                        RF Test Report
                             Product Name: Smart Phone


                               Model Number: TRT—LX1


                       Report No: SYBH(Z—RF)014022017—2004
                                    FCC ID: QISTRT—LX1




                      Reliability Laboratory of Huawei Technologies Co.


       (Global Compliance and Testing Center of Huawei Technologies Co., Ltd)



Administration Building, Headquarters of Huawei Technologies Co., Ltd., Bantian, Longgang District,
                                       Shenzhen, 518129, P.R.C
                             Tel: +86 755 28780808           Fax: +86 755 89652518


          RF Test Report of TRT-LX1



                                                  Notice




1. The laboratory has Passed the accreditation by China National Accreditation Service for Conformity

Assessment (CNAS). The accreditation number is L0310.

2. The laboratory has Passed the accreditation by The American Association for Laboratory

Accreditation (A2LA). The accreditation number is 2174.01.

3. The laboratory has been listed by the US Federal Communications Commission to perform

electromagnetic emission measurements. The site recognition number is 97456.

4. The laboratory has been listed by Industry Canada to perform electromagnetic emission

measurements. The recognition numbers of test site are 6369A-1.

5. The test report is invalid if not marked with the signatures of the persons responsible for preparing

and approving the test report.

6. The test report is invalid if there is any evidence of erasure and/or falsification.

7. The test report is only valid for the test samples.

8. Content of the test report, in part or in full, cannot be used for publicity and/or promotional purposes

without prior written approval from the laboratory.

9. The laboratory (Reliability Lab of Huawei Technologies Co., Ltd) is also named as “Global

Compliance and Testing Center of Huawei Technologies Co., Ltd”, the both names have coexisted

since 2009.




Report No:                                 Huawei Proprietary and Confidential                 Page 2 of 19
SYBH(Z-RF)014022017-2004                Copyright © Huawei Technologies Co., Ltd.


           RF Test Report of TRT-LX1




Applicant:                     Huawei Technologies Co., Ltd.

Address:                       Administration Building, Headquarters of Huawei Technologies Co., Ltd.,

                               Bantian, Longgang District, Shenzhen, 518129, P.R.C




Date of Receipt Sample:        2017-02-24
Start Date of Test:            2017-02-25
End Date of Test:              2017-03-15




Test Result:                   Pass




Approved by Senior             2017-03-16              Roger Zhang
Engineer:                      Date                       Name                       Signature




Prepared by:                   2017-03-15               Mao Wenli

                               Date                        Name                        Signature




Report No:                                Huawei Proprietary and Confidential                    Page 3 of 19
SYBH(Z-RF)014022017-2004               Copyright © Huawei Technologies Co., Ltd.


            RF Test Report of TRT-LX1




                                                                           CONTENT

1   General Information ................................................................................................................................................ 5
    1.1        Applied Standard........................................................................................................................................ 5
    1.2        Test Location ............................................................................................................................................. 5
    1.3        Test Environment Condition ....................................................................................................................... 5
2   Test Summary ........................................................................................................................................................ 6
3   Description of the Equipment under Test (EUT) ..................................................................................................... 7
    3.1        General Description ................................................................................................................................... 7
    3.2        EUT Identity ............................................................................................................................................... 7
    3.3        Technical Description ................................................................................................................................. 8
4   General Test Conditions / Configurations ............................................................................................................... 9
    4.1        Test Modes ................................................................................................................................................ 9
    4.2        EUT Configurations .................................................................................................................................... 9
    4.3        Test Environments ................................................................................................................................... 10
    4.4        Antenna requirements .............................................................................................................................. 10
    4.5        Description of tests................................................................................................................................... 11
    4.6        Test Setups .............................................................................................................................................. 13
    4.7        Test Conditions ........................................................................................................................................ 16
5   Main Test Instruments .......................................................................................................................................... 18
6   Appendixes ........................................................................................................................................................... 19




Report No:                                                      Huawei Proprietary and Confidential                                                      Page 4 of 19
SYBH(Z-RF)014022017-2004                                     Copyright © Huawei Technologies Co., Ltd.


           RF Test Report of TRT-LX1




1     General Information


1.1    Applied Standard

Applied Rules:                     47 CFR FCC Part 2, Subpart J    2014
                                   47 CFR FCC Part 15, Subpart C 2014




Test Method:                       FCC KDB 558074 D01 DTS Meas Guidance v03r04
                                   ANSI C63.10-2013, American National Standard for Testing Unlicensed
                                   Wireless Devices.


1.2    Test Location

Test Location:                     Reliability Laboratory of Huawei Technologies Co., Ltd.
Address:                           Administration Building, Headquarters of Huawei Technologies Co., Ltd.,
                                   Bantian, Longgang District, Shenzhen, 518129, P.R.C


1.3    Test Environment Condition

Ambient Temperature:               19.5to 25 °C
Ambient Relative Humidity:         40 to 55 %
Atmospheric Pressure:              Not applicable




Report No:                                Huawei Proprietary and Confidential                       Page 5 of 19
SYBH(Z-RF)014022017-2004               Copyright © Huawei Technologies Co., Ltd.


s   <
HUAWEI       RF Test Report of TRT—LX1




2       Test Summary



Test Item                            FCC Part No.              Requirements                 Test Result     Verdict



DTS (6 dB) Bandwidth                 15.247(a)(2)              2500 kHz.                    Appendix A      Pass

                                                                                            Appendix B
Occupied Bandwidth                                                                                          Pass


                                     KDB 558074 (6.0)              22                              .
Duty Cycle                                                     No limit                     Appendix C      Pass


                                                               For directional gain: < 30

Maximum Conducted Average                                      dBm — (G[dBi] — 6 [dB]),            L
                                     15.247(0)(3)                              .            Appendix D      Pass
Output Power                                                   Average; Otherwise: <
                                                               30 dBm, Average.

                                                               For directional gain: < 8
    .                           .                              dBm/3 kHz — (G[dBi] — 6
Maximum Power Spectral Density                                                                     .
Level                                15.247(e)                 [dB]), Average.              Appendix E      Pass
 eve
                                                               Otherwise: < 8 dBm/3
                                                               kHz, Average.

Band Edges Compliance                                                           .                  .
                                                               <—30 dBm/100 kHz if          Appendix F      Pass
                                     15.247(d)                 total average power S
Unwanted Emissions into                                                m                           .
                                                               power limit.                 Appendix G      Pass
Non—Restricted Frequency Bands

Unwanted Emissions into              15.247(d)                 FCC Part 15.209 field
Restricted Frequency Bands           15.209                    strength limit;              Appendix H      Pass
(Radiated)                           (NOTE 1)

AC Power Line Conducted                                        FCC Part 15.207                     .
                                     15.207                                   20            Appendix I      Pass
Emissions                                                      conducted limit;


NOTE 1: According to KDB 558074, antenna—port conducted measurements are acceptable as an alternative to

radiated measurements for demonstrating compliance to the limits in the restricted frequency bands. If conducted
measurements are performed, then proper impedance matching must be ensured and an additional radiated test for
cabinet/case emissions will also be required.




Report No:                                     Huawei Proprietary and Confidential                        Page 6 of 19
SYBH(Z—RF)014022017—2004                    Copyright © Huawei Technologies Co., Ltd.


             RF Test Report of TRT-LX1




3     Description of the Equipment under Test (EUT)

3.1       General Description

TRT-LX1 is subscriber equipment in the GSM/UMTS/LTE system.The GSM frequency band includes GSM850 and
GSM900 and DCS1800 and PCS1900. The UMTS frequency band is band I/II/V/VIII. The LTE frequency band is band
I/III/V/VII/VIII/XX.The Mobile Phone implements such functions as RF signal receiving/transmitting, LTE/UMTS and
GSM/GPRS/EDGE protocol processing, voice, video MMS service, GPS and WIFI etc. Externally it provides micro SD
card interface, earphone port (to provide voice service) and USIM card interface. It also provides bluetooth module to
synchronize data between a PC and the phone, or to use the built-in modem of the phone to access the Internet with a
PC, or to exchange data with other bluetooth devices.
.
NOTE: Only 2.4G WIFI test data included in this report.
.
3.2       EUT Identity

NOTE:        Unless otherwise noted in the report, the functional boards installed in the units shall be selected from the
             below list, but not means all the functional boards listed below shall be installed in one unit.


3.2.1      Board


                                                            Board
Description                         Hardware Version                           Software Version
Main Board                          HL1TRTM                                    TRT-LX1C900B058


3.2.2      Sub-Assembly


Sub-Assembly
Sub-Assembly Name             Model                        Manufacturer                     Description
                                                           Huawei Technologies              Input Voltage: ~100-240V
Adapter                       HW-050200E01
                                                           Co., Ltd.                        Output Voltage: 5V/2A
                                                           Huawei Technologies              Input Voltage: ~100-240V
Adapter                       HW-050200B01
                                                           Co., Ltd.                        Output Voltage: 5V/2A
                                                           Huawei Technologies              I Input Voltage: ~100-240V
Adapter                       HW-050200A01
                                                           Co., Ltd.                        Output Voltage: 5V/2A
                                                           Huawei Technologies              Rated capacity: 3900mAh
Battery                       HB406689ECW
                                                           Co., Ltd.                        Nominal Voltage: +3.82V




Report No:                                       Huawei Proprietary and Confidential                            Page 7 of 19
SYBH(Z-RF)014022017-2004                      Copyright © Huawei Technologies Co., Ltd.


            RF Test Report of TRT-LX1




3.3     Technical Description


Characteristics         Description
IEEE 802.11 WLAN           802.11b (20 MHz channel bandwidth),         802.11g (20 MHz channel bandwidth)
Mode Supported             802.11n (20 MHz channel bandwidth),         802.11n (40 MHz channel bandwidth)
TX/RX Operating         2412-2462        fc = 2407 MHz + N * 5 MHz, where:
Range                    MHz band        -      fc = “Operating Frequency” in MHz,
                                         -      N = “Channel Number” with the range from 1 to 11 for the 20 MHz
                                                channel bandwidth, or 3 to 9 for the 40 MHz channel bandwidth
Data Rate               802.11b          1 Mbps, 2 Mbps, 5.5 Mbps, 11 Mbps
                        802.11g          6 Mbps, 9 Mbps, 12 Mbps, 18 Mbps, 24 Mbps, 36 Mbps, 48 Mbps, 54
                                         Mbps
                        802.11n (SISO)   MCS 0 to MCS 7
Modulation Type         DBPSK/DQPSK/CCK (DSSS), BPSK/QPSK/16QAM/64QAM (OFDM).
Emission Designator     10M1G7D (for 802.11b mode),
                        16M5G7D (for 802.11g mod),
                        17M6G7D (for 802.11n20 mode),
                        35M6G7D (for 802.11n40 mode)
TX Power Control           Supported,    Not Supported
Standby Mode               Supported,    Not Supported
Equipment Type             Stand-alone equipment,        Plug-in radio device,     Combined equipment
Antenna                 Description      Isotropic Antenna
                        Type                 External,       Integrated
                        Ports                Ant 1,       Ant 2,     Ant 3
                        Smart System         SISO (for 802.11b/g/n),
                                             Diversity (for 802.11b/g) :         Tx &      Rx
                        Gain             ANT1:-2 dBi (per antenna port, max.)
                        Remark           When the EUT is put into service, the practical maximum antenna gain
                                         should NOT exceed the value as described above.
Power Supply            Type                 AC/DC Adapter                       PoE:               Other:




Report No:                                  Huawei Proprietary and Confidential                         Page 8 of 19
SYBH(Z-RF)014022017-2004                 Copyright © Huawei Technologies Co., Ltd.


             RF Test Report of TRT-LX1




4     General Test Conditions / Configurations

4.1       Test Modes

NOTE:        Worst cases for each IEEE 802.11 mode are selected to perform tests.


Test Mode           Test Modes Description
11B                 IEEE 802.11b with data rate of 1 Mbps using SISO mode.
11G                 IEEE 802.11g with data rate of 6 Mbps using SISO mode.
11N20               IEEE 802.11n with data date of MCS0 and bandwidth of 20 MHz using SISO mode.
11N40               IEEE 802.11n with data date of MCS0 and bandwidth of 40 MHz using SISO mode.


4.2       EUT Configurations

4.2.1       General Configurations


Configuration                Description
Test Antenna Ports           Until otherwise specified,
                             -      All TX tests are performed at all TX antenna ports of the EUT, and
                             -      All RX tests are performed at all RX antenna ports of the EUT.
Multiple RF Sources          Other than the tested RF source of the EUT, other RF source(s) are disabled or shutdown
                             during measurements.


4.2.2       Customized Configurations


Test Mode        RF Ch.            TX Freq. [MHz]          Ch. BW [MHz]        Power Conf., per Port     Duty cycle [%]
    11B             L            Ch No. 1 / 2412 MHz             20                      16                   98
    11B             M            Ch No. 6 / 2437 MHz             20                      16                   98
    11B             H         Ch No. 11 / 2462 MHz               20                      16                   98
    11G             L            Ch No. 1 / 2412 MHz             20                      14                   87
    11G             M            Ch No. 6 / 2437 MHz             20                      14                   87
    11G             H         Ch No. 11 / 2462 MHz               20                      14                   87
    11N20           L            Ch No. 1 / 2412 MHz             20                      12                   86
    11N20           M            Ch No. 6/ 2437 MHz              20                      12                   86
    11N20           H         Ch No. 11 / 2462 MHz               20                      12                   86
    11N40           L            Ch No. 3 / 2422 MHz             40                      12                   76
    11N40           M            Ch No. 6 / 2437 MHz             40                      12                   76
    11N40           H            Ch No. 9 / 2452 MHz             40                      12                   76




Report No:                                      Huawei Proprietary and Confidential                      Page 9 of 19
SYBH(Z-RF)014022017-2004                     Copyright © Huawei Technologies Co., Ltd.


          RF Test Report of TRT-LX1




4.3     Test Environments

NOTE:     The values used in the test report may be stringent than the declared.


Environment Parameter                                    Selected Values During Tests
                                   Temperature                      Voltage             Relative Humidity
NTNV                                 Ambient                        3.8VDC                  Ambient


4.4     Antenna requirements

Excerpt from §15.203 of the FCC Rules/Regulations:
“An intentional radiator antenna shall be designed to ensure that no antenna other than that furnished by
the responsible party can be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section.”


The antennas of the TRT-LX1 are permanently attached.
There are no provisions for connection to an external antenna.


Conclusion:
The EUT FCC ID: QISTRT-LX1 unit complies with the requirement of §15.203.
Ch. Frequency (MHz)


                                          Ch.                Frequency (MHz)
                                           01                       2412


                                            .                          .
                                            .                          .


                                           06                       2437
                                            .                          .
                                            .                          .
                                           11                       2462



                                        Frequency/ Channel Operations




Report No:                                   Huawei Proprietary and Confidential                Page 10 of 19
SYBH(Z-RF)014022017-2004                  Copyright © Huawei Technologies Co., Ltd.


           RF Test Report of TRT-LX1




4.5     Description of tests

4.5.1 Bandwidth measurement
(a) Connect EUT test port to spectrum analyzer.
(b) Set the EUT to transmit maximum output power at 2.4GHz, then set the measured frequency
number and test the bandwidth with spectrum analyzer.

4.5.2 Duty Cycle measurement
(a) Connect EUT test port to spectrum analyzer.
(b) Set the EUT to transmit maximum output power at 2.4GHz, then set the measured frequency
number and test the Duty Cycle with spectrum analyzer.

4.5.3 Maximum Conducted Average Output Power
 (a) Connect EUT test port to spectrum analyzer.
(b) Set the EUT to transmit maximum output power at 2.4GHz.
(c) Then set the EUT to transmit at high, middle and low frequency and measure the conducted output
power separately.

4.5.4 Band edge spurious emission
(a) Connect EUT test port to spectrum analyzer
(b) Set the EUT to transmit maximum output power at 2.4GHz.
(c) Then set the EUT to transmit at high, low frequency and measure the conducted band edge
spurious separately.

4.5.5 Conducted RF spurious
(a) Connect EUT test port to spectrum analyzer
(b) Set the EUT to transmit maximum output power at 2.4GHz.
(c) Then set the EUT to transmit at high, middle and low frequency and measure the conducted
spurious separately.

4.5.6    Power spectral density
(a) Connect EUT test port to spectrum analyzer
(b) Set the EUT to transmit maximum output power at 2.4GHz.
(c) Then set the EUT to transmit at high, middle and low frequency and measure the conducted power spectral density.


4.5.7 Radiated spurious emission & spurious in restricted band
The test site semi-anechoic chamber has met the requirement of NSA tolerance 4dB according to the
standards: ANSI C63.10 (2013). The EUT was set-up on insulator 80cm above the Ground Plane. The
set-up and test methods were according to ANSI C63.10:2013.The Radiated Disturbance
measurements were made using a Rohde and Schwarz Test Receiver and control software.

A preliminary scan and a final scan of the emissions were made by using test script of software; the
emissions were measured using a Quasi-Peak Detector below 1GHz, Peak Detector and AV Detector



Report No:                                   Huawei Proprietary and Confidential                      Page 11 of 19
SYBH(Z-RF)014022017-2004                  Copyright © Huawei Technologies Co., Ltd.


         RF Test Report of TRT-LX1



above 1GHz. The maximal emission value was acquired by adjusting the antenna height, polarisation
and turntable azimuth in accordance with the software setup. Normally, the height range of antenna
was 1m to 4m,and the azimuth range of turntable was 0°to 360°. The receive antenna has two
polarizations V and H.

A portable or small unlicensed wireless device shall be placed on a non-metallic test fixture or other
nonmetallic support during testing. The supporting fixture shall permit orientation of the EUT in each of
three orthogonal (x, y, z) axis positions such that emissions from the EUT are maximized.

The EUT communicates with the BTS simulator through Air interface. The EUT operated on the
typical channel.

Measurement bandwidth: 30 MHz – 1000 MHz: 120 kHz
Measurement bandwidth: 1000 MHz – 10th Carrier Frequency:         1 MHz

4.5.8 Conducted Emission at Power Port
The Table-top EUT was placed upon a non-metallic table 0.8 m above the horizontal metal reference
ground plane. EUT was connected to LISN and LISN was connected to reference Ground Plane. EUT
was 80cm from LISN. The set-up and test methods were according to ANSI C63.10: 2013.

Conducted Disturbance at AC Port measurements were undertaken on the L and N Lines. The
emissions were measured using a Quasi-Peak Detector and Average Detector.

The EUT communicates with the BTS simulator through Air interface, the BTS simulator controls the
Wireless Modem to transmitter the maximum power which defined in specification of product. The
Wireless Modem operated on the typical channel.

Measurement bandwidth (RBW) for 150kHz to 30 MHz: 9 kHz;




Report No:                               Huawei Proprietary and Confidential                Page 12 of 19
SYBH(Z-RF)014022017-2004              Copyright © Huawei Technologies Co., Ltd.


           RF Test Report of TRT-LX1




4.6     Test Setups

4.6.1    Test Setup 1

The WLAN component’s antenna ports(s) of the EUT are connected to the measurement instrument per an appropriate
attenuator. The EUT is controlled by PC/software to emit the specified signals for the purpose of measurements.



                                       Jumper Cable for
                                    connecting to RF Cables
                                         (If applicable)              RF Cables
                                                                      for testing

      EUT                                                            Attenuator
                           WLAN                                                                 Measurement
                         Component                                                               Instrument


                                                       WLAN
                                                    component's
                                                   antenna port(s)


      Power         Control
      Supply         PC


4.6.2    Test Setup 2

The test site semi-anechoic chamber has met the requirement of NSA tolerance 4 dB according to the standards: ANSI
C63.4. The test distance is 3m.The setup is according to ANSI C63.4 and CAN/CSA-CEI/IEC CISPR 22.


The maximal emission value is acquired by adjusting the antenna height, polarisation and turntable azimuth. Normally,
the height range of antenna is 1 m to 4 m, the azimuth range of turntable is 0° to 360°, and the receive antenna has two
polarizations Vertical (V) and Horizontal (H).




Report No:                                      Huawei Proprietary and Confidential                      Page 13 of 19
SYBH(Z-RF)014022017-2004                     Copyright © Huawei Technologies Co., Ltd.


        RF Test Report of TRT-LX1




                                        Semi-Anechoic Chamber




                                                                                                MAX:4 m
                                                                                     Antenna

                                           EUT
                                                                                                            Preamplifier




                                                                           MIN:1 m
                                                     0.8 m


   AE                     Signal wire                                                          GRP
          Ferrite Clamp
                                                                                                             Receiver



                                                    (Below 1 GHz)




                                                    (Above 1 GHz)




Report No:                                      Huawei Proprietary and Confidential                       Page 14 of 19
SYBH(Z-RF)014022017-2004                     Copyright © Huawei Technologies Co., Ltd.


           RF Test Report of TRT-LX1




4.6.3    Test Setup 3

The mains cable of the EUT (maybe per AC/DC Adapter) must be connected to LISN. The LISN shall be placed 0.8 m
from the boundary of EUT and bonded to a ground reference plane for LISN mounted on top of the ground reference
plane. This distance is between the closest points of the LISN and the EUT. All other units of the EUT and associated
equipment shall be at least 0.8m from the LISN.


Ground connections, where required for safety purposes, shall be connected to the reference ground point of the LISN
and, where not otherwise provided or specified by the manufacturer, shall be of same length as the mains cable and
run parallel to the mains connection at a separation distance of not more than 0.1 m.




                                                        Shielding room



                                                                                                                             0.4m

                                                                                                                   EUT
                                                                                                                   Table
                                                                                   m
                                                                               0.8




                                                                                                                              0.8m
                                                                                              1m
                                                                                       le :
                                                                                 cab
                                                                          w   er                              1m
                                                                     Po                                 le:
             Receive                                                                            c  ab
                                                                                           i ng
                                          Power input      LISN                   ou
                                                                                       d
                                                                               Gr

                                                                                       D≤10cm                                  GRP




Report No:                                    Huawei Proprietary and Confidential                                          Page 15 of 19
SYBH(Z-RF)014022017-2004                   Copyright © Huawei Technologies Co., Ltd.


            RF Test Report of TRT-LX1




4.7     Test Conditions


Test Case           Test Conditions
                    Configuration          Description
DTS (6 dB)          Measurement Method     FCC KDB 558074 §8.1 Option 2.
Bandwidth           Test Environment       NTNV
                    Test Setup             Test Setup 1
                    EUT Configuration      11B_L, 11B_M, 11B_H
                                           11G_L, 11G_M, 11G_H
                                           11N20_L, 11 N20_M, 11 N20_H
                                           11N40_L, 11 N40_M, 11 N40_H
Occupied            Measurement Method     FCC KDB 558074 §8.2 Option 2.
Bandwidth           Test Environment       NTNV
                    Test Setup             Test Setup 1
                    EUT Configuration      11B_L, 11B_M, 11B_H
                                           11G_L, 11G_M, 11G_H
                                           11N20_L, 11 N20_M, 11 N20_H
                                           11N40_L, 11 N40_M, 11 N40_H
Maximum             Measurement Method     FCC KDB 558074 §9.2 .2. 4
Conducted           Test Environment       NTNV
Average Output      Test Setup             Test Setup 1
Power               EUT Configuration      11B_L, 11B_M, 11B_H
                                           11G_L, 11G_M, 11G_H
                                           11N20_L, 11 N20_M, 11 N20_H
                                           11N40_L, 11 N40_M, 11 N40_H
Maximum Power       Measurement Method     FCC KDB 558074§10.1 (peak PSD).
Spectral Density    Test Environment       NTNV
Level               Test Setup             Test Setup 1
                    EUT Configuration      11B_L, 11B_M, 11B_H
                                           11G_L, 11G_M, 11G_H
                                           11N20_L, 11 N20_M, 11 N20_H
                                           11N40_L, 11 N40_M, 11 N40_H
Band Edges          Measurement Method     FCC KDB 558074 §13.0.
Compliance          Test Environment       NTNV
                    Test Setup             Test Setup 1
                    EUT Configuration      11B_L, 11B_M, 11B_H
                                           11G_L, 11G_M, 11G_H
                                           11N20_L, 11 N20_M, 11 N20_H
                                           11N40_L, 11 N40_M, 11 N40_H
Unwanted            Measurement Method     FCC KDB 558074 §11.0
Emissions into      Test Environment       NTNV
Non-Restricted      Test Setup             Test Setup 1




Report No:                                  Huawei Proprietary and Confidential      Page 16 of 19
SYBH(Z-RF)014022017-2004                 Copyright © Huawei Technologies Co., Ltd.


             RF Test Report of TRT-LX1



Test Case            Test Conditions
                     Configuration          Description
Frequency Bands      EUT Configuration      11B_L, 11B_M, 11B_H
                                            11G_L, 11G_M, 11G_H
                                            11N20_L, 11 N20_M, 11 N20_H
                                            11N40_L, 11 N40_M, 11 N40_H
Unwanted             Measurement Method     ANSI C63.10; FCC KDB 558074 §12.1, Radiated
Emissions into       Test Environment       NTNV
Restricted           Test Setup             Test Setup 2
Frequency Bands      EUT Placement             Flatwise,      Upright,   Hung
(Radiated)           EUT Configuration      11B_L, 11B_M, 11B_H
                                            11G_L, 11G_M, 11G_H
                                            11N20_L, 11 N20_M, 11 N20_H
                                            11N40_L, 11 N40_M, 11 N40_H
AC Power Line        Measurement Method     Part 15.207
Conducted            Test Environment       NTNV
Emissions            Test Setup             Test Setup 3
                     EUT Configuration       (Worst Conf.).




Report No:                                   Huawei Proprietary and Confidential          Page 17 of 19
SYBH(Z-RF)014022017-2004                  Copyright © Huawei Technologies Co., Ltd.


s   <
HUAWEI                 RF Test Report of TRT—LX1




5         Main Test Instruments
                                                          Main Test Equipments
          Equipment Name                     Manufacturer           Model        Serial Number     Cal Date       Cal— Due
            Power supply                      KEITHLEY              2303            1342889       2016/10/13     2017/10/12

    Wireless Communication
      !                        unicall             Agilent         m4cioa        mv4gosisg2        2o18§6         201785
                       Test set
                   .        | Radi
        Universal Radio                             Rss           CMU2z200           123299       201814 201714
     Communication Tester

          Spectrum Analyzer                        Agilent         N9020A        MY52090652       2016/6/29       2017/6/29

                   .        | Radi
           Universal Radio                         Ras            Cmws00             126854       201812229 201712729
     Communication Tester
           Signal Analyzer                          R&S            FSQ31            200021         2016/8/5       2017/8/5

          Spectrum Analyzer                        Agilent         N9030A        MY49431698        2016/8/5       2017/8/5

    Temperature Chamber                            WEISS           WKL64       56246002940010     2016/12/21     2017/12/21

           Signal generator                        Agilent         E8257D        MY49281095        2016/8/5       2017/8/5

    Vector Signal Generator                         R&S           SMU200A            104162        2016/8/5       2017/8/5

             Test receiver                          R&S            ESU26             100387       2016/6/21       2017/6/21
             Test receiver                          R&S             ESCI             101163       2016/11/10     2017/1/10

          Spectrum analyzer                         R&S             FSU3            200474        2016/5/24       2017/5/24

          Spectrum analyzer                         R&S            FSU43             100144        2016/6/2       2017/6/2

                        LOOP
                                                    R&S           HFH2—Z2            100262       2015/4/30       2017/4/29
    Antennas(OkHz—30MHz)

                        LOOP
                         0o                         R&S           HFH2—Z2            100263       2015/4/30       2017/4/29
    Antennas(OkHz—30MHz)

 Trilog Broadband Antenna                                           VULB
     09                                    SCHWARZBECK                             9163—490       2015/4/30       2017/4/29
              (30M~3GHz)                                            9163
 Trilog Broadband Antenna                                           VULB
     09                                    SCHWARZBECK                             9163—520       2015/4/30       2017/4/29
             (30M~3GHz)                                             9163
           Double—Ridged
          Waveguide               Horn              R&S            HF907             100304       2015/4/30       2017/4/29
     Antenna (1G~18GHz)

          double ridged horn
            whie
    antenna (0.8G—18GHz)
                          ag                        Rss            HF9o7             100305       2015430         2017/4/29



Report No:                                               Huawei Proprietary and Confidential                  Page 18 of 19
SYBH(Z—RF)014022017—2004                              Copyright © Huawei Technologies Co., Ltd.


           RF Test Report of TRT-LX1



       Pyramidal Horn
                                ETS-Lindgren            Sep-60          5140299          2015/7/15       2017/7/14
Antenna(18GHz-26.5GHz)

    Artificial Main Network             R&S            ENV4200          100134            2016/6/2       2017/6/2

       Line Impedance
                                        R&S             ENV216          100382            2016/6/2       2017/6/2
    Stabilization Network
      Signal Generator                 Agilent          E4438C       MY49071538          2016/12/15     2017/12/15
     Power Detecting &                  R&S            OSP-B157         100914
                                                                                          2016/8/5       2017/8/5
        Sampling Unit
                                                 Software Information
          Test Item                      Software Name                       Manufacturer                 Version
             RE                               EMC32                                R&S                    V9.25.0
             CE                               EMC32                                R&S                    V9.25.0




6    Appendixes


          Appendix No.                                               Description

SYBH(Z-RF)014022017-2004-A                                   Appendix for 2.4G WLAN


                                                       END




Report No:                                   Huawei Proprietary and Confidential                     Page 19 of 19
SYBH(Z-RF)014022017-2004                  Copyright © Huawei Technologies Co., Ltd.



Document Created: 2017-12-28 23:35:27
Document Modified: 2017-12-28 23:35:27

© 2025 FCC.report