              Report No               EP1633-1

                     Client           ThingMagic, A division of Trimble
                                      John Carrick

                 Address              1 Merrill Street
                                      Woburn, MA 01801

                    Phone             (781) 305-4321



          Items tested                M6E-NANO

              Standards               FCC 15.247 & RSS-247 (partial testing)

                  FCC ID              QV5MERCURY6EN
                      IC              5407A-MERCURY6EN

                  Results             As detailed within this report


          Prepared by
                                          Tuyen A. Truong – Test Engineer



         Authorized by
                                          Christopher Reynolds – EMC Supervisor




             Issue Date                   9/4/2015


Conditions of Issue                   This Test Report is issued subject to the conditions stated in the ‘Conditions of Testing’
                                      section on page 17 of this report.




Curtis-Straus LLC is accredited by the American Association for Laboratory Accreditation for the specific scope of accreditation under
Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation.
                           ____________________________________________________________
 LLC           Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                             page 1 of 19


            Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
              ______________________________________________________________________




Contents

 Contents .................................................................................................................................. 2
 Summary ................................................................................................................................. 3
 Test Methodology .................................................................................................................... 4
 Product Tested ........................................................................................................................ 5
 Modifications Required for Compliance ................................................................................... 5
 Test Results ............................................................................................................................ 6
   PEAK OUTPUT POWER ..................................................................................................... 6
   NUMBER OF HOPPING FREQUENCIES............................................................................ 9
   CHANNEL FREQUENCY SEPARATION ........................................................................... 11
 Measurement Uncertainty...................................................................................................... 14
 Jurisdictional Labeling and Required Instruction Manual Inserts ............................................ 15
   FCC Requirements ............................................................................................................ 15
 Conditions Of Testing ............................................................................................................ 18

                                                                                                                      REV 28-MAR-12 (KK)




                       ____________________________________________________________
             Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
             One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                           page 2 of 19


             Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
               ______________________________________________________________________



Summary

This report details the partial testing of the M6e-NANO board (with existing FCC
ID:QV5MERCURY6EN and IC:5407A-MERCURY6EN) with the following modifications:

        The channel plan was changed to space 51 channels (formerly 50 channels), with a
        narrower spacing of 100 kHz instead of the original 200 kHz. Per client, this is only a
        software change of the frequency and the end user cannot switch between channel
        plans.


Original (MHz) Channel spacing is 200 KHz

917.4,917.6,917.8,918,918.2,918.4,918.6,918.8,919,919.2,919.4,919.6,919
.8,920,920.2,920.4,920.6,920.8,921,921.2,921.4,921.6,921.8,922,922.2,92
2.4,922.6,922.8,923,923.2,923.4,923.6,923.8,924,924.2,924.4,924.6,924.8,
925,925.2,925.4,925.6,925.8,926,926.2,926.4,926.6,926.8,927,927.2

New (MHz) Channel spacing is 100 Hz

917.5, 917.6, 917.7, 917.8, 917.9, 918, 918.1, 918.2, 918.3, 918.4, 918.5,
918.6, 918.7, 918.8, 918.9, 919, 919.1, 919.2, 919.3, 919.4, 919.5, 919.6,
919.7, 919.8, 919.9, 920, 920.1, 920.2, 920.3, 920.4, 920.5, 920.6, 920.7,
920.8, 920.9, 921, 921.1, 921.2, 921.3, 921.4, 921.5, 921.6, 921.7, 921.8,
921.9, 922, 922.1, 922.2, 922.3, 922.4, 922.5

Three transmitter tests were done to evaluate the above modifications: Number of Channels,
Peak Output Power, and Frequency Separation. We found the product to be compliant with
FCC part 15.247 and RSS-247 for the above tests. Testing of the original channel plan was
previously performed under report EP0016-1.

John Carrick from ThingMagic, A division of Trimble was present during testing. The test sample
was received in good condition.




 Issue No.     Reason for change                   Date Issued

    1          Original Release                    September 4, 2015                                        page 3 of 19

                     _____________________________________________________________
             Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
             One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828


             Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
               ______________________________________________________________________




Test Methodology

Conducted antenna port tests were performed according to DA-00-705 and ANSI C63.10
(2013).




 Issue No.     Reason for change                   Date Issued

    1          Original Release                    September 4, 2015                                        page 4 of 19

                     _____________________________________________________________
             Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
             One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828


              Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
                ______________________________________________________________________



Product Tested

                                                                            EUT Configuration
           Work Order:          P1633
             Company:           ThingMagic, A Division of Trimble
       Company Address:         1 Merrill Street
                                Woburn, MA, 01801

                    Contact:    John Carrick

                                                     MN                                        PN                                      SN
                 EUT:                              M6e Nano                                400-0067-01                            451467701502
       EUT Description:         M6e Nano
    EUT Max Frequency:          922.5 MHz
    EUT Min Frequency:          917.5 MHz

Support Equipment                                              MN                                                            SN
Development Kit                                            430-0033-01                                               SL15013001TMG001
Carrier Board                                             430-0070-01 X2                                                451470702164
AC/DC Power Brick                                               --                                                            --
Laptop                                                          --                                                            --


  Host Port Label        Port Type       # ports      # populated     cable type      shielded   ferrites   length     max     indoor/           comment
                                                                                                              (m)     length   outdoor
                                                                                                                        (m)
J1 Antenna Port         other           1             1             other            No          No                            Indoor    On Board
USB                     USB             1             1             USB              Yes         No         1        5         Indoor    Programming only
AC/DC Power             Power           1             1             Power            No          No         1        --        Indoor

Software Operating Mode Description:
EUT is set to transmit on Low, Mid and High channels from 917.5 to 922.5 MHz




Modifications Required for Compliance
None




                          _____________________________________________________________
                  Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                  One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                           page 5 of 19


                 Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
                   ______________________________________________________________________




Test Results


PEAK OUTPUT POWER
LIMIT
“The maximum peak conducted output power of the intentional radiator shall not exceed…1 watt
for systems employing at least 50 hopping channels...” [FCC 15.247(b)(2)]

Limit = 30dBm

MEASUREMENTS
Results:
Peak Output Power - J1 Antenna Port                                                                        Version 1.017.094
         Date: 16-Jul-15                         Company: Trimble Navigation                                                                          Work Order: P1633
    Engineer: Tuyen Truong                       EUT Desc: M6e Nano                                                      EUT Operating Voltage/Frequency: 5Vdc
        Temp: 23°C                                Humidity: 42%                 Pressure: 1005mBar
                        Frequency Range: Fundamental Frequency
        Notes: Attenuation: 1840 PE7322                       Laird Antenna Gain: 8.15dBiL
               Modulation: CW
                                                                                                                                                        FCC 15.247


                                                                                                                                          Adjusted
                                                Attenuation      Cable      Carrier Board     Adjusted                                    Lim it for
   Channel         Frequency       Reading
                                                   Factor        Factor         Loss          Reading                                   Laird 8.15dBi
                                                                                                                                          Antenna
                                                                                                                                                         Margin       Result
                     (MHz)           (dBm)          (dB)          (dB)          (dBm)           (dBm)                                         (dBm)        (dB)      (Pass/Fail)
     Low             917.5          -3.370         29.65          0.0            0.30          26.580                                         27.85      -1.270        Pass
     Mid             920.0          -3.404         29.65          0.0            0.30          26.546                                         27.85      -1.304        Pass
     High            922.5          -3.523         29.65          0.0            0.30          26.427                                         27.85      -1.423        Pass

       Table Result:               Pass              by          -1.270 MHz                                                           Worst Freq:          917.5 MHz
    Test Site: CEMI5                           Attenuation: 1840 PE7322                            RBW: 300KHz
    Analyzer: Brown                                                                                VBW: 300KHz


Note: Carrier board loss is declared by client and not calibrated by the test lab.
Adjusted Reading = Reading + Attenuation Factor + Carrier Board Loss


Rev. 7/6/2015
      Spectrum Analyzers / Receivers /Preselectors                 Range            MN              Mfr              SN       Asset    Cat     Calibration Due    Calibrated on
                            Brown                             9kHz-26.5GHz        E4407B           Agilent       SG44210511   1510      I         6/30/2016         6/30/2015
_
          Conducted Test Sites (Mains / Telco)                   FCC Code                       VCCI Code                              Cat     Calibration Due    Calibrated on
                           CEMI 5                                 719150                           A-0015                               III          NA                N/A
_
                  Meteorological Meters                                             MN              Mfr              SN       Asset    Cat     Calibration Due    Calibrated on
               Weather Clock (Pressure Only)                                       BA928     Oregon Scientific     C3166-1     831      I         3/19/2016         3/19/2014
                          TH A#2085                                                HTC-1            HDE                       2085      II         4/2/2016          4/2/2015
_
         Preamps /Couplers Attenuators / Filters                   Range            MN              Mfr              SN       Asset    Cat     Calibration Due    Calibrated on
                  HF 30dB 50W Attenuator                       0.009-18 GHz PE 7322-30          Pasternack            1       1840      II        9/16/2015         9/16/2014
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                               _____________________________________________________________
                   Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                      page 6 of 19


          Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
            ______________________________________________________________________



Plot(s)




                                     Peak Output Power – Low Channel




                                     Peak Output Power – Mid Channel
                  _____________________________________________________________
          Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
          One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 7 of 19


Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
  ______________________________________________________________________




                          Peak Output Power – High Channel




        _____________________________________________________________
Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 8 of 19


          Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
            ______________________________________________________________________




NUMBER OF HOPPING FREQUENCIES
LIMIT
“…if the 20dB bandwidth of the hopping channel is less than 250kHz, the system shall use at
least 50 hopping frequencies…
[15.247(a)(1)(i)]

Engineer                        Tuyen A. Truong
Date                            July 16, 2015
Test Site:                      CEMI5
Test Equipments:                Brown SA, #1840 30dB Atttenuation
Temp/Humidity/Pressure          23°C, 42% and 1005mBar
Note:                           Modulation: PR-ASK


MEASUREMENTS / RESULTS

Number of hopping frequencies = 51 Pass


Plot(s)




                 Number of Hopping Frequencies – 51 Channels




                  _____________________________________________________________
          Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
          One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 9 of 19


                 Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
                   ______________________________________________________________________

Rev. 7/6/2015
      Spectrum Analyzers / Receivers /Preselectors                 Range            MN              Mfr              SN       Asset   Cat    Calibration Due   Calibrated on
                            Brown                             9kHz-26.5GHz        E4407B           Agilent       SG44210511   1510     I        6/30/2016        6/30/2015
_
          Conducted Test Sites (Mains / Telco)                   FCC Code                       VCCI Code                             Cat    Calibration Due   Calibrated on
                           CEMI 5                                 719150                           A-0015                              III         NA               N/A
_
                  Meteorological Meters                                             MN              Mfr              SN       Asset   Cat    Calibration Due   Calibrated on
               Weather Clock (Pressure Only)                                       BA928     Oregon Scientific     C3166-1     831     I        3/19/2016        3/19/2014
                          TH A#2085                                                HTC-1            HDE                       2085     II        4/2/2016         4/2/2015
_
         Preamps /Couplers Attenuators / Filters                   Range            MN              Mfr              SN       Asset   Cat    Calibration Due   Calibrated on
                  HF 30dB 50W Attenuator                       0.009-18 GHz PE 7322-30          Pasternack            1       1840     II       9/16/2015        9/16/2014
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                              _____________________________________________________________
                   Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                   page 10 of 19


         Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
           ______________________________________________________________________



CHANNEL FREQUENCY SEPARATION
LIMIT
“Frequency hopping systems shall have hopping channel carrier frequencies separated by a
minimum of 25 kHz or the 20 dB bandwidth of the hopping channel, whichever is greater.”
[15.247(a)(1)]

Limit = 20dB bandwidth = 57.75kHz. (max 20dB BW observed from report EP0016-1)

Engineer                        Tuyen A. Truong
Date                            July 16, 2015
Test Site:                      CEMI5
Test Equipments:                Brown SA, #1840 30dB Atttenuation
Temp/Humidity/Pressure          23°C, 42% and 1005mBar
Note:                           Modulation: PR-ASK

MEASUREMENTS / RESULTS

Channel Frequency Separation = 100 kHz Pass




                                             Low Pairs of Channels




                  _____________________________________________________________
          Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
          One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 11 of 19


Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
  ______________________________________________________________________




                                    Mid Pairs of Channels




                                   High Pairs of Channels


        _____________________________________________________________
Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 12 of 19


                 Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
                   ______________________________________________________________________

Rev. 7/6/2015
      Spectrum Analyzers / Receivers /Preselectors                 Range            MN              Mfr              SN       Asset   Cat    Calibration Due   Calibrated on
                            Brown                             9kHz-26.5GHz        E4407B           Agilent       SG44210511   1510     I        6/30/2016        6/30/2015
_
          Conducted Test Sites (Mains / Telco)                   FCC Code                       VCCI Code                             Cat    Calibration Due   Calibrated on
                           CEMI 5                                 719150                           A-0015                              III         NA               N/A
_
                  Meteorological Meters                                             MN              Mfr              SN       Asset   Cat    Calibration Due   Calibrated on
               Weather Clock (Pressure Only)                                       BA928     Oregon Scientific     C3166-1     831     I        3/19/2016        3/19/2014
                          TH A#2085                                                HTC-1            HDE                       2085     II        4/2/2016         4/2/2015
_
         Preamps /Couplers Attenuators / Filters                   Range            MN              Mfr              SN       Asset   Cat    Calibration Due   Calibrated on
                  HF 30dB 50W Attenuator                       0.009-18 GHz PE 7322-30          Pasternack            1       1840     II       9/16/2015        9/16/2014
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                              _____________________________________________________________
                   Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                   page 13 of 19


              Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
                ______________________________________________________________________



Measurement Uncertainty

The listed uncertainties are the worst case uncertainty for the entire range of measurement. Please note
that the uncertainty values are provided for informational purposes only and are not used in determining
the PASS/FAIL results.

                                 Measurement                                Expanded Uncertainty k=2   Maximum allowable uncertainty
                       Radiated Emissions (30-1000MHz)
                                    NIST                                             5.6dB                          N/A
                                   CISPR                                             4.6dB                     5.2dB (Ucispr)
                        Radiated Emissions (1-26.5GHz)                               4.6dB                          N/A

                      Radiated Emissions (above 26.5GHz)                             4.9dB                          N/A

                          Magnetic Radiated Emissions                                5.6dB                          N/A
                             Conducted Emissions
                                    NIST                                             3.9dB                          N/A
                                   CISPR                                             3.6dB                     3.6dB (Ucispr)
                      Telco Conducted Emissions (Current)                            2.9dB                          N/A

                      Telco Conducted Emissions (Voltage)                            4.4dB                          N/A

                             Electrostatic Discharge                                 11.5%                          N/A

                      Radiated RF Immunity (Uniform Field)                           1.6dB                          N/A

                            Electrical Fast Transients                               23.1%                          N/A

                                     Surge                                           23.1%                          N/A

                            Conducted RF Immunity                                     3dB                           N/A

                               Magnetic Immunity                                     12.8%                          N/A

                               Dips and Interrupts                                    2.3V                          N/A

                                   Harmonics                                         3.5%                           N/A

                                     Flicker                                         3.5%                           N/A
                                                                                               -8
                          Radio frequency (@ 2.4GHz)                               3.23 x 10                      1 x 10-7

                              RF power, conducted                                    0.40dB                       0.75dB
    Maximum frequency deviation:
              Within 300Hz and 6kHz of audio frequency / Within 6kHz and            3.4%                           5%
               25kHz of audio frequency                                              0.3dB                          3dB
                            Adjacent channel power                                   1.9dB                          3dB

        Conducted spurious emission of transmitter, valid up to 12.75GHz             2.39dB                         3dB

                        Conducted emission of receivers                              1.3dB                          3dB

              Radiated emission of transmitter, valid up to 26.5GHz                  3.9dB                          6dB

               Radiated emission of transmitter, valid up to 80GHz                   3.3dB                          6dB

               Radiated emission of receiver, valid up to 26.5GHz                    3.9dB                          6dB

                Radiated emission of receiver, valid up to 80GHz                     3.3dB                          6dB

                                    Humidity                                         2.37%                          5%

                                  Temperature                                        0.7°C                         1.0°C

                                      Time                                           4.1%                          10%

                         RF Power Density, Conducted                                 0.4dB                          3dB

                         DC and low frequency voltages                               1.3%                           3%

                             Voltage (AC, <10kHz)                                    1.3%                           2%

                                  Voltage (DC)                                       0.62%                          1%

    The above reflects a 95% confidence level


                           _____________________________________________________________
                Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                      page 14 of 19


          Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
            ______________________________________________________________________




Jurisdictional Labeling and Required Instruction Manual Inserts

FCC Requirements

Required Equipment Authorization for Device Type
                   Type of Device                                       Equipment Authorization Required
TV broadcast receiver                                                 Verification
FM broadcast receiver                                                 Verification
CB receiver                                                           Declaration of Conformity or Certification
Superregenerative receiver                                            Declaration of Conformity or Certification
Scanning receiver                                                     Certification
Radar detector                                                        Certification
All other receivers subject to part 15                                Declaration of Conformity or Certification
TV interface device                                                   Declaration of Conformity or Certification
Cable system terminal device                                          Declaration of Conformity
Stand-alone cable input selector switch                               Verification
Class B personal computers and peripherals                            Declaration of Conformity or Certification
CPU boards and internal power supplies used with                      Declaration of Conformity or Certification
Class B personal computers
Class B personal computers assembled using                            Declaration of Conformity
authorized CPU boards or power supplies
Class B external switching power supplies                             Verification
Other Class B digital devices & peripherals                           Verification
Class A digital devices, peripherals & external                       Verification
switching power supplies
Access Broadband over Power Line (Access BPL)                         Certification
All other devices                                                     Verification

FCC Required labeling for Verified Devices 47 CFR Part 15.19
The specific labeling requirements for a device subject to the Verification or Certification
procedure are contained in Section 15.19(a). These labelling requirements are:

 • One of three compliance statements specified in Section 15.19(a);
 • If the device is subject only to Verification include a label bearing a unique identifier - Section
    2.954;
 • If the device is subject to Certification (1) Section 2.925 contains information on identification
    of the equipment; (2) include a label bearing an FCC Identifier (FCC ID) - Section 2.926.

If the labeling area for the device is so small, and / or it is not practical to place the required
statement on the device, then the statement can be placed in the user manual or product
packaging - Section 15.19(a)(5). Generally, devices smaller than the palm of the hand are
considered small. However, the device must still be labeled with the unique identifier
(Verification) or the FCC ID (Certification).

Declaration of Conformity (DoC):

                   _____________________________________________________________
           Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
           One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 15 of 19


          Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
            ______________________________________________________________________


The labeling requirements for a device subject to the Declaration of Conformity (DoC) procedure
are specified in Section 15.19(b). The label should include the FCC logo along with the Trade
Name and Model Number, which satisfies the unique identifier requirement of Section 2.1074 if
it represents the identical equipment tested for DoC compliance. For personal computers
assembled from authorized components, the following additional text must also be included:
“Assembled from tested components,” “Complete system not tested.” When the device is so
small and / or when it is not practical to place the required additional text on the device, the text
may be placed in the user manual or pamphlet supplied to the user. However, the FCC logo,
Trade Name, and Model Number must still be displayed on the device - Section 15.19(b)(3).




                           Part 15 Declaration of Conformity (DoC) Label Examples

FCC Required Instruction Manual Inserts CFR 47 Part 15.21 and 15.105
Section 15.21 requires that in the user manual, the user shall be cautioned that changes /
modifications not approved by the responsible party could void the user’s authority to operate
the equipment. The acceptable formats for user information dissemination are paper, computer
disk or over the Internet. Where special accessories, such as shielded cables and/or special
connectors, are required to comply with the emission limits, the instruction manual shall include
appropriate instructions on the first page of the text describing the installation of the device
(Section 15.27(a)).

For a Class A or Class B digital device (unintentional radiator), as well as any composite device
that is both an intentional and unintentional radiator, the text specified in Section 15.105 must
be placed in the user manual.

Devices authorized under the Declaration of Conformity (DoC) procedure must also include a
compliance information statement (in the user manual or on a separate sheet) as required by
Section 2.1077. The objective of this compliance statement is to allow the FCC to associate the
equipment with the party responsible for compliance with the DoC requirements.

Devices certified as software defined radio that use an electronic labeling method to display the
FCC ID must provide instructions in the user manual on how to access the electronic display
(Section 2.925(e)).

Additional statements and information may be required for compliance to specific or general rule
parts. The following is an example of some additional user information requirements. The party
responsible for compliance must provide any additional statement(s) required.

• Kits - TV interface and Cable system terminal device marketed as Kits: Section 15.25 (d);
• TV interface devices, including cable system terminal devices: Section 15.115 (c) (5);
• Labeling of digital cable ready products: Section 15.123 - use of the term cable
  ready/compatible;


                   _____________________________________________________________
           Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
           One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 16 of 19


          Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
            ______________________________________________________________________


• External power amplifiers and antenna modifications: Section 15:204 (d) (2) – 1 notice of
  authorized amplifiers;
• Cordless telephones: Section 15.214 (c) & (d) (3) - privacy statement & security code
  statement;
• Cordless telephones: Section 15.233 (b) (2) (ii) - interference to TV;
• Cordless telephones: Section 15.233 (h) - cordless phones without digital security (Section
  15.214);
• Professionally installed systems: Section 15.247 (c ) (1) (iii);
• Operation within the Band 92-95 GHz: Section 15.257 (a) (4) - indoor use only;
• Unlicensed PCS: Section 15.311 - notification and coordination with UTAM, Inc.;
• RF exposure statements: Section 2.1091 (d) (3) - Mobile devices (a minimum separation
  distance may be required).

Our facility codes can be found in the test equipment lists in each emissions section of this
report.
.




                  _____________________________________________________________
          Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
          One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 17 of 19


               Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
                 ______________________________________________________________________



Conditions Of Testing
     [Bureau Veritas Consumer Products Services, Inc., a Massachusetts corporation], and/or its affiliates (collectively, the
"Company") will conduct, at the request of the Submitter (“Client”), the tests specified on the submitted Test Request Form or equivalent in
accordance with, and subject to, the following terms and conditions (collectively, “Conditions”):
1. All orders for tests are subject to acceptance by the Company, and no order will constitute a binding commitment of the Company unless
and until such order is accepted by it, as evidenced by the issuance of a written report (“Test Report”) by the Company. The Test Report is
issued solely by the Company, is intended for the exclusive use of Client and shall not be published, used for advertising purposes, copied or
replicated for distribution to any other person or entity or otherwise publicly disclosed without the prior written consent of the Company. By
submitting a request for services to the Company, Client consents to the disclosure to accreditation bodies of those records of Client relevant
to the accreditation body's assessment of the Company's competence and compliance with relevant accreditation criteria. The Company
shall not be liable for any loss or damage whatsoever resulting from the failure of the Company to provide its services within any time period
for completion estimated by the Company. If Client anticipates using the Test Report in any legal proceeding, arbitration, dispute resolution
forum or other proceeding, it shall so notify the Company prior to submitting the Test Report in such proceeding. The Company has no
obligation to provide a fact or expert witness at such proceeding unless the Company agrees in advance to do so for a separate and
additional fee.
2. The Test Report will set forth the findings of the Company solely with respect to the test samples identified therein. Unless specifically
and expressly indicated in the Test Report, the results set forth in such Test Report are not intended to be indicative or representative of the
quality or characteristics of the lot from which a test sample is taken, and Client shall not rely upon the Test Report as being so indicative or
representative of the lot or of the tested product in general. The Test Report will reflect the findings of the Company at the time of testing
only, and the Company shall have no obligation to update the Test Report after its issuance. The Test Report will set forth the results of the
tests performed by the Company based upon the written information provided to the Company. The Test Report will be based solely on the
samples and written information submitted to the Company by Client, and the Company shall not be obligated to conduct any independent
investigation or inquiry with respect thereto.
3. The Company may, in its sole discretion, destroy samples which have been furnished to the Company for testing and which have not
been destroyed in the course of testing. The Company may delegate the performance of all or a portion of the services contemplated
hereunder to an affiliate, agent or subcontractor of the Company, and Client consents to such delegation.
4. These Conditions and the Test Report represent the entire understanding of the parties hereto with respect to the subject matter hereof
and of the Test Report, and no modification, variance or extrapolation with respect thereto shall be permitted without the prior written consent
of the Company.
5. The names, service marks, trademarks and copyrights of the Company and its affiliates, including the names “BUREAU VERITAS,”
“BUREAU VERITAS CONSUMER PRODUCTS SERVICES,” “BVCPS”, “MTL”, “ACTS”, “MTL-ACTS” and CURTIS-STRAUS
(collectively, the “Marks”) are and shall remain the sole property of the Company or its affiliates and shall not be used by Client except solely
to the extent that Client obtains the prior written approval of the Company and then only in the manner prescribed by the Company. Client
shall not contest the validity of the Marks or take any action that might impair the value or goodwill associated with the Marks or the image or
reputation of the Company or its affiliates.
6. Payment in full shall be due 30 days after the date of invoice. Interest shall be due on overdue amounts from the due date until paid at an
interest rate of 1.5% per month or, if less, the maximum rate permitted by law. The Company reserves the right, at any time and from time to
time, to revoke any credit extended to Client. Client shall reimburse the Company for any costs it incurs in collecting past due amounts,
including court costs and fees and expenses of attorneys and collection agencies. The Test Report may not be used or relied upon by Client
if and for so long as Client fails to pay when due any invoice issued by the Company or any affiliate of it to Client or any affiliate or subsidiary
of Client together with interest and penalties, if any, accrued thereon.
7. The Company disclaims any and all responsibility or liability arising out of or in connection with e-mail transmissions of such information.
8. Client understands and agrees that the Company is neither an insurer nor a guarantor, that the Company does not take the place of Client
or any designer, manufacturer, agent, buyer, distributor or transportation or shipping company, and that the Company disclaims all liability in
such capacities. Client further understands that if it seeks assurance against loss or damage, it should obtain appropriate insurance.
9. Client agrees that the Company, by providing the services, does not take the place of Client nor any third party, nor does the Company
release them from any of their obligations, nor does the Company otherwise assume, abridge, abrogate or undertake to discharge any duty
of any third party to Client or any duty of Client or any third party to any other third party, and Client will not release any third party from its
obligations and duties with respect to the tested goods.
10. Client shall, on a timely basis, (a) provide adequate instructions to the Company in order to enable the Company to perform properly its
services, (b) provide, or cause Client's suppliers and contractors to provide, the Company with all documents necessary to enable the
Company to perform its services, (c) furnish the Company with all relevant information regarding Client's intended use and purposes of the
tested goods, (d) advise the Company of essential dates and deadlines relevant to the tested goods and (e) fully exercise all rights and
remedies available to Client against third parties in respect of the tested goods.
11. The Company shall undertake due care and ordinary skill in the performance of its services to Client, and the Company shall accept
responsibility only were such skill has not been exercised and, even in such event, only to the extent of the limitation of liability set forth
herein.
12. If Client desires to assert a claim arising from or relating to (i) the performance, purported performance or non-performance of any
services by the Company or (ii) the sale, resale, manufacture, distribution or use of any tested goods, it must submit that claim to the
Company in a writing that sets forth with particularity the basis for such claim within 60 days from discovery of the potential claim and not
more than six months after the date of issuance of the Test Report to Client. Client waives any and all such claims including, without
limitation, claims that the Test Report is inaccurate, incomplete or misleading or that additional or different testing is required, unless and
then only to the extent that Client submits a written claim to the Company within both such time periods.
13. CLIENT SHALL, EXCEPT TO THE EXTENT OF COMPANY’S LIABILITY TO CLIENT HEREUNDER (WHICH IN NO EVENT SHALL
EXCEED THE LIMITATION OF LIABILITY HEREIN), HOLD HARMLESS AND INDEMNIFY THE COMPANY, ITS AFFILIATES AND THEIR
RESPECTIVE DIRECTORS, OFFICERS, EMPLOYEES, AGENTS AND SUBCONTRACTORS AGAINST ALL ACTUAL OR ALLEGED
THIRD PARTY CLAIMS FOR LOSS, DAMAGE OR EXPENSE OF WHATSOEVER NATURE AND HOWSOEVER ARISING FROM OR
RELATING TO (i) THE PERFORMANCE, PURPORTED PERFORMANCE OR NON-PERFORMANCE OF ANY SERVICES BY THE
COMPANY OR (ii) THE SALE, RESALE, MANUFACTURE, DISTRIBUTION OR USE OF ANY TESTED GOODS.
14. EXCEPT AS MAY OTHERWISE BE EXPRESSLY AGREED TO IN WRITING BY THE COMPANY AND NOTWITHSTANDING ANY
PROVISION TO THE CONTRARY CONTAINED HEREIN OR IN ANY TEST REPORT, NO WARRANTY OR GUARANTEE, EXPRESS OR
IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE, IS MADE.


                         _____________________________________________________________
                Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                             page 18 of 19


              Test Report for ThingMagic, A division of Trimble  Report No. EP1633-1 September 4, 2015
                ______________________________________________________________________


15. (A) IN NO EVENT WHATSOEVER SHALL THE COMPANY BE LIABLE FOR ANY CONSEQUENTIAL, SPECIAL, INCIDENTAL,
EXEMPLARY OR PUNITIVE DAMAGES IN CONNECTION WITH, RELATING TO OR ARISING OUT OF THE TEST REPORT OR THE
SERVICES PROVIDED BY THE COMPANY HEREUNDER, INCLUDING WITHOUT LIMITATION LOSS OF OR DAMAGE TO PROPERTY;
LOSS OF INCOME, PROFIT OR USE; OR ANY CLAIMS OR DEMANDS MADE AGAINST CLIENT OR ANY OTHER PERSON BY ANY
THIRD PARTY IN CONNECTION WITH, RELATING TO OR ARISING OUT OF THE SERVICES PROVIDED BY THE COMPANY
HEREUNDER.
  (B)NOTWITHSTANDING ANY PROVISION TO THE CONTRARY CONTAINED HEREIN, AND IN RECOGNITION OF THE RELATIVE
RISKS AND BENEFITS TO CLIENT AND THE COMPANY ASSOCIATED WITH THE TESTING SERVICES CONTEMPLATED HEREBY,
THE RISKS HAVE BEEN ALLOCATED SUCH THAT UNDER NO CIRCUMSTANCES WHATSOEVER SHALL THE LIABILITY OF THE
COMPANY TO CLIENT OR ANY THIRD PARTY IN RESPECT OF ANY CLAIM FOR LOSS, DAMAGE OR EXPENSE, OF WHATSOEVER
NATURE OR MAGNITUDE, AND HOWSOEVER ARISING, EXCEED AN AMOUNT EQUAL TO FIVE (5) TIMES THE AMOUNT OF THE
FEES PAID TO THE COMPANY FOR THE SPECIFIC SERVICES WHICH GAVE RISE TO SUCH CLAIM OR U.S.$10,000, WHICHEVER IS
THE LESSER AMOUNT.
16. The Company shall not be liable for any loss or damage resulting from any delay or failure in performance of its obligations hereunder
resulting directly or indirectly from any event of force majeure or any event outside the control of the Company. If any such event occurs, the
Company may immediately cancel or suspend its performance hereunder without incurring any liability whatsoever to Client.
 17. Company’s services, including these Conditions, shall be governed by, and construed in accordance with, the local laws of the country
where the Company performs the tests or, in the case of tests performed in the United States of America, the laws of Massachusetts without
regard to conflicts of laws principles. If any aspect(s) of these Conditions is found to be illegal or unenforceable, the validity, legality and
enforceability of all remaining aspects of these Conditions shall not in any way be affected or impaired thereby. Any proceeding related to
the subject matter hereof shall be brought, if at all, in the courts of the country where the Company performs the tests or, in the case of tests
performed in the United States of America, in the courts of Massachusetts. Client waives the right to interpose any counterclaim or setoffs of
any nature in any litigation arising hereunder.
The complete list of the Approved Subcontractors Curtis-Straus may use to delegate the performance of work can be provided upon request.
Rev.160009121(2)_#684340 v14CS




                         _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                            page 19 of 19



Document Created: 2015-10-23 10:53:46
Document Modified: 2015-10-23 10:53:46

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC