RF Exposure letter

FCC ID: QOQBGM12LMA

RF Exposure Info

Download: PDF
FCCID_3233792

sILICON LABS
December 2, 2016



Re: ISEDC RF exposure evaluation of BGM121/BGM123


Dear Application Examiner
To help the module integrators avoid SAR testing with the end product assembly we have
tested the worst case SAR for the BGM121A. BGM123A is the same module but with the
TXP limited to 3 dBm, so the same worst case SAR will apply to both BGM121A and
BGM123A. The SAR was tested with the optimal board design which has been identified to
provide highest emissions and highest radiated transmit power from the antenna. To identify
the optimal board design for the antenna used in BGM12xA, the antenna specification has
been consulted and the module has been tested on several board sizes by measuring the
antenna gain and efficiency.




                   Figure 1: Identiication of the optimal board design for the module


As shown in the SAR test report, the BGM121A is compliant to the SAR limits for body worn
devices with separation distance of 2 mm and thus, as described in the RSS—102, BGM121A
{and BGM123A) can be placed in touch with the human body without further SAR evaluation

The modules with only RF pin, BGM121N and BGM123N, have not been tested for the worst
case SAR and thus the SAR exclusion limits will apply normally to these two models.



Best regards


   2—                                  c
Pasi Rahikkala, Staff HW Engineer
Silicon Labs