RF Exposure

FCC ID: QTG-IAIYPRO

RF Exposure Info

Download: PDF
FCCID_3854155

                                  Shenzhen Huaxia Testing Technology Co., Ltd
                                  1F., Block A of Tongsheng Technology Building, Huahui Road, Dalang Street, Longhua District,
                                  Shenzhen, China
                 ‘all
                                  Telephone:     +86—755—26648640

   1E E)6 :0                      Fax:
                                  Website:
                                                 +86—755—26648637
                                                 www.cga—cert.com
                                                                                   Report Template Version: VO3
                                                                                   Report Template Revision Date: Mar.1st, 2017



                 RF Exposure Evaluation Report

Report No. :                    CQASZ20180400005EW—02

Applicant:                      ZAGG Inc.

Address of Applicant:           910 West Legacy Center Way, Suite 500 Midvale, Utah 84047, USA
Manufacturer:                   ZAGG Inc.

Address of                      910 West Legacy Center Way, Suite 500 Midvale, Utah 84047, USA
Manufacturer:
Factory:                        Dongguan Kailai Eletronic Co.,Ltd.
Address of Factory:             Daditang Industrial Zone, Sukeng,Changping Town,Dongguan City, Guangdong,
                                China

Equipment Under Test (EUT):
Product:                 IFROGZ Sound Hub Pro
Model No.:               IFIEPH29
Brand Name:                     ifrogz
FCC ID:                         QTG—IAIYPRO
Standards:                      47 CFR Part 1.1307
                                47 CFR Part 2.1093
                                KDB447498D01 General RF Exposure Guidance v06

Date of Test:                   2018—04—10 2018—04—14
Date of Issue:                  2018—04—14
 Test Result :                  PASS*®


Tested By:
                                         Joxt00 @
                                                (Aaron Ma)


Reviewed By:                             ie 2hou
                                                    wen Zhou)


Approved By:

                                                 ( Jack Ai)




* In the contfiguration tested, the EUT complied with the standards specified above.

The test reportis effective only with both signature and specialized stamp, The result(s) shown in this report refer only to

the sample(s) tested. Without written approval of CQA, this report can‘t be reproduced except in full.


                                    Shenzhen Huaxia Testing Technology Co., Ltd
                                                   Report No.: CQASZ20180400005EW-02


2   Version
                            Revision History Of Report

          Report No.          Version         Description         Issue Date
    CQASZ20180400005EW-02     Rev.01         Initial report       2018-04-14




                              Page:2 of 6


                                                                                 Shenzhen Huaxia Testing Technology Co., Ltd
                                                                                                                Report No.: CQASZ20180400005EW-02



3         Contents
                                                                                                                                                                         Page
1       COVER PAGE .............................................................................................................................................................1

2       VERSION .....................................................................................................................................................................2

3       CONTENTS .................................................................................................................................................................3

4       GENERAL INFORMATION .......................................................................................................................................4
    4.1     CLIENT INFORMATION................................................................................................................................................4
    4.2     GENERAL DESCRIPTION OF EUT ................................................................................................................................4
5       SAR EVALUATION ....................................................................................................................................................5
    5.1 RF EXPOSURE COMPLIANCE REQUIREMENT ..............................................................................................................5
       5.1.1 Standard Requirement .................................................................................................................................5
       5.1.2 Limits ..............................................................................................................................................................5
       5.1.3 EUT RF Exposure .........................................................................................................................................5




                                                                     Page:3 of 6


                                               Shenzhen Huaxia Testing Technology Co., Ltd
                                                                 Report No.: CQASZ20180400005EW-02



4    General Information
4.1 Client Information
     Applicant:                 ZAGG Inc.
     Address of Applicant:      910 West Legacy Center Way, Suite 500 Midvale, Utah 84047, USA
     Manufacturer:              ZAGG Inc.
     Address of Manufacturer:   910 West Legacy Center Way, Suite 500 Midvale, Utah 84047, USA
     Factory:                   Dongguan Kailai Eletronic Co.,Ltd.
     Address of Factory:        Daditang Industrial Zone, Sukeng, Changping Town,Dongguan City,
                                Guangdong, China

4.2 General Description of EUT
    Product Name:               IFROGZ Sound Hub Pro
    Model No.:                  IFIEPH29
    Trade Mark:                 ifrogz
    Hardware Version:           V1.0
    Software Version:           V1.0
    Operation Frequency:        2402MHz~2480MHz
    Bluetooth Version:          V4.1
    Modulation Technique:       Frequency Hopping Spread Spectrum(FHSS)
    Modulation Type:            GFSK, π/4DQPSK, 8DPSK
    Number of Channel:          79
    Hopping Channel Type:       Adaptive Frequency Hopping systems
    Sample Type:                portable production
    Test Software of EUT:       Blue test 3(manufacturer declare )
    Antenna Type:               Ceramic antenna
    Antenna Gain:               0dBi
    Power Supply:               lithium battery:DC3.7V, Charge by DC5.0V




                                         Page:4 of 6


                                                Shenzhen Huaxia Testing Technology Co., Ltd
                                                                   Report No.: CQASZ20180400005EW-02



5    SAR Evaluation
5.1 RF Exposure Compliance Requirement
5.1.1 Standard Requirement
     According to KDB447498D01 General RF Exposure Guidance v06
     4.3.1. Standalone SAR test exclusion considerations
            Unless specifically required by the published RF exposure KDB procedures, standalone 1-g head
     or body and 10-g extremity SAR evaluation for general population exposure conditions, by measurement
     or numerical simulation, is not required when the corresponding SAR Exclusion Threshold condition,
     listed below, is satisfied.
5.1.2 Limits
     The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
     ≤ 50 mm are determined by:

     [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·
     [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where

                                                                                     17

                                   e decimal place for comparison
     The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and
     for transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation
     distance is < 5 mm, a distance of 5 mm is applied to determine SAR test exclusion
5.1.3 EUT RF Exposure




                                         Page:5 of 6


CQA                                             Shenzhen Huaxia Testing Technology Co., Ltd

LE E ;E ;“                                                       Report No.: CQASZ20180400005EW—02


   For BT:

  Measurement Data
                                                GESK mode
               Test channel                                 Peak Output Power (dBm)
                 Lowest                                                2450
                  Middle                                               4.320

                 Highest                                               4.160

                                          T/ADQPSK mode
               Test channel                                 Peak Output Power (dBm)

                 Lowest                                                0.150
                  Middle                                               2.220

                 Highest                                               2.090

                                            8BDPSK mode
               Test channel                                 Peak Output Power (dBm)
                 Lowest                                                0.590
                  Middle                                               2.750

                 Highest                                               2490


   The Max Conducted Peak Output Power is 4.32dBm in middle channel{2.441GHz);
   The best case gain of the antenna is OdBi.
   EIRP= 4.32dBm + OdBi = 4.32dBm
   4.32dBm logarithmic terms convert to numeric result is nearly 2.7mW
   According to the formula. calculate the EIRP test result:
  [{max. power of channel, including tune—up tolerance, mW)/{min. test separation distance, mm)] —
   [Nf(GHz)]
   General RF Exposure = (2.7mW /5 mm ) x \2.441GHz =0.84 D
   SAR requirement:
   S= 3.0                                                         @;
   0 <@.
   So the SAR report is not required.
   Remark: The Max Conducted Peak Output Power data refer to report Report No.:
   CQASZ20180400005EW—01




                                        Page:6 of 6



Document Created: 2018-05-11 17:13:56
Document Modified: 2018-05-11 17:13:56

© 2024 FCC.report