Maximum exposure limits from CFR 47, FCC Part 1.1310:

               Table 1—Limits for Maximum Permissible Exposure (MPE)

  Frequency        Electric field    Magnetic field       Power       Averaging
    range            strength           strength         density        time
    (MHz)              (V/m)              (A/m)         (mW/cm2)      (minutes)
                 (A) Limits for Occupational/Controlled Exposure
0.3-3.0                          614              1.63          *100            6
                                                                    2
3.0-30                        1842/f             4.89/f     *900/f              6
30-300                          61.4             0.163            1.0           6
300-1,500                                                      f/300            6
1,500-100,000                                                       5           6
            (B) Limits for General Population/Uncontrolled Exposure
0.3-1.34                         614              1.63          *100           30
                                                                    2
1.34-30                        824/f             2.19/f     *180/f             30
30-300                          27.5             0.073            0.2          30
300-1,500                                                    f/1500            30
1,500-100,000                                                     1.0          30


The power density is calculated as shown below:

       S = (P x G)/(4 x π x d^2) – used to calculate exposure at 20 cm

       d = √(S/(P x G) x 4 X π) – used to calculate minimum distance to meet limits

S= power density
P = transmitter conducted power (in mW)
G = antenna numeric gain
d = distance to radiation center




                                          Page 1 of 2


                                       Table 2 – Power Density Calculations

                                              Output
                                              Power +10%
                Antenna      Output           for               Power
 Frequency      Gain         power            tolerance         Density       Limit         Distance

 MHz         numerical mW                     mW             mW/cm^2    mW/cm^2
       902.3        1                 11.56           12.716  0.0025311   0.0602                  20
       908.6        1                 11.17           12.287  0.0024457   0.0606                  20
       914.9        1                 13.52           14.872  0.0029602   0.0610                  20




Note: This equipment is not intended to be operated by hand. It is expected that a 20cm
separation will be maintained at all times.

The EIRP values were calculated from the maximized field strength from all possible angles of the EUT.




                                                  Page 2 of 2