                       Report No.: SA190408C21A

                             FCC ID: QOQGM210P

                       Test Model: MGM210P32A, MGM210P22A

                  Series Model: BGM210P32A, BGM210P22A

                 Received Date: Apr. 08, 2019

                         Test Date: Apr. 13 ~ Jun. 17, 2019

                     Issued Date: Jul. 26, 2019


                         Applicant: Silicon Laboratories Finland Oy

                          Address: Alberga Business Park - Bldg D/Floor 5, Bertel Jungin aukio 3, 02600
                                   ESPOO, FINLAND

                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Lin Kou Laboratories
                    Lab Address: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan,
                                 R.O.C.
                  Test Location: No. 19, Hwa Ya 2nd Rd., Wen Hwa Vil., Kwei Shan Dist., Taoyuan City
                                 33383, TAIWAN (R.O.C.)
         FCC Registration / 788550 / TW0003
       Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: SA190408C21A                                             Page No. 1 / 6                                             Report Format Version: 6.1.1
Reference No.: 190719C02


                                                                 Table of Contents
Release Control Record .................................................................................................................................. 3
1        Certificate of Conformity...................................................................................................................... 4
2        Evaluation Result .................................................................................................................................. 5
3        SAR Test Exclusion Thresholds.......................................................................................................... 6




Report No.: SA190408C21A                                           Page No. 2 / 6                                            Report Format Version: 6.1.1
Reference No.: 190719C02


                                         Release Control Record


Issue No.             Description                                        Date Issued
SA190408C21A          Original release                                   Jul. 26, 2019




Report No.: SA190408C21A                    Page No. 3 / 6        Report Format Version: 6.1.1
Reference No.: 190719C02


1    Certificate of Conformity


            Product: Bluetooth Low Energy and ZigBee wireless radio modules

              Brand: Silicon Labs

        Test Model: MGM210P32A, MGM210P22A

      Series Model: BGM210P32A, BGM210P22A

    Sample Status: Engineering sample

          Applicant: Silicon Laboratories Finland Oy

          Test Date: Apr. 13 ~ Jun. 17, 2019

         Standards: FCC Part 2 (Section 2.1093)

                           KDB 447498 D01 General RF Exposure Guidance v06

                           IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s RF characteristics under the conditions specified in this report.




      Prepared by :                                               , Date:        Jul. 26, 2019
                                  Polly Chien / Specialist




     Approved by :                                                , Date:        Jul. 26, 2019
                           Bruce Chen / Senior Project Engineer




Report No.: SA190408C21A                         Page No. 4 / 6                       Report Format Version: 6.1.1
Reference No.: 190719C02


2     Evaluation Result
Following FCC KDB 447498 D01 “General SAR test exclusion guidance”

The corresponding SAR Exclusion Threshold condition, listed below:

1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
   mm are determined by:
    [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)]
    ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16 where
     f(GHz) is the RF channel transmit frequency in GHz.
     Power and distance are rounded to the nearest mW and mm before calculation.
     The result is rounded to one decimal place for comparison The test exclusions are applicable only when
        the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100 MHz
        and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied to
        determine SAR test exclusion.

2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is
   determined according to the following:
    a) [Threshold at 50 mm in step 1) + (test separation distance - 50mm)·( f(MHz)/150)] mW, at 100MHz to
       1500 MHz
    b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6
       GHz

3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion.
    a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 +
       log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm.
    b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
       separation distances ≤ 50 mm.
    c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot
       be applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to
       be acceptable.




Report No.: SA190408C21A                        Page No. 5 / 6                          Report Format Version: 6.1.1
Reference No.: 190719C02


3    SAR Test Exclusion Thresholds
For Body
                                                                                              Min. test
                                                                         SAR exemption
                                                                                             separation
        FCC                 Power     Duty Cycle     Calculated Power       minimum
                                                                                              distance
                                                                         distances (mm)
                                                                                                (mm)
     High      BT          19.96dBm    84.30%      19.96-0.74=19.22dBm       44.03               5.0
    Power    Zigbee        20.18dBm     66%         20.18-1.8=18.38dBm       36.17               5.0
     Low       BT          10.83dBm    84.30%      10.83-0.74=10.09dBm        5.3                5.0
    Power    Zigbee        10.89dBm     66%         10.89-1.8=9.09dBm          5                 5.0

For Extremity
                                                                                              Min. test
                                                                         SAR exemption
                                                                                             separation
        FCC                 Power     Duty Cycle     Calculated Power       minimum
                                                                                              distance
                                                                         distances (mm)
                                                                                                (mm)
     High      BT          19.96dBm    84.30%      19.96-0.74=19.22dBm       17.28               5.0
    Power    Zigbee        20.18dBm     66%         20.18-1.8=18.38dBm       14.25               5.0
     Low       BT          10.83dBm    84.30%      10.83-0.74=10.09dBm         5                 5.0
    Power    Zigbee        10.89dBm     66%         10.89-1.8=9.09dBm          5                 5.0
Note:
1. Determining compliance based on the results of the compliance measurement, not taking into account
    measurement instrumentation uncertainty.
2. The Dipole antenna with 2.14dBi gain.
   The Chip antenna with 1.86dBi gain.
3. Min separation distance for High power BT = 44.03 mm and Zigbee = 36.17 mm with Portable-body device.
    Min separation distance for Low power BT = 5.3 mm and Zigbee = 5.0 mm with Portable-body device.
4. Min separation distance for High power BT = 17.28 mm and Zigbee = 14.25 mm with Portable-extremity
    device. Min separation distance for Low power BT = 5.0 mm and Zigbee = 5.0 mm with Portable-extremity
    device.
5. Calculate SAR test exclusion thresholds from condition “1” formulas.



---END---




Report No.: SA190408C21A                     Page No. 6 / 6                       Report Format Version: 6.1.1
Reference No.: 190719C02



Document Created: 2019-09-29 10:38:59
Document Modified: 2019-09-29 10:38:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC