Test Report DCD

FCC ID: QUI-HN-MFG-C

Test Report

Download: PDF
FCCID_2508943

              FCC/Industry Canada Certification Test Report
                                                          For the
                               Frederick Energy Products LLC
                          Magnetic Field Generator with CAM
                                     FCC ID: QUI-HN-MFG-C
                                     IC: 11625A-HNMFGWCA

                                            WLL JOB# 13305-01 Rev 1
                                               February 11, 2014
                                             Revised January 6, 2015



                                                        Prepared for:

                                       Frederick Energy Products LLC
                                               1769 Jeff Road
                                            Huntsville, AL 35806



                                                                                                                       Prepared By:

                                                                                            Washington Laboratories, Ltd.
                                                                                                    7560 Lindbergh Drive
                                                                                            Gaithersburg, Maryland 20879




                                                                                                     Testing Certificate AT-1448




Certificates and reports shall not be reproduced except in full, without the written permission of Washington Laboratories, Limited.


Frederick Energy Products LLC                                   FCC/IC Certification Test Report
Magnetic Field Generator                                                           January 2014




             FCC/Industry Canada Certification Test Report
                                          for the
                             Frederick Energy Products LLC
                                Magnetic Field Generator
                                       With CAM


                                FCC ID: QUI-HN-MFG-C
                                IC: 11625A-HNMFGWCA
                                     February 11, 2014
                                   Revised January 6, 2015
                                  WLL JOB# 13305-01 Rev 0

                                        Prepared by:




                                       John P. Repella
                                     Compliance Engineer


                                        Reviewed by:




                                        James Ritter
                                   EMC compliance Engineer




WLL Report #13305-01 Rev 1                    ii             © 2015 Washington Laboratories, Ltd


    Frederick Energy Products LLC                                       FCC/IC Certification Test Report
    Magnetic Field Generator w CAM                                                      February , 2014




                                                   Abstract
    This report has been prepared on behalf of Frederick Energy Products LLC to support the
    attached Application for Equipment Authorization. The test report and application are
    submitted for a Transmitter under Part 15.209 (10/2013) of the FCC Rules and
    Regulations and Industry Canada RSS-210 issue 8 (12/2010) and RSS-Gen issue 3
    (12/2010). This Certification Test Report documents the test configuration and test results
    for the Frederick Energy Products LLC Magnetic Field Generator.
    Testing was performed on an Open Area Test Site (OATS) of Washington Laboratories,
    Ltd, 7560 Lindbergh Drive, Gaithersburg, MD 20879. Site description and site
    attenuation data have been placed on file with the FCC's Sampling and Measurements
    Branch at the FCC laboratory in Columbia, MD. The Industry Canada OATS numbers are
    3035A-1 and 3035A-2 for Washington Laboratories, Ltd. Site 1 and Site 2, respectively.
    Washington Laboratories, Ltd. has been accepted by the FCC and approved by ACLASS
    under Certificate AT-1448 as an independent FCC test laboratory.
    The Frederick Energy Products LLC Magnetic Field Generator complies with the limits
    for a Transmitter device under FCC Part 15.209 and RSS210 issue 8.




   Revision History                          Description of Change                          Date
Rev 0                            Initial Release                                February 11, 2014
Rev 1                            Revised model number to HN-MFG-C               January 6, 2015 JR




    WLL Report #13305-01 Rev 1                        iii            © 2015 Washington Laboratories, Ltd


Frederick Energy Products LLC                                                                        FCC/IC Certification Test Report
Magnetic Field Generator w CAM                                                                                       February , 2014



Table of Contents
Abstract ............................................................................................................................... ii
1      Introduction ..............................................................................................................1
  1.1      Compliance Statement ........................................................................................ 1
  1.2      Test Scope ........................................................................................................... 1
  1.3      Contract Information ........................................................................................... 1
  1.4      Test Dates............................................................................................................ 1
  1.5      Test and Support Personnel ................................................................................ 1
  1.6      Abbreviations ...................................................................................................... 2
2      Equipment Under Test .............................................................................................3
  2.1      EUT Identification & Description....................................................................... 3
  2.2      Test Configuration .............................................................................................. 3
  2.3      Equipment Configuration.................................................................................... 4
  2.4      Support Equipment ............................................................................................. 4
  2.5      Interface Cables................................................................................................... 5
  2.6      EUT Modifications ............................................................................................. 5
  2.7      Testing Algorithm ............................................................................................... 5
  2.8      Test Location....................................................................................................... 5
  2.9      Measurements ..................................................................................................... 5
    2.9.1 References ....................................................................................................... 5
  2.10 Measurement Uncertainty ................................................................................... 6
3      Test Equipment ........................................................................................................7
4      Test Results ..............................................................................................................8
  4.1      Occupied Bandwidth: (FCC Part §2.1049, RSS –Gen sect 4.6.1) ...................... 8
  4.2      Radiated Spurious Emissions: (FCC Part §15.209, RSS-Gen Table 6).............. 8
    4.2.1 Test Procedure ................................................................................................ 8
  4.3      Receiver Radiated Emissions (RSS-210 sect 2.5, RSS-GEN sect 6.1) ............ 12
    4.3.1 Requirements ................................................................................................ 12
    4.3.2 Test Procedure .............................................................................................. 12
    4.3.3 Test Data ....................................................................................................... 12
    4.3.4 Radiated Data Reduction and Reporting....................................................... 13




WLL Report #13305-01 Rev 1                                          iv                          © 2015 Washington Laboratories, Ltd


Frederick Energy Products LLC                                                                FCC/IC Certification Test Report
Magnetic Field Generator w CAM                                                                               February , 2014




List of Tables
Table 1: Device Summary................................................................................................... 3
Table 2: Equipment Configuration ..................................................................................... 4
Table 3: Support Equipment ............................................................................................... 4
Table 4: Interface Cables .................................................................................................... 5
Table 5: Expanded Uncertainty List ................................................................................... 7
Table 6: Test Equipment List .............................................................................................. 7
Table 7: Radiated Emissions Limits ................................................................................... 8
Table 8: Radiated Emissions Test Data < 30MHz ............................................................ 10
Table 9: Radiated Emissions Test Data > 30MHz (TX and RCV) ................................... 11
Table 10: Receiver Radiated Emissions Test Data > 30MHz (TX and RCV) .................. 14

List of Figures
Figure 1: Test Configuration ............................................................................................... 4




WLL Report #13305-01 Rev 1                                     v                         © 2015 Washington Laboratories, Ltd


      Frederick Energy Products LLC                                     FCC/IC Certification Test Report
      Magnetic Field Generator w CAM                                                    February , 2014




1     Introduction
1.1     Compliance Statement
         The Frederick Energy Products LLC Magnetic Field Generator w CAM complies with the
         limits for an Intentional Radiator device under Part 15.209 of the FCC Rules and
         Regulations and Industry Canada RSS-210 issue 8.

1.2     Test Scope
         Tests for radiated emissions were performed. All measurements were performed according
         to the 2003 version of ANSI C63.4. The measurement equipment conforms to ANSI C63.2
         Specifications for Electromagnetic Noise and Field Strength Instrumentation.

1.3     Contract Information
         Customer:                                             Frederick Energy Products LLC
                                                               1769 Jeff Drive,
                                                               Huntsville, AL, 35806

         Quotation Number:                                     67877

1.4     Test Dates
         Testing was performed on the following date(s):       1/27/2014

1.5     Test and Support Personnel
         Washington Laboratories, LTD                          John P. Repella
         Customer Representative                               Ed Richardson, Ishmael Chigumira




WLL Report #13305-01 Rev 1                        - 1 of 14-            © 2015 Washington Laboratories, Ltd.


      Frederick Energy Products LLC                             FCC/IC Certification Test Report
      Magnetic Field Generator w CAM                                            February , 2014



1.6     Abbreviations
A                      Ampere
Ac                     alternating current
AM                     Amplitude Modulation
Amps                   Amperes
b/s                    bits per second
BW                     Bandwidth
CE                     Conducted Emission
Cm                     centimeter
CW                     Continuous Wave
dB                     decibel
Dc                     direct current
EMI                    Electromagnetic Interference
EUT                    Equipment Under Test
FM                     Frequency Modulation
G                      giga - prefix for 109 multiplier
Hz                     Hertz
IF                     Intermediate Frequency
K                      kilo - prefix for 103 multiplier
M                      Mega - prefix for 106 multiplier
M                      Meter
                     micro - prefix for 10-6 multiplier
NB                     Narrowband
LISN                   Line Impedance Stabilization Network
RE                     Radiated Emissions
RF                     Radio Frequency
Rms                    root-mean-square
SN                     Serial Number
S/A                    Spectrum Analyzer
V                      Volt




WLL Report #13305-01 Rev 1                         - 2 of 14-   © 2015 Washington Laboratories, Ltd.


      Frederick Energy Products LLC                                      FCC/IC Certification Test Report
      Magnetic Field Generator w CAM                                                     February , 2014




2     Equipment Under Test
2.1     EUT Identification & Description
        The Frederick Energy product, LLC Magnetic Field Generator w CAM produces a 73 kHz
        proximity field (CW signal). When a Personal Alarm Device (PAD) enters this field it
        causes the PAD unit to visually and audibly alarm. In addition the PAD unit sends data
        back to the Magnetic Field Generator receiver on 916 MHz that causes the generator to
        visibly and audibly alarm. The Magnetic field generator is comprised of the main unit and
        a warning module that contains a visual and audible alarm.
        This device is used with the generator mounted on a vehicle while the PAD units are worn
        by personnel to warn both the equipment operators and people in the proximity of this
        equipment of possibly dangerous conditions.

                                       Table 1: Device Summary
                         ITEM                               DESCRIPTION
             Manufacturer:               Frederick Energy Products LLC
             FCC ID:                     QUI-HN-MFG-C
             IC:                         11625A-HNMFGWCA
             EUT Name:                   Magnetic Field Generator w/ CAM
             Model:                      HN-MFG-C
             FCC Rule Parts:             15.209
             IC Rule Part                RSS210 issue 8 (RSS-Gen Issue 3)
             IC Emission Designator      NON
             Frequency Range:            73kHz
             Occupied Bandwidth:         N/A CW non modulated signal
             Keying:                     Automatic
             Type of Information:        CW (illumination)
             Number of Channels:         1
             Power Output Level          Fixed
             Antenna Type                Integral Magnetic Induction
             Interface Cables:           Power, warning module cable
             Power Source & Voltage:     Battery (12 VDC)
             Highest TX emission         73kHz , -8.4dB Margin
             Highest RX emission         78.93MHz, -1.7dB Margin


2.2     Test Configuration
        The Frederick Energy Products LLC Magnetic Field Generator, Equipment Under Test
        (EUT), was operated from 12VDC via a Lab AC/DC power supply.



WLL Report #13305-01 Rev 1                          - 3 of 14-           © 2015 Washington Laboratories, Ltd.


      Frederick Energy Products LLC                                       FCC/IC Certification Test Report
      Magnetic Field Generator w CAM                                                      February , 2014




                                         Figure 1: Test Configuration

2.3     Equipment Configuration
        The EUT was set up as outlined in Figure 1. The EUT was comprised of the following
        equipment. (All Modules, PCBs, etc. listed were considered as part of the EUT, as tested.)

                                       Table 2: Equipment Configuration

Name / Description                 Manufacturer                   Model   Serial Number            Revision
   Magnetic Field
                             Frederick Energy Products        HN-MFG-C          FCC02                 #25
     Generator
    (2) Warning                                                              WMS03553
                             Frederick Energy Products       HN-WM-LS                                  --
      Modules                                                                WMS03597


2.4     Support Equipment
        The following support equipment was used during testing:

                                         Table 3: Support Equipment
              Item                         Model/Part Number                    Serial Number
              PAD                               HN-PAD                             PD01163
 Power Supply (Primary)                   1337DC Power Supply                          N/A


WLL Report #13305-01 Rev 1                               - 4 of 14-       © 2015 Washington Laboratories, Ltd.


      Frederick Energy Products LLC                                         FCC/IC Certification Test Report
      Magnetic Field Generator w CAM                                                        February , 2014



2.5     Interface Cables

                                           Table 4: Interface Cables
          Port                 Connector        Cable         Shielded
                                                                               Termination Point
      Identification             Type           Length         (Y/N)
                             2 wire to 4 Pin
      12Vdc input                                >1 m                 N      Power source to EUT
                                Circular

  Warning Module             4 wire circular     >1m                  N   Magnetic Field Generator to
                                                                               Warning Module
  Warning Module             4 wire circular     >1m                  N   Warning Module 1 to Warning
                                                                                  Module 2


2.6     EUT Modifications
        No modifications were performed in order to meet the test requirements.

2.7     Testing Algorithm
        The EUT operates continuously when power is applied.
        Worst case emission levels are provided in the test results data. PAD support unit was
        brought within range of the generator to activate receive warning alarms.

2.8     Test Location
        Testing was performed on an Open Area Test Site (OATS) of Washington Laboratories,
        Ltd, 7560 Lindbergh Drive, Gaithersburg, MD 20879. Site description and site attenuation
        data have been placed on file with the FCC's Sampling and Measurements Branch at the
        FCC laboratory in Columbia, MD. The Industry Canada OATS numbers are 3035A-1 and
        3035A-2 for Washington Laboratories, Ltd. Site 1 and Site 2, respectively. Washington
        Laboratories, Ltd. has been accepted by the FCC and approved by ACLASS under
        Certificate AT-1448 as an independent FCC test laboratory.

2.9     Measurements
2.9.1 References
        ANSI C63.2 Specifications for Electromagnetic Noise and Field Strength Instrumentation
        ANSI C63.4 American National Standard for Methods of Measurement of Radio-Noise
        Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to
        40 GHz




WLL Report #13305-01 Rev 1                               - 5 of 14-         © 2015 Washington Laboratories, Ltd.


    Frederick Energy Products LLC                                          FCC/IC Certification Test Report
    Magnetic Field Generator w CAM                                                         February , 2014




2.10 Measurement Uncertainty
       All results reported herein relate only to the equipment tested. The basis for uncertainty
       calculation uses ANSI/NCSL Z540-2-1997 with a type B evaluation of the standard
       uncertainty. Elements contributing to the standard uncertainty are combined using the
       method described in Equation 1 to arrive at the total standard uncertainty. The standard
       uncertainty is multiplied by the coverage factor to determine the expanded uncertainty
       which is generally accepted for use in commercial, industrial, and regulatory applications
       and when health and safety are concerned (see Equation 2). A coverage factor was selected
       to yield a 95% confidence in the uncertainty estimation.

                                     Equation 1: Standard Uncertainty

                                     a2       b2       c2
                             uc        2
                                                 2
                                                          2
                                                              .......
                                    diva     divb     divc

                             Where uc      = standard uncertainty
                                 a, b, c,.. = individual uncertainty elements
                                 Diva, b, c = the individual uncertainty element divisor based on the
                                                             probability distribution
                                                  Divisor = 1.732 for rectangular distribution
                                                  Divisor = 2 for normal distribution
                                                  Divisor = 1.414 for trapezoid distribution


                                     Equation 2: Expanded Uncertainty

                                               U  kuc

                             Where U              = expanded uncertainty
                                     k            = coverage factor
                                                  k ≤ 2 for 95% coverage (ANSI/NCSL Z540-2
                             Annex G)
                                     uc           = standard uncertainty




WLL Report #13305-01 Rev 1                            - 6 of 14-           © 2015 Washington Laboratories, Ltd.


      Frederick Energy Products LLC                                              FCC/IC Certification Test Report
      Magnetic Field Generator w CAM                                                             February , 2014



           The measurement uncertainty complies with the maximum allowed uncertainty from
           CISPR 16-4-2. Measurement uncertainty is not used to adjust the measurements to
           determine compliance. The expanded uncertainty values for the various scopes in the
           WLL accreditation are provided in Table 5 below.

                                       Table 5: Expanded Uncertainty List
                                                                                                     Expanded
              Scope                                     Standard(s)
                                                                                                    Uncertainty

      Conducted Emissions                 CISPR11, CISPR22, CISPR14, FCC Part 15                       +2.63 dB
       Radiated Emissions                 CISPR11, CISPR22, CISPR14, FCC Part 15                       +4.55 dB
.

3      Test Equipment
       Table 6 shows a list of the test equipment used for measurements along with the calibration
       information.

                                          Table 6: Test Equipment List

Test Name:     Radiated Emissions                                                         Test Date:     01/27/2014

    Asset #               Manufacturer/Model                              Description                     Cal. Due
      68                       HP - 85650A                               ADAPTER QP                       1/9/2015

      70                       HP - 85685A                    PRESELECTOR RF W/OPT 8ZE                    1/9/2015

      72                       HP - 8568B                            ANALYZER SPECTRUM                    1/9/2015

     644         SUNOL SCIENCES CORPORATION -                        ANTENNA BICONLOG                    1/17/2016
                             JB1
      4                      ARA - DRG-118/A                         ANTENNA DRG 1-18GHZ                 2/20/2015

      66          B&Z - BZ-01002650-401545-282525            PRE-AMPLIFIER RF. 1-26.5GHZ                 10/2/2014

      31                       EMCO 6502                                 ACTIVE LOOP                       2/23/14




WLL Report #13305-01 Rev 1                              - 7 of 14-               © 2015 Washington Laboratories, Ltd.


      Frederick Energy Products LLC                                          FCC/IC Certification Test Report
      Magnetic Field Generator w CAM                                                         February , 2014




4     Test Results
4.1     Occupied Bandwidth: (FCC Part §2.1049, RSS –Gen sect 4.6.1)
         Occupied bandwidth was performed by setting the EUT near the loop antenna to allow for
         sufficient pickup of the signal.
         The transmit signal is a 73 kHz non-modulated CW signal; therefore there is no
         measurable bandwidth.

4.2     Radiated Spurious Emissions: (FCC Part §15.209, RSS-Gen Table 6)
         Transmitters operating under §15.209 & Industry Canada RSS 210 (RSS-GEN) must
         comply with the radiated emissions listed in the following table:

                                       Table 7: Radiated Emissions Limits
                Frequency                        Field Strength             Measurement Distance
                   (MHz)                       (microvolts/meter)                   (meters)
               0.009 - 0.490                      2400/F(kHz)                          300
               0.490 - 1.705                      24000/F(kHz)                          30
                1.705 - 30.0                          30                                30
                   30 - 88                            100                                3
                  88 - 216                            150                                3
                 216 - 960                            200                                3
                 Above 960                            500                                3


4.2.1 Test Procedure
          The EUT was placed on motorized turntable for radiated testing on a 30-meter open field
          test site. The emissions from the EUT were measured continuously at every azimuth by
          rotating the turntable

          For frequencies between 10 kHz and 30 MHz, a loop antenna was mounted of a tripod at
          height of 1 m. The Loop antenna was rotated about its vertical and horizontal axis to
          determine the highest emissions.

          For frequencies above 30MHz the receiving antennas were mounted on an antenna mast
          to determine the height of maximum emissions. The height of the antenna was varied
          between 1 and 4 meters. Both the horizontal and vertical field components were
          measured.




WLL Report #13305-01 Rev 1                              - 8 of 14-           © 2015 Washington Laboratories, Ltd.


    Frederick Energy Products LLC                                     FCC/IC Certification Test Report
    Magnetic Field Generator w CAM                                                    February , 2014



       Measurements of frequencies above 30MHz were made at a distance of 3m.
       The EUT was scanned from 10k to 3GHz (in order to include the receiver data).
       The limit at 300m has been interpolated to 30m.

       The roll-off was determined as specified in FCC part 15.31 (f)(2) two measurements were
       made at two distances, 3m and 30m.
       The level of the fundamental frequency at 3m was measured as 120.8dBuV/m
       The level of the fundamental frequency at 30m was measured as 69.8dBuV/m
       The difference between the two readings is 51.0dB therefore the roll-off is 51.0dB/decade.
       This offset was added to the 300m limit to adjust the limit to 30m:
       Example @ 73 kHz:
       300m limit = 2400/73 = 32.8767uV/m = 20*Log (32.8767) = 30.3377dBuV/m
       30m limit = 30.3377dBuV/m +51.0dB = 81.3dBuV/m = 10^ (81.3377/20) = 11665.1uV/m
       The EUT was examined in three orthogonals and the orthogonal the demonstrated the
       highest emission was reported.
       All Fundamental and Harmonics were tested for peak emissions and compared to the
       Average limits as this is a CW signal. As the CW complies with the average limits it also
       complies with the peak limits of part 15.35. All other spurious signals were tested using
       average or quasi-peak detectors as specified.
       In accordance with FCC part15.209 (d) emissions in the bands 9-90 kHz and 110-490 kHz
       are performed using an average detector. All other readings below 1000MHz were taken
       with a quasi-peak detector.
       Resolution bandwidths used for frequencies measured between:
           9 kHz – 150kHz,         RBW = 200Hz
           150kHz – 30MHz,         RBW = 9kHz
           30MHz – 1GHz,           RBW = 120kHz

       And, for frequencies measured above 1GHz:
           RBW = 1MHz




WLL Report #13305-01 Rev 1                        - 9 of 14-          © 2015 Washington Laboratories, Ltd.


            Frederick Energy Products LLC                                                FCC/IC Certification Test Report
            Magnetic Field Generator w CAM                                                               February , 2014




                                    Table 8: Radiated Emissions Test Data < 30MHz
                                                              Corr          Corr.     Corr.
Frequency     Polarity   Azimuth        Ant.      SA Level                                         Limit       Margin
                                                             Factors        Level     Level                                 Comments
  (MHz)        H/V       (Degree)    Height (m)    (dBuV)                                         (uV/m)        (dB)
                                                              (dB)         (uV/m)   (dBuV/m)

 0.073          X          90.00       1.00        59.35      11.8         3628.2    71.2       11665.10        -10.1       Peak
 0.073          Y          45.00       1.00        61.12      11.8         4448.3    73.0       11665.10         -8.4       Peak
 0.073          Z         270.00       1.00        55.16      11.8         2239.7    67.0       11665.10        -14.3

 0.146          X         45.00        1.00        42.54      11.5         501.2     54.0        5832.55        -21.3       Peak
 0.146          Y         90.00        1.00        47.25      11.5         862.0     58.7        5832.55        -16.6
 0.146          Z         45.00        1.00        46.86      11.5         824.2     58.3        5832.55        -17.0

 0.219          X          45.00       1.00        41.50      11.4         440.8     52.9        3888.37        -18.9       Peak
 0.219          Y         270.00       1.00        45.86      11.4         728.1     57.2        3888.37        -14.6
 0.219          Z         190.00       1.00        42.25      11.4         480.5     53.6        3888.37        -18.2

 0.292          X         90.00        1.00        38.35      11.3         305.1     49.7        2916.27        -19.6       Peak
 0.292          Y         90.00        1.00        42.20      11.3         475.3     53.5        2916.27        -15.8
 0.292          Z         45.00        1.00        40.40      11.3         386.3     51.7        2916.27        -17.6

                                                                                                                            Restricted
                                                                                                                            band
 0.110          X         90.00        1.00        41.40      11.5         442.4     52.9        7741.38        -24.9       edge
 0.110          Y         90.00        1.00        42.10      11.5         479.5     53.6        7741.38        -24.2
 0.110          Z         45.00        1.00        41.62      11.5         453.8     53.1        7741.38        -24.6
      No other harmonic or spurious emissions were detectable below 30MHz
      Note: Since the peak readings are below the applicable 15.209 average limits and the transmit
      occupied bandwidth is non-existent the peak measurements do not exceed the part 15.35 limit
      (average limit plus 20dB). Therefore the unit was not tested using an average detector in these (*)
      ranges and is assumed to comply with the peak and average requirements.




      WLL Report #13305-01 Rev 1                                 - 10 of 14-             © 2015 Washington Laboratories, Ltd.


    Frederick Energy Products LLC                                                      FCC/IC Certification Test Report
    Magnetic Field Generator w CAM                                                                     February , 2014



                 Table 9: Radiated Emissions Test Data > 30MHz (TX and RCV)
                                                                     Corr      Corr.
 Frequency    Polarity       Azimuth       Ant.      SA Level                              Limit       Margin
                                                                    Factors    Level                               Comments
   (MHz)       H/V           (Degree)   Height (m)    (dBuV)                              (uV/m)        (dB)
                                                                     (dB)     (uV/m)

   44.55        V            190.00       1.45        25.13           13.0     81.0       100.0          -1.8      qp
   50.93        V             90.00       1.00        26.30            9.9     64.7       100.0          -3.8      qp
   57.09        V            290.00       1.65        20.30            9.4     30.6       100.0         -10.3      qp
   65.35        V            180.00       1.21        24.50           10.5     55.9       100.0          -5.0      qp
   78.93        V            190.00       1.45        26.15           10.8     70.0       100.0          -3.1      qp
  108.73        V            270.00       1.70        12.54           15.4     25.0       150.0         -15.6      qp
  129.53        V            190.00       1.85        20.41           17.3     77.2       150.0          -5.8      qp
  148.80        V            180.00       1.54        20.46           15.9     65.6       150.0          -7.2      qp
  163.60        V            170.00       1.26        22.71           15.8     84.4       150.0          -5.0      qp
  183.15        V            180.00       1.84        20.17           15.3     59.1       150.0          -8.1      qp
  208.75        V            180.00       2.18        16.51           15.0     37.5       150.0         -12.0      qp
  224.78        V              0.00       1.80        15.85           15.4     36.5       200.0         -14.8      qp
  258.20        V            180.00       1.50        18.90           16.8     61.2       200.0         -10.3      qp
  337.33        V            180.00       1.50        23.78           19.5    146.7       200.0          -2.7      qp
  461.28        V            190.00       1.99        10.18           23.6     48.7       200.0         -12.3      qp
  520.73        V            150.00       2.20        13.25           25.4     85.1       200.0          -7.4      qp

   44.55        H            270.00       4.00        22.50           13.0    59.9        100.0          -4.5      qp
   50.93        H            280.00       3.86        25.60            9.9    59.7        100.0          -4.5      qp
   57.09        H            270.00       3.90        22.40            9.4    38.9        100.0          -8.2      qp
   65.35        H            180.00       3.59        27.30           10.5    77.2        100.0          -2.2      qp
   78.93        H            180.00       3.50        27.50           10.8    81.8        100.0          -1.7      qp
  108.73        H            190.00       3.60        16.65           15.4    40.1        150.0         -11.5      qp
  129.53        H             90.00       2.60        15.11           17.3    41.9        150.0         -11.1      qp
  148.80        H            180.00       2.76        18.53           15.9    52.5        150.0          -9.1      qp
  163.60        H            190.00       3.00        14.92           15.8    34.4        150.0         -12.8      qp
  183.15        H             90.00       2.00        16.24           15.3    37.6        150.0         -12.0      qp
  208.75        H             90.00       1.87        20.20           15.0    57.4        150.0          -8.4      qp
  224.78        H             90.00       1.62        13.73           15.4    28.6        200.0         -16.9      qp
  258.20        H            180.00       1.50        20.50           16.8    73.6        200.0          -8.7      qp
  337.33        H            180.00       1.50        15.60           19.5    57.2        200.0         -10.9      qp
  461.28        H            180.00       1.93        13.80           23.6    73.9        200.0          -8.6      qp
  520.73        H              0.00       0.00         9.75           25.4    56.9        200.0         -10.9      qp
qp indicates the use of the Quasi-peak detector. If not indicated peak detector was used.




WLL Report #13305-01 Rev 1                                      - 11 of 14-            © 2015 Washington Laboratories, Ltd.


      Frederick Energy Products LLC                                   FCC/IC Certification Test Report
      Magnetic Field Generator w CAM                                                  February , 2014



4.3     Receiver Radiated Emissions (RSS-210 sect 2.5, RSS-GEN sect 6.1)
4.3.1 Requirements
          Test Arrangement: Table Top
          Compliance Standard: RSS-Gen sect 6.1
                                 RSS-Gen Compliance Limits for Receivers
                       Frequency                                       Limits
                       30-88 MHz                                     100 µV/m
                      88-216 MHz                                     150 µV/m
                     216-960 MHz                                     200 µV/m
                        >960MHz                                      500 µV/m


4.3.2 Test Procedure
          The requirements of RSS-GEN call for the EUT to be placed on an 80 cm high 1 X 1.5
          meters non-conductive motorized turntable for radiated testing on a 3-meter open field
          test site. The emissions from the EUT were measured continuously at every azimuth by
          rotating the turntable. Bi-conical and log periodic broadband antennas were mounted on
          an antenna mast to determine the height of maximum emissions. The height of the
          antenna was varied between 1 and 4 meters. The output of the antenna was connected to
          the input of the spectrum analyzer and the emissions in the frequency range of 30 MHz to
          3 GHz were measured. Cables were varied in position to produce maximum emissions.
          Both the horizontal and vertical field components were measured.
          The output from the antenna was connected, via a preamplifier, to the input of the
          spectrum analyzer. The detector function was set to quasi-peak, peak, or average as
          appropriate. The measurement bandwidth of the spectrum analyzer system was set to at
          least 120 kHz, with all post-detector filtering no less than 10 times the measurement
          bandwidth.
          All measurements above 1GHz were made at a distance of 3m with a Resolution
          Bandwidth of 1MHz and a Video bandwidth of 10Hz. Average readings were taken in a
          linear mode with zero-span.
4.3.3 Test Data
          The EUT complies with the requirements of RSS 210 (RSS-GEN limits) as shown in
          Table 10.




WLL Report #13305-01 Rev 1                          - 12 of 14-       © 2015 Washington Laboratories, Ltd.


    Frederick Energy Products LLC                                       FCC/IC Certification Test Report
    Magnetic Field Generator w CAM                                                      February , 2014



4.3.4 Radiated Data Reduction and Reporting
         To convert the raw spectrum analyzer radiated data into a form that can be compared with
         the FCC limits, it is necessary to account for various calibration factors that are supplied
         with the antennas and other measurement accessories. These factors are included into the
         antenna factor (AF) column of the table and in the cable factor (CF) column of the table.
         The AF (in dB/m) and the CF (in dB) is algebraically added to the raw Spectrum
         Analyzer Voltage in dBµV to obtain the Radiated Electric Field in dBµV/m. This
         logarithm amplitude is converted to linear amplitude, and then compared to the Industry
         Canada limit.
         Example:
         Spectrum Analyzer Voltage:            VdBµV
         Antenna Correction Factor:            AFdB/m
         Cable Correction Factor:              CFdB
         Electric Field:                                         EdBV/m =      V dBµV + AFdB/m +
         CFdB
         To convert to linear units of measure: EdBV/m/20 Inv log




WLL Report #13305-01 Rev 1                         - 13 of 14-          © 2015 Washington Laboratories, Ltd.


    Frederick Energy Products LLC                                                      FCC/IC Certification Test Report
    Magnetic Field Generator w CAM                                                                     February , 2014




             Table 10: Receiver Radiated Emissions Test Data > 30MHz (TX and RCV)
                                                                     Corr      Corr.
 Frequency     Polarity      Azimuth       Ant.      SA Level                              Limit       Margin
                                                                    Factors    Level                               Comments
   (MHz)        H/V          (Degree)   Height (m)    (dBuV)                              (uV/m)        (dB)
                                                                     (dB)     (uV/m)

   44.55         V           190.00       1.45        25.13           13.0     81.0       100.0          -1.8      qp
   50.93         V            90.00       1.00        26.30            9.9     64.7       100.0          -3.8      qp
   57.09         V           290.00       1.65        20.30            9.4     30.6       100.0         -10.3      qp
   65.35         V           180.00       1.21        24.50           10.5     55.9       100.0          -5.0      qp
   78.93         V           190.00       1.45        26.15           10.8     70.0       100.0          -3.1      qp
  108.73         V           270.00       1.70        12.54           15.4     25.0       150.0         -15.6      qp
  129.53         V           190.00       1.85        20.41           17.3     77.2       150.0          -5.8      qp
  148.80         V           180.00       1.54        20.46           15.9     65.6       150.0          -7.2      qp
  163.60         V           170.00       1.26        22.71           15.8     84.4       150.0          -5.0      qp
  183.15         V           180.00       1.84        20.17           15.3     59.1       150.0          -8.1      qp
  208.75         V           180.00       2.18        16.51           15.0     37.5       150.0         -12.0      qp
  224.78         V             0.00       1.80        15.85           15.4     36.5       200.0         -14.8      qp
  258.20         V           180.00       1.50        18.90           16.8     61.2       200.0         -10.3      qp
  337.33         V           180.00       1.50        23.78           19.5    146.7       200.0          -2.7      qp
  461.28         V           190.00       1.99        10.18           23.6     48.7       200.0         -12.3      qp
  520.73         V           150.00       2.20        13.25           25.4     85.1       200.0          -7.4      qp

   44.55         H           270.00       4.00        22.50           13.0    59.9        100.0          -4.5      qp
   50.93         H           280.00       3.86        25.60            9.9    59.7        100.0          -4.5      qp
   57.09         H           270.00       3.90        22.40            9.4    38.9        100.0          -8.2      qp
   65.35         H           180.00       3.59        27.30           10.5    77.2        100.0          -2.2      qp
   78.93         H           180.00       3.50        27.50           10.8    81.8        100.0          -1.7      qp
  108.73         H           190.00       3.60        16.65           15.4    40.1        150.0         -11.5      qp
  129.53         H            90.00       2.60        15.11           17.3    41.9        150.0         -11.1      qp
  148.80         H           180.00       2.76        18.53           15.9    52.5        150.0          -9.1      qp
  163.60         H           190.00       3.00        14.92           15.8    34.4        150.0         -12.8      qp
  183.15         H            90.00       2.00        16.24           15.3    37.6        150.0         -12.0      qp
  208.75         H            90.00       1.87        20.20           15.0    57.4        150.0          -8.4      qp
  224.78         H            90.00       1.62        13.73           15.4    28.6        200.0         -16.9      qp
  258.20         H           180.00       1.50        20.50           16.8    73.6        200.0          -8.7      qp
  337.33         H           180.00       1.50        15.60           19.5    57.2        200.0         -10.9      qp
  461.28         H           180.00       1.93        13.80           23.6    73.9        200.0          -8.6      qp
  520.73         H             0.00       0.00         9.75           25.4    56.9        200.0         -10.9      qp
qp indicates the use of the Quasi-peak detector. If not indicated peak detector was used.




WLL Report #13305-01 Rev 1                                      - 14 of 14-            © 2015 Washington Laboratories, Ltd.



Document Created: 2015-01-19 23:39:25
Document Modified: 2015-01-19 23:39:25

© 2024 FCC.report