5.14
460         Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                   WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489         EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491         ESD Simulator dito                        ESD dito                 dito307022          V 2.30
524         Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
526         Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
527         Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
528         Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                   R&S Test Firmware Base=5.14, GSM=5.14
546         Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                   WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                   R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547         Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                   f. all band used, GSM = 5.14 WCDMA: = 5.14
584         Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                   R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597         Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                   not installed, Mainboard= µP1=V.850
598         Spectrum Analyzer                         FSEM 30 (Reserve)        831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
620         EMI Test Receiver                         ESU 26                   100362              4.43_SP3
642         Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
670         Univ. Radio Communication Tester          CMU 200                  106833              µP1 =V8.50, Firmware = V.20
689         Vector Signal Generator                   SMU200                   100970              02.20.360.142
                                                                                                   CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692         Bluetooth Tester                          CBT 32                   100236
                                                                                                   RF)




CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 15 of 17



7.1.2. Single instruments and test systems
 Ref.-No.




                                                                                                                              calibration
                                                                                                                              Interval of



                                                                                                                                                Remark
                           Equipment                             Type               Serial-No.             Manufacturer                                      Cal
                                                                                                                                                             due

001         EMI Test Receiver                         ESS                     825132/017              Rohde & Schwarz         12 M          -            16.05.2018
005         AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                 861741/005              Rohde & Schwarz         12 M          -            15.05.2018
007         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 892563/002              Rohde & Schwarz         12 M          -            17.05.2018
009         Power Meter (EMS-radiated)                NRV                     863056/017              Rohde & Schwarz         24 M          -            15.05.2019
016         Line Impedance Simulating Network         Op. 24-D                B6366                   Spitzenberger+Spies     36 M          -            30.05.2019
021         Loop Antenna (H-Field)                    6502                    9206-2770               EMCO                    36 M          -            30.04.2018
030         Loop Antenna (H-field)                    HFH-Z2                  879604/026              Rohde & Schwarz         36 M          -            30.04.2018
033         RF-current probe (100kHz-30MHz)           ESH2-Z1                 879581/18               Rohde & Schwarz         24 M          -            15.05.2019
057         relay-switch-unit (EMS system)            RSU                     494440/002              Rohde & Schwarz         pre-m         1a
060         power amplifier (DC-2kHz)                 PAS 5000                B6363                   Spitzenberger+Spies     -             3
086         DC - power supply, 0 -10 A                LNG 50-10               -                       Heinzinger Electronic   pre-m         2
087         DC - power supply, 0 -5 A                 EA-3013 S               -                       Elektro Automatik       pre-m         2
091         USB-LWL-Converter                         OLS-1                   007/2006                Ing. Büro Scheiba       -             4
099         passive voltage probe                     ESH2-Z3                 299.7810.52             Rohde & Schwarz         36 M          -            30.04.2018
100         passive voltage probe                     Probe TK 9416           without                 Schwarzbeck             36 M          -            30.04.2018
110         USB-LWL-Converter                         OLS-1                   -                       Ing. Büro Scheiba       -             4
119         RT Harmonics Analyzer dig. Flickermeter   B10                     G60547                  BOCONSULT               36 M          -            30.05.2019
133         horn antenna 18 GHz (Meas 1)              3115                    9012-3629               EMCO                    36 M          1c           10.03.2020
134         horn antenna 18 GHz (Subst 2)             3115                    9005-3414               EMCO                    36 M          -            10.03.2020
136         adjustable dipole antenna (Dipole 1)      3121C-DB4               9105-0697               EMCO                    36 M          -            30.04.2018
140         Signal Generator                          SMHU                    831314/006              Rohde & Schwarz         24 M          -            30.05.2018
248         attenuator                                SMA 6dB 2W              -                       Radiall                 pre-m         2
249         attenuator                                SMA 10dB 10W            -                       Radiall                 pre-m         2
252         attenuator                                N 6dB 12W               -                       Radiall                 pre-m         2
256         attenuator                                SMA 3dB 2W              -                       Radiall                 pre-m         2
257         hybrid                                    4031C                   04491                   Narda                   pre-m         2
260         hybrid coupler                            4032C                   11342                   Narda                   pre-m         2
261         Thermal Power Sensor                      NRV-Z55                 825083/0008             Rohde & Schwarz         24 M          -            30.05.2018
262         Power Meter                               NRV-S                   825770/0010             Rohde & Schwarz         24 M          -            30.05.2018
263         Signal Generator                          SMP 04                  826190/0007             Rohde & Schwarz         36 M          -            30.05.2019
265         peak power sensor                         NRV-Z33, Model 04       840414/009              Rohde & Schwarz         24 M          -            30.05.2018
266         Peak Power Sensor                         NRV-Z31, Model 04       843383/016              Rohde & Schwarz         24 M          -            30.05.2018
267         notch filter GSM 850                      WRCA 800/960-6EEK       9                       Wainwright GmbH         pre-m         2
270         termination                               1418 N                  BB6935                  Weinschel               pre-m         2
271         termination                               1418 N                  BE6384                  Weinschel               pre-m         2
272         attenuator (20 dB) 50 W                   Model 47                BF6239                  Weinschel               pre-m         2
273         attenuator (10 dB) 100 W                  Model 48                BF9229                  Weinschel               pre-m         2
274         attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W   BG0321                  Weinschel               pre-m         2
275         DC-Block                                  Model 7003 (N)          C5129                   Weinschel               pre-m         2
276         DC-Block                                  Model 7006 (SMA)        C7061                   Weinschel               pre-m         2
279         power divider                             1515 (SMA)              LH855                   Weinschel               pre-m         2
298         Univ. Radio Communication Tester          CMU 200                 832221/091              Rohde & Schwarz         pre-m         3
300         AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                 892 239/020             Rohde & Schwarz         12 M          -            17.05.2018
301         attenuator (20 dB) 50W, 18GHz             47-20-33                AW0272                  Lucas Weinschel         pre-m         2
302         horn antenna 40 GHz (Meas 1)              BBHA9170                155                     Schwarzbeck             36 M          -            14.03.2020
303         horn antenna 40 GHz (Subst 1)             BBHA9170                156                     Schwarzbeck             36 M          -            20.03.2020
331         Climatic Test Chamber -40/+180 Grad       HC 4055                 43146                   Heraeus Vötsch          24 M          -            30.10.2018
341         Digital Multimeter                        Fluke 112               81650455                Fluke                   24 M          -            30.05.2018
342         Digital Multimeter                        Voltcraft M-4660A       IB 255466               Voltcraft               24 M          -            17.05.2019
347         laboratory site                           radio lab.              -                       -                       -             5
348         laboratory site                           EMI conducted           -                       -                       -             5
354         DC - Power Supply 40A                     NGPE 40/40              448                     Rohde & Schwarz         pre-m         2
355         Power Meter                               URV 5                   891310/027              Rohde & Schwarz         24 M          -            30.05.2018
357         power sensor                              NRV-Z1                  861761/002              Rohde & Schwarz         24 M          -            24.05.2019
371         Bluetooth Tester                          CBT32                   100153                  R&S                     36 M          -            30.05.2019
373         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 100535                  Rohde & Schwarz         12 M          -            17.05.2018
377         EMI Test Receiver                         ESCS 30                 100160                  Rohde & Schwarz         12 M          -            15.05.2018
392         Radio Communication Tester                MT8820A                 6K00000788              Anritsu                 12 M          -            18.05.2018
                                                                              126.0604.0003.3.3.3.2   LUFFT Mess u.
405         Thermo-/Hygrometer                        OPUS 10 THI                                                             24 M          -            30.03.2019
                                                                              2                       Regeltechnik
431         Model 7405                                Near-Field Probe Set    9305-2457               EMCO                    -             4
436         Univ. Radio Communication Tester          CMU 200                 103083                  Rohde & Schwarz         12 M          -            24.05.2018
439         UltraLog-Antenna                          HL 562                  100248                  Rohde & Schwarz         36 M          -            10.03.2020
454         Oscilloscope                              HM 205-3                9210 P 29661            Hameg                   -             4
456         DC-Power supply 0-5 A                     EA 3013 S               207810                  Elektro Automatik       pre-m         2
459         DC -Power supply 0-5 A , 0-32 V           EA-PS 2032-50           910722                  Elektro Automatik       pre-m         2
460         Univ. Radio Communication Tester          CMU 200                 108901                  Rohde & Schwarz         12 M          -            16.06.2018
463         Universal source                          HP3245A                 2831A03472              Agilent                 -             4


CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 16 of 17
 Ref.-No.




                                                                                                                                   calibration
                                                                                                                                   Interval of



                                                                                                                                                     Remark
                             Equipment                           Type                     Serial-No.            Manufacturer                                      Cal
                                                                                                                                                                  due

466         Digital Multimeter                        Fluke 112                   89210157                Fluke USA                24 M          -            30.05.2018
467         Digital Multimeter                        Fluke 112                   89680306                Fluke USA                36 M          -            30.04.2018
468         Digital Multimeter                        Fluke 112                   90090455                Fluke USA                36 M          -            30.04.2018
477         ReRadiating GPS-System                    AS-47                       -                       Automotive Cons. Fink    -             3
480         power meter (Fula)                        NRVS                        838392/031              Rohde & Schwarz          24 M          -            16.05.2019
482         filter matrix                             Filter matrix SAR 1         -                       CETECOM (Brl)            -             1d
                                                      System EMI field (SAR)                              ETS Lindgren /
487         System CTC NSA-Verification SAR-EMI                                   -                                                24 M          -            31.03.2019
                                                      NSA                                                 CETECOM
489         EMI Test Receiver                         ESU40                       1000-30                 Rohde & Schwarz          12 M          -            18.05.2019
                                                      WRCG 1709/1786-
502         band reject filter                                                    SN 9                    Wainwright               pre-m         2
                                                      1699/1796-
503         band reject filter                        WRCG 824/849-814/859-       SN 5                    Wainwright               pre-m         2
                                                      WRCA 800/960-02/40-
512         notch filter GSM 850                                                  SN 24                   Wainwrght                12 M          1c           30.06.2017
                                                      6EEK
517         relais switch matrix                      HF Relais Box Keithley      SE 04                   Keithley                 pre-m         2
523         Digital Multimeter                        L4411A                      MY46000154              Agilent                  24 M          -            18.05.2019
529         6 dB Broadband resistive power divider    Model 1515                  LH 855                  Weinschel                pre-m         2
530         10 dB Broadband resistive power divider   R 416110000                 LOT 9828                -                        pre-m         2
546         Univ. Radio Communication Tester          CMU 200                     106436                  R&S                      12 M          -            30.03.2018
547         Univ. Radio Communication Tester          CMU 200                     835390/014              Rohde & Schwarz          12 M          -            05.07.2018
549         Log.Per-Antenna                           HL025                       1000060                 Rohde & Schwarz          36/12 M       -            31.07.2018
            System CTC S-VSWR Verification SAR-       System EMI Field SAR S-                             ETS
550                                                                               -                                                24 M          -            30.03.2019
            EMI                                       VSWR                                                Lindgren/CETECOM
                                                      System CTC FAR S-
558         System CTC FAR S-VSWR                                                 -                       CTC                      24 M          -            08.08.2019
                                                      VSWR
574         Biconilog Hybrid Antenna                  BTA-L                       980026L                 Frankonia                36/12 M       -            31.03.2019
584         Spectrum Analyzer                         FSU 8                       100248                  Rohde & Schwarz          pre-m         -
597         Univ. Radio Communication Tester          CMU 200                     100347                  Rohde & Schwarz          pre-m         -
600         power meter                               NRVD (Reserve)              834501/018              Rohde & Schwarz          24 M          -            17.05.2019
601         medium-sensitivity diode sensor           NRV-Z5 (Reserve)            8435323/003             Rohde & Schwarz          24 M          -            15.05.2019
602         peak power sensor                         NRV-Z32 (Reserve)           835080                  Rohde & Schwarz          24 M          -
611         DC power supply                           E3632A                      KR 75305854             Agilent                  pre-m         2
612         DC power supply                           E3632A                      MY 40001321             Agilent                  pre-m         2
613         Attenuator                                R416120000 20dB 10W         Lot. 9828               Radiall                  pre-m         2
616         Digitalmultimeter                         Fluke 177                   88900339                Fluke                    24 M          -            30.05.2018
617         Power Splitter/Combiner                   ZFSC-2-2-S+                 S F987001108            Mini Circuits            -             2
618         Power Splitter/Combiner                   50PD-634                    600994                  JFW Industries USA       -             2
619         Power Splitter/Combiner                   50PD-634                    600995                  JFW Industries, USA      -             3
620         EMI Test Receiver                         ESU 26                      100362                  Rohde-Schwarz            12 M          -            16.05.2018
621         Step Attenuator 0-139 dB                  RSP                         100017                  Rohde & Schwarz          pre-m         2
625         Generic Test Load USB                     Generic Test Load USB       -                       CETECOM                  -             2
                                                                                  201.0999.9302.6.4.1.4
627         data logger                               OPUS 1                                              G. Lufft GmbH            24 M          -            30.03.2019
                                                                                  3
634         Spectrum Analyzer                         FSM (HF-Unit)               826188/010              Rohde & Schwarz          pre-m         2
                                                      HDMI cable with Ethernet
637         High Speed HDMI with Ethernet 1m                                      -                       KogiLink                 -             2
                                                      1m
638         HDMI Kabel with Ethernet 1,5 m flach      HDMI cable with Ethernet    -                       Reichelt                 -             2
640         HDMI cable 2m rund                        HDMI cable 2m rund          -                       Reichelt                 -             2
641         HDMI cable with Ethernet                  Certified HDMI cable with   -                       PureLink                 -             2
642         Wideband Radio Communication Tester       CMW 500                     126089                  Rohde&Schwarz            12 M          -            24.05.2018
644         Amplifierer                               ZX60-2534M+                 SN865701299             Mini-Circuits            -             -
670         Univ. Radio Communication Tester          CMU 200                     106833                  Rohde & Schwarz          24 M          -            30.05.2018
671         DC-power supply 0-5 A                     EA-3013S                    -                       Elektro Automatik        pre-m         2
678         Power Meter                               NRP                         101638                  Rohde&Schwarz            pre-m         -
683         Spectrum Analyzer                         FSU 26                      200571                  Rohde & Schwarz          12 M          -            17.05.2018
                                                                                                          Narda Safety Test
686         Field Analyzer                            EHP-200A                    160WX30702                                       24 M          -            29.03.2019
                                                                                                          Solutions
687         Signal Generator                          SMF 100A                    102073                  Rohde&Schwarz            12 M          -            17.05.2018
688         Pre Amp                                   JS-18004000-40-8P           1750117                 Miteq                    pre-m         -
690         Spectrum Analyzer                         FSU                         100302/026              Rohde&Schwarz            12 M          -            16.05.2018
691         OSP120 Base Unit                          OSP120                      101183                  Rohde & Schwarz          12 M          -            22.05.2018
692         Bluetooth Tester                          CBT 32                      100236                  Rohde & Schwarz          36 M          -            29.05.2020
697         Power Splitter                            ZN4PD-642W-S+               165001445               Mini-Circuits            -             2
                                                      MA 4010-KT080-XPET-         MA4170-KT100-
703         INNCO Antennen Mast                                                                           INNCO                    pre-m         -
                                                      ZSS3                        XPET-
                                                                                  CO3000/933/3841051
704         INNCON Controller                         CO 3000-4port                                       INNCO Systems GmBh       pre-m         -
                                                                                  6/L
711         Harmonic Mixer 90 GHz - 140GHz            RPG FS-Z140                 101004                  RPG                      12 M          -            22.02.2018
712         Harmonic Mixer 75 GHz - 110GHz            FS-Z110                     101468                  Rohde & Schwarz          12 M          -            22.02.2018
713         Harmonic Mixer, 50 GHz - 75GHz            FS-Z75                      101022                  Rohde & Schwarz          12 M          -            22.05.2018
714         Signal Analyzer 67GHz                     FSW67                       104023                  Rohde & Schwarz          24 M          -            03.03.2019
                                                                                                          RPG Radiometer
715         Harmonic Mixer, 140 GHz - 220GHz          FS-Z220                     101009                                           12 M          -            03.08.2018
                                                                                                          Physics
716         Harmonic Mixer 220 GHz to 325 GHZ         FS-Z325                     101005                  RPG Radiometer Physics   12 M          -            13.02.2018


CETECOM-TR17-1-0290001T07


Test Report 17-10290001T07, Page 17 of 17
 Ref.-No.




                                                                                                                                        calibration
                                                                                                                                        Interval of



                                                                                                                                                          Remark
                           Equipment                             Type                    Serial-No.              Manufacturer                                          Cal
                                                                                                                                                                       due

747         Spectrum Analyzer                         FSU 26                       200152                   Rohde & Schwarz             12 M          -            18.05.2018
748         Pickett-Potter Horn Antenna               FH-PP 4060                   010001                   Radiometer Physiscs         -             -
749         Pickett-potter Horn Antenna               FH-PP 60-90                  010003                   Radiometer Physics          -             -
750         Pickett-Potter Horn Antenna               FH-PP 140-220                010011                   Radiometer Physics          -             -




            7.1.3. Legend


Note / remarks                             Calibrated during system calibration:
                                 1a        System CTC-SAR-EMS (Ref.-No. 442)
                                 1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                                 1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                                 1d        System CTC-SAR-EMI (Ref.-No . 441)
                                 1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                                 1f        System CTC-CTIA-OTA (Ref.-No . 420)
                                 1g        System CTC-FAR-EMS (Ref.-No . 444)
                                 2         Calibration or equipment check immediately before measurement
                                 3         Regulatory maintained equipment for functional check or support purpose
                                 4         calibration of this equipment
                                           Ancillary equipment   without has no effect
                                                                         calibration   onmechanical
                                                                                     e.g. measuring result
                                                                                                    equipment or monitoring equipment
                                 5         Test System


Interval of calibration          12 M      12 month
                                 24 M      24 month
                                 36 M      36 month
                                 24/12 M   Calibration every 24 months, between this every 12 months internal validation
                                 36/12 M   Calibration every 36 months, between this every 12 months internal validation
                                 Pre-m     Check before starting the measurement
                                 -         Without calibration




8. Versions of test reports (change history)

            Version            Applied changes                                                                                          Date of release
              --               Initial release                                                                                           2017-12-18
              --               --                                                                                                             --




CETECOM-TR17-1-0290001T07



Document Created: 2017-12-24 11:47:12
Document Modified: 2017-12-24 11:47:12

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC