FCC ID: QQX-CAP8

RF Exposure Info

Download: PDF
FCCID_1364050

Calibration Laboratory of                                                                                          Schweizerischer Kalibrierdienst
Schmid & Partner                                                                                                   Service suisse d‘étalonnage
  Engineering AG                                                                                                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                                                                       Swiss Calibration Service



Accredited by the Swiss Accreditation Service (SAS)                                              Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreementfor the recognition of calibration certificates

                                                                                                 CertificateNo: D1900V2—5d056—Nov08




                                       D1900V2 — SN: 50056                    _

 Calibration procedure(s)              aacaLEosv
                                       Calibrationprocedur


 Calibration date:                     November 18, 2008 _____

 Condition of the calibrated item      In Tolerance


 This calibration certificate documents the traceability to national standards, which realize the physicalunits of measurements (S1).
 The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.


 All calibrations have been conducted in the closed laboratory facility: environmenttemperature (22 + 3)°C and humidity < 70%.


 Calibration Equipment used (M&TE critical for calibration)


 Primary Standards                      ID #                       Cal Date (Calibrated by, Certificate No.)           Scheduled Calibration
 Power meter EPM—442A                   GB37480704                 08—Oct—08 (No. 217—00898)                           Oct—09
 Power sensor HP 8481A                  US37202783                 08—Oct—08 (No. 217—00898)                           Oct—09
 Reference 20 dB Attenuator             SN: 5086 (20g)            01—Jul—08 (No. 217—00864)                            Jul—09
 Type—N mismatch combination            SN: 5047.2 / 06327        01—Jul—08 (No. 217—00867)                            Jul—09
 Reference Probe ESSDV2                 SN: 3025                  28—Apr—08 (No. ES3—3025_Apr08)                       Apr—09
 DAE4                                   SN: 601                    14—Mar—08 (No. DAE4—601_Mar08)                      Mar—09

 Secondary Standards                    ID #                      Check Date (in house)                                Scheduled Check
 Power sensor HP 8481A                  MY41092317                 18—Oct—02 (in house check Oct—07)                   In house check: Oct—09
 RF generator R&S SMT—06                100005                    4—Aug—99 (in house check Oct—07)                     In house check: Oct—09
 Network Analyzer HP 8753E              US37390585 $4206          18—Oct—01 (in house check Oct—08)                    In house check: Oct—09




                                        Name                                                                            Signature
 Calibrated by:                         ClaudioLeubler                                                                    U /}Q\A



 Approved by:                           Katja Pokovic                                                                     >



                                                                                                                      Issued: November 18, 2008
 This calibration certificate shall not be reproduced except in full without written approval of the laboratory.



Certificate No: D1900V2—50056_NovO8                                   Page 1 of 9


Calibration Laboratory of                                     Nll/4
                                                             Q\\\_/ >          S   Schweizerischer Kalibrierdienst
Schmid & Partner                                            M                  C   Service suisse d‘étalonnage
  Engineering AG                                            CS g                   Servizio svizzero di taratura
Zeughausstrasse 43, 8004 Zurich, Switzerland                 */fi\\\\*          S   Swiss Calibration Service
                                                                "thilabs


Accredited by the Swiss Accreditation Service (SAS)                             Accreditation No.: SCS 108
The Swiss Accreditation Service is one of the signatories to the EA
Multilateral Agreement for the recognition of calibration certificates


Glossary:
TSL                          tissue simulating liquid
ConvF                        sensitivity in TSL / NORM x,y,z
N/A                          not applicable or not measured

Calibration is Performed According to the Following Standards:
   a) IEEE Std 1528—2003, "IEEE Recommended Practice for Determining the Peak Spatial—
      Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
      Communications Devices: Measurement Techniques", December 2003
   b) CENELEC EN 50361, "Basic standard for the measurement of Specific Absorption Rate
      related to human exposure to electromagnetic fields from mobile phones (300 MHz — 3 GHz),
      July 2001
      Federal Communications Commission Office of Engineering & Technology (FCC OET},
      "Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency
      Electromagnetic Fields; Additional Information for Evaluating Compliance of Mobile and
      Portable Devices with FCC Limits for Human Exposure to Radiofrequency Emissions",
      Supplement C (Edition 01—01) to Bulletin 65

Additional Documentation:
   d) DASY4/5 System Handbook
Methods Applied and Interpretation of Parameters:
     Measurement Conditions: Further details are available from the Validation Report at the end
         of the certificate. All figures stated in the certificate are valid at the frequency indicated.
         Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed
         point exactly below the center marking of the flat phantom section, with the arms oriented
         parallel to the body axis.
         Feed Point Impedance and Return Loss: These parameters are measured with the dipole
         positioned under the liquid filled phantom. The impedance stated is transformed from the
         measurement at the SMA connector to the feed point. The Return Loss ensures low
         reflected power. No uncertainty required.
         Electrical Delay: One—way delay between the SMA connector and the antenna feed point. No
         uncertainty required.
         SAR measured: SAR measured at the stated antenna input power.
         SAR normalized: SAR as measured, normalized to an input power of 1 W at the antenna
         connector.
         SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the
         nominal SAR result.




Certificate No: D1900V2—50056_NovO8                             Page 2 of 9


Measurement Conditions
    DASY system configuration, as far as not given on page 1.
      DASY Version                                              DASYS5                                  V5.0
      Extrapolation                                     Advanced Extrapolation
      Phantom                                         Modular Flat Phantom V5.0
      Distance Dipole Center— TSL                               10 mm                                with Spacer
      Zoom Scan Resolution                                dx, dy, dz =5 mm
      Frequency                                           1900 MHz + 1 MHz



Head TSL parameters
    The following parameters and calculations were applied.
                                                                Temperature           Permittivity        Conductivity
      Nominal Head TSL parameters                                     22.0 °C            40.0              1.40 mho/m
      Measured Head TSL parameters                              (22.0 £ 0.2) °C       38.9 +6 %         1.47 mho/m + 6 %
      Head TSL temperature during test                          (22.0 £ 0.2) °C           ———                   ————




SAR result with Head TSL

      SAR averaged over 1 cm‘ (1 g) of Head TSL                   condition
      SAR measured                                          250 mW input power                    10.3 mW /g

      SAR normalized                                          normalized to 1W                    41.2 mW /g
      SAR for nominal Head TSL parameters ‘                   normalized to 1W           39.6 mW / g £ 17.0 % (k=2)


      SAR averaged over 10 cm* (10 g) of Head TSL                Condition
      SAR measured                                         250 mW input power                     5.34 mW /g
      SAR normalized                                          normalized to 1W                    21. 4 mW /g
      SAR for nominal Head TSL parameters ‘                   normalized to 1W           20.9 mW / g £ 16.5 % (k=2)




‘ Correction to nominal TSL parameters according to d), chapter "SAR Sensitivities"

Certificate No: D1900V2—54056_NovO8                     Page 3 of 9


Body TSL parameters

     The following parameters and calculations were applied.
                                                                    Temperature       Permittivity        Conductivity
       Nominal Body TSL parameters                                       22.0 °C         53.3              1.52 mho/m
       Measured Body TSL parameters                                 (22.0 £ 0.2) °C   55.2 £ 6 %        1.55 mho/m + 6 %
       Body TSL temperature during test                             (22.0 £ 0.2) °C       ———                   ———



SAR result with Body TSL

       SAR averaged over 1 cm‘ (1 g) of Body TSL                     Condition
       SAR measured                                            250 mW input power                  10.3 mW /g
       SAR normalized                                            normalized to 1W                  41.2 mW /g
       SAR for nominal Body TSL parameters *                     normalized to 1W        41.6 mW / g + 17.0 % (k=2)

       SAR averaged over 10 cm* (10 g) of Body TSL                   condition
       SAR measured                                            250 mW input power                  5.46 mW /g
       SAR normalized                                            normalized to 1W                  21.8 mW /g
       SAR for nominal Body TSL parameters *                     normalized to 1W        22.1 mW / g + 16.5 % (k=2)




* Correction to nominal TSL parameters according to d), chapter "SAR Sensitivities"

Certificate No: D1900V2—50056_NovO8                        Page 4 of 9


Appendix

Antenna Parameters with Head TSL

      Impedance, transformed to feed point                                            50.7 Q + 3.7 jQ

      Return Loss                                                                        —28.5 dB


Antenna Parameters with Body TSL

      Impedance, transformed to feed point                                            47.5 Q + 6.7 jQ
      Return Loss                                                                        —22.7 dB



General Antenna Parameters and Design

      Electrical Delay (one direction)                                                    1.196 ns


After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
second arm of the dipole. The antenna is therefore short—circuited for DC—signals.
No excessive force must be applied to the dipole arms, because they might bend orthe soldered connections near the
feedpoint may be damaged.


Additional EUT Data

      Manufactured by                                                                     SPEAG
      Manufactured on                                                                 March 19, 2004




Certificate No: D1900V2—50056_NovO8                      Page 5 of 9


DASY5 Validation Report for Head TSL
                                                                                Date/Time: 14.11.2008 16:09:33

Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 1900 MHz; Type: D1900V2; Serial: D1900V2 — SN:50056

Communication System: CW; Frequency: 1900 MHz; Duty Cycle: 1: 1
Medium: HSL U1O BB
Medium parameters used: £= 1900 MHz; 0 = 1.47 mho/m; &, = 39; p = 1000 kg/m‘
Phantom section: Flat Section
Measurement Standard: DASYS (IEEE/IEC)

DASYS Configuration:
        Probe: ES3DV2 — SN3025; ConvF(4.9, 4.9, 4.9); Calibrated: 28.04.2008

        Sensor—Surface: 3.4mm (Mechanical Surface Detection)

        Electronics: DAE4 $n601; Calibrated: 14.03.2008

        Phantom: Flat Phantom 5.0 (front); Type: QDOOOPS0AA; Serial: 1001

        Measurement SW: DASYS, V5.0 Build 120; SEMCAD X Version 13.4 Build 45


Pin = 250 mWdip = 10 mm, scan at 3.4mm/Zoom Scan (dist=3.4mm, probe Odeg)
(7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 94.1 V/m; Power Drift = 0.045 dB
Peak SAR (extrapolated) = 19.2 W/kg
SAR(1 g) = 10.3 mW/g; SAR(10 g) = 5.34 mW/g
Maximum value of SAR (measured) = 12.4 mW/g




                                         0 dB = 12.4mW/g




Certificate No: D1900V2—54056_NovO8                        Page 6 of 9


Impedance Measurement Plot for Head TSL


                                                                          14 Now 2008    13:32:07
             si1     4 U oFs                       2.7168 o         311.34 pH           1 900.000 000 MHz


     *
                                                                                                            CH1 Markerns
     De l                                                                                                    1: 44.766 a
                                                                                                               ~14.883 a
     tor                                               &
                                                       ‘- /v
                                                               vee"               %
                                                                                                            1.90000 GHz
      °

                                                                             C


                                                      §\
     Avg                                                   ~
     16                                                        ts

         t

     CH2     $11     LOG       5 dB/REF —20   dB                      2:—298.526 dB     1 900.000 000 MHz




                                                                                                            CH2 Markers
                                                                                                            1:~19.678 dB
     tor                                                                                                    1.90000 GHz

                                                                      2
     Av
     16°

         t

                   START 1 600.000 080 MHz                                       STOP 2 100.000 000 MHz




Certificate No: D1900V2—50056_NovO8                            Page 7 of 9


DASY5 Validation Report for Body TSL
                                                                                Date/Time: 18.11.2008 10:48:40

Test Laboratory: SPEAG, Zurich, Switzerland

DUT: Dipole 1900 MHz; Type: D1900V2; Serial: D1900V2 — SN:50056

Communication System: CW; Frequency: 1900 MHz; Duty Cycle: 1: 1
Medium: MSL U1O BB
Medium parameters used: f= 1900 MHz; 0 = 1.55 mho/m; s, = 55.2; p = 1000 kg/m‘
Phantom section: Flat Section
Measurement Standard: DASYS (IEEE/IEC)

DASYS Configuration:
        Probe: ES3DV2 — SN3025; ConvF(4.5, 4.5, 4.5); Calibrated: 28.04.2008

        Sensor—Surface: 3.4mm (Mechanical Surface Detection)

        Electronics: DAE4 Sn601; Calibrated: 14.03.2008

        Phantom: Flat Phantom 5.0 (back); Type: QDOOOPS5OAA; Serial: 1002

        Measurement SW: DASYS, V5.0 Build 120; SEMCAD X Version 13.4 Build 45


Pin = 250 mW; dip = 10 mm, scan at 3.4mm 2/Zoom Scan (dist=3.4mm, probe Odeg)
(7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 92.6 V/m; Power Drift = 0.00498 dB
Peak SAR (extrapolated) = 18.4 W/kg
SAR(I g) = 10.3 mW/g; SAR(10 g) = 5.46 mW/g
Maximum value of SAR (measured) = 12.5 mW/g
                                  ah
                                  a




                                  zo




                                         0 dB = 12.5mW/g




Certificate No: D1900V2—5d056_NovO8                        Page 8 of 9


Impedance Measurement Plot for Body TSL



                                                                18 Nov 2008      10:27:51
     CHI sii        1 U FS          1: 47.467 a   6.7012 4   561.33 pH          1 900.000 000 MHz



     *

     De 1


     Cor                                                C




     CH2    $11     LO6       5 dB/REF —20 dB                  1:—22.692 48     1 900.000 800 MHz




     Cor



                                            o_A
     Av
     16"


                  START 1 700.000 00d MHz                                STOP 2 100.000 000 MHz




Certificate No: D1900V2—50056_NovO8                      Page 9 of 9