                                       RF EXPOSURE ANALYSIS

Product                                    FCC ID                       IC number
WLAN module                                QOQWF121                     5123A-BGTWF121

WF121 is a general use IEEE 802.11 (Wi-Fi) transceiver module meant to provide wireless connectivity for
various low complexity microcontroller platforms without capability of running the Wi-Fi stack. WF121 contains
a microcontroller running the full Wi-Fi stack and provides customers with connectivity through serial port or
USB with simple commands. WF121 can also be used to run simple customer applications on the module
internal microcontroller.

WF121 supports the IEEE 802.11b/g/n wireless networking standards with a single spatial stream and 20MHz
or 22MHz bandwidth, allowing bitrates of up to 72.2Mbps. Module can be operated with batteries or DC power
supply.

Analysis for FCC

The equipment transmits in the 2 412 – 2 462 MHz frequency range and therefore the applicable threshold is
calculated as stated in FCC document KDB 447498 by using the formula              60        (where f is a highest frequency
                                                                                        f
in used) 60           = 24.37 mW
              2.462

Output power considerations:

Max. E.I.R.P value: 21.17 dBm = 130.91 mW
(Value is taken from the test report number: 266892-1. Value contains conducted output power and
antenna gain.)

RF exposure evaluation:

     P G E.I .R.P
S=        =
     4 R2   4 R2

   E.I.R.P (dB)          E.I.P.R (mW)       Evaluation distance (cm)             S – power density (mW/cm2)
       21.17                 130.91                    20                                  0.026

Analysis for IC

According to standard RSS-102, RF exposure analysis is required for devices operating at or above 1.5 GHz if
the maximum E.I.R.P. of the device is 5.0 W or more. Therefore RF exposure analysis is not required for this
device.

Result:

Equipment complies with the FCC and IC limits for maximum permissible exposure



               SGS Fimko Ltd   Särkiniementie 3, PO Box 30 FI-00211 Helsinki, Finland