RF Exposure Considerations for FCC ID: FCC ID: QVA-PIRCONNECT

The calculation of the MPE is as following:

Prediction of MPE limit at a prediction distance:

       P.G      E.I .R.P
S=            =
     4. ∏ .R ² 4. ∏ .R ²

S: Power density (mW/cm²)
P: Peak output power at antenna terminal (mW)
G: Numerical Antenna gain
R: Distance of radiation to antenna (cm)


MPE calculation


                   Maximum                              Power
Frequency                                 R                            MPE limit        % of limit          Limit
                    E.I.R.P.                          Density S                                                             Verdict
  (MHz)                                 (cm)                           (mW/cm²)                              (%)
                     (mW)                             (mW/cm²)

2402 / 2480            2.0               20             0.0004             1.0              0.04               -
                                                                                                                          Below MPE
                                                                                                                           limit for
     10531            18.2               20            0.00362             1.0             0.362               -
                                                                                                                          uncontrolle
                                                                                                                          d exposure
                  Simultaneous transmissions                             SUM =             0.402            100%


Conclusion: Therefore the device complies with FCC’s RF radiation exposure limits for general
population for a mobile device.


Certified By
Laurent CHAPUS (Agent for this device)
SMEE
Rue de Taille
ZI des Blanchisseries
38500 Voiron - France
laurent.chapus@smee.fr
FCC Registration Number: 0020356952 (FRN)

Applicant for this device:
SORHEA
1 rue du Dauphiné
F-69120 VAULX-EN-VELIN
Aymeric CARADEC
Technical Department Manager
a.caradec@sorhea.fr
+33(0)4 78 03 06 10


COORDONNEES
SMEE                                                                                                  TEL : 04 76 65 76 50
Rue de Taille – ZI Des Blanchisseries                                                                 FAX : 04 76 66 18 30
38500 VOIRON - France
     SAS au capital de 50 000 € / RC Grenoble B534 796 453 / SIRET 534 796 453 00015 / code APE 7490B / n° TVA : FR   59 534 796 453



Document Created: 2019-02-14 14:15:54
Document Modified: 2019-02-14 14:15:54

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC