Test Report

FCC ID: QLE-GWAV8141KRX

Test Report

Download: PDF
FCCID_1289617

                                                                                     www.kes.co.kr



                             TEST REPORT For FCC
  Test Report No.                   : TK-FR10020


  Date of Issue                     : 05/24/2010


  Description of Product            : Wireless HD Kit



  Model No.                         :   GWAV8141K


  Applicant                         :   ATEN Technology, Inc., bda IOGEAR, bda IOGEAR
                                        19641 Da Vinci, Foothill Ranch, California 92610, USA



  Manufacturer                      :   I DO IT CO.,LTD.
                                        1308 WoolimLions 2nd, Doksan Station St. 122,
                                        Geumcheon-Gu, Seoul, KOREA, 153-787

  Standards                         : FCC Part 15 Subpart E §15.407


  Test Date                         : 05/11/2010 ~ 05/24/2010


  Test Results                      :       PASS                              FAIL

  The test results relate only to the items tested.


  Tested by:                                                        Reviewed by:
                  Kyu-Chul Shin                                                KT Kang
                  Test Engineer                                                Technical Manager
                  Date:05/24/2010                                              Date: 05/24/2010



                                THRU-KES CO.,LTD.
                 477-6, Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do,469-803, Korea
                         Tel: +82-31-425-6200 / Fax: +82-31-424-0450



Test Report No.: TK-FR10020                                                                    Page 1 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                                   www.kes.co.kr



                                         TABLE OF CONTENTS
1.0     General Product Description ............................................................................... 3
1.1     Tested Frequency ............................................................................................. 3
1.2     Model Differences ............................................................................................. 4
1.3     Device Modifications ......................................................................................... 4
1.4     Peripheral Devices ............................................................................................ 4
1.5     Calibration Details of Equipment Used for Measurement ......................................... 4
1.6     Test Facility...................................................................................................... 4
2.0     Summary of tests ............................................................................................. 5
2.1 Technical Characteristic Test ..................................................................................... 6
    2.1.1   26dB Bandwidth - 15.407(a) ........................................................................ 6
    2.1.2   Maximum peak Conducted Output Power-15.407(a)......................................... 8
    2.1.3   Power Spectral Density-15.407(a) ............................................................... 12
    2.1.4   Peak Excursion Measurement -15.407(a).................................................... 14
    2.1.5   Radiated Emissions Measurement................................................................ 16
    2.1.6 Frequency Stability Measurement 15.407(g) ................................................... 21
    2.1.8   AC Conducted Emissions 15.207 ................................................................. 23
APPENDIX A – Test Equipment Used For Tests ................................................................ 26




Test Report No.: TK-FR10020                                                                    Page 2 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr


1.0     General Product Description


         Equipment model name            : GWAV8141K

         Serial number                    : Prototype

         EUT condition                   : Pre-production, not damaged
                                         : Internal Antenna (Supporting MIMO) :
         Antenna type
                                           Patch antenna       Gain 0.667dBi
         Frequency Range                 : 5150MHz ~ 5250MHz(OFDM)

         RF output power                 : 12.98 dBm Peak Conducted (40MHz)

         Number of channels              :2

         Channel Spacing                 : 40 MHz

         Transfer Rate                   : 270Mbps

         Type of Modulation               : 64-QAM for OFDM

         Power Source                    : DC 12V




                                        Ant. A-1            ANT. A-2



1.1     Tested Frequency

                                                    38ch                         46ch
         Frequency (MHz)
                                                     5190                        5230




Test Report No.: TK-FR10020                                                                    Page 3 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                       www.kes.co.kr




1.2        Model Differences
           -

1.3        Device Modifications
           The following modifications were necessary for compliance:
           Not applicable




1.4        Peripheral Devices
      Device           Manufacturer             Model No.            Serial No.    FCC ID or
                                                                                   DoC
EUT                 ATEN Technology, Inc.,     GWAV8141K                           -
                                                                 -
                    dba IOGEAR

Notebook            F U J I T S U      L T D   LIFEBOOK S-5582   434230343466      DoC




1.5        Calibration Details of Equipment Used for Measurement
           Test equipment and test accessories are calibrated on regular basis. The maximum
           time between calibrations is one year or what is recommended by the manufacturer,
           whichever is less. All test equipment calibrations are traceable to the Korea Research
           Institute of Standards and Science (KRISS), therefore, all test data recorded in this
           report is traceable to KRISS.

1.6        Test Facility
       THRU-KES Co.,Ltd. (Test Site # : 343818)
       477-6, Hager-Ri, Yoju-Up, Yoju-Gun Kyunggi-Do,469-803, Korea




Test Report No.: TK-FR10020                                                                    Page 4 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr



2.0     Summary of tests

         FCC Part                                                                        Status
                                   Parameter                          Limit
        Section(s)                                                                      (note 1)

        15.407(a)        26dB Spectrum Bandwidth             -                              C
                         Maximum Conducted Output
        15.407(a)                                            < 50mW                         C
                         Power
        15.407(a)        Power Spectral Density              > 4 dBm                        C

        15.407(a)        Peak Excursion                      > 13 dB                        C

                                                                                            C
        15.407(b)        Radiated Emissions                  < -27dBm @ EIRP
                                                                                            C
        15.407(b)        Band Edge Emissions                 < 80 dBuV                      C

        15.407(g)        Frequency Stability                 20ppm                          C
                         AC Power Line Conducted
          15.207                                             EN 55022                       C
                         Emissions

        The sample was tested according to the following specification:
        - FCC Part 15.407, ANSI C63.4-2003




Test Report No.: TK-FR10020                                                                    Page 5 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr



2.1 Technical Characteristic Test
2.1.1 26dB Bandwidth - 15.407(a)

    Procedure:
    1. The transmitted output (antenna port) was connected to the spectrum analyzer in peak
       hold mode
    2. The resolution bandwidth of 300kHz and the video bandwidth of 1000kHz were used
    3. Measured the spectrum width with power higher than 26dB below carrier
    4. Measuring multiple antenna, the connector is required to link with spectrum analyzer
       through a combiner


    The spectrum analyzer is set to:
    Center frequency = 38ch , 46ch
    RBW = 300 kHz                                        Span = >26dB Bandwidth
    VBW = 1000 kHz                                       Sweep = auto
    Trace = max hold                                     Detector function = peak


  -26dB Bandwidth
   Configuration Draft n Ant. A-1+A-2

                                                                   Test Results
                Frequency       Channel
    Mode
                  (MHz)           No.            26dB Bandwidth                  99% Occupied
                                                     (MHz)                      Bandwidth(MHz)

                   5190            38                   38.08                           35.20
  n Mode
                   5230            46                   38.40                           35.36



  - See next pages for actual measured spectrum plots.
   Limit:
   No restriction limits.




Test Report No.: TK-FR10020                                                                    Page 6 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr


    26dB Bandwidth Plot on Configuration Draft n 40MHz ANT. A-1+A-2/5190MHz




    26dB Bandwidth Plot on Configuration Draft n 40MHz ANT. A-1+A-2/5190MHz




Test Report No.: TK-FR10020                                                                    Page 7 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                       www.kes.co.kr


2.1.2 Maximum peak Conducted Output Power-15.407(a)

Test Location

        RF Test Room

      Procedures

      The transmitter output is connected to a spectrum analyzer and the analyzer’s internal
      channel power integration function is used to integrate the power over a bandwidth
      greater than or equal to the 99% bandwidth.




              EUT                                          Spectrum Analyzer




        Test Results

       Configuration Draft n 40MHz ANT. A-1
             Frequency                     Peak output
                              Channel No.                                      Limit              Result
               (MHz)                       power(dBm)
                    5190                  38               8.09          17dBm(50mW)            Complies
                    5230                  46               6.19          17dBm(50mW)            Complies

        Configuration Draft n 40MHz ANT. A-2
              Frequency                    Peak output
                               Channel No.                                     Limit              Result
                (MHz)                      power(dBm)
                    5190                  38               6.73          17dBm(50mW)            Complies
                    5230                  46               5.37          17dBm(50mW)            Complies

        Configuration Draft n 40MHz ANT. A-1+A-2
              Frequency                    Peak output
                               Channel No.                                     Limit              Result
                (MHz)                      power(dBm)
                    5190                  38              12.39          17dBm(50mW)            Complies
                    5230                  46              12.98          17dBm(50mW)            Complies

        See next pages for actual measured spectrum plots.

        Limit : < 17dBm




Test Report No.: TK-FR10020                                                                    Page 8 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr


Peak Conducted Output Power Plot on Configuration Draft n 40MHz ANT. A-1/5190




 Peak Conducted Output Power Plot on Configuration Draft n 40MHz ANT. A-1/5230




Test Report No.: TK-FR10020                                                                    Page 9 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr


Peak Conducted Output Power Plot on Configuration Draft n 40MHz ANT. A-2/5190




 Peak Conducted Output Power Plot on Configuration Draft n 40MHz ANT. A-2/5230




Test Report No.: TK-FR10020                                                                   Page 10 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr


Peak Conducted Output Power Plot on Configuration Draft n 40MHz ANT. A-1+A2/5190




    Peak Conducted Output Power Plot on Configuration Draft n 40MHz ANT. A-1+A2/5230




Test Report No.: TK-FR10020                                                                   Page 11 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr



2.1.3 Power Spectral Density-15.407(a)

Procedure:
  The peak power density is measured with a spectrum analyzer connected to the antenna
terminal while the EUT is operating in transmission mode at the appropriate frequencies.

    The spectrum analyzer is set to:
    RBW = 1000 kHz                             VBW = 3000kHz
    Sweep = Auto                               Span = 60 MHz
    Detector function = Sample                 Trace = Average




  Measurement Data:


 Configuration Draft n 40MHz ANT. A-1+A2



                     Frequency                                             Test Results
     Mode                                     Ch.
                       (MHz)
                                                                   dBm                     Result

                         5190                 38                   -5.72                  Complies
    n Mode
                         5230                 46                  -10.23                  Complies




   Limit:

   Power Spectral Density        < 4dBm



  See next pages for actual measured spectrum plots.




Test Report No.: TK-FR10020                                                                   Page 12 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr


         Power Density Plot on Configuration Draft n 40MHz ANT. A-1+A2/5190




         Power Density Plot on Configuration Draft n 40MHz ANT. A-1+A2/5230




Test Report No.: TK-FR10020                                                                   Page 13 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr



2.1.4 Peak Excursion Measurement -15.407(a)

Procedure:

    1. The transmitter Output(antenna port) was connected to the spectrum analyzer
    2. Set the spectrum analyzer span to view the entire emissions bandwidth. The largest
       difference between the following two traces (Peak Trace and Average Trace) must be
       ≤13 dB for all frequencies across the emissions bandwidth. Submit a plot.
    3. Peak Trace : Set RBW=1MHz, VBW≥3MHz with peak detector and max-hold settings
    4. Average Trace: Method #3-vido averaging with max hold and sum power across the
       band. Set span to encompass the entire emissions bandwidth[EBW] of the signal.
       Set sweep trigger to ‘free run’. Set RBW=1MHz. Set VBW ≥ 1/T(Draft n VBW=300kHz
       ≥1/4㎲). Use sample detector mode if bin width(i.e.,span/number of points in spectrum)
       <0.5RBW. Otherwise use peak detector mode. Set max hold. Allow max hold to run for 60
       seconds.
    5. Measuring multiple antennas, the connector is required to link with spectrum analyzer through
       a combiner

    The spectrum analyzer is set to:
    RBW = 1000 kHz(Peak Trace) / 1000kHz(Average Trace)
    VBW = 3000 kHz(Peak Trace) / 300kHz(Average Trace)
    Detector function = Peak (Peak Trace) /         Sample (Average Trace)
    Trace = Max hold
    Sweep = 60s
    Span Frequency = Encompass the entire emissions bandwidth (EBW) of the signal


  Measurement Data:


 Configuration Draft n 40MHz ANT. A-1+A2

                     Frequency                                             Test Results
     Mode                                     Ch.
                       (MHz)
                                                                    dB                     Result

                         5190                 38                   5.20                   Complies
    n Mode
                         5230                 46                   5.19                   Complies



   Limit
   Peak Excursion:                  13dB



  See next pages for actual measured spectrum plots.
Test Report No.: TK-FR10020                                                                   Page 14 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr


        Peak Excursion Plot on Configuration Draft n 40MHz ANT. A-1+A2/5190




        Peak Excursion Plot on Configuration Draft n 40MHz ANT. A-1+A2/5230




Test Report No.: TK-FR10020                                                                   Page 15 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr


2.1.5 Radiated Emissions Measurement

        Test Location
            Testing was performed at a test distance of 3 meter Open Area Test Site

        Test Procedures
        The height of the measuring antenna was varied between 1 to 4 m and the table was
        rotated a full revolution in order to obtain maximum values of the electric field intensity.
        The measurement was made in both the vertical and horizontal polarization, and the
        maximum value is presented in the report.

        The spectrum analyzer is set to:
        Below 1GHz :
                    RBW=100KHz/VBW=300KHz/Sweep=AUTO
        Above 1GHz:
                   (a) PEAK:RBW=VBW=1MHz/Sweep=AUTO
                   (b) AVERAGE:RBW=1MHz/VBW=10Hz/Sweep=AUTO




Note : The amplitudes of spurious emissions that are attenuated more than 20dB below the
        limit have not been reported




Test Report No.: TK-FR10020                                                                   Page 16 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr




        Limit

         -15.407(b) (1)
          For transmitters operating in the 5.15~5.35 GHz band: all emissions outside of the
          5.15 ~ 5.35GHz band shall not exceed an EIRP of -27dBm/MHz [80 dBuV/m@3m]

        - 15.209(a),15.205
             Frequency(MHz)          Field Strength uV/m@3m         Field Strength dBuV/m@3m
                 30-88                        100**                              40
                88-216                        150**                             43.5
                216-960                       200**                              46
               Above 960                       500                               80

         ** Except as provided in 15.209(g).fundamental emissions from intentional radiators
         operating under this Section shall not be located in the frequency bands 54-72MHz,
         76-88MHz, 174-216MHz, 470-806MHz. However, operation within these frequency
         bands is permitted under other sections of this Part, e.g.15.231 and 15.241.




Test Report No.: TK-FR10020                                                                   Page 17 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                       www.kes.co.kr



Test Results

 EUT            Wireless HD Kit                 Measurement Detail
 Model          GWAV8141K                       Frequency Range              Below 1000MHz
 Channel        -                               Detector function            Quasi-Peak

        The requirements are:

            Complies
          Frequency                 Measured Data          Margin
                                                                                        Remark
            (MHz)                     (dBuV/m)              (dB)
             49.8                       38.7                -1.3                       Quasi-Peak


        Test Data

                                                                  Field
              Emission      Meter        Ant.   Correction Cable
                                                                 Strengt       Margin      Limit
          No Frequency     Reading     Polaritr   Factor    Loss
                                                                    h          (dBuv)    (dBuv/m)
               (MHz)        dBuV/m         y        dB       dB
                                                                 (dBuv/m
            1     49.80      21.2         V         13.6      4.0     38.7      -1.3      40.0
            2    125.10      22.9         H         12.5      2.4     37.8      -5.7      43.5
            3    200.24      23.3         H          9.9      2.9     36.1      -7.4      43.5
            4    462.50      23.2         H         16.0      4.1     43.3      -2.7      46.0
            5    466.99      23.8         V         16.1      4.1     44.0      -2.0      46.0
            6    467.20      24.3         H         16.1      4.1     44.4      -1.6      46.0
            7    480.60      22.8         H         16.3      4.1     43.1      -2.9      46.0
            8    713.70      16.8         H         19.8      4.9     41.5      -4.5      46.0
            9    751.00      16.3         H         20.3      5.0     41.5      -4.5      46.0
           10    793.00      15.3         H         20.7      5.2     41.2      -4.8      46.0
           11    793.50      16.1         H         20.7      5.2     42.0      -4.0      46.0
           12    867.80      16.3         H         21.3      5.5     43.1      -2.9      46.0
           13    921.40      13.1         V         21.9      5.6     40.7      -5.3      46.0
           14    928.90      10.3         V         22.0      5.6     37.9      -8.1      46.0




Test Report No.: TK-FR10020                                                                   Page 18 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                         www.kes.co.kr



Test Results

 EUT         Wireless HD Kit                     Measurement Detail
 Model       GWAV8141K                           Frequency Range              1-40GHz
 Channel     36                                  Detector function            Average/Peak

        The requirements are:

             Complies

           Frequency                Measured Data            Margin
                                                                                      Remark
             (MHz)                    (dBuV/m)                (dB)
               -                          -                     -                Average/Peak

        Test Data – Configuration Draft n 40MHz ANT. A-1

                                                        Correction             Limits/
                Reading                                                                     Result
 Frequency                           Height                                   Detector
                  A/P        Pol.                         Factor                               A/P
                                                                                A/P

   [MHz]       [dBuV/m]               [m]     Antenna     Amp.Gain    Cable   [dBuV/m]    [dBuV/m]


            No emissions were detected at a level greater than 20dB below limit.


           Test Data – Configuration Draft n 40MHz ANT. A-2

                                                        Correction             Limits/
                Reading                                                                     Result
 Frequency                           Height                                   Detector
                  A/P        Pol.                         Factor                               A/P
                                                                                A/P

   [MHz]       [dBuV/m]               [m]     Antenna     Amp.Gain    Cable   [dBuV/m]    [dBuV/m]


            No emissions were detected at a level greater than 20dB below limit.


        Restricted band edge test data


                                                        Correction
 Frequency     Reading               Height                                    Limits      Result
                                                         Factor
                            Pol.
                                                            Amp.
   [MHz]      [dBuV/m]                [m]     Antenna                 Cable   [dBuV/m]    [dBuV/m]
                                                            Gain

            No emissions were detected at a level greater than 20dB below limit.


Test Report No.: TK-FR10020                                                                   Page 19 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                         www.kes.co.kr


Test Results

 EUT         Wireless HD Kitr                    Measurement Detail
 Model       GWAV8141K                           Frequency Range              1-40GHz
 Channel     48                                  Detector function            Average/Peak

        The requirements are:

             Complies

           Frequency                Measured Data            Margin
                                                                                      Remark
             (MHz)                    (dBuV/m)                (dB)
               -                          -                     -                Average/Peak

        Test Data – Configuration Draft n 40MHz ANT. A-1

                                                        Correction             Limits/
                Reading                                                                     Result
 Frequency                           Height                                   Detector
                  A/P        Pol.                         Factor                               A/P
                                                                                A/P

   [MHz]       [dBuV/m]               [m]     Antenna     Amp.Gain    Cable   [dBuV/m]    [dBuV/m]


            No emissions were detected at a level greater than 20dB below limit.


           Test Data – Configuration Draft n 40MHz ANT. A-2

                                                        Correction             Limits/
                Reading                                                                     Result
 Frequency                           Height                                   Detector
                  A/P        Pol.                         Factor                               A/P
                                                                                A/P

   [MHz]       [dBuV/m]               [m]     Antenna     Amp.Gain    Cable   [dBuV/m]    [dBuV/m]


            No emissions were detected at a level greater than 20dB below limit.


        Restricted band edge test data


                                                        Correction
 Frequency     Reading               Height                                    Limits      Result
                            Pol.                         Factor

                                                            Amp.
   [MHz]      [dBuV/m]                [m]     Antenna                 Cable   [dBuV/m]    [dBuV/m]
                                                            Gain

            No emissions were detected at a level greater than 20dB below limit.




Test Report No.: TK-FR10020                                                                   Page 20 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr



2.1.6 Frequency Stability Measurement 15.407(g)



      Procedures

      1. The transmitter output (antenna port) was connected to the spectrum analyser.
      2. EUT have transmitted absence of modulation signal and fixed channelize.
      3. Set the spectrum analyzer span to view the entire absence of modulation emissions
         bandwidth.
      4. Set RBW = 10 kHz, VBW = 10 kHz with peak detector and max hold settings.
      5. fc is declaring of channel frequency. Then the frequency error formula is (fc-f)/fc ×
         106 ppm and the limit is less than ±20ppm (Draft n specification).
      6. The test extreme voltage is to change the primary supply voltage from 85 to 115
         percent of the nominal value
      7. Extreme temperature rule is -30°C~50°C. 8. Measuring multiple antennas, the
         connector is required to link with spectrum analyser through a combiner



    The spectrum analyzer is set to:
    RBW /VBW= 10kHz
    Span = Entire absence of modulation emissions bandwidth
    Sweep = auto



      Test Setup Layout



              EUT                                          Spectrum Analyzer




Test Report No.: TK-FR10020                                                                   Page 21 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                     www.kes.co.kr


Measurement Data:


Temperature vs. Frequency Stability


                Temperature                              Measurement Frequency (MHz)

                       (℃)                                                   5190

                        -10                                              5189.995595

                         0                                               5189.991505

                        10                                               5189979043

                        20                                               5189.971572

                        30                                               5189.943853

                        40                                               5189.937430

                        50                                               5189.929765

                  +15% voltage                                           5189.930931

                  -15% voltage                                           5189.930465

              Max. Deviation (MHz)                                         0.070235

             Max. Deviation (ppm)                                           12.056



        Limit : 20ppm




Test Report No.: TK-FR10020                                                                   Page 22 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr




2.1.8 AC Conducted Emissions 15.207

        Test Location
        Shielded Room

        Frequency Range of Measurement
        150 kHz to 30 MHz

        Instrument Settings
        IF Band Width: 9 kHz

        Test Procedures

        The EUT was placed on a non-metallic table 0.8m above the metallic, grounded floor
        and 0.4m from the reference ground plane wall. The distance to other metallic surfaces
        was at least 0.8m.
        Amplitude measurements were performed with a quasi-peak detector and an average
        detector.

        Limit

        - 15.207(a)
             Frequency                      Conducted Limit (dBuV)
               (MHz)               Quasi-peak                    Average
           0.15 ~ 0.5           66 to 56*                56 to 46*
            0.5 ~ 5                 56                      46
             5 ~ 30                 60                      50
        * Decreases with the logarithm of the frequency.

        Test Results
        The requirements are:

            Complies
              Frequency           Measured Data             Margin
                                                                                       Remark
                (MHz)               (dBuV/m)                 (dB)
                0.156                 51.51                 14.16                    Quasi-peak




Test Report No.: TK-FR10020                                                                   Page 23 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr



Test Data


 측정주파수                 보정 계수                            준첨두값                              평균값
                                      극성
    [MHz]       LISN        케이블              제한값       측정값         결과값        제한값       측정값         결과값

   0.156        0.08        0.13       H      66       51.30       51.51       56       37.03       37.24

   0.180        0.10        0.18       N      64       49.77       50.05       54       25.03       25.31

   0.249        0.08        0.13       N      62       43.99       44.20       52       29.43       29.64

   0.276        0.06        0.11       H      61       42.21       42.38       51       33.52       33.69

   0.309        0.07        0.10       N      60       39.54       39.71       50       21.34       21.51

   0.498        0.05        0.10       H      56       36.31       36.46       46       28.27       28.42

   0.528        0.05        0.10       N      56       33.36       33.51       46       22.51       22.66

   1.116        0.06        0.07       H      56       32.11       32.24       46       22.51       22.64

   1.194        0.06        0.06       N      56       27.37       27.49       46       16.77       16.89

   1.410        0.06        0.04       H      56       32.19       32.29       46       23.03       23.13

   1.764        0.06        0.01       H      56       30.82       30.89       46       22.38       22.45

   4.179        0.11        0.04       N      56       27.16       27.31       46       18.56       18.71

   7.707        0.21        0.10       N      60       33.45       33.76       50       26.26       26.57

   8.445        0.25        0.03       H      60       32.49       32.77       50       25.05       25.33

   14.151       0.50        0.10       N      60       30.36       30.96       50       25.57       26.17

   16.230       0.55        0.10       H      60       27.84       28.49       50       24.34       24.99

   20.730       0.91        0.11       N      60       27.84       28.87       50       19.65       20.68

   20.820       0.88        0.11       H      60       25.82       26.81       50       17.94       18.93




Test Report No.: TK-FR10020                                                                   Page 24 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                    www.kes.co.kr



                                                  [HOT]




                                               [NEUTRAL]




Test Report No.: TK-FR10020                                                                   Page 25 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                                                                     www.kes.co.kr



APPENDIX A – Test Equipment Used For Tests




 No      Description          Manufacturer           Model No.           Serial No.       Due Cal.
  1       Test Receiver       Rohde & Schwarz          ESHS 10           862970/018       2011.05.06
  2       Test Receiver       Rohde & Schwarz          ESVS 10           826008/014       2011.05.06
  3    Spectrum Analyzer      Hewlett Packard           8566B            2311A02394       2011.05.06
  4    Spectrum Analyzer Rohde & Schwarz                FSP13               100130        2011.05.06
  5   Modulation Analyzer     Hewlett Packard           8901B            3438A05094       2011.05.06
  6      Audio analyzer       Hewlett Packard           8903B            3011A12915       2011.05.06
  7        Preamplifer        Hewlett Packard           8447F            2805A02570       2011.05.06
  8        Preamplifer         A.H. Systems           PAM-0118                164         2011.05.06
  9     Signal Generator      Hewlett Packard           8673D            2708A00448       2011.05.06
 10       Power Meter         Hewlett Packard            437B             312U24787       2011.05.06
 11       Power Sensor        Hewlett Packard           8482B            3318A06943       2011.05.06
 12      Loop Antenna         Rohde & Schwarz HFH2-Z2.335.4711.52 826532/006              2011.02.06
 13      Dipole Antenna       Rohde & Schwarz            VHAP                 574         2010.07.07
 14      Dipole Antenna       Rohde & Schwarz            VHAP                 575         2010.07.17
 15      Dipole Antenna       Rohde & Schwarz            UHAP                 545         2010.07.17
 16      Dipole Antenna       Rohde & Schwarz            UHAP                 546         2010.07.07
 17    Biconical Antenna        Eaton Corp.            94455-1               0977         2010.07.03
 18    Biconical Antenna          EMCO                  3104C             9111-2468       2010.07.03
 19 Log Periodic Antenna          EMCO                   3146                2051         2010.06.05
 20 Log Periodic Antenna          EMCO                   3146             8901-2320       2010.07.03
 21      Horn Antenna          A.H. Systems            SAS-571                414         2011.03.16
 22 Waveform Generator Hewlett Packard                  33120A           US34001190       2011.05.06
 23    Digital Oscilloscope      Tektronix            TDS 340A             B012287        2011.05.06

 24       Dummy Load          Bird Electronics           8251               11511         2011.05.06




Test Report No.: TK-FR10020                                                                   Page 26 of 26
Model No: GWAV8141K
Applicant: ATEN Technology, Inc., dba IOGEAR
       This Report shall not be reproduced except in full without the written approval of THRU-KES


                                               www.kes.co.kr


             Test Setup Photos and Configuration
Conducted Voltage Emissions


                                    www.kes.co.kr



Radiated Electric Field Emissions



Document Created: 2010-06-02 12:07:08
Document Modified: 2010-06-02 12:07:08

© 2025 FCC.report