                                RF EXPOSURE ANALYSIS

 Product                                          FCC ID
 BGM121 / BGM123 Bluetooth Module                  QOQBGM12LMA


 Analysis for FCC, portable use
 Standalone SAR test exclusion considerations are defined in the KDB 447498 Chapter 4.3.1.
 1-g head or body SAR exclusion threshold is defined with formula

 [(max . power of channel, including tune-up tolerance, mW)/(min. separation distance,
 mm.)]* (√f(GHz))≤3

 For BGM121 / BGM123 the absolute maximum TXP including tolerances 11.2 mW and
 maximum TX frequency is 2.48 GHz. Using separation distance of 6 mm with the formula
 above results

  11.22mW 
            2.48  2.95  3
  6mm 

 Thus BGM121 / BGM123 meets the SAR exclusion criteria with 6 mm separation. If the
 separation distance to human body is 6mm or more then SAR evaluation is not needed.

 Analysis for FCC, mobile use

       E. I .R.P    11.22mW
 S                               0.00189mW / cm 2
        4R   2
                   4  (20cm ) 2



       E.I.R.P (mW)             Evaluation     Power density     MPE limit for   Verdict
                                distance R     S at prediction   uncontrolled
                                   (cm)          frequency       exposure at
                                                 (mW/cm2)         prediction
                                                                  frequency
                                                                  (mW/cm2)
             11.22                    20          0.00223             1          PASS




Alberga Business Park, Bertel Jungin aukio 3