Test Report

FCC ID: QOQWT41

Test Report

Download: PDF
FCCID_2506276

                                                   FCC ID: QOQWT41

                                     EMI − T E S T R E P O R T
                                                         - FCC Part 15.209 -



                                                                                                         14. October 2014
        Test Report No. :                           T38793-00-00JP                ______________________________________________________________________________________________

                                                                                                                  Date of issue




                  Type / Model Name                : WT41


                 Product Description               : Bluetooth module



                                Applicant          : MSC Technologies Systems GmbH

                                                     DC Augsburg

                                  Address          : August-Wessels-Str. 17

                                                     86156 Augsburg

                                                     GERMANY


                          Manufacturer             : BlueGiga Technologies Inc.

                                  Address          : Sinikalliontie 5A

                                                     FI-02630 Espoo

                                                     Finland



       Test Result according to the
       standards listed in clause 1 test                                       POSITIVE
       standards:




                                                               The test report merely corresponds to the test sample.
                                                               It is not permitted to copy extracts of these test results
                                                               without the written permission of the test laboratory.




CSA Group Bayern GmbH                                                               File No. T38793-00-00JP, page 1 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                                                                  Rev. No. 3.0, 2014-01-30


                                                   FCC ID: QOQWT41

                                                     Contents

       1     TEST ST AND ARDS                                                                         3



       2     SUMM ARY                                                                                 4



       3     EQUIPMENT UNDER TEST                                                                     5

       3.1     Photo documentation of the EUT                                                         5
       3.2     Power supply system utilised                                                           7
       3.3     Short description of the equipment under test (EUT)                                    7


       4     TEST ENVIRONMENT                                                                         8

       4.1     Address of the test laboratory                                                         8
       4.2     Environmental conditions                                                               8
       4.3     Statement of the measurement uncertainty                                               8
       4.4     Measurement protocol for FCC                                                           9


       5     TEST CONDITIONS AND RESULTS                                                           11

       5.1     Spurious emissions                                                                   11


       6     USED TEST EQUIPMENT AND ACCESSORIES                                                   17




CSA Group Bayern GmbH                                                File No. T38793-00-00JP, page 2 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                         Rev. No. 3.0, 2014-01-30


                                                   FCC ID: QOQWT41

1 TEST STANDARDS
The tests were performed according to following standards:

FCC Rules and Regulations Part 15, Subpart A - General (September, 2013)

FCC Rules and Regulations Part 15, Subpart C - Intentional Radiators (September, 2013)
Part 15, Subpart C, Section 15.209           Radiated emission limits, general requirements


ANSI C63.4: 2009                                    Methods of Measurement of Radio-Noise Emissions from Low-
                                                    Voltage Electrical and Electronic Equipment in the Range of 9 kHz
                                                    to 40 GHz.


ANSI C95.1: 2005                                    IEEE Standard for Safety Levels with respect to Human Exposure
                                                    to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz


CISPR 16-4-2: 2003                                  Uncertainty in EMC measurement


CISPR 22: 2005                                      Information technology equipment
 EN 55022: 2006




CSA Group Bayern GmbH                                                        File No. T38793-00-00JP, page 3 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                   Rev. No. 3.0, 2014-01-30


                                                          FCC ID: QOQWT41

2 SUMMARY

GENERAL REMARKS:
The testing is conducted on the combination of WT41 module and antenna WE-MCA to show compliance with the
radiated emission limits according to FCC Part 15.209 regarding the listing of the antenna in the module filling.

The frequency range from 30 MHz to 25GHz was scanned. The peripheral PCB motherboard is used to operate the
WT41 module as well as it is used as carrier board for the antenna WE-MCA.


FINAL ASSESSMENT:




Date of receipt of test sample                :    acc. to storage records


Testing commenced on                          :    30 September 2014


Testing concluded on                          :    01 October 2014




Checked by:                                                                  Tested by:

                          Klaus Gegenfurtner                                                      Jürgen Pessinger
                          I confirm the correctness and
                          Integrity of this documents                                             2014.10.14
                          2014.10.14 10:30:21 +02'00'                                             10:24:28 +02'00'
              Klaus Gegenfurtner                                                          Jürgen Pessinger
              Teamleader Radio




CSA Group Bayern GmbH                                                           File No. T38793-00-00JP, page 4 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                       Rev. No. 3.0, 2014-01-30


                                                   FCC ID: QOQWT41

3 EQUIPMENT UNDER TEST
3.1      Photo documentation of the EUT

WT41 module




Antenna WE-MCA




CSA Group Bayern GmbH                                                File No. T38793-00-00JP, page 5 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                         Rev. No. 3.0, 2014-01-30


                                                   FCC ID: QOQWT41




Periphery




CSA Group Bayern GmbH                                                File No. T38793-00-00JP, page 6 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                         Rev. No. 3.0, 2014-01-30


                                                   FCC ID: QOQWT41

3.2      Power supply system utilised

Power supply voltage:           :                  3.0 – 3.6 VDC (supplied via NT05 motherboard)


3.3      Short description of the equipment under test (EUT)
The EuT is a Bluetooth module for integration in several electronic products to add Bluetooth functionality to the
products.

Number of tested samples:             1
Serial number:                        none

EUT operation mode:
The equipment under test was operated during the measurement under the following conditions:

- TX mode CH low (2402MHz)

- TX mode CH mid (2441MHz)

- TX mode CH high (2480MHz)

EUT configuration:
(The CDF filled by the applicant can be viewed at the test laboratory.)

The following peripheral devices and interface cables were connected during the measurements:

-   Motherboard                                           Model : NT05 V41, MSC Technologies Systems GmbH

-   Antenna                                               Model : WE-MCA, Würth Elektronik eiSos GmbH

-   Laptop                                                Model : Tecra A2, Toshiba, CSA ID 01-01/01-05-005




CSA Group Bayern GmbH                                                         File No. T38793-00-00JP, page 7 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                    Rev. No. 3.0, 2014-01-30


                                                      FCC ID: QOQWT41

4 TEST ENVIRONMENT
4.1      Address of the test laboratory

            CSA Group Bayern GmbH
            Ohmstrasse 1-4
            94342 STRASSKIRCHEN
            GERMANY



4.2      Environmental conditions

During the measurement the environmental conditions were within the listed ranges:

Temperature:                                       15-35 ° C


Humidity:                                           30-60 %


Atmospheric pressure:                              86-106 kPa




4.3      Statement of the measurement uncertainty

The data and results referenced in this document are true and accurate. It is noted that the expanded
measurement uncertainty corresponds to the measurement results from the standard measurement uncertainty
multiplied by the coverage factor k = 2. The true value is located in the corresponding interval with a probability of
95 % The measurement uncertainty was calculated for all measurements listed in this test report acc. to CISPR
16-4-2 / 11.2003 „Uncertainties, statistics and limit modelling – Uncertainty in EMC measurements“ and is
documented in the quality system acc. to DIN EN ISO/IEC 17025. For all measurements shown in this report, the
measurement uncertainty of the test laboratory, CSA Group Bayern GmbH, is below the measurement uncertainty
as defined by CISPR. Therefore, no special measures must be taken into consideration with regard to the limits
according to CISPR. Furthermore, component and process variability of devices similar to that tested may result in
additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.




CSA Group Bayern GmbH                                                       File No. T38793-00-00JP, page 8 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                    Rev. No. 3.0, 2014-01-30


                                                   FCC ID: QOQWT41

4.4      Measurement protocol for FCC
4.4.1    GENERAL INFORMATION
 4.4.1.1     Test methodology

Conducted and radiated disturbance testing is performed according to the procedures set out by the International
Special Committee on Radio Interference (CISPR) Publication 22, European Standard EN 55022 as shown under
section 1 of this report.

 4.4.1.2     Justification

The equipment under test (EUT) is configured in a typical user arrangement in accordance with the manufacturer's
instructions. A cable is connected to each available port and either terminated with a peripheral using the
appropriate impedance characteristic or left unterminated. Where appropriate, cables are manually manipulated
with respect to each other thus obtaining maximum disturbances from the unit.

4.4.2    DETAILS OF TEST PROCEDURES

General Standard information

The test methods used comply with CISPR Publication 22, EN 55022 - " Information technology equipment - Radio
disturbance characteristics - Limits and methods of measurement" and with ANSI C63.4 - "Methods of
Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of
9 kHz to 40 GHz". In compliance with 47 CFR Part 15 Subpart A, Section 15.38 testing for FCC compliance may be
achieved by following the procedures set out in ANSI C63.4 and applying the CISPR 22 limits.

4.4.3    Conducted emission

The final level, expressed in dBV, is arrived at by taking the reading directly from the EMI receiver. This level is
compared directly to the FCC limit or to the CISPR limit.
To convert between dBV and V, the following conversions apply:

                                                       dBV = 20*log(V);
                                                       V = 10^(dBV/20);

Conducted emissions on the 50 Hz and/or 60 Hz power interface of the EUT are measured in the frequency range
of 150 kHz to 30 MHz. The measurements are performed using a receiver, which has CISPR characteristic
bandwidth and quasi-peak detection and a Line Impedance Stabilization Network (LISN) with 50/50 H
(CISPR 16) characteristics. Table top equipment is placed on a non-conducting table 80 centimetres above the floor
and is positioned 40 centimetres from the vertical ground plane (wall) of the screen room. If the minimum limit
margin of a peak mode measurement appears to be less than 20 dB, the emissions are remeasured using a tuned
receiver with quasi-peak and average detection and recorded on the data sheets.




CSA Group Bayern GmbH                                                       File No. T38793-00-00JP, page 9 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                  Rev. No. 3.0, 2014-01-30


                                                       FCC ID: QOQWT41


4.4.4    Radiated emission (electrical field 30 MHz - 1 GHz)

Spurious emissions from the EUT are measured in the frequency range of 30 MHz to 1000 MHz using a tuned
receiver and appropriate broadband linearly polarised antennas. Measurements between 30 MHz and 1000 MHz
are made with 120 kHz/6 dB bandwidth and quasi-peak detection. Table top equipment is placed on a 1.0 X 1.5 m
non-conducting table 80 centimetres above the ground plane. Floor standing equipment is placed directly on the
turntable/ground plane. The setup of the equipment under test is established in accordance with ANSI C63.4.The
interface cables that are closer than 40 centimetres to the ground plane are bundled in the center in a serpentine
fashion so that they are at least 40 centimetres from the ground plane. Cables to simulators/testers (if used in this
test) are routed through the center of the table and to a screened room located outside the test area. The antenna is
positioned 3, 10 or 30 meters horizontally from the EUT and is repeated vertically. To locate maximum emissions
from the test sample the antenna is varied in height from 1 to 4 meters and the EUT is rotated 360 degrees.
The final level in dBµV/m is calculated by taking the reading from the EMI receiver (Level dBµV) and adding the
correction factors and cable loss factor (dB). The FCC or CISPR limit is subtracted from this result in order to
provide the limit margin listed in the measurement protocol.

The resolution bandwidth setting:
30 MHz – 1000 MHz:           RBW: 120 kHz

Example:
           Frequency              Level            +    Factor   =    Level       -   CISPR Limit   =
           Delta
              (MHz)               (dBµV)                  (dB)       (dBµV/m)          (dBµV/m)       (dB)
              719.0               75.0             +      32.6   =   107.6    -        110.0        = -2.4

4.4.5    Radiated emission (electrical field 1 GHz - 40 GHz)

Radiated emissions from the EUT are measured in the frequency range 1 GHz up to the maximum frequency as
specified in 47 CFR Part 15, Subpart A, Section 15.33, using a spectrum analyser and appropriate linearly polarized
antennas. Table top equipment is placed on a 1.0 X 1.5 metre non-conducting table 80 centimetres above the
ground plane. Floor standing equipment is placed directly on the turntable/ground plane. The setup of the
equipment under test is following set out in ANSI C63.4. The interface cables that are closer than 40 centimetres to
the ground plane are bundled in the center in a serpentine fashion so they are at least 40 centimetres from the
ground plane. Cables to simulators/testers (if used in this test) are routed through the center of the table and to a
screened room located outside the test area. Measurements are made in both the horizontal and vertical
polarization planes in a fully anechoic room using a spectrum analyser set to max peak detector function and a
resolution 1 MHz and video bandwidth 3 MHz for peak and 10 Hz for average measurement. The conditions
determined as worst case will then be used for the final measurements. When the EUT is larger than the beam
width of the measuring antenna it will be moved over the surface for the four sides of the equipment. Where
appropriate, the test distance may be reduced in order to detect emissions under better uncertainty and are
calculated at the specified test distance.




CSA Group Bayern GmbH                                                         File No. T38793-00-00JP, page 10 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                        Rev. No. 3.0, 2014-01-30


                                                   FCC ID: QOQWT41

5 TEST CONDITIONS AND RESULTS
5.1      Spurious emissions
For test instruments and accessories used see section 6 Part SER 2, SER 3.
5.1.1    Description of the test location

Test location:                OATS 1
Test location:                Anechoic chamber 1

Test distance:                3m

5.1.2    Photo documentation of the test set-up




CSA Group Bayern GmbH                                                  File No. T38793-00-00JP, page 11 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                            Rev. No. 3.0, 2014-01-30


                                                      FCC ID: QOQWT41


5.1.1    Applicable standard

According to FCC Part 15C, Section 15.209:
The emissions from intentional radiators shall not exceed the effective field strength limits.

5.1.2    Description of Measurement
The radiated power of the spurious emission from the EUT is measured in a test setup following the procedures set
out in ANSI C63.4. In the frequency range above 1GHz a peak detector measurtement is made if the peak result
complies with the average limit then no average measurement is performed.
The resolution bandwidth during the measurement is as follows:
30 MHz – 1000 MHz:               RBW:           120 kHz
1000 MHz – 25 GHz                RBW:           1 MHz

5.1.3    Test result <1GHz

GFSK

CH mid (2441MHz)
                          Frequency        Reading     Correction   Corrected      Limit     Delta
                                           level QP      factor     level QP        QP
                            (MHz)           (dBµV)      (dB/m)      dB(µV/m)     dB(µV/m)     (dB)
                            50.00            11.1         15.1        26.2         40.0      -13.8
                            80.15            13.5         10.3        23.8         40.0      -16.2
                            200.00            5.6         10.9        16.5         43.5      -27.0
                            349.99            6.2         17.2        23.4         46.0      -22.6
                            450.00            3.7         20.4        24.1         46.0      -21.9
                            550.00            3.6         23.0        26.6         46.0      -19.4

DQPSK

CH mid (2441MHz)
                          Frequency        Reading     Correction   Corrected      Limit     Delta
                                           level QP      factor     level QP        QP
                            (MHz)           (dBµV)      (dB/m)      dB(µV/m)     dB(µV/m)     (dB)
                            50.00            11.4         15.1        26.5         40.0      -13.5
                            80.15            13.3         10.3        23.6         40.0      -16.4
                            200.00            5.3         10.6        15.9         43.5      -27.6
                            349.99            6.8         17.2        24.0         46.0      -22.0
                            450.00            3.9         20.4        24.3         46.0      -21.7
                            550.00            3.4         23.0        26.4         46.0      -19.6

8DPSK

CH mid (2441MHz)
                          Frequency        Reading     Correction   Corrected      Limit     Delta
                                           level QP      factor     level QP        QP
                            (MHz)           (dBµV)      (dB/m)      dB(µV/m)     dB(µV/m)     (dB)
                            50.00            10.7         15.1        25.8         40.0      -14.2
                            80.15            13.2         10.3        23.5         40.0      -16.5
                            200.00            4.7         10.9        15.6         43.5      -27.9
                            349.99            6.7         17.2        23.9         46.0      -22.1
                            450.00            4.2         20.4        24.6         46.0      -21.4
                            550.00            3.5         23.0        26.5         46.0      -19.5
CSA Group Bayern GmbH                                                           File No. T38793-00-00JP, page 12 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                     Rev. No. 3.0, 2014-01-30


                                                      FCC ID: QOQWT41



5.1.4    Test result >1GHz

GFSK

CH low (2402MHz)

  Frequency        Reading         Reading         Correction   Corrected   Corrected     Limit       Limit        Delta
                   level PK        level AV          factor      level PK    level AV      PK          AV
     (MHz)          (dBµV)          (dBµV)          (dB/m)      dB(µV/m)    dB(µV/m)    dB(µV/m)    dB(µV/m)         (dB)
    1330.00          59,6            46.7            -19.1         40.5        27.6       74.0        54.0          -25.2
    4804.00          67.2            51.2             2.3          69.5        53.5       74.0        54.0           -0.5
    7206.00          63.4            45.9             6.9          70.3        52.8       74.0        54.0           -1.2
    9608.00          47.1            34.0             7.8          54.9        41.8       74.0        54.0          -12.2
   12010.00          49.2            39.6             1.0          50.2        40.6       74.0        54.0          -13.4
   14412.00          51.3            41.3             2.7          54.0        44.0       74.0        54.0          -10.0
   16814.00          49.9            41.4             6.1          56.0        47.5       74.0        54.0           -6.5

CH mid (2441MHz)

  Frequency        Reading         Reading         Correction   Corrected   Corrected     Limit       Limit        Delta
                   level PK        level AV          factor      level PK    level AV      PK          AV
     (MHz)          (dBµV)          (dBµV)          (dB/m)      dB(µV/m)    dB(µV/m)    dB(µV/m)    dB(µV/m)         (dB)
    1330.00          58.4            46.8            -19.1         39.0        27.7       74.0        54.0          -26.3
    4882.00          65.8            47.1             2.4          68.2        49.4       74.0        54.0           -4.6
    7323.00          60.1            44.7             6.9          66.9        51.5       74.0        54.0           -2.5
    9764.00          47.2            33.4             8.6          55.8        42.0       74.0        54.0          -12.0
   12205.00          55.0            45.4             1.5          56.5        46.9       74.0        54.0           -7.1
   14646.00          54.5            43.8             4.5          59.0        48.3       74.0        54.0           -5.7
   17087.00          46.0            35.0             6.6          52.6        41.6       74.0        54.0          -12.4


CH high (2480MHz)

  Frequency        Reading         Reading         Correction   Corrected   Corrected     Limit       Limit        Delta
                   level PK        level AV          factor      level PK    level AV      PK          AV
     (MHz)          (dBµV)          (dBµV)          (dB/m)      dB(µV/m)    dB(µV/m)    dB(µV/m)    dB(µV/m)         (dB)
    1330.00          57.8            50.0            -19.1         38.7        30.8       74.0        54.0          -23.2
    4960.00          58.8            47.9             2.7          61.5        50.6       74.0        54.0           -3.4
    7440.00          56.8            43.0             6.9          63.7        49.9       74.0        54.0           -4.1
    9920.00          40.9            29.2             8.4          49.3        37.6       74.0        54.0          -16.4
   12400.00          51.6            41.2             1.7          53.3        42.9       74.0        54.0          -11.1
   14880.00          55.5            45.2             3.4          58.9        48.6       74.0        54.0           -5.4
   17360.00          46.5            36.2             6.0          52.5        42.2       74.0        54.0          -11.8




CSA Group Bayern GmbH                                                           File No. T38793-00-00JP, page 13 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                     Rev. No. 3.0, 2014-01-30


                                                      FCC ID: QOQWT41


DQPSK

CH low (2402MHz)

  Frequency        Reading         Reading         Correction   Corrected   Corrected     Limit       Limit        Delta
                   level PK        level AV          factor      level PK    level AV      PK          AV
     (MHz)          (dBµV)          (dBµV)          (dB/m)      dB(µV/m)    dB(µV/m)    dB(µV/m)    dB(µV/m)         (dB)
    1444.00          60.8            49.8            -20.5         40.3        29.2       74.0        54.0          -24.8
    4804.00          71.0            50.3             2.3          73.3        52.6       74.0        54.0           -0.7
    7206.00          63.9            37.0             6.9          70.7        43.8       74.0        54.0           -3.3
    9608.00          51.0            30.5             7.3          58.3        37.8       74.0        54.0          -15.7
   12010.00          51.5            39.9             1.0          52.5        40.9       74.0        54.0          -13.1
   14412.00          51.4            42.6             2.7          54.1        45.4       74.0        54.0           -8.6
   16814.00          52.3            41.3             6.1          58.3        47.4       74.0        54.0           -6.6


CH mid (2441MHz)

  Frequency        Reading         Reading         Correction   Corrected   Corrected     Limit       Limit        Delta
                   level PK        level AV          factor      level PK    level AV      PK          AV
     (MHz)          (dBµV)          (dBµV)          (dB/m)      dB(µV/m)    dB(µV/m)    dB(µV/m)    dB(µV/m)         (dB)
    1330.00          60.4            50.5            -19.5         41.0        31.1       74.0        54.0          -22.9
    4882.00          60.9            49.8             2.4          63.3        52.2       74.0        54.0           -1.8
    7323.00          56.8            41.7             6.9          63.7        48.6       74.0        54.0           -5.4
    9764.00          47.0            34.0             7.8          54.8        41.7       74.0        54.0          -12.3
   12205.00          53.4            44.8             1.5          54.9        46.3       74.0        54.0           -7.7
   14646.00          54.9            44.5             4.5          59.4        49.0       74.0        54.0           -5.0
   17087.00          45.4            34.5             6.6          52.0        41.1       74.0        54.0          -12.9


CH high (2480MHz)

  Frequency        Reading         Reading         Correction   Corrected   Corrected     Limit       Limit        Delta
                   level PK        level AV          factor      level PK    level AV      PK          AV
     (MHz)          (dBµV)          (dBµV)          (dB/m)      dB(µV/m)    dB(µV/m)    dB(µV/m)    dB(µV/m)         (dB)
    2104.00          60.5            51.8            -15.9         44.6        35.9       74.0        54.0          -18.1
    4960.00          62.5            50.4             2.7          65.2        53.1       74.0        54.0           -0.9
    7440.00          56.5            42.9             6.9          63.4        49.8       74.0        54.0           -4.2
    9920.00          40.7            29.7             8.4          49.0        38.1       74.0        54.0          -15.9
   12400.00          51.0            40.4             1.7          52.7        42.2       74.0        54.0          -11.8
   14880.00          55.2            44.7             3.4          58.6        48.1       74.0        54.0           -5.9
   17360.00          46.6            36.3             6.0          52.6        42.3       74.0        54.0          -11.7




CSA Group Bayern GmbH                                                           File No. T38793-00-00JP, page 14 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                     Rev. No. 3.0, 2014-01-30


                                                      FCC ID: QOQWT41


8DPSK

CH low (2402MHz)

  Frequency        Reading         Reading         Correction   Corrected   Corrected     Limit       Limit        Delta
                   level PK        level AV          factor      level PK    level AV      PK          AV
     (MHz)          (dBµV)          (dBµV)          (dB/m)      dB(µV/m)    dB(µV/m)    dB(µV/m)    dB(µV/m)         (dB)
    1444.00          61.1            49.2            -20.5         40.5        28.6       74.0        54.0          -25.4
    4804.00          70.6            50.3             2.3          72.9        52.6       74.0        54.0           -1.1
    7206.00          61.7            42.2             6.9          68.6        49.1       74.0        54.0           -4.9
    9608.00          46.3            30.5             7.3          53.6        37.8       74.0        54.0          -16.2
   12010.00          51.7            41.5             1.0          52.7        42.5       74.0        54.0          -11.5
   14412.00          51.1            39.4             2.7          53.8        42.1       74.0        54.0          -11.9
   16814.00          53.0            38.6             6.1          59.1        44.7       74.0        54.0           -9.3


CH mid (2441MHz)

  Frequency        Reading         Reading         Correction   Corrected   Corrected     Limit       Limit        Delta
                   level PK        level AV          factor      level PK    level AV      PK          AV
     (MHz)          (dBµV)          (dBµV)          (dB/m)      dB(µV/m)    dB(µV/m)    dB(µV/m)    dB(µV/m)         (dB)
    1444.00          57.1            48.0            -20.0         37.1        27.9       74.0        54.0          -26.1
    4882.00          66.0            51.0             2.4          68.4        53.4       74.0        54.0           -0.6
    7323.00          59.1            42.7             6.9          66.0        49.6       74.0        54.0           -4.4
    9764.00          52.4            33.5             7.8          60.2        41.3       74.0        54.0          -12.7
   12205.00          54.6            43.2             1.5          56.1        44.7       74.0        54.0           -9.3
   14646.00          52.9            43.3             4.5          57.4        47.8       74.0        54.0           -6.2
   17087.00          45.1            34.8             6.6          51.7        41.4       74.0        54.0          -12.6


CH high (2480MHz)

  Frequency        Reading         Reading         Correction   Corrected   Corrected     Limit       Limit        Delta
                   level PK        level AV          factor      level PK    level AV      PK          AV
     (MHz)          (dBµV)          (dBµV)          (dB/m)      dB(µV/m)    dB(µV/m)    dB(µV/m)    dB(µV/m)         (dB)
    1444.00          57.6            46.6            -20.0         37.6        26.5       74.0        54.0          -27.5
    4960.00          58.9            48.9             2.7          61.6        51.6       74.0        54.0           -2.4
    7440.00          54.3            42.7             6.9          61.3        49.6       74.0        54.0           -4.4
    9920.00          40.3            28.5             8.4          48.7        36.9       74.0        54.0          -17.1
   12400.00          50.0            40.0             1.7          51.7        41.8       74.0        54.0          -12.2
   14880.00          52.2            43.2             3.4          55.6        46.6       74.0        54.0           -7.4
   17360.00          46.3            36.2             6.0          52.3        42.2       74.0        54.0          -11.8




CSA Group Bayern GmbH                                                           File No. T38793-00-00JP, page 15 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                     Rev. No. 3.0, 2014-01-30


                                                   FCC ID: QOQWT41


Limit according to FCC Part 15 Subpart 15.209(a):

          Frequency              Field strength of spurious emissions          Measurement distance
            (MHz)                    (µV/m)               dB(µV/m)                   (metres)
         0.009-0.490              2400/F(kHz)                 --                       300
         0.490-1.705             24000/F (kHz)                --                        30
         1.705-30.0                     30                   29.5                       30
             30-88                     100                    40                         3
            88-216                     150                   43.5                        3
           216-960                     200                    46                         3
         Above 960                     500                    54                         3


The requirements are FULFILLED.


Remarks:            The measurement in the frequency range 30 MHz to 1000MHz was made on the middle channel.

                    Prescans showed that the emission level in this frequency range depends NOT on the set

                    transmission channel.




CSA Group Bayern GmbH                                                     File No. T38793-00-00JP, page 16 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                 Rev. No. 3.0, 2014-01-30


                                                    FCC ID: QOQWT41



6 USED TEST EQUIPMENT AND ACCESSORIES
All test instruments used are calibrated and verified regularly. The calibration history is available on request.

   Test ID         Model Type                      Equipment No.     Next Calib.     Last Calib.    Next Verif.       Last Verif.
   SER 2          ESVS 30                          02-02/03-05-006    03/07/2015       03/07/2014
                  VULB 9168                        02-02/24-05-005    08/04/2015       08/04/2014    04/03/2015      04/09/2014
                  S10162-B                         02-02/50-05-031
                  NW-2000-NB                       02-02/50-05-113
                  KK-EF393/U-16N-21N20 m           02-02/50-12-018

   SER 3          FSP 30                           02-02/11-05-001    24/10/2014       24/10/2013
                  JS4-18004000-30-5A               02-02/17-05-017
                  AFS5-12001800-18-10P-6           02-02/17-06-002
                  AFS4-01000400-10-10P-4           02-02/17-13-002
                  AMF-4F-04001200-15-10P           02-02/17-13-003
                  3117                             02-02/24-05-009    07/05/2015       07/05/2014
                  BBHA 9170                        02-02/24-05-014
                  Sucoflex N-1600-SMA              02-02/50-05-073
                  Sucoflex N-2000-SMA              02-02/50-05-075
                  KMS102-0.2 m                     02-02/50-11-020
                  SF104/11N/11N/1500MM             02-02/50-13-015




CSA Group Bayern GmbH                                                              File No. T38793-00-00JP, page 17 of 17
Ohmstrasse 1-4  94342 STRASSKIRCHEN  GERMANY
Tel.: +49(0)9424-94810  Fax: +49(0)9424-9481440                                                           Rev. No. 3.0, 2014-01-30



Document Created: 2014-10-14 10:30:21
Document Modified: 2014-10-14 10:30:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC