RF exposure info

FCC ID: QOQWRAP2022-1-B2B

RF Exposure Info

Download: PDF
FCCID_469518

attn: Reviewing Engineer
Federal Communications Commission
7435 Oakland Mills Road
Columbia, MD 21046


July 22, 2004


RE: RF exposure information FCC ID: QOQWRAP2022-1-B2B

FCC ID Number Product              Title/Model

QOQWRAP2022-1-B2B                  Bluetooth board-to-board module/ WRAP THOR 2022-1-B2B



TO WHOM IT MAY CONCERN

The product stated above is designed as module to be installed in other devices. This device is to be used only
for fixed and mobile applications. If the final product after integration is intended for portable use, a new
application and FCC is required.

The product WRAP THOR 2022-1-B2B uses an integrated antenna. This transmitter must be installed to
provide a separation distance of at least 20 cm from everybody and must not be co-located or operating in
conjunction with any other antenna or transmitter.

The table below is excerpted from Table 1B of 47 CFR 1.1310 titled Limits for Maximum Permissible
Exposure (MPE), Limits for General Population/Uncontrolled Exposure:


  Frequency Range (MHz)               Power Density (mW/cm2)               Averaging Time (minutes)

          300 – 1500                             f/1500                                 30

        1500 – 100.000                            1.0                                   30

The equipment WRAP THOR 2022-1-B2B transmits in the 2400 - 2483.5 MHz frequency range, so the
applicable MPE limit is 1 mW/cm2.

Ander the conditions stated above MPE limits can be guaranteed as the calculation below shows:

Measured maximum peak output power (e.i.r.p.) = 12.55 dBm at 2441 MHz = 17.99 mW e.i.r.p.
Measurement uncertainty (dB) = +1.98/+1.75 dB

Maximum peak output power (e.i.r.p.) = Measured maximum peak output power (e.i.r.p.) + Measurement
uncertainty (dB) = 12.55 + 1.98 dB = 14.53 dB = 28.38 mW e.i.r.p.

Using Equation from page 18 of OET Bulletin 65, Edition 97-01:

S = P·G/4pR2


Where,

S = power density in mW/cm2 (1 mW/cm2 used for G)
P = power input to the antenna
G = power gain of the antenna in the direction of interest relative to an isotropic radiator
R = distance to the centre of radiation of the antenna in cm (20 cm Prediction distance)

We obtain the following results:


                                                              Maximum                           S - Power
  Measured           Measurement        Maximum EIRP                           R - Prediction
                                                               E.I.R.P.                          density
 E.I.R.P. (dB)      uncertainty (dB)        (dB)                               distance (cm)
                                                                (mW)                            (mW/cm2)

       12.55          +1.98/-1.75             14.53             28.38               20          0.005646


This prediction demonstrates that:

The power density levels at a distance of 20 cm are below the maximum levels allowed by the FCC rules.

Conclusion:

The equipment WRAP THOR 2022-1-B2B complies with the MPE if it is installed to provide a separation
distance of at least 20 cm from everybody.

Sincerely,

P.A.




Mr. Mikael Björkas
HW Project Manager
Bluegiga Technologies Inc.
Sinikalliontie 11, 02631 Espoo, Finland
Phone: +358 40 848 3339
E-mail: Mikael.Bjorkas@bluegiga.com