RF Test Report

FCC ID: QOAMC-8250R

Test Report

Download: PDF
FCCID_1877865

            FCC TEST REPORT
          FCC ID: QOAMC-8250R


               Product: Wireless digital PIR detector

          Trade Name:

          Model Name: MC-8250R
          Serial Model: N/A
            Report No.: NTEK- 2012NT1214549F




                         Prepared for
               Shenzhen Meian Technology Co.,Ltd .

   No.32,Lanshui Rd,Longdong,Longgang District,Shenzhen,China




                          Prepared by
            Shenzhen NTEK Testing Technology Co., Ltd.
1/F, Building E, Fenda Science Park, Sanwei Community,Xixiang Street
                  Bao’an District, Shenzhen P.R. China
          Tel.: +86-0755-61156588 Fax.: +86-0755-61156599
                        Website:www.ntek.org.cn


                                                           Page 2 of 31            Report No.: NTEK- 2012NT1214549F



                                             TEST RESULT CERTIFICATION

    Applicant’s name ................. : Shenzhen Meian Technology Co.,Ltd .
    Address ................................. : No.32,Lanshui Rd,Longdong,Longgang District,Shenzhen,China
    Manufacture's Name ............ : Shenzhen Meian Technology Co.,Ltd .
    Address ................................. :
                                                     No.32,Lanshui Rd,Longdong,Longgang District,Shenzhen,China

    Product description
    Product name ........................... : Wireless digital PIR detector
    Model and/or type reference : MC-8250R
    Serial Model:                                    N/A
    Rating(s) ................................ : DC 3V
    Standards ............................. : FCC Part15.231

    Test procedure .............................. ANSI C63.4-2003
    This device described above has been tested by NTEK, and the test results show that the
    equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only
    to the tested sample identified in the report.
    This report shall not be reproduced except in full, without the written approval of NTEK, this
    document may be altered or revised by NTEK, personal only, and shall be noted in the revision of
    the document.
    Date of Test ............................................ :
    Date (s) of performance of tests ............. :                11 Dec 2012 ~16 Dec 2012
    Date of Issue ........................................... :     06 Jan 2013
    Test Result ............................................... :   Pass



                              Testing Engineer                  :

                                                                             (Apple Huang)


                              Technical Manager                 :

                                                                              (Tom Zhang)


                              Authorized Signatory :

                                                                              (Bovey Yang)




`


                                 Page 3 of 31      Report No.: NTEK- 2012NT1214549F



                               Table of Contents                        Page


    1 . SUMMARY OF TEST RESULTS                                                4
      1.1 TEST FACILITY                                                        5
      1.2 MEASUREMENT UNCERTAINTY                                              5
    2 . GENERAL INFORMATION                                                    6
      2.1 GENERAL DESCRIPTION OF EUT                                           6
      2.2 DESCRIPTION OF TEST MODES                                            7
      2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED              8
      2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE)                         9
      2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS                                10
    3 . ANTENNA REQUIREMENT                                                11
      3.1 STANDARD REQUIREMENT                                              11
      3.2 EUT ANTENNA                                                       11
      3.3     CONDUCTED EMISSION MEASUREMENT                               12
            3.3.1 POWER LINE CONDUCTED EMISSION LIMITS                     12
            3.3.2 TEST PROCEDURE                                           13
            3.3.3 DEVIATION FROM TEST STANDARD                             13
            3.3.4 TEST SETUP                                               13
            3.2.5 TEST RESULT                                              14
      3.4 RADIATED EMISSION MEASUREMENT                                    15
         3.4.1 RADIATED EMISSION LIMITS                                    15
         3.4.2 TEST PROCEDURE                                              16
         3.4.3 DEVIATION FROM TEST STANDARD                                16
         3.4.4 TEST SETUP                                                  16
         3.4.5 TEST RESULTS (BLOW 30MHZ)                                   18
         3.4.6 TEST RESULTS (BETWEEN 30 – 1000 MHZ)                        19
    4 . BANDWIDTH TEST                                                     23
            4.1 TEST PROCEDURE                                             23
            4.2 DEVIATION FROM STANDARD                                    23
            4.3 TEST SETUP                                                 23
            4.4 TEST RESULTS                                               24
    5 . TRANSMITTER TIMEOUT                                                27
            5.1 REQUIREMENTS                                               27
    6 . EUT TEST PHOTO                                                     31
     APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS




`


                                         Page 4 of 31            Report No.: NTEK- 2012NT1214549F


    1. SUMMARY OF TEST RESULTS

    Test procedures according to the technical standards:
                                         FCC Part15, Subpart C
        Standard
                                       Test Item                      Judgment        Remark
         Section
         15.207                  Conducted Emission                      N/A           Note(1)

         15.203                  Antenna Requirement                    Pass

        15.231b              Radiated Spurious Emission                 Pass

         15.231c                 Occupied Bandwidth                     Pass

      15.231a(1)(2)                Deactivation Time                    Pass


    NOTE:
    (1) ” N/A” denotes test is not applicable in this Test Report.




`


                                        Page 5 of 31            Report No.: NTEK- 2012NT1214549F


    1.1 TEST FACILITY
       NTEK Testing Technology Co., Ltd
       Add. : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District,
      Shenzhen P.R. China.
       FCC Registration No.:238937; IC Registration No.:9270A-1

    1.2 MEASUREMENT UNCERTAINTY
      The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
      standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
      approximately 95 %。

                 No.      Item                                  Uncertainty
                 1        Conducted Emission Test               ±1.38dB
                 2        RF power,conducted                    ±0.16dB
                 3        Spurious emissions,conducted          ±0.21dB
                 4        All emissions,radiated(<1G)           ±4.68dB
                 5        All emissions,radiated(>1G)           ±4.89dB
                 6        Temperature                           ±0.5°C
                 7        Humidity                              ±2%




`


                                          Page 6 of 31             Report No.: NTEK- 2012NT1214549F


    2. GENERAL INFORMATION

    2.1 GENERAL DESCRIPTION OF EUT



              Equipment                   Wireless digital PIR detector

              Trade Name

              Model Name                  MC-8250R
              Serial Model                N/A
              Model Difference            N/A
                                          The EUT is a Wireless digital PIR detector

                                          Product Type             Remote Control
                                          Operation Frequency:     433.98MHz
                                          Modulation Type:         FSK
                                          Number Of Channel        1CH.
                                          Antenna Designation:     Build-in ANT
              Product Description         Antenna Gain(Peak)       0.8dBi
                                          Output Power:            68.90 dBuV/m @3m(AV Max.)

                                          Based on the application, features, or specification
                                          exhibited in User's Manual, the EUT is considered as an
                                          ITE/Computing Device. More details of EUT technical
                                          specification, please refer to the User's Manual.

              Channel List                N/A
              Adapter                     N/A
              Battery                     DC 3.0V
    Note:
        1. For a more detailed features description, please refer to the manufacturer’s specifications
           or the User's Manual.

        2.
             Table for Filed Antenna
              Ant
                     Brand       Model Name       Antenna Type     Connector Gain (dBi)     NOTE
               .
              1         N/A         N/A             Build-in ANT      N/A         0.8      Antenna
         3
             Operation principle:
             (1).TEST MODE:When the PIR tamper switch or PIR was detected object invasion, the
             CPU will send data to wireless module. And wireless module send out the data.

             (2).NORMAL MODE:Every hour a short "supervision" message whose duration 575 msec
             is emitted about battery information.

             (3).CODING MODE:When the detector is under operation status,inverse it to make it send
             an address code to control panel.



`


                                        Page 7 of 31             Report No.: NTEK- 2012NT1214549F


    2.2 DESCRIPTION OF TEST MODES

      To investigate the maximum EMI emission characteristics generates from EUT, the test system
      was pre-scanning tested base on the consideration of following EUT operation mode or test
      configuration mode which possible have effect on EMI emission level. Each of these EUT
      operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

          Pretest Mode                                 Description
             Mode 1                                        TX1
             Mode 2                                        TX2
             Mode 3                                        TX3


                                   For Conducted Emission

         Final Test Mode                               Description
                                                           N/A

                                    For Radiated Emission

         Final Test Mode                               Description
             Mode 1                                        TX1
             Mode 2                                        TX2
             Mode 3                                        TX3
      Note:
      (1) The EUT use new battery.
      (2)” N/A” denotes test is not applicable in this Test Report.
      TX1 mode is TEST MODE
      TX2 mode is NORMAL MODE
      TX3 mode is CODING MODE




`


                                      Page 8 of 31   Report No.: NTEK- 2012NT1214549F


    2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED


    Radiated Spurious Emission Test




                                      E-1
                                      EUT




`


                                            Page 9 of 31          Report No.: NTEK- 2012NT1214549F


    2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE)

    The EUT has been tested as an independent unit together with other necessary accessories or
    support units. The following support units or accessories were used to form a representative test
    configuration during the tests.

    Item         Equipment             Mfr/Brand      Model/Type No.   Series No.          Note
             Wireless digital PIR
    E-1                                                    MC-8250R       N/A              EUT
                    detector




     Item    Shielded Type   Ferrite Core        Length                      Note




     Note:
      (1)     The support equipment was authorized by Declaration of Confirmation.
      (2)     For detachable type I/O cable should be specified the length in cm in『Length』column.




`


                                       Page 10 of 31              Report No.: NTEK- 2012NT1214549F

    2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS

    Radiation Test equipment
    Item Kind of Equipment        Manufacturer         Type No.      Serial No.   Calibrated until
      1 Spectrum Analyzer           Agilent            E4407B       160400005      Jul. 06. 2013
     2      Test Receiver            R&S                ESPI          101318       Jul. 06. 2013
     3      Bilog Antenna           TESEQ          CBL6111D           31216        Jul. 06. 2013
     4    50Ω Coaxial Switch        Anritsu            MP59B        6200264416     Jul. 06. 2013
     5    Spectrum Analyzer       ADVANTEST             R3132       150900201      Jul. 06. 2013
     6      Horn Antenna              EM          EM-AH-10180 2011071402           Jul. 06. 2013
     7        Horn Ant         Schwarzbeck         BBHA 9170         9170-181      Jul. 06. 2013
     8        Amplifier               EM           EM-30180           060538       Jul. 06. 2013
     9      Loop Antenna             ARA           PLA-1030/B          1029        Jul. 06. 2013
     10      Power Meter             R&S                NRVS          100696       Jul. 06. 2013

    Conduction Test equipment
    Item Kind of Equipment    Manufacturer             Type No.      Serial No.   Calibrated until
      1    Test Receiver         R&S                     ESCI         101160       Jul. 06. 2013
     2          LISN                 R&S               ENV216         101313       Jul. 06. 2013
     3          LISN                 EMCO              3816/2        00042990      Jul. 06. 2013
     4    50Ω Coaxial Switch        Anritsu            MP59B        6200264417     Jul. 06. 2013
     5     Passive Voltage
                                     R&S               ESH2-Z3        100196       Jul. 06. 2013
               Probe
     6     Absorbing clamp           R&S               MOS-21         100423       Jul. 06. 2013




`


                                         Page 11 of 31             Report No.: NTEK- 2012NT1214549F


    3. ANTENNA REQUIREMENT


    3.1 STANDARD REQUIREMENT

       15.203 requirements: For intentional device, according to 15.203: an intentional radiator shall
         be designed to ensure that no antenna other than that furnished by the responsible party
         shall be used with the device.

    3.2 EUT ANTENNA

    The EUT antenna is Build-in ANT. It complies with the standard requirement.




`


                                          Page 12 of 31          Report No.: NTEK- 2012NT1214549F


    3.3 CONDUCTED EMISSION MEASUREMENT

    3.3.1 POWER LINE CONDUCTED EMISSION Limits               (Frequency Range 150KHz-30MHz)

                                       Class A (dBuV)            Class B (dBuV)
       FREQUENCY (MHz)                                                                   Standard
                                  Quasi-peak       Average   Quasi-peak      Average
             0.15 -0.5                                        66 - 56 *      56 - 46 *   CISPR
             0.50 -5.0                                         56.00          46.00      CISPR
             5.0 -30.0                                         60.00          50.00      CISPR


             0.15 -0.5                                        66 - 56 *      56 - 46 *   LP002.
             0.50 -5.0                                         56.00          46.00      LP002.
            5.0 -30.0                                         60.00      50.00       LP002.
           Note:
             (1) The tighter limit applies at the band edges.
             (2) The limit of " * " marked band means the limitation decreases linearly with the
                 logarithm of the frequency in the range.


    The following table is the setting of the receiver
                 Receiver Parameters                                       Setting
                       Attenuation                                          10 dB
                     Start Frequency                                      0.15 MHz
                     Stop Frequency                                        30 MHz
                      IF Bandwidth                                          9 kHz




`


                                               Page 13 of 31                Report No.: NTEK- 2012NT1214549F



    3.3.2 TEST PROCEDURE
     a. The EUT was placed 0.4 meters from the horizontal ground plane with EUT being connected
        to the power mains through a line impedance stabilization network (LISN). All other support
        equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
        impedance for the measuring instrument.
     b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
        and forth in the center forming a bundle 30 to 40 cm long.
     c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
        cable may be terminated, if required, using the correct terminating impedance. The overall
        length shall not exceed 1 m.
     d. LISN at least 80 cm from nearest part of EUT chassis.
     e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
    3.3.3 DEVIATION FROM TEST STANDARD
    No deviation


    3.3.4 TEST SETUP
                            V e r tic a l R e fe r e n c e
                            G r o u n d P la n e                                                T e s t R e c e iv e r


                            EUT
           40cm




                                                             80cm
           L IS N




                                                                           H o r iz o n ta l R e f e r e n c e
                                                                            G r o u n d P la n e

             N o te : 1 .S u p p o r t u n its w e r e c o n n e c te d to s e c o n d L IS N .
                      2 .B o t h o f L IS N s ( A M N ) a r e 8 0 c m fr o m E U T a n d a t le a s t 8 0
                         f r o m o th e r u n its a n d o t h e r m e ta l p la n e s




`


                                           Page 14 of 31               Report No.: NTEK- 2012NT1214549F


    3.2.5 TEST RESULT

     EUT:               Wireless digital PIR detector     Model Name. :      MC-8250R
     Temperature:       26 ℃                              Relative Humidity: 54%
     Pressure:          1010hPa                           Phase :            L
     Test Voltage :     N/A                               Test Mode:         N/A
    Note: It is powered by the battery, Conduction emission test is is not applicable.




`


                                        Page 15 of 31               Report No.: NTEK- 2012NT1214549F


    3.4 RADIATED EMISSION MEASUREMENT

    3.4.1 Radiated Emission Limits     ( FCC 15.209 )
          Frequencies              Field Strength                     Measurement Distance
              (MHz)              (micorvolts/meter)                        (meters)

          0.009~0.490                     2400/F(KHz)                           300
          0.490~1.705                    24000/F(KHz)                           30
           1.705~30.0                           30                              30
              30~88                            100                               3
             88~216                            150                               3
            216~960                            200                               3
           Above 960                           500                               3
          Note:
             (1) The tighter limit applies at the band edges.
             (2) Emission level (dBuV/m)=20log Emission level (uV/m).


         LIMITS OF RADIATED EMISSION MEASUREMENT ( FCC 15.231)
                                             Field Strength of          Field Strength of Unwanted
          Fundamental Frequency
                                             fundamental                Emissions
                         (MHz)
                                             (microvolts/meter)         (microvolts/meter)
                   40.66 - 40.70                    2250.00                         225.00
                     70 - 130                       1250.00                         125.00
                    130 - 174                   1,250 to 3,750 **               125 to 375 **
                    174 - 260                       3750.00                         375.00
                    260 - 470                  3,750 to 12,500 **              375 to 1,250 **
                    Above 470                       12500.00                        1250.00
         Notes:
            (1) ** linear interpolations
                [Where F is the frequency in MHz, the formulas for calculating the maximum
                permitted fundamental field strengths are as follows: for the band 130-174 MHz,
                uV/m at 3 meters = 56.81818(F) - 6136.3636; for the band 260-470 MHz, uV/m at 3
                meters = 41.6667(F) - 7083.3333. The maximum permitted unwanted emission level
                is 20 dB below the maximum permitted fundamental level.]
                The limits on the field strength of the spurious emissions in the above table are based
                on the fundamental frequency of the intentional radiator. Spurious emissions shall be
                attenuated to the average (or, alternatively, CISPR quasi-peak) limits shown in this
                table or to the general limits shown in 93 Section 15.209, whichever limit permits a
                higher field strength.


     Spectrum Parameter                         Setting
     Attenuation                                Auto
     Start Frequency                            1000 MHz
     Stop Frequency                             10th carrier harmonic
     RB / VB (emission in restricted band)      1MHz / 1MHz for Peak



`


                                         Page 16 of 31             Report No.: NTEK- 2012NT1214549F


     Receiver Parameter                          Setting
     Attenuation                                 Auto
     Start ~ Stop Frequency                      9kHz~150kHz / RB 200Hz for QP
     Start ~ Stop Frequency                      150kHz~30MHz / RB 9kHz for QP
     Start ~ Stop Frequency                      30MHz~1000MHz / RB 120kHz for QP

    3.4.2 TEST PROCEDURE
     a. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz.
        For frequencies above 1GHz, any suitable measuring distance may be used.
     b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3m meter
        open area test site. The table was rotated 360 degrees to determine the position of the highest
        radiation.
     c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test
        antenna shall vary between 1 m to 4 m.
     d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector
        mode pre-scanning the measurement frequency range.

     e. For the actual test configuration, please refer to the related Item –EUT Test Photos.
        Note:
        Both horizontal and vertical antenna polarities were tested
        and performed pretest to three orthogonal axis. The worst case emissions were reported
    3.4.3 DEVIATION FROM TEST STANDARD
    No deviation

    3.4.4 TEST SETUP
    (A)Radiated Emission Test-Up Frequency Below 30MHz




`


                                  Page 17 of 31         Report No.: NTEK- 2012NT1214549F


    (B)Radiated Emission Test-Up Frequency 30MHz~1GHz




    (C)Radiated Emission Test-Up Frequency Above 1GHz




`


                                        Page 18 of 31                   Report No.: NTEK- 2012NT1214549F


    3.4.5 TEST RESULTS (BLOW 30MHz)



     EUT:              Wireless digital PIR detector        Model Name. :             MC-8250R
     Temperature:      20 ℃                                 Relative Humidtity:       48%
     Pressure:         1010 hPa                             Test Voltage :            DC 3.0V
     Test Mode :       TX                                   Polarization :            --



             Freq.            Reading              Limit                     Margin          State
             (MHz)           (dBuV/m)           (dBuV/m)                      (dB)           P/F
               --                --                    --                      --           PASS
               --                --                    --                      --           PASS


    NOTE:

    The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible
    value has no need to be reported.
    Distance extrapolation factor =20 log (specific distance/test distance)(dB);
    Limit line = specific limits(dBuv) + distance extrapolation factor.




`


                                          Page 19 of 31           Report No.: NTEK- 2012NT1214549F


     3.4.6 TEST RESULTS (BETWEEN 30 – 1000 MHZ)

     EUT:              Wireless digital PIR detector   Model Name :       MC-8250R
     Temperature:      26 ℃                            Relative Humidity: 53%
     Pressure:         1020 hPa                        Test Power :       DC 3.0V
     Test Mode :       TX1
    The duty cycle is simply the on time divided by the period:
    The duration of one cycle = 73.5ms
    On time of one signal=0.425ms, DC = 0.425ms*37/73.5= 0.213
    Therefore, the average factor is found by 20log0.213 = -13.43dB
                                         The duration of one cycle




                                    On time and off time of one signal




        NOTE: The Peak value is less than AV limit already, the Duty Cycle evaluation is not required
        for mode 2.and 3.



`


                                     Page 20 of 31              Report No.: NTEK- 2012NT1214549F


    EUT:           Wireless digital PIR detector   Model Name :       MC-8250R
    Temperature:   20 ℃                            Relative Humidity: 48%
    Pressure:      1010 hPa                        Test Voltage :     DC 3.0V
    Test Mode :    TX1                             Polarization :     Horizontal

                    Average          Field             Field
       Frequency                                                  Limit(PK)   Limit(AV)
                     Factor        Strength          Strength
                                                                                          State
                                    dBuV/m           dBuV/m
         MHz           dB                                          dBuV/m     dBuV/m
                                     (PK)             (AV)

        433.980      -13.43          82.33            68.90        100.82      80.82      pass

       869.1301      -13.43          50.58            37.15         80.82      60.82      pass

       1737.500      -13.43          52.77              --          74.00      54.00      pass

       2175.000      -13.43          48.23              --          80.82      60.82      pass

          --           --              --               --          74.00      54.00      pass

          --           --              --               --          74.00      54.00      pass


    EUT:           Wireless digital PIR detector   Model Name :       MC-8250R
    Temperature:   20 ℃                            Relative Humidity: 48%
    Pressure:      1010 hPa                        Test Voltage :     DC 3.0V
    Test Mode :    TX1                             Polarization :     Vertical

                    Average           Field            Field
       Frequency                                                  Limit(PK)   Limit(AV)
                     Factor         Strength         Strength
                                                                                          State
                                    dBuV/m           dBuV/m
         MHz           dB                                          dBuV/m     dBuV/m
                                     (PK)             (AV)

        433.980      -13.43          79.92            66.49        100.82      80.82      pass

       869.1301      -13.43          49.34            35.91         80.82      60.82      pass

       1737.500      -13.43          45.84              --          74.00      54.00      pass

       2175.000      -13.43          52.33              --          80.82      60.82      pass

          --           --              --               --          74.00      54.00      pass

          --           --              --               --          74.00      54.00      pass




`


                                     Page 21 of 31              Report No.: NTEK- 2012NT1214549F


    EUT:           Wireless digital PIR detector   Model Name :       MC-8250R
    Temperature:   20 ℃                            Relative Humidity: 48%
    Pressure:      1010 hPa                        Test Voltage :     DC 3.0V
    Test Mode :    TX2                             Polarization :     Horizontal

                    Average          Field             Field
       Frequency                                                  Limit(PK)   Limit(AV)
                     Factor        Strength          Strength
                                                                                          State
                                    dBuV/m           dBuV/m
         MHz           dB                                          dBuV/m     dBuV/m
                                     (PK)             (AV)

        433.980        --            69.41              --         100.82      80.82      pass

       869.1301        --            49.58              --          80.82      60.82      pass

       1737.500        --            52.77              --          74.00      54.00      pass

       2175.000        --            48.23              --          80.82      60.82      pass

          --           --              --               --          74.00      54.00      pass

          --           --              --               --          74.00      54.00      pass


    EUT:           Wireless digital PIR detector   Model Name :       MC-8250R
    Temperature:   20 ℃                            Relative Humidity: 48%
    Pressure:      1010 hPa                        Test Voltage :     DC 3.0V
    Test Mode :    TX2                             Polarization :     Vertical

                    Average           Field            Field
       Frequency                                                  Limit(PK)   Limit(AV)
                     Factor         Strength         Strength
                                                                                          State
                                    dBuV/m           dBuV/m
         MHz           dB                                          dBuV/m     dBuV/m
                                     (PK)             (AV)

        433.980        --            68.32              --         100.82      80.82      pass

       869.1301        --            49.34              --          80.82      60.82      pass

       1737.500        --            45.84              --          74.00      54.00      pass

       2175.000        --            52.33              --          80.82      60.82      pass

          --           --              --               --          74.00      54.00      pass

          --           --              --               --          74.00      54.00      pass




`


                                        Page 22 of 31              Report No.: NTEK- 2012NT1214549F


    EUT:              Wireless digital PIR detector   Model Name :       MC-8250R
    Temperature:      20 ℃                            Relative Humidity: 48%
    Pressure:         1010 hPa                        Test Voltage :     DC 3.0V
    Test Mode :       TX3                             Polarization :     Horizontal

                        Average         Field             Field
        Frequency                                                    Limit(PK)   Limit(AV)
                         Factor       Strength          Strength
                                                                                             State
                                       dBuV/m           dBuV/m
          MHz             dB                                          dBuV/m     dBuV/m
                                        (PK)             (AV)

         433.980          --            67.41              --         100.82      80.82      pass

        869.1301          --            48.22              --          80.82      60.82      pass

        1737.500          --            43.31              --          74.00      54.00      pass

        2175.000          --            41.22              --          80.82      60.82      pass

            --            --              --               --          74.00      54.00      pass

            --            --              --               --          74.00      54.00      pass


    EUT:              Wireless digital PIR detector   Model Name :       MC-8250R
    Temperature:      20 ℃                            Relative Humidity: 48%
    Pressure:         1010 hPa                        Test Voltage :     DC 3.0V
    Test Mode :       TX3                             Polarization :     Vertical

                        Average          Field            Field
        Frequency                                                    Limit(PK)   Limit(AV)
                         Factor        Strength         Strength
                                                                                             State
                                       dBuV/m           dBuV/m
           MHz            dB                                          dBuV/m     dBuV/m
                                        (PK)             (AV)

         433.980           --           66.67              --         100.82      80.82      pass

         869.1301          --           49.54              --          80.82      60.82      pass

         1737.500          --           44.32              --          74.00      54.00      pass

         2175.000          --           40.12              --          80.82      60.82      pass

            --             --             --               --          74.00      54.00      pass


    Note:
    1. Emissions attenuated more than 20 dB below the permissible value are not reported.
    2. FCC Limit for Average Measurement = 41.6667(433.98)-7083.3333 = 10999.1811uV/m
       =80.82dBuV/m
    3. Field Strength(AV) = Field Strength(PK)+Average Factor.
    4. The signal bandwidth was measured and less then 100KHz RBW, so PDCF factor is not required..




`


                                       Page 23 of 31            Report No.: NTEK- 2012NT1214549F


    4. BANDWIDTH TEST


    4.1 TEST PROCEDURE

    The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices
    operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the
    emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the
    points 20 dB down from the modulated carrier.
    Limit: 433.98MHz*0.25%=1.08MHz


    4.2 DEVIATION FROM STANDARD

    No deviation.

    4.3 TEST SETUP




`


                                     Page 24 of 31           Report No.: NTEK- 2012NT1214549F


    4.4 TEST RESULTS

    EUT:           Wireless digital PIR detector   Model Name :       MC-8250R
    Temperature:   26 ℃                            Relative Humidity: 53%
    Pressure:      1020 hPa                        Test Power :       DC 3.0V
    Test Mode :    TX1


                                Frequency            20 dBc Bandwidth             Limit
        Test Channel
                                  (MHz)                   (MHz)                  (MHz)
           CH01                   433.98                  0.479                   1.08




`


                                     Page 25 of 31           Report No.: NTEK- 2012NT1214549F


    EUT:           Wireless digital PIR detector   Model Name :       MC-8250R
    Temperature:   26 ℃                            Relative Humidity: 53%
    Pressure:      1020 hPa                        Test Power :       DC 3.0V
    Test Mode :    TX2


                                Frequency            20 dBc Bandwidth             Limit
        Test Channel
                                  (MHz)                   (MHz)                  (MHz)
           CH01                   433.98                  0.533                   1.08




`


                                     Page 26 of 31           Report No.: NTEK- 2012NT1214549F


    EUT:           Wireless digital PIR detector   Model Name :       MC-8250R
    Temperature:   26 ℃                            Relative Humidity: 53%
    Pressure:      1020 hPa                        Test Power :       DC 3.0V
    Test Mode :    TX3


                                Frequency            20 dBc Bandwidth             Limit
        Test Channel
                                  (MHz)                   (MHz)                  (MHz)
           CH01                   433.98                  0.487                   1.08




`


                                         Page 27 of 31              Report No.: NTEK- 2012NT1214549F



    5. TRANSMITTER TIMEOUT

    5.1 REQUIREMENTS
                                                                                                           1
    47 CFR FCC Part 15 Subpart C, section 15.231(a)/(e):
     If devices complying with 47 CFR FCC Part 15 Subpart C, section 15.231(a).
     (1) A manually operated transmitter shall employ a switch that will automatically
     deactivate the transmitter within not more than 5 seconds of being released.
      (2) A transmitter activated automatically shall cease transmission within 5 seconds after
     activation.
      (3) Periodic transmissions at regular predetermined intervals are not permitted. However,
    polling or supervision transmissions, including data, to determine system integrity of transmitters
    used in security or safety applications are allowed if the total duration of transmissions does not
    exceed more than two seconds per hour for each transmitter. There is no limit on the number of
    individual transmissions, provided the total transmission time does not exceed two seconds per
    hour.
    (4) Intentional radiators which are employed for radio control purposes during emergencies
     involving fire, security, and safety of life, when activated to signal an alarm, may operate during
     the pendency of the alarm condition.
     (5) Transmission of set-up information for security systems may exceed the transmission
    duration limits in paragraphs 15.231(a) of this section, provided such transmission are under the
    control of a professional installer and do not exceed ten seconds after a manually operated switch
    is released or a transmitter is activated automatically. Such set-up information may include data.
     If devices complying with 47 CFR FCC Part 15 Subpart C, section 15.231(e)
     Intentional radiators may operate at a periodic rate exceeding that specified in section 15.231(a)
     and may be employed for any type of operation, including operation prohibited section
     15.231(a).




`


                                      Page 28 of 31             Report No.: NTEK- 2012NT1214549F


    EUT:            Wireless digital PIR detector     Model Name :       MC-8250R
    Temperature:    26 ℃                              Relative Humidity: 53%
    Pressure:       1020 hPa                          Test Power :       DC 3.0V
    Test Mode :     TX1

                                              Test data




           THE DURATION OF
                                                LIMIT                      RESULT
          EACH TRANSMISSION

                   0.587s                           <5s                      PASS

          A manually operated transmitter shall employ a switch that will automatically
          deactivate the transmitter within not more than 5 seconds of being released.




`


                                       Page 29 of 31             Report No.: NTEK- 2012NT1214549F


    EUT:             Wireless digital PIR detector     Model Name :       MC-8250R
    Temperature:     26 ℃                              Relative Humidity: 53%
    Pressure:        1020 hPa                          Test Power :       DC 3.0V
    Test Mode :      TX2

                                               Test data




           THE DURATION OF
                                                LIMIT                     RESULT
          EACH TRANSMISSION

                   0.575s                            <5s                    PASS

         A transmitter activated automatically shall cease transmission within 5 seconds
         afteractivation.
         (Every hour a short "supervision" message whose duration 575 msec is emitted
         about battery information)




`


                                      Page 30 of 31             Report No.: NTEK- 2012NT1214549F


    EUT:            Wireless digital PIR detector     Model Name :       MC-8250R
    Temperature:    26 ℃                              Relative Humidity: 53%
    Pressure:       1020 hPa                          Test Power :       DC 3.0V
    Test Mode :     TX3

                                              Test data




           THE DURATION OF
                                                LIMIT                      RESULT
          EACH TRANSMISSION

                   0.562s                           <5s                      PASS

          A manually operated transmitter shall employ a switch that will automatically
          deactivate the transmitter within not more than 5 seconds of being released.




`


                            Page 31 of 31      Report No.: NTEK- 2012NT1214549F


    6. EUT TEST PHOTO

                        Radiated Measurement Photos




`



Document Created: 2013-01-11 09:20:19
Document Modified: 2013-01-11 09:20:19

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC