RF Exposure Report

FCC ID: QTG-ZKPIB

RF Exposure Info

Download: PDF
FCCID_4244587

                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                  1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District,
                                  Shenzhen, China
                                  Telephone:     +86-755-26648640
                                  Fax:           +86-755-26648637                 Report Template Version: V03
                                  Website:       www.cqa-cert.com                 Report Template Revision Date: Mar.1st, 2017



                RF Exposure Evaluation Report
Report No. :                      CQASZ20190400219E-02
Applicant:                        ZAGG Inc.
Address of Applicant:             910 West Legacy Center Way, Midvale, Utah 84047, USA
Manufacturer:                     ZAGG Inc.
Address of Manufacturer:          910 West Legacy Center Way, Midvale, Utah 84047, USA
Factory:                          ZAGG Inc.
Address of Factory:               910 West Legacy Center Way, Midvale, Utah 84047, USA
Equipment Under Test (EUT):
Product:                          Keyboard
Model No.:                        ZKB11RTB41
Brand Name:                       N/A

FCC ID:                           QTG-ZKPIB
Standards:                        47 CFR Part 1.1307
                                  47 CFR Part 2.1093
                                  KDB447498D01 General RF Exposure Guidance v06

Date of Test:                     2019-04-04 to 2019-04-09
Date of Issue:                    2019-04-09
Test Result :                     PASS*




Tested By:
                                                (Daisy Qin)


Reviewed By:
                                                (Aaron Ma )


Approved By:
                                                 ( Jack Ai)




* In the configuration tested, the EUT complied with the standards specified above.

The test report is effective only with both signature and specialized stamp, The result(s) shown in this report refer only to

the sample(s) tested. Without written approval of CQA, this report can’t be reproduced except in full.


                                    Shenzhen Huaxia Testing Technology Co., Ltd
                                                       Report No.: CQASZ20190400219E-02


1   Version
                            Revision History Of Report

          Report No.          Version        Description            Issue Date
     CQASZ20190400219E-02     Rev.01         Initial report         2019-04-09




                              Page:2 of 6


                                                                           Shenzhen Huaxia Testing Technology Co., Ltd
                                                                                                           Report No.: CQASZ20190400219E-02



2         Contents
                                                                                                                                                            Page
1       VERSION ...................................................................................................................................................... 2

2       CONTENTS .................................................................................................................................................. 3

3       GENERAL INFORMATION .......................................................................................................................... 4
    3.1     CLIENT INFORMATION.................................................................................................................................. 4
    3.2     GENERAL DESCRIPTION OF EUT ................................................................................................................. 4
4       SAR EVALUATION ...................................................................................................................................... 5
    4.1 RF EXPOSURE COMPLIANCE REQUIREMENT ................................................................................................ 5
       4.1.1 Standard Requirement ..................................................................................................................... 5
       4.1.2 Limits ................................................................................................................................................ 5
       4.1.3 EUT RF Exposure ............................................................................................................................ 6




                                                                Page:3 of 6


                                                Shenzhen Huaxia Testing Technology Co., Ltd
                                                                   Report No.: CQASZ20190400219E-02



3    General Information
3.1 Client Information
     Applicant:                 ZAGG Inc.
     Address of Applicant:      910 West Legacy Center Way, Midvale, Utah 84047, USA
     Manufacturer:              ZAGG Inc.
     Address of Manufacturer:   910 West Legacy Center Way, Midvale, Utah 84047, USA
     Factory:                   ZAGG Inc.
     Address of Factory:        910 West Legacy Center Way, Midvale, Utah 84047, USA

3.2 General Description of EUT
    Product Name:                 Keyboard
    Model No.:                    ZKB11RTB41
    Trade Mark:                   N/A
    Hardware Version:             V1.0
    Software Version:             V1.0
    Operation Frequency:          2402MHz~2480MHz
    Bluetooth Version:            V4.2
    Modulation Type:              GFSK
    Transfer Rate:                1Mbps
    Number of Channel:            40
    Product Type:                      Mobile          Portable   Fix Location
    Test Software of EUT:         Pixart BLE Tool v 1.0.10 (manufacturer declare )
    Antenna Type:                 PCB antenna
    Antenna Gain:                 0dBi
    EUT Power Supply:             lithium battery:DC3.7V, Charge by DC5.0V




                                         Page:4 of 6


                                                Shenzhen Huaxia Testing Technology Co., Ltd
                                                                     Report No.: CQASZ20190400219E-02



4    SAR Evaluation
4.1 RF Exposure Compliance Requirement
4.1.1 Standard Requirement
     According to KDB447498D01 General RF Exposure Guidance v06
     4.3.1. Standalone SAR test exclusion considerations
            Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head
     or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement
     or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition,
     listed below, is satisfied.
4.1.2 Limits
     The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
     ≤ 50 mm are determined by:

     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
     [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where

      f(G Hz) is the RF cha nne l tra ns m it fre que ncy in G Hz
                                                                                                   17
      P owe r a nd dis ta nce a re rounde d to the ne a re s t m W a nd m m be fore ca lcula tion
      The re s ult is rounded to one decimal place for comparison
     The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
     for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
     distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion




                                         Page:5 of 6


                                                 Shenzhen Huaxia Testing Technology Co., Ltd
                                                                       Report No.: CQASZ20190400219E-02




4.1.3 EUT RF Exposure
1) For BLE
Measurement Data
                                               GFSK mode
                                                       Tune up tolerance             Maximum tune-up Power
       Test channel              Peak Output Power
                                      (dBm)                      (dBm)                (dBm)        (mW)

    Lowest(2402MHz)                    0.86                       1±1                    2         1.585
     Middle(2441MHz)                   1.16                       1±1                    2         1.585
    Highest(2480MHz)                   0.55                       1±1                    2         1.585


  Worst case: GFSK
                       Maximum                         Maximum tune-
                         Peak           Tune up             up Power
                                                                            Calculated        Exclusion
     Channel           Conducted        tolerance
                                                                              value           threshold
                      Output Power       (dBm)         (dBm)     (mW)
                         (dBm)
      Lowest
    (2402MHz)             0.86            1±1               2    1.585        0.49

      Middle
                                                                                                 3.0
    (2440MHz)             1.16            1±1               2    1.585        0.50

      Highest
    (2480MHz)             0.55            1±1               2    1.585        0.50

  Conclusion: the calculated value ≤3.0, SAR is exempted.

Remark: The Max Conducted Peak Output Power data refer to report Report No.: CQASZ20190400219E-01




                                         Page:6 of 6



Document Created: 2019-04-17 10:37:42
Document Modified: 2019-04-17 10:37:42

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC