Test Report

FCC ID: QK8UT-4000

Test Report

Download: PDF
FCCID_4033647

                                                               SGS-CSTC Standards Technical Services Co., Ltd.
                                                               Shenzhen Branch

No. 1 Workshop, M-10, Middle section, Science & Technology Park,
Shenzhen, Guangdong, China 518057
Telephone:            +86 (0) 755 2601 2053                                                                                       Report No.: SZEM180900825001
Fax:                  +86 (0) 755 2671 0594
                                                                                                                                  Page:        1 of 25
Email:                ee.shenzhen@sgs.com




                                                                    TEST REPORT
Application No.:                                         SZEM1809008250CR
Applicant:                                               Dakota Alert
Address of Applicant:                                    PO Box 130. 32556 477th Ave, Elk Point, 57025 South Dakota, United States
Manufacturer:                                            DF Electronics Technology Limited
Address of Manufacturer:                                 Flat G, 6/F., Block 6, Whampoa Garden Site 11, Hong Kong
Equipment Under Test (EUT):
EUT Name:                                                UT-4000 Universal Transmitter
Model No.:                                               UT-4000
Trade mark:                                              Dakota Alert
FCC ID:                                                  QK8UT-4000
Standard(s) :                                            47 CFR Part 15, Subpart C 15.231
Date of Receipt:                                         2018-09-11
Date of Test:                                            2018-09-12 to 2018-09-21
Date of Issue:                                           2018-09-26
Test Result:                                             Pass*
* In the configuration tested, the EUT complied with the standards specified above.




                   Keny Xu
             EMC Laboratory Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new
system complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International
Electrical Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International
Electrical Approvals in writing.
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       2 of 25


                                                                                            Revision Record
                 Version                    Chapter                                           Date                                        Modifier                               Remark

                 01                                                                   2018-09-26                                                                                 Original




       Authorized for issue by:




                                                                     Leo Li /Project Engineer




                                                                     Eric Fu /Reviewer




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       3 of 25


2          Test Summary
            Radio Spectrum Technical Requirement
                              Item                               Standard                                    Method                                     Requirement                               Result
                                                         47 CFR Part 15,                                                                      47 CFR Part 15, Subpart
            Antenna Requirement                                                                                  N/A                                                                                Pass
                                                         Subpart C 15.231                                                                           C 15.203
             N/A: Not applicable

            Radio Spectrum Matter Part
                              Item                               Standard                                    Method                                     Requirement                               Result
                                                         47 CFR Part 15,                         ANSI C63.10 (2013)                           47 CFR Part 15, Subpart
                 20dB Bandwidth                                                                                                                                                                     Pass
                                                         Subpart C 15.231                           Section 6.9                                    C 15.231(c)
                      Dwell Time                         47 CFR Part 15,                         ANSI C63.10 (2013)                           47 CFR Part 15, Subpart
                                                                                                                                                                                                    Pass
                      (15.231(a))                        Subpart C 15.231                          Section 7.8.4                                   C 15.231(a)
                                                         47 CFR Part 15,                                                                     47 CFR Part 15C Section
                      Duty Cycle                                                                   ANSI C63.10:2013                                                                                 Pass
                                                         Subpart C 15.231                                                                           15.35 (c)
             Field Strength of the
                                                         47 CFR Part 15,                         ANSI C63.10 (2013)                           47 CFR Part 15, Subpart
             Fundamental Signal                                                                                                                                                                     Pass
                                                         Subpart C 15.231                           Section 6.5                                    C 15.231(b)
                  (15.231(b))
                                                         47 CFR Part 15,                         ANSI C63.10 (2013)                           47 CFR Part 15, Subpart
              Radiated Emissions                                                                                                                                                                    Pass
                                                         Subpart C 15.231                        Section 6.4&6.5&6.6                               C 15.231(b)
             N/A: Not applicable




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                            SGS—CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                  Report No.: SZENM1e0:00s25001
                                                  Page        4 of 25

3         Contents
                                                                              Page
1.        covenprce
2.        Test summany.
s         contents
a    eenenaL inFonmation
 41—     bemuscrEUT
 42.     Descartonor Supzort Uins
 43      Mexsureent Uicermiay
 aa     TesLoownon
 45— TestFroum
 48.     Devamonrromstawowes
 47     AmvommumesrronStaicaro Conmions
s Eoupment List.
6         rabio spectnum teornicaL recumement
     s1        AemwRecursuert
          €.1.1 TestRequrement
          612 Corclisn
7         rabio spectnum matren Test nesuuts
     71  aneemomom                                                                10
    Z11 EUT.Operatin                                                              to
    712. TestSoup Dagam                                                           to
    718 Measuement Procedire and Data                                             to
 72. ueutwe (s231@)                                                               12
    721| EUT. Operaiion                                                           12
    722 TestSouip Dagam                                                           12
    729 Measurement Procedire and Data                                            12
 7e tumGrae                                                                       14
 74. feo Smevomer me Fuvoweir. Sow(15231@)                                        is
    74.1— EUT. Operatin                                                           ir
    742. TestSoup Diagram                                                         iz
    748 Measurement Procedire and Data                                            ir
 78— MaowieoBussous                                                               19
    751 EUT. Operatin                                                             2o
    752 TestSouip Dagam                                                           2o
    759| Measurement Procedireand Data                                            2o
a photocnaphs
 an      Tesrseur                                                                 2s
 a2 EUT CoustruononcDetts @UT Proros)                                             2s


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       5 of 25


4          General Information
4.1 Details of E.U.T.
           Power supply:                                    3V DC(3V x 1 "CR2" Battery)
           Test voltage:                                    DC 3V
           Operation Frequency                              433.92MHz
           Modulation Type                                  GFSK
           Number of Channels                               1
           Antenna Type                                     Integral antenna
           Antenna Gain                                     0dBi


4.2 Description of Support Units
           The EUT has been tested as an independent unit.


4.3 Measurement Uncertainty

                No.                                                      Item                                                              Measurement Uncertainty
                  1                                          Radio Frequency                                                                             ± 7.25 x 10-8
                  2                                                 Duty cycle                                                                               ± 0.37%
                  3                                       Occupied Bandwidth                                                                                    ± 3%
                  4                                       RF conducted power                                                                                ± 0.75dB
                  5                                          RF power density                                                                               ± 2.84dB
                  6                             Conducted Spurious emissions                                                                                ± 0.75dB
                                                                                                                                                ± 4.5dB (below 1GHz)
                  7                                        RF Radiated power
                                                                                                                                                ± 4.8dB (above 1GHz)
                                                                                                                                                ± 4.5dB (Below 1GHz)
                  8                            Radiated Spurious emission test
                                                                                                                                               ± 4.8dB (Above 1GHz)
                  9                                          Temperature test                                                                                   ± 1°C
                 10                                              Humidity test                                                                                  ± 3%
                 11                                             Supply voltages                                                                               ± 1.5%
                 12                                                      Time                                                                                   ± 3%




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       6 of 25

4.4 Test Location
            All tests were performed at:
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
            No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
            518057.
            Tel: +86 755 2601 2053                                    Fax: +86 755 2671 0594
            No tests were sub-contracted.

4.5 Test Facility
            The test facility is recognized, certified, or accredited by the following organizations:
            • CNAS (No. CNAS L2929)
            CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
            Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
            Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
            Laboratories) for the competence in the field of testing.
            • A2LA (Certificate No. 3816.01)
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
            American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
            • VCCI
            The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
            Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
            Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
            been registered in accordance with the Regulations for Voluntary Control Measures with Registration
            No.: G-20026, R-14188, C-12383 and T-11153 respectively.
            • FCC –Designation Number: CN1178
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
            as an accredited testing laboratory.
            Designation Number: CN1178. Test Firm Registration Number: 406779.
            • Innovation, Science and Economic Development Canada
            SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
            by ISED as an accredited testing laboratory.
            CAB identifier: CN0006.
            IC#: 4620C.
4.6 Deviation from Standards
            None
4.7 Abnormalities from Standard Conditions
            None




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       7 of 25


5          Equipment List
20dB Bandwidth
            Equipment                                   Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
      DC Power Supply                                         ZhaoXin                           RXN-305D                      SEM011-02                    2018-09-25                   2019-09-24
     Spectrum Analyzer                              Rohde & Schwarz                                   FSP                     SEM004-06                    2017-09-27                   2018-09-26
                                                                                                JS1120-2
 Measurement Software                                    JS Tonscend                                                                  N/A                          N/A                         N/A
                                                                                               BT/WIFI V2.
          Coaxial Cable                                          SGS                                   N/A                    SEM031-02                    2018-07-12                   2019-07-11
             Attenuator                          Weinschel Associates                                WA41                     SEM021-09                            N/A                         N/A
       Signal Generator                                    KEYSIGHT                                N5173B                     SEM006-05                    2017-09-27                   2018-09-26
           Power Meter                              Rohde & Schwarz                                  NRVS                     SEM014-02                    2018-09-25                   2019-09-24


Dwell Time (15.231(a)) and Duty Cycle
            Equipment                                   Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
      DC Power Supply                                         ZhaoXin                           RXN-305D                      SEM011-02                    2018-09-25                   2019-09-24
     Spectrum Analyzer                              Rohde & Schwarz                                   FSP                     SEM004-06                    2017-09-27                   2018-09-26
                                                                                                JS1120-2
 Measurement Software                                    JS Tonscend                                                                  N/A                          N/A                         N/A
                                                                                               BT/WIFI V2.
          Coaxial Cable                                          SGS                                   N/A                    SEM031-02                    2018-07-12                   2019-07-11
             Attenuator                          Weinschel Associates                                WA41                     SEM021-09                            N/A                         N/A
       Signal Generator                                    KEYSIGHT                                N5173B                     SEM006-05                    2017-09-27                   2018-09-26
           Power Meter                              Rohde & Schwarz                                  NRVS                     SEM014-02                    2018-09-25                   2019-09-24


Field Strength of the Fundamental Signal (15.231(b))
            Equipment                                   Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
     3m Semi-Anechoic
                                                      ETS-LINDGREN                                     N/A                    SEM001-01                    2017-08-05                   2020-08-04
         Chamber
                                                                                             e3 V8.2014-6-
 Measurement Software                                          AUDIX                                                                  N/A                          N/A                         N/A
                                                                                                  27
          Coaxial Cable                                          SGS                                   N/A                    SEM025-01                    2018-07-12                   2019-07-11
      EMI Test Receiver                           Agilent Technologies                             N9038A                     SEM004-05                    2018-09-25                   2019-09-24
     BiConiLog Antenna
                                                      ETS-LINDGREN                                  3142C                     SEM003-01                    2017-06-27                   2020-06-26
       (26-3000MHz)
          Pre-amplifier
                                                  Agilent Technologies                              8447D                     SEM005-01                    2018-04-02                   2019-04-01
         (0.1-1300MHz)

Radiated Emissions (Below 1GHz)
     Test Equipment                                Manufacturer                                Model No.                     Inventory No.                    Cal. Date                 Cal. Due date
 3m Semi-Anechoic
                                                ETS-LINDGREN                                         N/A                      SEM001-01                    2017-08-05                    2020-08-04
      Chamber
 MXE EMI Receiver
                                            Agilent Technologies                                 N9038A                       SEM004-05                    2017-09-27                    2018-09-26
   (20Hz-8.4GHz)
 BiConiLog Antenna
                                                ETS-LINDGREN                                      3142C                       SEM003-01                    2017-06-27                    2020-06-26
   (26-3000MHz)
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       8 of 25
      Pre-amplifier
                                            Agilent Technologies                                  8447D                       SEM005-01                    2018-04-02                    2019-04-01
     (0.1-1300MHz)
      Measurement                                                                                                                     N/A
                                                         AUDIX                          e3 V8.2014-6-27                                                            N/A                          N/A
        Software
      Coaxial Cable                                        SGS                                       N/A                      SEM025-01                     2018-07-12                   2019-07-11


Radiated Emissions (Above 1GHz)
     Test Equipment                                Manufacturer                                Model No.                     Inventory No.                    Cal. Date                 Cal. Due date
 3m Semi-Anechoic
                           AUDIX               N/A                                                                            SEM001-02                    2018-03-13                    2021-03-12
       Chamber
EXA Signal Analyzer Agilent Technologies
                                             N9010A                                                                           SEM004-09                    2018-04-13                    2019-04-12
   (10Hz-26.5GHz)            Inc
BiConiLog Antenna
                        ETS-Lindgren         3142C                                                                            SEM003-01                    2017-06-27                    2020-06-26
    (26-3000MHz)
     Horn Antenna
                      Rohde & Schwarz        HF907                                                                            SEM003-07                    2018-04-13                    2021-04-12
  (800MHz-18GHz)
       Amplifier
                             HP              8447D                                                                            SEM005-02                    2017-09-27                    2018-09-26
    (0.1-1300MHz)
Low Noise Amplifier                       BDLNA-0118-
                    Black Diamond Series                                                                                      SEM005-05                    2017-09-27                    2018-09-26
  (100MHz-18GHz)                             352810
       Band filter           N/A               N/A                                                                                    N/A                          N/A                          N/A
     Measurement                                                                                                                      N/A
                           AUDIX         e3 V8.2014-6-27                                                                                                           N/A                          N/A
       Software
      Coaxial Cable                                        SGS                                       N/A                      SEM026-01                     2018-07-12                   2019-07-11


General used equipment
             Equipment                                  Manufacturer                             Model No                   Inventory No                      Cal Date                Cal Due Date
                                                         Shanghai
  Humidity/ Temperature
                                                       Meteorological                               ZJ1-2B                    SEM002-03                    2017-09-29                   2018-09-28
        Indicator
                                                      Industry Factory
                                                         Shanghai
  Humidity/ Temperature
                                                       Meteorological                               ZJ1-2B                    SEM002-04                    2017-09-29                   2018-09-28
        Indicator
                                                      Industry Factory
  Humidity/ Temperature
                                                                Mingle                                 N/A                    SEM002-08                    2017-09-29                   2018-09-28
        Indicator
                                                        Changchun
              Barometer                                Meteorological                                DYM3                     SEM002-01                    2018-04-08                   2019-04-07
                                                      Industry Factory




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       9 of 25



6          Radio Spectrum Technical Requirement
6.1 Antenna Requirement
6.1.1 Test Requirement:
      47 CFR Part 15, Subpart C 15.203

6.1.2 Conclusion
      Standard Requirement:
      An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
      responsible party shall be used with the device. The use of a antenna that uses a unique coupling to
      the intentional radiator, the manufacturer may design the unit permanently attached antenna or of an
      so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
      electrical connector is prohibited.

            EUT Antenna:




            The antenna is integrated on the main PCB and no consideration of replacement. The best case gain
            of the antenna is 0dBi.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       10 of 25



7          Radio Spectrum Matter Test Results
7.1 20dB Bandwidth
           Test Requirement                                 47 CFR Part 15, Subpart C 15.231(c)
           Test Method:                                     ANSI C63.10 (2013) Section 6.9
           Limit:

                      Frequency range(MHz)                                                                                                   Limit
                                       70-900                                                           No wider than 0.25% of the center frequency
                                   Above 900                                                             No wider than 0.5% of the center frequency



7.1.1 E.U.T. Operation
      Operating Environment:
      Temperature:      23.8 °C      Humidity: 54.2 % RH           Atmospheric Pressure: 1010                                                                                                       mbar
      Test mode         a:TX mode_Keep the EUT in transmitting with modulation mode.
7.1.2 Test Setup Diagram




7.1.3 Measurement Procedure and Data
            20dB bandwidth (MHz)                                                              Limit (MHz)                                                                 Results
                           0.0098                                                                  1.8048                                                                   Pass




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       11 of 25
                                                                                     * RBW 300 Hz                    Delta 1 [T1 ]
                                                                                     * VBW 1 kHz                                 0.17 dB
          Ref       10 dBm                           * Att       10 dB                 SWT 340 ms                         9.807692306 kHz

            10                                                                                                       Marker 1 [T1 ]
                                                                                                                               -23.46               dBm
            0                                                            2                                              433.914903846               MHz      A
                                                                                                                     Marker 2 [T1 ]
1 PK                                                                                                                            -3.02               dBm
VIEW
            -10                                                                                                         433.918221154               MHz



            -20                                          1                                              1
                         D1 -23.02 dBm

            -30



            -40

                                                                                                                                                           3DB
            -50



            -60



            -70



            -80


            -90

           Center        433.92 MHz                                          3 kHz/                                                 Span      30 kHz




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       12 of 25


7.2 Dwell Time (15.231(a))
           Test Requirement                                 47 CFR Part 15, Subpart C 15.231(a)
           Test Method:                                     ANSI C63.10 (2013) Section 7.8.4
           Limit:

                                        Device type                                                                               Limit
                                                                                                                The switch automatically deactivate the
                       Manually operated transmitter                                                         transmitter within not more than 5 seconds of
                                                                                                                             being released
                                                                                                               Cease transmission within 5 seconds after
                     Automatically actived transmitter
                                                                                                                                activation
Periodic transmissions to determine system integrity of                                                       The total transmission time does not exceed
  transmitters used in security or safety applications                                                                     2 seconds per hour



7.2.1 E.U.T. Operation
      Operating Environment:
      Temperature:      23.8 °C      Humidity: 54.2 % RH           Atmospheric Pressure: 1010                                                                                                       mbar
      Test mode         a:TX mode_Keep the EUT in transmitting with modulation mode.
7.2.2 Test Setup Diagram




7.2.3 Measurement Procedure and Data
                        Test item                                                                  Limit                                                             Results
     Transmitting time: 1.927885s                                                                   ≤5S                                                                Pass



This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       13 of 25

                                                                                         RBW 3 MHz
                                                                                       * VBW 3 MHz
           Ref       10 dBm                           * Att        10 dB                 SWT 10 s

            10


                                                                                                                                                                 A
            0
                                                                                                                                                                SGL
1 PK *
VIEW
            -10



            -20



            -30



            -40

                                                                                                                                                                3DB
            -50



            -60



            -70



            -80


            -90

           Center 433.92 MHz                                                      1 s/




                                                                                        RBW 3 MHz                     Delta 1 [T1 ]
                                                                                     * VBW 3 MHz                                 -0.03 dB
          Ref       10 dBm                            * Att       10 dB                 SWT 3 s                              28.846154 ms

            10                                                                                                        Marker 1 [T1 ]
                                                                                                                                -13.16                dBm
            0                                                                                                               519.230769                ms      A
                                                                                                                      Delta 2 [T1 ]                          SGL
1 PK *                                                                                                                           -0.07                dB
VIEW
            -10                    11                                                                                       2 1.927885                s



            -20



            -30



            -40

                                                                                                                                                             3DB
            -50



            -60



            -70



            -80


            -90

          Center 433.92 MHz                                                   300 ms/




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       14 of 25


7.3 Duty Cycle
           Test Requirement:                                47 CFR Part 15C Section 15.35 (c)
           Test Method:                                     ANSI C63.10:2013
           Test Setup:




           Limit:                                           N/A
           Test Mode:                                       Transmitting mode
           Instruments Used:                                Refer to section 5 for details
           Test Results:                                    Pass




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       15 of 25




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       16 of 25


7.4 Field Strength of the Fundamental Signal (15.231(b))
           Test Requirement      47 CFR Part 15, Subpart C 15.231(b)
           Test Method:          ANSI C63.10 (2013) Section 6.5
           Measurement Distance: 3m
           Limit:

              Fundamental                                             Field strength of                                                 Field strength of spurious
            frequency(MHz)                                      fundamental(microvolts/meter)                                          emissions(microvolts/meter)
                 40.66-40.70                                                               2250                                                                  225
                      70-130                                                               1250                                                                  125
                     130-174                                                       1250 to 3750                                                           125 to 375
                     174-260                                                               3750                                                                  375
                     260-470                                                      3750 to 12500                                                          375 to 1250
          Above 470                            12500                            1250
Remark: the emission limit is based on measurement instrumentation employing an average detector
at a distance of 3 meters. The frequencies above 1000MHz are based on average limits. However, the
peak field strength of any emission shall not exceed the maximum permitted average limits specified
above by more than 20 dB under any condition of modulation.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       17 of 25


7.4.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C        Humidity: 60.8 % RH           Atmospheric Pressure: 1010                                                                                                       mbar
      Test mode         a:TX mode_Keep the EUT in transmitting with modulation mode.
7.4.2 Test Setup Diagram




7.4.3 Measurement Procedure and Data
      a. For below 1GHz, the EUT was placed on the top of a rotating table 0.8 meters above the ground at
      a 3 or 10 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position
      of the highest radiation.
      b. For above 1GHz, the EUT was placed on the top of a rotating table 1.5 meters above the ground at
      a 3 meter fully-anechoic chamber. The table was rotated 360 degrees to determine the position of the
      highest radiation.
      c. The EUT was set 3 or 10 meters away from the interference-receiving antenna, which was
      mounted on the top of a variable-height antenna tower.
      d. The antenna height is varied from one meter to four meters above the ground to determine the
      maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set
      to make the measurement.
      e. For each suspected emission, the EUT was arranged to its worst case and then the antenna was
      tuned to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was
      tuned to heights 1 meter) and the rotatable table was turned from 0 degrees to 360 degrees to find
      the maximum reading.
      f. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum
      Hold Mode.
      g. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing
      could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that
      did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method
      as specified and then reported in a data sheet.
      h. The radiation measurements are performed in X, Y, Z axis positioning. And found the X axis
      positioning which it is worse case, only the test worst case mode is recorded in the report.
      Remark: Level= Read Level+ Cable Loss+ Antenna Factor- Preamp Factor




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       18 of 25


7.4.3.1 Field Strength Of The Fundamental Signal
Average value:
                                            Average value=Peak value + PDCF
 Calculate Formula:                         PDCF=20 log(Duty cycle)= 20 log(27.88/100)=-11.09
                                            Duty cycle= T on time / T period
                                            Ton time =27.88ms
          Test data:
                                            T period =100ms


Peak value:
                        Cable                 Antenna                  Preamp                 Read                                                                    Over
Frequenc                                                                                                          Level                  Limit Line
                        Loss                   Factor                   Factor                Level                                                                                       Polarization
 y (MHz)                                                                                                        (dBuV/m)                 (dBuV/m)                Limit (dB)
                         (dB)                  (dB/m)                    (dB)                (dBuV)
  433.92                 2.35                     23.2                    27.79                91.2                 88.96                  100.83                   -11.87                 Horizontal
  433.92                 2.35                     23.2                    27.79               90.55                 88.31                  100.83                   -12.52                    Vertical
Average Value:
Frequenc                                                                Average Level                             Limit Line
                                       PCDF                                                                                                          Over Limit (dB)                      Polarization
 y (MHz)                                                                  (dBuV/m)                                (dBuV/m)
  433.92                                                                        77.87                                 80.83                                    -2.96                       Horizontal
                                      -11.09
  433.92                                                                        77.22                                 80.83                                    -3.61                          Vertical




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       19 of 25


7.5 Radiated Emissions
           Test Requirement      47 CFR Part 15, Subpart C 15.231(b)
           Test Method:          ANSI C63.10 (2013) Section 6.4&6.5&6.6
           Measurement Distance: 3m
           Limit:

                                                                                Field                                                                Measurement
              Frequency(MHz)
                                                                      strength(microvolts/meter)                                                   distance(meters)
                   0.009-0.490                                                        2400/F(kHz)                                                                300
                   0.490-1.705                                                      24000/F(kHz)                                                                  30
                    1.705-30.0                                                                 30                                                                 30
                         30-88                                                                100                                                                  3
                        88-216                                                                150                                                                  3
                       216-960                                                                200                                                                  3
           Above 960                            500                                 3
Remark: The emission limits shown in the above table are based on measurements employing a
CISPR quasi-peak detector except for the frequency bands 9-90kHz, 110-490kHz and above 1000
MHz. Radiated emission limits in these three bands are based on measurements employing an
average detector, the peak field strength of any emission shall not exceed the maximum permitted
average limits specified above by more than 20 dB under any condition of modulation.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       20 of 25


7.5.1 E.U.T. Operation
      Operating Environment:
      Temperature:      23.6 °C      Humidity: 58.9 % RH           Atmospheric Pressure: 1010                                                                                                       mbar
      Test mode         a:TX mode_Keep the EUT in transmitting with modulation mode.
7.5.2 Test Setup Diagram




7.5.3 Measurement Procedure and Data
      For testing performed with the loop antenna, the center of the loop was positioned 1 m above the
      ground and positioned with its plane vertical at the specified distance from the EUT. During testing
      the loop was rotated about its vertical axis for maximum response at each azimuth and also
      investigated with the loop positioned in the horizontal plane. Only the worst position of vertical was
      shown in the report.




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       21 of 25

30MHz~1GHz
    Mode:a; Polarization:Horizontal




            Average Value:
Frequency                                                               Average Level                             Limit Line
                                         PCDF                                                                                                        Over Limit (dB)                      Polarization
  (MHz)                                                                   (dBuV/m)                                (dBuV/m)
    867.84                              -11.09                                  47.08                                 60.83                                   -13.75                       Horizontal




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       22 of 25


Mode:a; Polarization:Vertical




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       23 of 25


Above 1GHz
     Mode:a; Polarization:Horizontal




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       24 of 25


Mode:a; Polarization:Vertical




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.


                                                             SGS-CSTC Standards Technical Services Co., Ltd.
                                                             Shenzhen Branch
                                                                                                                                 Report No.: SZEM180900825001
                                                                                                                                 Page:       25 of 25


8         Photographs

8.1 Test Setup
            Refer to Setup Photos


8.2 EUT Constructional Details (EUT Photos)
            Refer to EUT external and internal photos




                                                                                   - End of the Report -




This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention
only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and
obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the
content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s)
tested and such sample(s) are retained for 30 days only.



Document Created: 2018-10-09 04:06:37
Document Modified: 2018-10-09 04:06:37

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC