Test Report DXX original

FCC ID: QISVOG-LX9M

Test Report

Download: PDF
FCCID_4283962

                                  SGS-CSTC Standards Technical Services Co., Ltd.
                                  Shenzhen Branch




                                                                     Report No.: SZEM190401296702
                                                                     Page:        1 of 33


                                    TEST REPORT
Application No.:                SZEM1904012967CR (HR/2019/30012)
Applicant:                      Huawei Technologies Co., Ltd.
Address of Applicant:           Administration Building, Headquarters of Huawei Technologies Co., Ltd.,
                                Bantian, Longgang District Shenzhen, 518129, P.R.C
Manufacturer:                   Huawei Technologies Co., Ltd.
Address of Manufacturer:        Administration Building, Headquarters of Huawei Technologies Co., Ltd.,
                                Bantian, Longgang District Shenzhen, 518129, P.R.C
Equipment Under Test (EUT):
EUT Name:                       Smart Phone
Model No.:                      VOG-L04m
Trade mark:                     HUAWEI
FCC ID:                         QISVOG-L04M
Standard(s) :                   47 CFR Part 15, Subpart C 15.225
Date of Receipt:                2019-04-19
Date of Test:                   2019-04-20 to 2019-04-30
Date of Issue:                  2019-04-30
Test Result:                    Pass*
* In the configuration tested, the EUT complied with the standards specified above.




             Keny Xu
       EMC Laboratory Manager


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                          Report No.: SZEM190401296702
                                                          Page:       2 of 33



                                        Revision Record
     Version       Chapter              Date                 Modifier       Remark

     01                              2019-04-30                             Original




Authorized for issue by:




                             Damon Su /Project Engineer




                             Eric Fu /Reviewer


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                           Report No.: SZEM190401296702
                                                           Page:       3 of 33



2   Test Summary
    Radio Spectrum Technical Requirement
            Item             Standard             Method               Requirement          Result
                          47 CFR Part 15,                         47 CFR Part 15, Subpart
    Antenna Requirement                             N/A                                     Pass
                          Subpart C 15.225                              C 15.203


    Radio Spectrum Matter Part
            Item             Standard             Method               Requirement          Result
    Conducted Emissions
                        47 CFR Part 15,      ANSI C63.10 (2013)   47 CFR Part 15, Subpart
     at AC Power Line                                                                       Pass
                        Subpart C 15.225        Section 6.2             C 15.207
      (150kHz-30MHz)
                          47 CFR Part 15,    ANSI C63.10 (2013)   47 CFR Part 15, Subpart
      20dB Bandwidth                                                                        Pass
                          Subpart C 15.225      Section 6.9             C 15.215
                          47 CFR Part 15,    ANSI C63.10 (2013)   47 CFR Part 15, Subpart
       Emission Mask                                                                        Pass
                          Subpart C 15.225      Section 6.4        C 15.225(a)&(b)&(C )
                          47 CFR Part 15,    ANSI C63.10 (2013)   47 CFR Part 15, Subpart
    Frequency tolerance                                                                     Pass
                          Subpart C 15.225      Section 6.8            C 15.225(e)
         Radiated
                          47 CFR Part 15,    ANSI C63.10 (2013)   47 CFR Part 15, Subpart
      Emissions(9kHz-                                                                       Pass
                          Subpart C 15.225    Section 6.4&6.5      C 15.225(d) & 15.209
          30MHz)
         Radiated
                          47 CFR Part 15,    ANSI C63.10 (2013)   47 CFR Part 15, Subpart
     Emissions(30MHz-                                                                       Pass
                          Subpart C 15.225    Section 6.4&6.5      C 15.225(d) & 15.209
          1GHz)


                                                       SGS—CSTC Standards Technical Services Co., Ltd.
                                                       Shenzhen Branch

                                                                                                                          Report No.: SZEM190401296702
                                                                                                                          Page:                    4 of 33



3            Contents
                                                                                                                                                                                         Page
1           COVER PAGE ... ... ... ... cnccnenerereererererereereverereerereeererereeererere e reeeee e reenere en ner en nenne en nenne en nennnevvenennnvvvenenennnn 1

2           TEST SUMMARY ... ... ... .. cnne000 00606090999 errerevere e ereeerererereererere e reeere e reeeereereener en neene en nenneeveenennnevvenennnnvvenene 3

3           CONTENTS ....... .. cce n00 00000090999 errererere e reererereerereeererere e reeee e e reeee e e en n re en en nn en nenne en nennn en nennn en nennnvevenenennnn 4

4           GENERAL INFORMATION ... ...... .. .nn 0000000090099 e rereeererereeererereeererereeereeeeeaereererereenee en en nen en en nennnvvvenennnne 6
      4.1           DETAILS OF E.T. cce




                                                                                                                                                                                            NN\ ooo
      4.2           DEsCRIPTION oF SupPort Units
      4.3           MEASUREMENT UNCERTAINTY .
      4.4           TEST LOCATION.... cce
      4.5           TEST FACILITY.secmmemmmeree
      4.6           DEVIATION FROM STANDARDS..                                                                                                .
      4.7           ABNORMALITIES FROM STANDARD CONDITIONS ........ .ce nee en en en en en n en en nene n en en en en n en en nenenennenen en en 7
5           EQUIPMENT LIST ... 0000000 eeeen e eneneerenneeneenenenneenenennnenenenneenennnnen en nnennn en en en nnennn en nnennnnnnnnnnrene 8

6           RADIO SPECTRUM TECHNICAL REQUIREMENT ......0.0. 00000000 eeermeereeermeereeenmeereeenmnmeereeneerennnnnees 10
      6.1           ANTENNA REQUIREMENT ........ ce mm e m em en en eere n en en en n en en n n eneere n n eneereneneneeee en eneene n en eneenenenennnnen n 10
            6.1.1        Test Requirement:                                                                                                                                               .... 10
            6.1.2         Conclusion ..                                                                                                                                                  .... 10
7           RADIO SPECTRUM MATTER TEST RESULTS....                                                                                                                                         41
      7.1           ConbpucteD Emissions at AC Powenr Line (150KHz—30MHz).                                                                                                               «211
            7.1.1        EU.T. ODBTAHION..........cccmemerememeemeemerermememnenenememenenne                                                                                             ... 12
            7.1.2        Test Setup DIagram ...                                                                                                                                          ... 12
            7.1.3     Measurement Procedure and Data...                                                                                                                                  ... 12
      7.2           200B BANDWIDTH.....                                                                                                                                                  «.. 15
            7.2.1        E.U.T. Operation.                                                                                                                                               ... 15
            7.2.2        Test Setup Diagram ....l.c.ccclll                                                                                                                               ... 15
            7.2.3     Measurement Procedure and Data...                                                                                                                                  ... 15
      7.3           EMISSION MASK .....                                                                                                                                                  «217
            7.3.1        E.U.T. Operation.                                                                                                                                                .. 18
            7.3.2 Test Setup Diagram ....c.ccclll                                                                                                                                        .... 18
            7.3.3 Measurement Procedure and Data                                                                                                                                             18
      7.4       FREQUENCY TOLERANCE                                                                                                                                                         .21
          7.4.1   E.U.T. Operation.                                                                                                                                                          .21
            7.4.2         Test Setup Diagram.                                                                                                                                                .21
            7.4.3     Measurement Procedure and Data                                                                                                                                         .21
      7.5           RADIATED EMiSSIONS(OKHz—30MHz)                                                                                                                                          .23
            7.5.1        E.U.T. Operation.                                                                                                                                                   .24
            7.5.2         Test Setup Diagram.                                                                                                                                                .24
            7.5.3     Measurement Procedure and Data                                                                                                                                         .24
      7.6           RADIATED EmissiONS(3OMHz—1 GHz).......                                                                                                                               ....28
            7.6.1        E.U.T. Operation......                                                                                                                                          ... 29
            7.6.2         Test Setup Diagram.                                                                                                                                             ... 29
                                         Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                         overieaf, available on request or accessible at hitp:/Iwww. sgs.com/an/Terms—and—Conditions.aspx and, for electronic format documents,
                                         subject fo Terms and Conditions for Electronic Documents at hitp:/iww.ags. comfen/Terms—and—Conditions/Terms—e—Document aspx.
                                         Attention is drawn to the limitation of liabilit, indermnification and Jurisdiction Issues defined therein. Any holder of this document is
                                         advised that information contained hereon reflects the Company‘s tindings at the time of its intervention only and within the !imits of
                                         Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                                         transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                         exeept in full. without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
                                         appearance of this doctment is unlawlul and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the
                                         results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                                         Aftention: To check the authenticity of testing /inspection report & certificate, please contact us at tolephone: (86—755) 8307 1443
                                         or email: CN.Doccheck@sas.com
                                          No.t Workshop 10idSecton, Science &Technology Pak, Shonzhen, Chine §18057....   t (B6—756)26012058 f (86—755)26710504     wnncogegroup.comon
    StenwhenBant             Clatoaloy    *B —20l— ARBRENM—108—STB                                    #BS: steosr         t (86—755) 26012053 1 (86—755) 26710504   sgs.china@sgs.com
                                                                                                                                             Member of the SGS Group (SGS SA)


                                              SGS—CSTC Standards Technical Services Co., Ltd.
                                              Shenzhen Branch

                                                                                                              Report No.: SZEM190401296702
                                                                                                              Page:                     5 of 33

          7.6.3      Measurement Procedure and Data...
8     PHOTOGRAPHS.
    8.1           Test SetuP..
    8.2           EUT ConstRuctionaL DetaiLs (EUT PHotos)...




                             Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                             overieaf, available on request or accessible at nn?iIwarw.sgs.comienfTerm              onditions aspy and. for electronic format documents.
                                                                                    ncnm ls l it       wwsus comfenTerms—and—Gonditions/Terms—e—Document.aspx.
                             Attention is drawn to the limitation of liability,               n and          ion issues defined therein. Any holder of this document is
                             sivieed bat Mornaten contgined nerean totentshe Companys flndlngs at the time oits intervention only and within the !imits of
                             Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                             fransaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                             exeant in full. without prior written appraval of the Company. Any unauthorized alteration, forgery or faleification of the content or
                             appearance of this document is unlawful and offendars may be prosecuted to the fullest extent the law. Unless otherwise stated the
                             results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                             Xitention: To check the abthentiolty of testing napection report & cortilivate, prease contact us at fdlephone: (66—755) 8307 1443,
                              or email: CN.Doccheck@sas.com
                                 No.t Wortshop,,Mél Secton, Science & Technology Pak,Shenthen, China 518057   t (%6—758)26012068 1 (86—756)26710504     wincogegroup.comon
                                 *B —20l— ARBRENM—108—ST B                                  #BS: steosr       t (86—755) 26012053 1 (86—755) 26710504   sgs.china@sgs.com
                             I
                                                                                                                                 Member of the SGS Group (SGS SA)


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                Report No.: SZEM190401296702
                                                                Page:       6 of 33


4   General Information
4.1 Details of E.U.T.
    Power supply:            DC 3.82V from internal rechargeable battery or from AC/DC adapter
                             Model: HW-100400U00, HW-100400E00, HW-100400B00, HW-100400A00
    Cable:                   USB cable: 100cm shielded
                             Earphone cable: 115cm unshielded
    Antenna Type:            Loop Antenna
    Modulation Type:         ASK
    Operation Frequency:     13.56MHz


4.2 Description of Support Units
    The EUT has been tested as an independent unit.


4.3 Measurement Uncertainty

      No.                           Item                           Measurement Uncertainty
       1                      Radio Frequency                            ± 7.25 x 10-8
       2                        Duty cycle                                 ± 0.37%
       3                    Occupied Bandwidth                              ± 3%
       4                    RF conducted power                             ± 0.75dB
       5                      RF power density                             ± 2.84dB
       6               Conducted Spurious emissions                        ± 0.75dB
                                                                     ± 4.5dB (below 1GHz)
       7                     RF Radiated power
                                                                     ± 4.8dB (above 1GHz)
                                                                     ± 4.5dB (Below 1GHz)
       8               Radiated Spurious emission test
                                                                     ± 4.8dB (Above 1GHz)
       9                      Temperature test                              ± 1°C
       10                       Humidity test                               ± 3%
       11                     Supply voltages                              ± 1.5%
       12                           Time                                    ± 3%


                            SGS-CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                               Report No.: SZEM190401296702
                                                               Page:       7 of 33


4.4 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
    No. 1 Workshop, M-10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
    518057.
    Tel: +86 755 2601 2053        Fax: +86 755 2671 0594
    No tests were sub-contracted.
4.5 Test Facility
    The test facility is recognized, certified, or accredited by the following organizations:
    • CNAS (No. CNAS L2929)
    CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
    Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
    Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
    Laboratories) for the competence in the field of testing.
    • A2LA (Certificate No. 3816.01)
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
    American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
    • VCCI
    The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
    Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
    Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
    been registered in accordance with the Regulations for Voluntary Control Measures with Registration
    No.: G-20026, R-14188, C-12383 and T-11153 respectively.
    • FCC –Designation Number: CN1178
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    as an accredited testing laboratory.
    Designation Number: CN1178. Test Firm Registration Number: 406779.
    • Innovation, Science and Economic Development Canada
    SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
    by ISED as an accredited testing laboratory.
    CAB identifier: CN0006.
    IC#: 4620C.
4.6 Deviation from Standards
    None
4.7 Abnormalities from Standard Conditions
    None


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                Report No.: SZEM190401296702
                                                                Page:       8 of 33



5      Equipment List
Conducted Emissions at AC Power Line (150kHz-30MHz)
        Equipment           Manufacturer        Model No      Inventory No    Cal Date    Cal Due Date
      Shielding Room      ZhongYu Electron       GB-88        SEM001-06      2017-05-10    2020-05-09
Measurement Software           AUDIX          e3 V5.4.1221d       N/A           N/A           N/A
       Coaxial Cable            SGS               N/A         SEM024-01      2018-07-12    2019-07-11
           LISN           Rohde & Schwarz       ENV216        SEM007-01      2018-09-25    2019-09-24
           LISN            ETS-LINDGREN          3816/2       SEM007-02      2019-04-01    2020-03-31
     EMI Test Receiver    Rohde & Schwarz         ESCI        SEM004-02      2019-04-01    2020-03-31


RF conducted test
        Equipment           Manufacturer        Model No      Inventory No    Cal Date    Cal Due Date
     DC Power Supply          ZhaoXin          PS-3005D       SEM011-05      2018-09-25    2019-09-24
    Spectrum Analyzer
                          Rohde & Schwarz        FSU43        SEM004-08      2019-04-12    2020-04-11
      (20Hz-43GHz)
Signal Generator (9kHz-
                             KEYSIGHT           N5173B        SEM006-05      2018-09-27    2019-09-26
        40GHz)
                                               JS1120-2
Measurement Software        JS Tonscend                           N/A           N/A           N/A
                                              BT/WIFI V2.6
       Coaxial Cable            SGS               N/A         SEM031-01      2018-07-12    2019-07-11
     Attenuator        Weinschel Associates      WA41         SEM021-09         N/A           N/A
   Programmable              Votsch
Temperature & Humidity   Industrietechnik       VT 4002       SEM002-15      2019-04-01    2020-03-31
      Chamber                GmbH


Radiated Emissions(9kHz-30MHz)
        Equipment           Manufacturer        Model No      Inventory No    Cal Date    Cal Due Date
    10m Semi-Anechoic
                               SAEMC           FSAC1018       SEM001-03      2018-03-31    2021-03-30
        Chamber
                                              e3 V8.2014-6-
Measurement Software           AUDIX                              N/A           N/A           N/A
                                                   27
       Coaxial Cable            SGS               N/A         SEM029-01      2018-07-12    2019-07-11
     EMI Test Receiver
                          Rohde & Schwarz         ESR         SEM004-03      2019-04-01    2020-03-31
       (9kHz-7GHz)
   Trilog-Broadband
                            Schwarzbeck        VULB9168       SEM003-18      2016-06-29    2019-06-28
Antenna(30MHz-1GHz)
                          Sonoma Instrument
       Pre-amplifier                              310N        SEM005-04      2019-04-12    2020-04-11
                                Co
    Active Loop Antenna     ETS-Lindgren          6502        SEM003-08      2017-08-22    2020-08-21


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                               Report No.: SZEM190401296702
                                                               Page:       9 of 33



Radiated Emissions(30MHz-1GHz)
     Equipment             Manufacturer       Model No       Inventory No    Cal Date    Cal Due Date
  10m Semi-Anechoic
                              SAEMC           FSAC1018       SEM001-03      2018-03-31    2021-03-30
      Chamber
                                             e3 V8.2014-6-
Measurement Software          AUDIX                              N/A           N/A           N/A
                                                  27
    Coaxial Cable              SGS               N/A         SEM029-01      2018-07-12    2019-07-11
  EMI Test Receiver
                         Rohde & Schwarz         ESR         SEM004-03      2019-04-01    2020-03-31
    (9kHz-7GHz)
   Trilog-Broadband
                           Schwarzbeck        VULB9168       SEM003-18      2016-06-29    2019-06-28
Antenna(30MHz-1GHz)
                         Sonoma Instrument
     Pre-amplifier                               310N        SEM005-04      2019-04-12    2020-04-11
                               Co
 Active Loop Antenna       ETS-Lindgren          6502        SEM003-08      2017-08-22    2020-08-21


General used equipment
     Equipment             Manufacturer       Model No       Inventory No    Cal Date    Cal Due Date
                             Shanghai
Humidity/ Temperature
                           Meteorological       ZJ1-2B       SEM002-03      2018-09-27    2019-09-26
      Indicator
                          Industry Factory
                             Shanghai
Humidity/ Temperature
                           Meteorological       ZJ1-2B       SEM002-04      2018-09-27    2019-09-26
      Indicator
                          Industry Factory
Humidity/ Temperature
                              Mingle             N/A         SEM002-08      2018-09-27    2019-09-26
      Indicator
                            Changchun
      Barometer            Meteorological       DYM3         SEM002-01      2019-04-04    2020-04-03
                          Industry Factory


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                   Report No.: SZEM190401296702
                                                                   Page:       10 of 33




6     Radio Spectrum Technical Requirement
6.1 Antenna Requirement
6.1.1 Test Requirement:
      47 CFR Part 15, Subpart C 15.203

6.1.2 Conclusion
      Standard Requirement:
      An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
      responsible party shall be used with the device. The use of a permanently attached antenna or of an
      antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to
      comply with the provisions of this section. The manufacturer may design the unit so that a broken
      antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is
      prohibited.

      EUT Antenna:
      The antenna is integrated on the main PCB and no consideration of replacement.
      Antenna location: Refer to internal photos.


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                    Report No.: SZEM190401296702
                                                                    Page:       11 of 33




7      Radio Spectrum Matter Test Results
7.1 Conducted Emissions at AC Power Line (150kHz-30MHz)
       Test Requirement     47 CFR Part 15, Subpart C 15.207
       Test Method:         ANSI C63.10 (2013) Section 6.2
       Limit:


                                         Limit (dBuV)
    Frequency range (MHz)
                               Quasi-peak               Average
          0.15-0.5              66 to 56*               56 to 46*
            0.5-5                   56                     46
            5-30                    60                     50
                            * Decreases with the logarithm of the frequency.


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                   Report No.: SZEM190401296702
                                                                   Page:       12 of 33




7.1.1 E.U.T. Operation
      Operating Environment:
      Temperature:      21.8 °C      Humidity: 58.2 % RH           Atmospheric Pressure: 1015         mbar
      Test mode         g:TX mode_Keep the EUT in transmitting with modulation mode.
7.1.2 Test Setup Diagram




7.1.3 Measurement Procedure and Data
      1) The mains terminal disturbance voltage test was conducted in a shielded room.
      2) The EUT was connected to AC power source through a LISN 1 (Line Impedance Stabilization
      Network) which provides a 50ohm/50µH + 5ohm linear impedance. The power cables of all other
      units of the EUT were connected to a second LISN 2, which was bonded to the ground reference
      plane in the same way as the LISN 1 for the unit being measured. A multiple socket outlet strip was
      used to connect multiple power cables to a single LISN provided the rating of the LISN was not
      exceeded.
      3) The tabletop EUT was placed upon a non-metallic table 0.8m above the ground reference plane.
      And for floor-standing arrangement, the EUT was placed on the horizontal ground reference plane,
      4) The test was performed with a vertical ground reference plane. The rear of the EUT shall be 0.4 m
      from the vertical ground reference plane. The vertical ground reference plane was bonded to the
      horizontal ground reference plane. The LISN 1 was placed 0.8 m from the boundary of the unit under
      test and bonded to a ground reference plane for LISNs mounted on top of the ground reference
      plane. This distance was between the closest points of the LISN 1 and the EUT. All other units of the
      EUT and associated equipment was at least 0.8 m from the LISN 2.
      5) In order to find the maximum emission, the relative positions of equipment and all of the interface
      cables must be changed according to ANSI C63.10 on conducted measurement.
      Remark: LISN=Read Level+ Cable Loss+ LISN Factor


                         SGS-CSTC Standards Technical Services Co., Ltd.
                         Shenzhen Branch
                                               Report No.: SZEM190401296702
                                               Page:       13 of 33



Mode:g; Line:Live Line


                            SGS-CSTC Standards Technical Services Co., Ltd.
                            Shenzhen Branch
                                                  Report No.: SZEM190401296702
                                                  Page:       14 of 33



Mode:g; Line:Neutral Line


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                                Report No.: SZEM190401296702
                                                                Page:       15 of 33



7.2 20dB Bandwidth
     Test Requirement        47 CFR Part 15, Subpart C 15.215
     Test Method:            ANSI C63.10 (2013) Section 6.9
     Measurement Distance:   10m
     Limit:                  N/A

7.2.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C        Humidity: 51 % RH             Atmospheric Pressure: 1015   mbar
      Test mode         g:TX mode_Keep the EUT in transmitting with modulation mode.
7.2.2 Test Setup Diagram




7.2.3 Measurement Procedure and Data


                                         SGS-CSTC Standards Technical Services Co., Ltd.
                                         Shenzhen Branch
                                                                                         Report No.: SZEM190401296702
                                                                                         Page:       16 of 33

                                                       * RBW   1 kHz   Marker 1 [T1 ]
                                                       * VBW   3 kHz                -9.14 dBm
       Ref   10 dBm             * Att   15 dB           SWT    20 ms         13.560625000 MHz

       10                                                              ndB [T1]   20.00 dB
                                                                       BW   2.652243590 kHz
       0                                                               Temp 1 [T1 ndB]            A
                                                                                 -29.04   dBm
1 PK                                               1                       13.559278846   MHz
VIEW
       -10                                                             Temp 2 [T1 ndB]
                                                                                 -29.13   dBm
                                                                           13.561931090   MHz
       -20

                         T1                                             T2
       -30



       -40

                                                                                                 3DB
       -50



       -60



       -70



       -80


       -90

       Center   13.560625 MHz                   500 Hz/                           Span   5 kHz


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                                 Report No.: SZEM190401296702
                                                                 Page:       17 of 33



7.3 Emission Mask
     Test Requirement      47 CFR Part 15, Subpart C 15.225(a)&(b)&(C )
     Test Method:          ANSI C63.10 (2013) Section 6.4
     Measurement Distance: 10m
     Limit:

(a) The field strength of any emissions within the band 13.553-13.567 MHz shall not exceed 15.848
microvolts/meter at 30 meters.
(b) Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of any emissions shall
    not exceed 334 microvolts/meter at 30 meters.
(c) Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz the field strength of any emissions shall not
    exceed 106 microvolts/meter at 30 meters.
(d) The field strength of any emissions appearing outside of the 13.110-14.010 MHz band shall not exceed
the general radiated emission limits in § 15.209.


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                   Report No.: SZEM190401296702
                                                                   Page:       18 of 33




7.3.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C        Humidity: 51 % RH             Atmospheric Pressure: 1015         mbar
      Test mode         g:TX mode_Keep the EUT in transmitting with modulation mode.
7.3.2 Test Setup Diagram




7.3.3 Measurement Procedure and Data
      For testing performed with the loop antenna, the center of the loop was positioned 1 m above the
      ground and positioned with its plane vertical at the specified distance from the EUT. During testing
      the loop was rotated about its vertical axis for maximum response at each azimuth and also
      investigated with the loop positioned in the horizontal plane. Only the worst position of vertical was
      shown in the report.


         SGS-CSTC Standards Technical Services Co., Ltd.
         Shenzhen Branch
                               Report No.: SZEM190401296702
                               Page:       19 of 33


Mode:g


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                            Report No.: SZEM190401296702
                                                            Page:       20 of 33

Mode:g

                         Antenna_
   Freq       Cable_              Preamp_ Read_Level Level Limit_Line Over_Limit
  (MHz)                   Factor
             Loss (dB)            Gain (dB) (dBuV)  (dBuV/m) (dBuV/m)   (dB)
                          (dB/m)
  13.561        0.57       10.47           32.51   67.46   45.99   103.08   -57.09

Below 30MHz
The test was performed at a 10m test site.
The level at 30m test distance is below:
The factor calculated by the following equation:


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                              Report No.: SZEM190401296702
                                                              Page:       21 of 33



7.4 Frequency tolerance
     Test Requirement        47 CFR Part 15, Subpart C 15.225(e)
     Test Method:            ANSI C63.10 (2013) Section 6.8
     Measurement Distance:   10m
     Limit:                  1.356kHz

7.4.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C        Humidity: 51 % RH             Atmospheric Pressure: 1015   mbar
      Test mode         g:TX mode_Keep the EUT in transmitting with modulation mode.
7.4.2 Test Setup Diagram




7.4.3 Measurement Procedure and Data


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                         Report No.: SZEM190401296702
                                                         Page:       22 of 33




Declared Frequency (MHz)            13.56MHz


                                     Measurement      Frequency
Temperature (°C)    Voltage(VDC)                                     Limit (%)   Result
                                    Frequency(MHz)   Tolerance (%)
       50                             13.560528        0.00389                   Pass
       40                             13.560208        0.00153                   Pass
       30                             13.560463        0.00341                   Pass
       20                             13.560476        0.00351                   Pass
                           3.82
       10                             13.560069        0.00051                   Pass
                                                                      ±0.01
        0                             13.560168        0.00124                   Pass
       -10                            13.560299        0.00221                   Pass
       -20                            13.560283        0.00209                   Pass
                           4.39       13.560251        0.00185                   Pass
       20
                           3.25       13.560768        0.00566                   Pass


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                           Report No.: SZEM190401296702
                                                           Page:       23 of 33



7.5 Radiated Emissions(9kHz-30MHz)
    Test Requirement      47 CFR Part 15, Subpart C 15.225(d) & 15.209
    Test Method:          ANSI C63.10 (2013) Section 6.4&6.5
    Measurement Distance: 10m
    Limit:


                         Field strength       Limit                 Measurement Distance
    Frequency(MHz)                                       Detector
                       (microvolts/meter)   (dBuV/m)                      (meters)
       0.009-0.490       2400/F(kHz)            -            -              300
       0.490-1.705        24000/F(kHz)           -           -               30
        1.705-30               30                -           -               30
         30-88                100              40.0        QP                3
         88-216               150              43.5        QP                3
        216-960               200              46.0        QP                3
        960-1000              500              54.0        QP                3
       Above 1000             500              54.0        AV                3


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                   Report No.: SZEM190401296702
                                                                   Page:       24 of 33




7.5.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C        Humidity: 51 % RH             Atmospheric Pressure: 1015         mbar
      Test mode         g:TX mode_Keep the EUT in transmitting with modulation mode.
7.5.2 Test Setup Diagram




7.5.3 Measurement Procedure and Data
      For testing performed with the loop antenna, the center of the loop was positioned 1 m above the
      ground and positioned with its plane vertical at the specified distance from the EUT. During testing
      the loop was rotated about its vertical axis for maximum response at each azimuth and also
      investigated with the loop positioned in the horizontal plane. Only the worst position of vertical was
      shown in the report.


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                            Report No.: SZEM190401296702
                                            Page:       25 of 33

Mode g 9kHz~150kHz:


                       SGS-CSTC Standards Technical Services Co., Ltd.
                       Shenzhen Branch
                                             Report No.: SZEM190401296702
                                             Page:       26 of 33

Mode:g, 150kHz-30MHz


                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch
                                                                  Report No.: SZEM190401296702
                                                                  Page:       27 of 33



             Level @      Limit @     Limit @                   Level @
Frequenc                                                                    Level @ 30m       Margin
               10m         300m        30m       Factor (dB)      300m
 y (MHz)                                                                      (dBuV/m)          (dB)
            (dBuV/m)     (dBuV/m) (dBuV/m)                      (dBuV/m)
   0.04       46.32        35.62      -             59.08         -12.76           -           -48.38
   0.07       43.78       30.29          -          59.08        -15.30            -           -45.59
   0.09       42.25       28.19          -          59.08        -16.83            -           -45.02
   0.49       49.74       13.82          -          59.08         -9.34            -           -23.16
   1.25       41.11          -         25.67        19.08           -           22.03          -3.65
   1.84       37.55          -         29.54        19.08           -           18.47          -11.08
   Remark:
    1) The field strength is calculated by adding the Antenna Factor, Cable Factor & Preamplifier. The basic
    equation with a sample calculation is as follows:
Final Test Level =Receiver Reading + Antenna Factor + Cable Factor – Preamplifier Factor


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                             Report No.: SZEM190401296702
                                                             Page:       28 of 33



7.6 Radiated Emissions(30MHz-1GHz)
    Test Requirement      47 CFR Part 15, Subpart C 15.225(d) & 15.209
    Test Method:          ANSI C63.10 (2013) Section 6.4&6.5
    Measurement Distance: 10m
    Limit:


                     Field strength    Limit                 Measurement
   Frequency                                     Remark
                   (microvolt/meter) (dBuV/m)                distance (m)
  30MHz-88MHz            100         40.0       Quasi-peak        3
 88MHz-216MHz            150         43.5       Quasi-peak        3
 216MHz-960MHz           200         46.0       Quasi-peak        3
  960MHz-1GHz            500         54.0       Quasi-peak        3


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                              Report No.: SZEM190401296702
                                                              Page:       29 of 33


7.6.1 E.U.T. Operation
      Operating Environment:
      Temperature:      25 °C        Humidity: 51 % RH             Atmospheric Pressure: 1015   mbar
      Test mode         g:TX mode_Keep the EUT in transmitting with modulation mode.
7.6.2 Test Setup Diagram


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                                   Report No.: SZEM190401296702
                                                                   Page:       30 of 33

7.6.3 Measurement Procedure and Data
      a. The EUT was placed on the top of a rotating table 0.8 meters above the ground for below 1GHz at
      a 3 meter semi-anechoic chamber. The table was rotated 360 degrees to determine the position of
      the highest radiation.
      b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on
      the top of a variable-height antenna tower.
      c. The antenna height is varied from one meter to four meters above the ground to determine the
      maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are set
      to make the measurement.
      d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was
      tuned to heights from 1 meter to 4 meters (for the test frequency of below 30MHz, the antenna was
      tuned to heights 1 meter) and the rotatable table was turned from 0 degrees to 360 degrees to find
      the maximum reading.
      e. The test-receiver system was set to Peak Detect Function and Specified Bandwidth with Maximum
      Hold Mode.
      f. If the emission level of the EUT in peak mode was 10dB lower than the limit specified, then testing
      could be stopped and the peak values of the EUT would be reported. Otherwise the emissions that
      did not have 10dB margin would be re-tested one by one using peak, quasi-peak or average method
      as specified and then reported in a data sheet.
      g. The radiation measurements are performed in X, Y, Z axis positioning. And found the X axis
      positioning which it is worse case, only the test worst case mode is recorded in the report.
      Remark: Level= Read Level+ Cable Loss+ Antenna Factor- Preamp Factor


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                              Report No.: SZEM190401296702
                                              Page:       31 of 33



Mode:g; Polarization:Horizontal


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                      Report No.: SZEM190401296702
                                                      Page:       32 of 33



Mode:g; Polarization:Vertical


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                    Report No.: SZEM190401296702
                                                                    Page:       33 of 33



8    Photographs

8.1 Test Setup
Refer to Setup Photos

8.2 EUT Constructional Details (EUT Photos)
Refer to EUT external and internal photos


                                            - End of the Report -



Document Created: 2019-05-01 10:24:38
Document Modified: 2019-05-01 10:24:38

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC