XM19050029E01_FCC_Part15B

FCC ID: QMH-XL9192

Test Report

Download: PDF
FCCID_4424708

                                                                                     REPORT No.:XM19050029E01




                                    TEST REPORT

            APPLICANT                      : Xingtel Xiamen Group Co., Ltd.

            PRODUCT NAME                   : Facial Recognition Door Lock

            MODEL NAME                     : XL-9192

            BRAND NAME                     : N/A

            STANDARD(S)                    : 47 CFR Part 15 Subpart B

            TEST DATE                      : 2019-07-15 to 2019-07-17

            ISSUE DATE                     : 2019-07-19




                                                      Prepared by:
                                                                                Qijie Xiao(Test engineer)


                                                      Approved by:
                                                                                Anne Liu (Supervisor)

NOTE: 1.The report is invalid when there is no the approver signature and the special stamp for test report. 2.The test report
shall not be reproduced except in full without prior written permission of the company. 3.The report copy is invalid when there is
no the special stamp for test report. 4.The altered report is invalid. 5.The entrust test is responsibility for the received sample
only.

Kehu-Morlab             XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                                             Tel: +86 592 5612050
Test Laboratory         Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095


                                                                                       REPORT No.:XM19050029E01


                                                     DIRECTORY
 1. Technical Information ············································································································2
 1.1. Applicant and Manufacturer Information ········································································2
 1.2. Equipment Under Test (EUT) Description·······································································2
 2. Test Results ·····························································································································3
 2.1. Applied Reference Documents ·························································································3
 2.2. EUT Setup and Operating Conditions ·············································································4
 3. 47 CFR Part 15B Requirements ···························································································5
 3.1. Conducted Emission···········································································································5
 Radiated Disturbance···················································································································9
 Annex A Test Uncertainty ········································································································15
 Annex B Testing Laboratory Information ············································································16




                                                          Change History
              Issue                              Date                                     Reason for change
                1.0                         2019-07-19                                          First edition




Kehu-Morlab                                                                                                            Tel: +86 592 5612050
                         XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory          Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                                 Page1 0f 17


                                                                                REPORT No.:XM19050029E01


 1. Technical Information
 Note: Provide by applicant.

 1.1. Applicant and Manufacturer Information
   Applicant:                         Xingtel Xiamen Group Co., Ltd.
   Applicant Address:                 Xingtel Building,Chuangxin Road, Torch Hi-Tech Industrial
                                      District,Xiamen 361006, PR China
   Manufacturer:                      Xingtel Xiamen Group Co., Ltd.
   Manufacturer Address:              Xingtel Building,Chuangxin Road, Torch Hi-Tech Industrial
                                      District,Xiamen 361006, PR China


 1.2. Equipment Under Test (EUT) Description

  EUT Type:                    Facial Recognition Door Lock
  Serial No:                   (N/A, marked #1 by test site)
  Hardware Version:            S3_1V4
  Software Version:            1.0.9 Z6
  Accessory                    Battery
  Information                  Brand Name:                   GP
                               Model No:                     GN15A
                               Serial No:                    N/A
                               Capacity:                     N/A
                               Rated Voltage:                1.5V
                               Number:                       8
  Ancillary                    Adapter
  Equipment:                   Manufacturer:                 Xiamen Meitu Mobile Technology Co.,Ltd.
                               Brand Name:                   Apple
                               Model No.:                    MA-1804
                               Serial No.:                   CY84V1000140


 Note:

 1.   For a more detailed description, please refer to specification or user’s manual supplied by the
      applicant and/or manufacturer




Kehu-Morlab                                                                                                      Tel: +86 592 5612050
                   XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory    Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                          Page2 0f 17


                                                                                REPORT No.:XM19050029E01

 2. Test Results
 2.1. Applied Reference Documents
 The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:

          No.     Identity                                       Document Title
          1       47 CFR Part 15 Subpart B                       Radio Frequency Devices

 Test detailed items/section required by FCC rules and results are as below:

      No.     Section      Description                       Test Date             Test Engineer            Result
      1       15.107       Conducted Emission                July.16 2019          Qijie Xiao               PASS
      2       15.109       Radiated Emission                 July.16 2019          Qijie Xiao               PASS

 NOTE: The tests were performed according to the method of measurements prescribed in ANSI
 C63.4-2014.




Kehu-Morlab                                                                                                      Tel: +86 592 5612050
                   XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory    Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                          Page3 0f 17


                                                                                REPORT No.:XM19050029E01

 2.2. EUT Setup and Operating Conditions
 Frequency range was investigated: Conducted emission test: from 150KHz to 30MHz; Radiated
 emission test: from 30MHz to 1000MHz.
  Test Item
  Radiated Emission
  Mode 1      : EUT(Face recognition mode)
  Mode 2      : EUT(Face recognition mode )+ADAPTER
  Conducted Emission
  Mode 1      : EUT(Face recognition mode)+ADAPTER


 During the measurement, the environmental conditions were within the listed ranges:

  Temperature (°C):                                              15 - 35
  Relative Humidity (%):                                         30 - 60
  Atmospheric Pressure (kPa):                                    86 - 106




Kehu-Morlab                                                                                                      Tel: +86 592 5612050
                   XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory    Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                          Page4 0f 17


                                                                                   REPORT No.:XM19050029E01


 3.        47 CFR Part 15B Requirements
 3.1. Conducted Emission
 3.1.1.    Requirement

 According to FCC section 15.107, the radio frequency voltage that is conducted back onto the AC
 power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the
 following table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).

     Frequency range                                              Conducted Limit (dBµV)
          (MHz)                                   Quasi-peak                                            Average
          0.15 - 0.50                                66 to 56                                           56 to 46
           0.50 - 5                                      56                                                 46
            5 - 30                                       60                                                 50
      NOTE:
      a) The limit subjects to the Class B digital device.
      b) The lower limit shall apply at the band edges.
      c) The limit decreases linearly with the logarithm of the frequency in the range 0.15 -
      0.50MHz.


 3.1.2.    Test Setup




 The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
 and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power



Kehu-Morlab                                                                                                         Tel: +86 592 5612050
                      XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory       Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                             Page5 0f 17


                                                                               REPORT No.:XM19050029E01

 mains through a LISN which provides 50Ω/50µH of coupling impedance for the measuring
 instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole
 test system are calibrated to correct the reading.

 The power strip or extension cord has been investigated to make sure that the LISN integrity in
 maintained with respect to the impedance characteristics as prescribed in ANSI C63.4-2014       at
 Clause 4.3.


 3.1.3.   Test Result

 The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average
 (AV) detectors; the emission levels more than the AV and QP limits, and that have narrow margins
 from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase
 and N phase lines of the power mains connected to the EUT are performed. All test modes are
 considered, refer to recorded points and plots below.




Kehu-Morlab                                                                                                     Tel: +86 592 5612050
                  XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                         Page6 0f 17


                                                                                         REPORT No.:XM19050029E01

 A. Test Plot and Suspicious Points:

     Test Mode 1:
          Level in dBμ




                                                             (Plot A: L Phase)




Frequency                Quasi-peak        MaxPeak            Average          Limit        Margin                   Corr.       Verdi
                                                                                                           Line
  (MHz)                   (dBµV)            (dBµV)             (dBµV)         (dBµV)         (dB)                    (dB)         ct
 0.346000                    ---               ---              18.16          49.06          30.90         L1        10.2       PASS
 0.346000                    ---              29.11              ---           59.06          29.95         L1        10.2       PASS
 0.922000                    ---               ---              17.80          46.00          28.20         L1        10.3       PASS
 0.922000                    ---              28.22              ---           56.00          27.78         L1        10.3       PASS
 2.550000                    ---               ---              18.89          46.00          27.11         L1        10.3       PASS
 2.550000                    ---              30.65              ---           56.00          25.35         L1        10.3       PASS
 5.238000                    ---               ---              21.03          50.00          28.97         L1        10.4       PASS
 5.238000                    ---              31.44              ---           60.00          28.56         L1        10.4       PASS
13.094000                    ---               ---              36.89          50.00          13.11         L1        10.7       PASS
13.094000                    ---              40.89              ---           60.00          19.11         L1        10.7       PASS
16.378000                    ---               ---              25.87          50.00          24.13         L1        10.7       PASS
16.378000                    ---              33.46              ---           60.00          26.54         L1        10.7       PASS




Kehu-Morlab                                                                                                               Tel: +86 592 5612050
                            XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory             Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                                   Page7 0f 17


                                                                                        REPORT No.:XM19050029E01


          Level in dBμ




                                                           (Plot B: N Phase)




  Frequency              Quasi-peak          MaxPeak            Average          Limit        Margin                     Corr.     Verdi
                                                                                                             Line
     (MHz)                (dBµV)              (dBµV)             (dBµV)         (dBµV)         (dB)                      (dB)       ct
   0.450000                 ---                 ---               18.71          46.88        28.16            N         10.2      PASS
   0.450000                 ---                29.99               ---           56.88        26.89            N         10.2      PASS
   0.970000                 ---                 ---               18.56          46.00        27.44            N         10.3      PASS
   0.970000                 ---                29.73               ---           56.00        26.27            N         10.3      PASS
   1.994000                 ---                 ---               18.80          46.00        27.20            N         10.3      PASS
   1.994000                 ---                29.01               ---           56.00        26.99            N         10.3      PASS
   4.882000                 ---                 ---               20.08          46.00        25.92            N         10.4      PASS
   4.882000                 ---                31.69               ---           56.00        24.31            N         10.4      PASS
   9.834000                 ---                 ---               25.79          50.00        24.21            N         10.6      PASS
   9.834000                 ---                34.97               ---           60.00        25.03            N         10.6      PASS
  13.114000                 ---                 ---               36.76          50.00        13.24            N         10.7      PASS
  13.114000                 ---                40.73               ---           60.00        19.27            N         10.7      PASS




Kehu-Morlab                                                                                                              Tel: +86 592 5612050
                           XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory            Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                                  Page8 0f 17


                                                                               REPORT No.:XM19050029E01

 Radiated Disturbance

 3.1.4. Requirement

 According to FCC section 15.205, the field strength of radiated emissions from intentional radiators
 at a distance of 3 meters shall not exceed the following values:
                                                                         Field Strength
   Frequency range (MHz)
                                                       µV/m                                          dBµV/m
            30 - 88                                     100                                              40
            88 - 216                                    150                                             43.5
          216 - 960                                     200                                              46
          Above 960                                     500                                              54
 NOTE: a)     Field Strength (dBµV/m) = 20*log[Field Strength (µV/m)].
       b)     In the emission tables above, the tighter limit applies at the band edges.




 3.1.5. Test Setup

 For radiated emissions from 30MHz to 1GHz




Kehu-Morlab                                                                                                     Tel: +86 592 5612050
                  XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                         Page9 0f 17


                                                                               REPORT No.:XM19050029E01

 The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of
 the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating
 Turn Table, and keeps 3m away from the Test Antenna, which is mounted on a variable-height
 antenna master tower.

 For the test Antenna:

 In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) are used. Test
 Antenna is 3m away from the EUT. Test Antenna height is varied from 1m to 4m above the ground
 to determine the maximum value of the field strength. The emission levels at both horizontal and
 vertical polarizations should be tested.


 3.1.6.   Test Result

 The maximum radiated emission is searched using PK, QP detectors; the emission levels more
 than the limits, and that have narrow margins from the limits will be re-measured with QP detectors.
 Both the vertical and the horizontal polarizations of the Test Antenna are considered to perform the
 tests. All test modes are considered, refer to recorded points and plots below.




Kehu-Morlab                                                                                                     Tel: +86 592 5612050
                  XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                        Page10 0f 17


                                                                               REPORT No.:XM19050029E01

     Test mode 1:



                      Level in dBμV/




                                       (Plot A: ANT-Vertical,30MHz - 1GHz)




Frequency         MaxPeak              Quasi Peak            Limit               Margin                      Corr.
                                                                                                 Pol                        Verdict
  (MHz)           (dBμV/m               (dBμV/m)           (dBμV/m)               (dB)                      (dB/m)
 43.822500         19.09                   ---                40.00               20.91            V            15.3         PASS
105.619583         17.40                   ---                43.50               26.10            V            14.2         PASS
200.679583         18.12                   ---                43.50               25.38            V            14.2         PASS
345.694583         22.06                   ---                46.00               23.94            V            18.1         PASS
529.428750         26.39                   ---                46.00               19.61            V            22.2         PASS
769.301667         31.80                   ---                46.00               14.20            V            26.2         PASS




Kehu-Morlab                                                                                                     Tel: +86 592 5612050
                  XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                        Page11 0f 17


                                                                               REPORT No.:XM19050029E01




                      Level in dBμV/




                                       (Plot B:ANT- Horizontal, 30MHz - 1GHz)




Frequency         MaxPeak               Quasi Peak           Limit               Margin                      Corr.
                                                                                                 Pol                        Verdict
  (MHz)           (dBμV/m                (dBμV/m)          (dBμV/m)               (dB)                      (dB/m)
 50.450833         19.51                     ---              40.00               20.49            H            16.1         PASS
109.944167         18.28                     ---              43.50               25.22            H            14.9         PASS
200.477500         18.76                     ---              43.50               24.74            H            14.3         PASS
318.898333         23.59                     ---              46.00               22.41            H            17.8         PASS
440.310000         26.90                     ---              46.00               19.10            H            20.6         PASS
728.885000         32.53                     ---              46.00               13.47            H            25.3         PASS




Kehu-Morlab                                                                                                     Tel: +86 592 5612050
                  XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                        Page12 0f 17


                                                                               REPORT No.:XM19050029E01

     Test mode 2:



                      Level in dBμV/




                                       (Plot A: ANT-Vertical,30MHz - 1GHz)




Frequency         MaxPeak              Quasi Peak            Limit               Margin                      Corr.
                                                                                                 Pol                        Verdict
  (MHz)           (dBμV/m               (dBμV/m)           (dBμV/m)               (dB)                      (dB/m)
 49.036250         19.29                   ---             49.036250              19.29            V            15.6         PASS
103.922083         18.58                   ---            103.922083              18.58            V            14.3         PASS
198.335417         18.66                   ---            198.335417              18.66            V            14.0         PASS
290.566250         19.89                   ---            290.566250              19.89            V            15.8         PASS
446.332083         24.96                   ---            446.332083              24.96            V            19.7         PASS
759.561250         32.03                   ---            759.561250              32.03            V            26.2         PASS




Kehu-Morlab                                                                                                     Tel: +86 592 5612050
                  XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                        Page13 0f 17


                                                                               REPORT No.:XM19050029E01




                     Level in dBμV/




                                      (Plot B:ANT- Horizontal, 30MHz - 1GHz)




Frequency         MaxPeak              Quasi Peak            Limit               Margin                      Corr.
                                                                                                 Pol                        Verdict
  (MHz)           (dBμV/m               (dBμV/m)           (dBμV/m)               (dB)                      (dB/m)
 56.392083         18.15                    ---               40.00               21.85            H            14.7         PASS
 90.220833         17.59                    ---               43.50               25.91            H            13.3         PASS
154.160000         15.65                    ---               43.50               27.85            H            10.8         PASS
281.917083         20.92                    ---               46.00               25.08            H            16.4         PASS
500.369167         26.98                    ---               46.00               19.02            H            22.0         PASS
728.440417         31.71                    ---               46.00               14.29            H            25.3         PASS




Kehu-Morlab                                                                                                     Tel: +86 592 5612050
                  XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                        Page14 0f 17


                                                                               REPORT No.:XM19050029E01

       Annex A Test Uncertainty
 The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
 Uncertainty in Measurement" (GUM) published by ISO.

 Uncertainty of Conducted Emission Measurement

  Measuring Uncertainty for
  a Level of Confidence of 150kHz-30MHz                                              ±2.61dB
  95%(U=2Uc(y))

 Uncertainty of Radiated Emission Measurement

  Measuring Uncertainty for 30MHz-200MHz                                             ±3.87dB
  a Level of Confidence of
                            200MHz-1000MHz                                           ±4.07dB
  95%(U=2Uc(y))




Kehu-Morlab                                                                                                     Tel: +86 592 5612050
                  XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                        Page15 0f 17


                                                                               REPORT No.:XM19050029E01

        Annex B Testing Laboratory Information
 1. Identification of the Responsible Testing Laboratory

   Department:                            Kehu-Morlab Test Laboratory
   Address:                               Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free
                                          Trade Zone (Fujian) China
   Responsible      Test        Lab
                                          Mr. Di Dehai
   Manager:
   Telephone:                             +86 592 5612050
   Facsimile:                             +86 592 5612095

 2. Identification of the Responsible Testing Location

   Name:                                  Kehu-Morlab Test Laboratory
                                          Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free
   Address:
                                          Trade Zone (Fujian) China

 3. Accreditation Certificate

   Accredited Testing                     The FCC designation number is CN1249.
   Laboratory:                            ( Kehu-Morlab Test Laboratory )

 4. Test Equipment Utilized

 List of Software Used
  No.                 Model                           Version Number                    Producer                  Test Item
    1                EMC 32                                V10.00.00                        R&S                       RE
    2                EMC 32                                V10.20.01                        R&S                       CE


 Conducted Emission Test Equipments
 No.    Equipment Name             Serial No.           Model           Manufacturer              Cal.Date            Cal.Due
                                                         No.                                                           Date
  1       EMI Receiver               102174             ESR3                 ESR3               2019.01.08          2020.01.07
  2           LISN                   101338            ENV432               ENV432              2019.01.14          2020.01.13
          Pulse Limiter                                 VTSD
  3                                    317                              VTSD 9561 F             2019.01.03          2020.01.02
             (10dB)                                    9561 F
             Coaxial
  4        cable(BNC)                EMC01                N/A                Morlab                   N/A                N/A
         (30MHz-3GHz)




Kehu-Morlab                                                                                                     Tel: +86 592 5612050
                  XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                        Page16 0f 17


                                                                               REPORT No.:XM19050029E01




 Radiated Test Equipments
                                                                                                                      Cal.Due
 No.   Equipment Name            Serial No.          Model No.          Manufacturer             Cal. Date
                                                                                                                       Date
  1    Anechoic Chamber               N/A           9m*6m*6m            ETS-Lindgren            2017.07.21          2020.07.20
  2         Receiver                 R&S                ESR7                 101799             2019.01.07          2020.01.06
          Linear Log
  3      Periodic Broad               949           VULB 9163           Schwarzbeck             2018.09.25          2019.09.24
         Band Antenna
          Coaxial cable
  4         (N male)               EMC03                  N/A                Morlab                  N/A                 N/A
          (9kHz -3GHz)




                                                 END OF REPORT




Kehu-Morlab                                                                                                     Tel: +86 592 5612050
                  XIAMEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.
Test Laboratory   Unit 101, No.1732 Gangzhong Road, Xiamen Area, Pilot Free Trade Zone (Fujian) , P. R. China   Fax: +86 592 5612095
                                                                                                                        Page17 0f 17



Document Created: 2019-08-14 09:34:48
Document Modified: 2019-08-14 09:34:48