RF Exposure Info - SAR Report Appendix B - Plots

FCC ID: QOQWT41E

RF Exposure Info

Download: PDF
FCCID_1602102

Report No. M110841                                                                              Page 26 of 67




                        APPENDIX B PLOTS OF THE SAR MEASUREMENTS
Plots of the measured SAR distributions inside the phantom are given in this Appendix for all tested
configurations.

                              Table 19 2450 MHz SAR Measurement Plot Numbers


                        Test                                                 Plot    Test
                        Position                                             No.     Channel

                        Lap Held                                               1         40

                        Edge On Primary Landscape                              2         40

                        Edge On Primary Portrait                               3         40

                        Edge On Secondary Portrait                             4         40

                                                                               5         01
                        Edge On Secondary Landscape
                                                                               6         40
                                                                               7         79

                                   Table 20 2450MHz System verification Plot


               Plot 8                         System verification 2450 MHz 26 August 2011

               Plot 9                       System verification 2450 MHz 01 September 2011




                             Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                             measurement included in this document are traceable to Australian/national standards. NATA
                             is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                             equivalence of testing, calibration and inspection reports.
                             This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                           Page 27 of 67




Test Date: 26 August 2011
File Name: M110841 2450 MHz Bluetooth (DH5) Lap Held (DAE442 Probe1380) 26-08-11.da52:0
DUT: Handheld Group Tablet PC; Type: CC61; Serial: Pre-production sample

 * Communication System: Bluetooth 2.0 DH5; Frequency: 2441 MHz; Duty Cycle: 1:2.5704
 * Medium parameters used: f = 2440 MHz; σ = 1.961 mho/m; εr = 51.315; ρ = 1000 kg/m3
- Electronics: DAE3 Sn442; Probe: ET3DV6 - SN1380; ConvF(4.09, 4.09, 4.09)
- Phantom: Flat Phantom 10.1; Serial: P 10.1; Phantom section: Flat 2.2 Section

Configuration/Channel 40 Test/Area Scan (61x101x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (interpolated) = 0.046 mW/g

Configuration/Channel 40 Test/Zoom Scan (7x7x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 3.666 V/m; Power Drift = 0.18 dB
Peak SAR (extrapolated) = 0.088 W/kg
SAR(1 g) = 0.043 mW/g; SAR(10 g) = 0.024 mW/g
Maximum value of SAR (measured) = 0.047 mW/g




                 0 dB = 0.050mW/g
                                    SAR MEASUREMENT PLOT 1

Ambient Temperature                                      19.8 Degrees Celsius
Liquid Temperature                                       19.7 Degrees Celsius
Humidity                                                 48%




                          Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                          measurement included in this document are traceable to Australian/national standards. NATA
                          is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                          equivalence of testing, calibration and inspection reports.
                          This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                      Page 28 of 67




                     Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                     measurement included in this document are traceable to Australian/national standards. NATA
                     is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                     equivalence of testing, calibration and inspection reports.
                     This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                           Page 29 of 67




Test Date: 26 August 2011
File Name: M110841 2450 MHz Bluetooth (DH5) Primary Landscape (DAE442 Probe1380) 26-08-11.da52:0
DUT: Handheld Group Tablet PC; Type: CC61; Serial: Pre-production sample

 * Communication System: Bluetooth 2.0 DH5; Frequency: 2441 MHz; Duty Cycle: 1:2.5704
 * Medium parameters used: f = 2440 MHz; σ = 1.961 mho/m; εr = 51.315; ρ = 1000 kg/m3
- Electronics: DAE3 Sn442; Probe: ET3DV6 - SN1380; ConvF(4.09, 4.09, 4.09)
- Phantom: Flat Phantom 10.1; Serial: P 10.1; Phantom section: Flat 2.2 Section

Configuration/Channel 40 Test/Area Scan (61x181x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (interpolated) = 0.011 mW/g

Configuration/Channel 40 Test/Zoom Scan (8x9x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 1.568 V/m; Power Drift = -0.48 dB
Peak SAR (extrapolated) = 0.015 W/kg
SAR(1 g) = 0.00468 mW/g; SAR(10 g) = 0.00223 mW/g
Maximum value of SAR (measured) = 0.00528 mW/g




                 0 dB = 0.0053mW/g
                                  SAR MEASUREMENT PLOT 2

Ambient Temperature                                      19.8 Degrees Celsius
Liquid Temperature                                       19.7 Degrees Celsius
Humidity                                                 48%




                          Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                          measurement included in this document are traceable to Australian/national standards. NATA
                          is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                          equivalence of testing, calibration and inspection reports.
                          This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                      Page 30 of 67




                     Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                     measurement included in this document are traceable to Australian/national standards. NATA
                     is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                     equivalence of testing, calibration and inspection reports.
                     This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                           Page 31 of 67




Test Date: 26 August 2011
File Name: M110841 2450 MHz Bluetooth (DH5) Primary Portrait (DAE442 Probe1380) 26-08-11.da52:0
DUT: Handheld Group Tablet PC; Type: CC61; Serial: Pre-production sample

 * Communication System: Bluetooth 2.0 DH5; Frequency: 2441 MHz; Duty Cycle: 1:2.5704
 * Medium parameters used: f = 2440 MHz; σ = 1.961 mho/m; εr = 51.315; ρ = 1000 kg/m3
- Electronics: DAE3 Sn442; Probe: ET3DV6 - SN1380; ConvF(4.09, 4.09, 4.09)
- Phantom: Flat Phantom 10.1; Serial: P 10.1; Phantom section: Flat 2.2 Section

Configuration/Channel 40 Test/Area Scan (61x121x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (interpolated) = 0.00537 mW/g

Configuration/Channel 40 Test/Zoom Scan (7x8x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 1.133 V/m; Power Drift = -0.22 dB
Peak SAR (extrapolated) = 0.013 W/kg
SAR(1 g) = 0.00294 mW/g; SAR(10 g) = 0.00127 mW/g
Maximum value of SAR (measured) = 0.00372 mW/g




                 0 dB = 0.0037mW/g
                                  SAR MEASUREMENT PLOT 3

Ambient Temperature                                      19.8 Degrees Celsius
Liquid Temperature                                       19.7 Degrees Celsius
Humidity                                                 48%




                          Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                          measurement included in this document are traceable to Australian/national standards. NATA
                          is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                          equivalence of testing, calibration and inspection reports.
                          This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                      Page 32 of 67




                     Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                     measurement included in this document are traceable to Australian/national standards. NATA
                     is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                     equivalence of testing, calibration and inspection reports.
                     This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                           Page 33 of 67




Test Date: 26 August 2011
File Name: M110841 2450 MHz Bluetooth (DH5) Sec Portrait (DAE442 Probe1380) 26-08-11.da52:0
DUT: Handheld Group Tablet PC; Type: CC61; Serial: Pre-production sample

 * Communication System: Bluetooth 2.0 DH5; Frequency: 2441 MHz; Duty Cycle: 1:2.5704
 * Medium parameters used: f = 2440 MHz; σ = 1.961 mho/m; εr = 51.315; ρ = 1000 kg/m3
- Electronics: DAE3 Sn442; Probe: ET3DV6 - SN1380; ConvF(4.09, 4.09, 4.09)
- Phantom: Flat Phantom 10.1; Serial: P 10.1; Phantom section: Flat 2.2 Section

Configuration/Channel 40 Test/Area Scan (61x121x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (interpolated) = 0.052 mW/g

Configuration/Channel 40 Test/Zoom Scan (7x7x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 5.199 V/m; Power Drift = 0.16 dB
Peak SAR (extrapolated) = 0.110 W/kg
SAR(1 g) = 0.051 mW/g; SAR(10 g) = 0.028 mW/g
Maximum value of SAR (measured) = 0.055 mW/g




                 0 dB = 0.050mW/g
                                    SAR MEASUREMENT PLOT 4

Ambient Temperature                                      19.8 Degrees Celsius
Liquid Temperature                                       19.7 Degrees Celsius
Humidity                                                 48%




                          Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                          measurement included in this document are traceable to Australian/national standards. NATA
                          is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                          equivalence of testing, calibration and inspection reports.
                          This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                      Page 34 of 67




                     Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                     measurement included in this document are traceable to Australian/national standards. NATA
                     is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                     equivalence of testing, calibration and inspection reports.
                     This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                           Page 35 of 67




Test Date: 1 September 2011
File Name: M110841 2450 MHz Bluetooth (DH5) Sec Land -1.5dB (DAE442 Probe1380) 01-09-11.da52:0
DUT: Handheld Group Tablet PC; Type: CC61; Serial: Pre-production sample

 * Communication System: Bluetooth 2.0 DH5; Frequency: 2402 MHz; Duty Cycle: 1:2.5704
 * Medium parameters used: f = 2402 MHz; σ = 1.875 mho/m; εr = 51.341; ρ = 1000 kg/m3
- Electronics: DAE3 Sn442; Probe: ET3DV6 - SN1380; ConvF(4.09, 4.09, 4.09)
- Phantom: Flat Phantom 10.1; Serial: P 10.1; Phantom section: Flat 2.2 Section

Configuration/Channel 1 Test/Area Scan (61x101x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (interpolated) = 1.860 mW/g

Configuration/Channel 1 Test/Zoom Scan (7x7x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 6.926 V/m; Power Drift = -0.21 dB
Peak SAR (extrapolated) = 2.899 W/kg
SAR(1 g) = 1.13 mW/g; SAR(10 g) = 0.493 mW/g
Maximum value of SAR (measured) = 1.230 mW/g




                 0 dB = 1.230mW/g
                                    SAR MEASUREMENT PLOT 5

Ambient Temperature                                      20.5 Degrees Celsius
Liquid Temperature                                       20.3 Degrees Celsius
Humidity                                                 45%




                          Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                          measurement included in this document are traceable to Australian/national standards. NATA
                          is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                          equivalence of testing, calibration and inspection reports.
                          This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                      Page 36 of 67




                     Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                     measurement included in this document are traceable to Australian/national standards. NATA
                     is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                     equivalence of testing, calibration and inspection reports.
                     This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                           Page 37 of 67




Test Date: 26 August 2011
File Name: M110841 2450 MHz Bluetooth (DH5) Sec Landscape (DAE442 Probe1380) 26-08-11.da52:0
DUT: Handheld Group Tablet PC; Type: CC61; Serial: Pre-production sample

 * Communication System: Bluetooth 2.0 DH5; Frequency: 2441 MHz; Duty Cycle: 1:2.5704
 * Medium parameters used: f = 2440 MHz; σ = 1.961 mho/m; εr = 51.315; ρ = 1000 kg/m3
- Electronics: DAE3 Sn442; Probe: ET3DV6 - SN1380; ConvF(4.09, 4.09, 4.09)
- Phantom: Flat Phantom 10.1; Serial: P 10.1; Phantom section: Flat 2.2 Section

Configuration/Channel 40 Test/Area Scan (61x181x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (interpolated) = 2.035 mW/g

Configuration/Channel 40 Test/Zoom Scan (7x7x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 5.961 V/m; Power Drift = 0.0051 dB
Peak SAR (extrapolated) = 3.186 W/kg
SAR(1 g) = 1.21 mW/g; SAR(10 g) = 0.526 mW/g
Maximum value of SAR (measured) = 1.301 mW/g




                 0 dB = 1.300mW/g
                                    SAR MEASUREMENT PLOT 6

Ambient Temperature                                      19.8 Degrees Celsius
Liquid Temperature                                       19.7 Degrees Celsius
Humidity                                                 48%




                          Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                          measurement included in this document are traceable to Australian/national standards. NATA
                          is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                          equivalence of testing, calibration and inspection reports.
                          This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                      Page 38 of 67




                     Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                     measurement included in this document are traceable to Australian/national standards. NATA
                     is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                     equivalence of testing, calibration and inspection reports.
                     This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                           Page 39 of 67




Test Date: 1 September 2011
File Name: M110841 2450 MHz Bluetooth (DH5) Sec Land -1.5dB (DAE442 Probe1380) 01-09-11.da52:0
DUT: Handheld Group Tablet PC; Type: CC61; Serial: Pre-production sample

 * Communication System: Bluetooth 2.0 DH5; Frequency: 2480 MHz; Duty Cycle: 1:2.5704
 * Medium parameters used: f = 2480 MHz; σ = 1.993 mho/m; εr = 50.858; ρ = 1000 kg/m3
- Electronics: DAE3 Sn442; Probe: ET3DV6 - SN1380; ConvF(4.09, 4.09, 4.09)
- Phantom: Flat Phantom 10.1; Serial: P 10.1; Phantom section: Flat 2.2 Section

Configuration/Channel 79 Test/Area Scan (61x101x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (interpolated) = 1.866 mW/g

Configuration/Channel 79 Test/Zoom Scan (7x7x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 5.983 V/m; Power Drift = -0.37 dB
Peak SAR (extrapolated) = 3.136 W/kg
SAR(1 g) = 1.17 mW/g; SAR(10 g) = 0.503 mW/g
Maximum value of SAR (measured) = 1.324 mW/g




                 0 dB = 1.320mW/g
                                    SAR MEASUREMENT PLOT 7

Ambient Temperature                                      20.5 Degrees Celsius
Liquid Temperature                                       20.3 Degrees Celsius
Humidity                                                 45%




                          Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                          measurement included in this document are traceable to Australian/national standards. NATA
                          is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                          equivalence of testing, calibration and inspection reports.
                          This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                      Page 40 of 67




                     Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                     measurement included in this document are traceable to Australian/national standards. NATA
                     is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                     equivalence of testing, calibration and inspection reports.
                     This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                           Page 41 of 67




Test Date: 26 August 2011
File Name: M110841 System Check 2450 MHz 26-08-11.da52:0
DUT: Dipole 2450 MHz; Type: DV2450V2; Serial: 724

 * Communication System: CW; Frequency: 2450 MHz; Duty Cycle: 1:1
 * Medium parameters used: f = 2450 MHz; σ = 1.975 mho/m; εr = 51.251; ρ = 1000 kg/m3
- Electronics: DAE3 Sn442; Probe: ET3DV6 - SN1380; ConvF(4.09, 4.09, 4.09)
- Phantom: Flat Phantom 10.1; Serial: P 10.1; Phantom section: Flat 2.2 Section

Configuration/Channel 1 Test/Area Scan (51x51x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (interpolated) = 17.301 mW/g

Configuration/Channel 1 Test/Zoom Scan (7x7x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 88.196 V/m; Power Drift = -0.06 dB
Peak SAR (extrapolated) = 33.035 W/kg
SAR(1 g) = 14.8 mW/g; SAR(10 g) = 6.98 mW/g
Maximum value of SAR (measured) = 16.263 mW/g




                 0 dB = 16.260mW/g
                                  SAR MEASUREMENT PLOT 8

Ambient Temperature                                      19.8 Degrees Celsius
Liquid Temperature                                       19.7 Degrees Celsius
Humidity                                                 48%




                          Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                          measurement included in this document are traceable to Australian/national standards. NATA
                          is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                          equivalence of testing, calibration and inspection reports.
                          This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                      Page 42 of 67




                     Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                     measurement included in this document are traceable to Australian/national standards. NATA
                     is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                     equivalence of testing, calibration and inspection reports.
                     This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                           Page 43 of 67




Test Date: 1 September 2011
File Name: System Check 2450 MHz 01-09-11.da52:0
DUT: Dipole 2450 MHz; Type: DV2450V2; Serial: 724

 * Communication System: CW; Frequency: 2450 MHz; Duty Cycle: 1:1
 * Medium parameters used: f = 2450 MHz; σ = 1.949 mho/m; εr = 51.042; ρ = 1000 kg/m3
- Electronics: DAE3 Sn442; Probe: ET3DV6 - SN1380; ConvF(4.09, 4.09, 4.09)
- Phantom: Flat Phantom 10.1; Serial: P 10.1; Phantom section: Flat 2.2 Section

Configuration/Channel 1 Test/Area Scan (51x51x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (interpolated) = 16.898 mW/g

Configuration/Channel 1 Test/Zoom Scan (7x7x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 88.463 V/m; Power Drift = -0.13 dB
Peak SAR (extrapolated) = 32.484 W/kg
SAR(1 g) = 14.6 mW/g; SAR(10 g) = 6.88 mW/g
Maximum value of SAR (measured) = 16.120 mW/g




                 0 dB = 16.120mW/g
                                  SAR MEASUREMENT PLOT 9

Ambient Temperature                                      20.5 Degrees Celsius
Liquid Temperature                                       20.3 Degrees Celsius
Humidity                                                 45%




                          Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                          measurement included in this document are traceable to Australian/national standards. NATA
                          is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                          equivalence of testing, calibration and inspection reports.
                          This document shall only be reproduced in full, with the exception of the certificate on p3


Report No. M110841                                                                      Page 44 of 67




                     Accredited for compliance with ISO/IEC 17025. The results of the test, calibrations and/or
                     measurement included in this document are traceable to Australian/national standards. NATA
                     is a signatory to the ILAC Mutual Recognition Arrangement for the mutual recognition of the
                     equivalence of testing, calibration and inspection reports.
                     This document shall only be reproduced in full, with the exception of the certificate on p3



Document Created: 2011-12-12 07:47:32
Document Modified: 2011-12-12 07:47:32