RF Exposure Assessment

FCC ID: QOBRGBXYZA

RF Exposure Info

Download: PDF
FCCID_3380071

                    RF Exposure Report
KDB 447498 D01 v06 section 4.3.1 SAR test exclusion thresholds formula:




Tune‐up Procedure
EUT Max technical
Channel center frequency: 2442MHz
(Peak) output power: 8.79dBm/7.57mW
Tune up out power: 9.5dBm/8.91mW(9mW is nearest mW)


Extremity‐SAR
The reasonable distance is min 5mm
9mW / 5mm x (2.442)^0.5 = 2.81
2.81<extermity‐SAR test exclusion thresholds limit=7.5


Body‐SAR
The reasonable distance is min 5mm
20mW / 20mm x (2.462)^0.5 = 2.81
2.81<body‐SAR test exclusion thresholds limit=3.0


So the Extremity‐SAR and Body‐SAR needless assess.



Document Created: 2017-04-26 14:56:05
Document Modified: 2017-04-26 14:56:05

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC