SAR Report_Appendix A. System Check Plots

FCC ID: QISSNE-LX3

RF Exposure Info

Download: PDF
FCCID_4004001

         Appendix No.: SYBH(Z-SAR)20180813013001-2A       FCC ID:QISSNE-LX3


                         Appendix A. System Check Plots



                              Table of contents
SystemPerformanceCheck-D750-EX-Head
SystemPerformanceCheck-D835-EX-Head
SystemPerformanceCheck-D1750-EX-Head
SystemPerformanceCheck-D1900-EX-Head
SystemPerformanceCheck-D2450-EX-Head
SystemPerformanceCheck-D2600-EX-Head
SystemPerformanceCheck-D5250-EX-Head
SystemPerformanceCheck-D5600-EX-Head
SystemPerformanceCheck-D5750-EX-Head
SystemPerformanceCheck-D750-EX-Body
SystemPerformanceCheck-D835-EX-Body
SystemPerformanceCheck-D1750-EX-Body
SystemPerformanceCheck-D1900-EX-Body
SystemPerformanceCheck-D2450-EX-Body
SystemPerformanceCheck-D2600-EX-Body
SystemPerformanceCheck-D5250-EX-Body
SystemPerformanceCheck-D5600-EX-Body
SystemPerformanceCheck-D5750-EX-Body


                                                                                  Date: 2018-8-31

Test Laboratory: HUAWEI SAR/HAC Lab

SystemPerformanceCheck-D750-EX-Head

DUT: Dipole 750 MHz D750V3; Type: D750V3; Serial: D750V3 - SN:1044

Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1
Medium parameters used: f = 750 MHz; ı = 0.875 S/m; İr = 41.808; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN7489; ConvF(10.79, 10.79, 10.79) @ 750 MHz; Calibrated: 2018-1-9
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn852; Calibrated: 2018-4-23
   z   Phantom: SAM3; Type: SAM; Serial: 1597
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Configuration/d=15mm, Pin=250mW/Area Scan (6x14x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 2.60 W/kg

Configuration/d=15mm, Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 47.70 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 2.93 W/kg
SAR(1 g) = 2.01 W/kg; SAR(10 g) = 1.34 W/kg
Maximum value of SAR (measured) = 2.64 W/kg




             0 dB = 2.60 W/kg = 4.15 dBW/kg


                                                                                 Date: 2018-9-

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;+HDG

'87'LSROH0+]'97\SH'96HULDO'9 61G

Communication System: UID 0, CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium parameters used: f = 835 MHz; ı = 0.906 S/m; İr = 42.25; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3744; ConvF(8.96, 8.96, 8.96) @ 835 MHz; Calibrated: 2018-7-25
   z   Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM1; Type: SAM; Serial: 1475
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PP3LQ P:$UHD6FDQ [[  Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 2.41 W/kg

&RQILJXUDWLRQG PP3LQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 48.61 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 3.18 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 2.53 W/kg




              0 dB = 2.41 W/kg = 3.82 dBW/kg


                                                                                  'DWH

7HVW/DERUDWRU\+8$:(,6$5+$&/DE

6\VWHP3HUIRUPDQFH&KHFN'(;+HDG

'87'LSROH0+]7\SH'96HULDO'9 61G

&RPPXQLFDWLRQ6\VWHP8,'&:)UHTXHQF\0+]'XW\&\FOH
0HGLXPSDUDPHWHUVXVHGI 0+]ı 6PİU ȡ NJP
3KDQWRPVHFWLRQ)ODW6HFWLRQ

'$6<&RQILJXUDWLRQ

   z   3UREH(;'9 61&RQY)  #0+]&DOLEUDWHG
   z   6HQVRU6XUIDFHPP 0HFKDQLFDO6XUIDFH'HWHFWLRQ ] 
   z   (OHFWURQLFV'$(6Q&DOLEUDWHG
   z   3KDQWRP6$07\SH6$06HULDO
   z   '$6<  6(0&$'; 


&RQILJXUDWLRQG PP3LQ P:$UHD6FDQ [[ 0HDVXUHPHQWJULGG[ PP
G\ PP
0D[LPXPYDOXHRI6$5 PHDVXUHG  :NJ

&RQILJXUDWLRQG PP3LQ P:=RRP6FDQ [[ &XEH0HDVXUHPHQWJULG
G[ PPG\ PPG] PP
5HIHUHQFH9DOXH 9P3RZHU'ULIW G%
3HDN6$5 H[WUDSRODWHG  :NJ
6$5 J  :NJ6$5 J  :NJ
0D[LPXPYDOXHRI6$5 PHDVXUHG  :NJ




             G% :NJ G%:NJ


                                                                               Date: 2018-8-24

Test Laboratory: +8$:(,6$5+$&/DE

6\VWHP3HUIRUPDQFH&KHFN'(;+HDG

'87'LSROH0+]'97\SH'96HULDO'9 61

Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1750 MHz; ı = 1.335 S/m; İr = 38.434; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN7489; ConvF(8.9, 8.9, 8.9) @ 1750 MHz; Calibrated: 2018-1-9
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn852; Calibrated: 2018-4-23
   z   Phantom: SAM3; Type: SAM; Serial: 1597
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PPSLQ P:$UHD6FDQ [[  Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 11.6 W/kg

&RQILJXUDWLRQG PPSLQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 100.7 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 16.0 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 13.8 W/kg




              0 dB = 11.6 W/kg = 10.64 dBW/kg


                                                                                  Date: 2018-8-29

Test Laboratory: +8$:(,6$5+$&/DE

6\VWHP3HUIRUPDQFH&KHFN'(;+HDG

'87'LSROH0+]'97\SH'96HULDO'9 61

Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1750 MHz; ı = 1.31 S/m; İr = 39.874; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN7489; ConvF(8.9, 8.9, 8.9) @ 1750 MHz; Calibrated: 2018-1-9
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn852; Calibrated: 2018-4-23
   z   Phantom: SAM3; Type: SAM; Serial: 1597
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PPSLQ P:$UHD6FDQ [[  Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 11.9 W/kg

&RQILJXUDWLRQG PPSLQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 99.83 V/m; Power Drift = -0.11 dB
Peak SAR (extrapolated) = 15.6 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 13.5 W/kg




              0 dB = 11.9 W/kg = 10.76 dBW/kg


                                                                                  Date: 2018-8-22

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;+HDG

'87'LSROH0+]'97\SH'96HULDO'9 61G

Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1900 MHz; ı = 1.37 S/m; İr = 39.147; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3744; ConvF(7.99, 7.99, 7.99) @ 1900 MHz; Calibrated: 2018-7-25
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM1; Type: SAM; Serial: 1475
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PPSLQ P:$UHD6FDQ [[  Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 14.8 W/kg

&RQILJXUDWLRQG PPSLQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 96.01 V/m; Power Drift = -0.17 dB
Peak SAR (extrapolated) = 20.0 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 16.2 W/kg




             0 dB = 14.8 W/kg = 11.70 dBW/kg


                                                                               Date: 2018-8-28

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;+HDG

'87'LSROH0+]'97\SH'96HULDO'9 61G

Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1900 MHz; ı = 1.446 S/m; İr = 40.972; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3744; ConvF(7.99, 7.99, 7.99) @ 1900 MHz; Calibrated: 2018-7-25
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM1; Type: SAM; Serial: 1475
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PPSLQ P:$UHD6FDQ [[  Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 14.6 W/kg

&RQILJXUDWLRQG PPSLQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 96.58 V/m; Power Drift = -0.18 dB
Peak SAR (extrapolated) = 19.7 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 15.9 W/kg




             0 dB = 14.6 W/kg = 11.64 dBW/kg


                                                                                  Date: 2018-9-2

Test Laboratory: +8$:(,6$5+$&/DE

6\VWHP3HUIRUPDQFH&KHFN'(;+HDG

'87'LSROH0+]'97\SH'96HULDO'9 61

Communication System: UID 0, CW; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium parameters used: f = 2450 MHz; ı = 1.85 S/m; İr = 38.716; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN7489; ConvF(8.04, 8.04, 8.04) @ 2450 MHz; Calibrated: 2018-1-9
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn852; Calibrated: 2018-4-23
   z   Phantom: SAM3; Type: SAM; Serial: 1597
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PP3LQ P:$UHD6FDQ [[  Measurement grid: dx=12mm,
dy=12mm
Maximum value of SAR (measured) = 21.5 W/kg

&RQILJXUDWLRQG PP3LQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 104.0 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 27.8 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 22.5 W/kg




              0 dB = 21.5 W/kg = 13.32 dBW/kg


                                                                                   Date: 2018--

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;+HDG

'87'LSROH0+]'97\SH'96HULDO'9 61

Communication System: UID 0, CW; Frequency: 2600 MHz;Duty Cycle: 1:1
Medium parameters used: f = 2600 MHz; ı = 1.902 S/m; İr = 40.307; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3744; ConvF(6.9, 6.9, 6.9) @ 2600 MHz; Calibrated: 2018-7-25
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM1; Type: SAM; Serial: 1475
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PP3LQ P:$UHD6FDQ [[  Measurement grid: dx=12mm,
dy=12mm
Maximum value of SAR (measured) = 24.6 W/kg

&RQILJXUDWLRQG PP3LQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 102.3 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 31.6 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 24.7 W/kg




              0 dB = 24.6 W/kg = 13.91 dBW/kg


                                                                                  Date: 2018-9-3

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;+HDG

'87'LSROH'*+]97\SH'*+]96HULDO'*+]9 61

Communication System: UID 0, CW (0); Frequency: 5250 MHz;Duty Cycle: 1:1
Medium parameters used: f = 5250 MHz; ı = 4.531 S/m; İr = 35.91; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3736; ConvF(4.73, 4.73, 4.73) @ 5250 MHz; Calibrated: 2018-4-27
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 25.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM1; Type: SAM; Serial: 1475
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


6\VWHP3HUIRUPDQFH&KHFNZLWK'*+]9'LSROH JUDGHGJULG G PP
3LQ P:I 0+]$UHD6FDQ [[  Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 19.5 W/kg

6\VWHP3HUIRUPDQFH&KHFNZLWK'*+]9'LSROH JUDGHGJULG G PP
3LQ P:I 0+]=RRP6FDQ [[PPJUDGHG GLVW PP
 [[ &XEH Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 63.72 V/m; Power Drift = -0.14 dB
Peak SAR (extrapolated) = 33.2 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 19.9 W/kg




             0 dB = 19.5 W/kg = 12.90 dBW/kg


                                                                                   Date: 2018-9-3

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;+HDG

'87'LSROH'*+]97\SH'*+]96HULDO'*+]9 61

Communication System: UID 0, CW (0); Frequency: 5600 MHz;Duty Cycle: 1:1
Medium parameters used: f = 5600 MHz; ı = 4.847 S/m; İr = 34.541; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3736; ConvF(4.38, 4.38, 4.38) @ 5600 MHz; Calibrated: 2018-4-27
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 25.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM1; Type: SAM; Serial: 1475
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


6\VWHP3HUIRUPDQFH&KHFNZLWK'*+]9'LSROH JUDGHGJULG G PP
3LQ P:I 0+]$UHD6FDQ [[  Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 19.2 W/kg

6\VWHP3HUIRUPDQFH&KHFNZLWK'*+]9'LSROH JUDGHGJULG G PP
3LQ P:I 0+]=RRP6FDQ [[PPJUDGHG GLVW PP
 [[ &XEH Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 60.95 V/m; Power Drift = -0.14 dB
Peak SAR (extrapolated) = 32.2 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 18.8 W/kg




             0 dB = 19.2 W/kg = 12.83 dBW/kg


                                                                                   Date: 2018-9-3

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;+HDG

'87'LSROH'*+]97\SH'*+]96HULDO'*+]9 61

Communication System: UID 0, CW (0); Frequency: 5750 MHz;Duty Cycle: 1:1
Medium parameters used: f = 5750 MHz; ı = 5.211 S/m; İr = 35.063; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3736; ConvF(4.62, 4.62, 4.62) @ 5750 MHz; Calibrated: 2018-4-27
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 25.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM1; Type: SAM; Serial: 1475
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


6\VWHP3HUIRUPDQFH&KHFNZLWK'*+]9'LSROH JUDGHGJULG G PP
3LQ P:I 0+]$UHD6FDQ [[  Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 19.0 W/kg

6\VWHP3HUIRUPDQFH&KHFNZLWK'*+]9'LSROH JUDGHGJULG G PP
3LQ P:I 0+]=RRP6FDQ [[PPJUDGHG GLVW PP
 [[ &XEH Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 59.97 V/m; Power Drift = -0.08 dB
Peak SAR (extrapolated) = 34.6 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 20.3 W/kg




             0 dB = 19.0 W/kg = 12.79 dBW/kg


                                                                                  Date: 2018-8-31

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;%RG\

'87'LSROH0+]'97\SH'96HULDO'9 61

Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1
Medium parameters used: f = 750 MHz; ı = 0.948 S/m; İr = 54.218; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN7489; ConvF(11.1, 11.1, 11.1) @ 750 MHz; Calibrated: 2018-1-9
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn852; Calibrated: 2018-4-23
   z   Phantom: SAM4; Type: SAM; Serial: 1620
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PPSLQ P:$UHD6FDQ [[  Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 2.54 W/kg

&RQILJXUDWLRQG PPSLQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 55.24 V/m; Power Drift = -0.17 dB
Peak SAR (extrapolated) = 2.99 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 2.69 W/kg




              0 dB = 2.54 W/kg = 4.05 dBW/kg


                                                                                  Date: 2018-8-30

Test Laboratory: +8$:(,6$5+$&/DE

6\VWHP3HUIRUPDQFH&KHFN'(;%RG\

'87'LSROH0+]'97\SH'96HULDO'9 61G

Communication System: UID 0, CW; Frequency: 835 MHz;Duty Cycle: 1:1
Medium parameters used: f = 835 MHz; ı = 0.958 S/m; İr = 53.661; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN7489; ConvF(10.8, 10.8, 10.8) @ 835 MHz; Calibrated: 2018-1-9
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn852; Calibrated: 2018-4-23
   z   Phantom: SAM4; Type: SAM; Serial: 1620
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PP3LQ P:$UHD6FDQ [[  Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 3.03 W/kg

&RQILJXUDWLRQG PP3LQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 58.46 V/m; Power Drift = -0.12 dB
Peak SAR (extrapolated) = 3.60 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 3.21 W/kg




              0 dB = 3.03 W/kg = 4.81 dBW/kg


                                                                                  'DWH

7HVW/DERUDWRU\+8$:(,6$5+$&/DE

6\VWHP3HUIRUPDQFH&KHFN'(;%RG\

'87'LSROH0+]'97\SH'96HULDO'9 61G

&RPPXQLFDWLRQ6\VWHP8,'&:)UHTXHQF\0+]'XW\&\FOH
0HGLXPSDUDPHWHUVXVHGI 0+]ı 6PİU ȡ NJP
3KDQWRPVHFWLRQ)ODW6HFWLRQ

'$6<&RQILJXUDWLRQ

   z   3UREH(;'9 61&RQY)  #0+]&DOLEUDWHG
   z   6HQVRU6XUIDFHPP 0HFKDQLFDO6XUIDFH'HWHFWLRQ ] 
   z   (OHFWURQLFV'$(6Q&DOLEUDWHG
   z   3KDQWRP6$07\SH4'3$$6HULDO
   z   '$6<  6(0&$'; 


&RQILJXUDWLRQG PP3LQ P:$UHD6FDQ [[ 0HDVXUHPHQWJULGG[ PP
G\ PP
0D[LPXPYDOXHRI6$5 PHDVXUHG  :NJ

&RQILJXUDWLRQG PP3LQ P:=RRP6FDQ [[ &XEH0HDVXUHPHQWJULG
G[ PPG\ PPG] PP
5HIHUHQFH9DOXH 9P3RZHU'ULIW G%
3HDN6$5 H[WUDSRODWHG  :NJ
6$5 J  :NJ6$5 J  :NJ
0D[LPXPYDOXHRI6$5 PHDVXUHG  :NJ




             G% :NJ G%:NJ


                                                                               Date: 2018-8-24

Test Laboratory: +8$:(,6$5+$&/DE

6\VWHP3HUIRUPDQFH&KHFN'(;%RG\

'87'LSROH0+]'97\SH'96HULDO'9 61

Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1750 MHz; ı = 1.489 S/m; İr = 54.155; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN7489; ConvF(8.99, 8.99, 8.99) @ 1750 MHz; Calibrated: 2018-1-9
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn852; Calibrated: 2018-4-23
   z   Phantom: SAM4; Type: SAM; Serial: 1620
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PPSLQ P:$UHD6FDQ [[  Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 10.3 W/kg

&RQILJXUDWLRQG PPSLQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 97.54 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 15.3 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 13.3 W/kg




              0 dB = 10.3 W/kg = 10.13 dBW/kg


                                                                                  Date: 2018-8-28

Test Laboratory: +8$:(,6$5+$&/DE

6\VWHP3HUIRUPDQFH&KHFN'(;%RG\

'87'LSROH0+]'97\SH'96HULDO'9 61

Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1750 MHz; ı = 1.52 S/m; İr = 53.948; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN7489; ConvF(8.99, 8.99, 8.99) @ 1750 MHz; Calibrated: 2018-1-9
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn852; Calibrated: 2018-4-23
   z   Phantom: SAM4; Type: SAM; Serial: 1620
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PPSLQ P:$UHD6FDQ [[  Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 10.6 W/kg

&RQILJXUDWLRQG PPSLQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 97.56 V/m; Power Drift = -0.16 dB
Peak SAR (extrapolated) = 16.0 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 13.9 W/kg




              0 dB = 10.6 W/kg = 10.25 dBW/kg


                                                                                  Date: 2018-8-

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;%RG\

'87'LSROH0+]'97\SH'96HULDO'9 61G

Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1900 MHz; ı = 1.58 S/m; İr = 51.656; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3744; ConvF(7.6, 7.6, 7.6) @ 1900 MHz; Calibrated: 2018-7-25
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM2; Type: SAM; Serial: 1474
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PPSLQ P:$UHD6FDQ [[  Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 13.2 W/kg

&RQILJXUDWLRQG PPSLQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 105.3 V/m; Power Drift = 0.11 dB
Peak SAR (extrapolated) = 19.8 W/kg
6$5 J  :NJ6$5 J  :NJ


Maximum value of SAR (measured) = 16.6 W/kg




              0 dB = 13.2 W/kg = 11.21 dBW/kg


                                                                               Date: 2018-8-26

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;%RG\

'87'LSROH0+]'97\SH'96HULDO'9 61G

Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1900 MHz; ı = 1.573 S/m; İr = 51.138; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3744; ConvF(7.6, 7.6, 7.6) @ 1900 MHz; Calibrated: 2018-7-25
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM2; Type: SAM; Serial: 1474
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PPSLQ P:$UHD6FDQ [[  Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 12.7 W/kg

&RQILJXUDWLRQG PPSLQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 102.8 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 19.3 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 16.3 W/kg




              0 dB = 12.7 W/kg = 11.04 dBW/kg


                                                                                   Date: 2018-9-2

Test Laboratory: +8$:(,6$5+$&/DE

6\VWHP3HUIRUPDQFH&KHFN'(;%RG\

'87'LSROH0+]'97\SH'96HULDO'9 61

Communication System: UID 0, CW; Frequency: 2450 MHz;Duty Cycle: 1:1
Medium parameters used: f = 2450 MHz; ı = 2.022 S/m; İr = 51.218; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN7489; ConvF(8.24, 8.24, 8.24) @ 2450 MHz; Calibrated: 2018-1-9
   z   Sensor-Surface: 3mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn852; Calibrated: 2018-4-23
   z   Phantom: SAM4; Type: SAM; Serial: 1620
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PP3LQ P:$UHD6FDQ [[  Measurement grid: dx=12mm,
dy=12mm
Maximum value of SAR (measured) = 14.2 W/kg

&RQILJXUDWLRQG PP3LQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 86.47 V/m; Power Drift = -0.18 dB
Peak SAR (extrapolated) = 23.8 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 15.7 W/kg




              0 dB = 14.2 W/kg = 11.52 dBW/kg


                                                                                  Date: 2018--

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;%RG\

'87'LSROH0+]'97\SH'96HULDO'9 61

Communication System: UID 0, CW; Frequency: 2600 MHz;Duty Cycle: 1:1
Medium parameters used: f = 2600 MHz; ı = 2.21 S/m; İr = 51.012; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3744; ConvF(7.35, 7.35, 7.35) @ 2600 MHz; Calibrated: 2018-7-25
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 31.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM2; Type: SAM; Serial: 1474
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


&RQILJXUDWLRQG PP3LQ P:$UHD6FDQ [[  Measurement grid: dx=12mm,
dy=12mm
Maximum value of SAR (measured) = 23.3 W/kg

&RQILJXUDWLRQG PP3LQ P:=RRP6FDQ [[ &XEH Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 104.2 V/m; Power Drift = 0.09 dB
Peak SAR (extrapolated) = 32.0 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 25.2 W/kg




             0 dB = 23.3 W/kg = 13.67 dBW/kg


                                                                                   Date: 2018-9-4

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;%RG\

'87'LSROH'*+]97\SH'*+]96HULDO'*+]9 61

Communication System: UID 0, CW (0); Frequency: 5250 MHz;Duty Cycle: 1:1
Medium parameters used: f = 5250 MHz; ı = 5.428 S/m; İr = 47.647; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3736; ConvF(4.01, 4.01, 4.01) @ 5250 MHz; Calibrated: 2018-4-27
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 25.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM2; Type: SAM; Serial: 1474
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


6\VWHP3HUIRUPDQFH&KHFNZLWK'*+]9'LSROH JUDGHGJULG G PP
3LQ P:I 0+]$UHD6FDQ [[  Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 17.6 W/kg

6\VWHP3HUIRUPDQFH&KHFNZLWK'*+]9'LSROH JUDGHGJULG G PP
3LQ P:I 0+]=RRP6FDQ [[PPJUDGHG GLVW PP
 [[ &XEH Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 62.19 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 29.2 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 17.7 W/kg




             0 dB = 17.6 W/kg = 12.46 dBW/kg


                                                                                   Date: 2018-9-4

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;%RG\

'87'LSROH'*+]97\SH'*+]96HULDO'*+]9 61

Communication System: UID 0, CW (0); Frequency: 5600 MHz;Duty Cycle: 1:1
Medium parameters used: f = 5600 MHz; ı = 5.631 S/m; İr = 48.296; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3736; ConvF(3.58, 3.58, 3.58) @ 5600 MHz; Calibrated: 2018-4-27
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 25.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM2; Type: SAM; Serial: 1474
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


6\VWHP3HUIRUPDQFH&KHFNZLWK'*+]9'LSROH JUDGHGJULG G PP
3LQ P:I 0+]$UHD6FDQ [[  Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 14.4 W/kg

6\VWHP3HUIRUPDQFH&KHFNZLWK'*+]9'LSROH JUDGHGJULG G PP
3LQ P:I 0+]=RRP6FDQ [[PPJUDGHG GLVW PP
 [[ &XEH Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 71.14 V/m; Power Drift = 0.16 dB
Peak SAR (extrapolated) = 38.0 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 20.8 W/kg




             0 dB = 14.4 W/kg = 11.58 dBW/kg


                                                                                   Date: 2018-9-4

Test Laboratory: HUAWEI SAR/HAC Lab

6\VWHP3HUIRUPDQFH&KHFN'(;%RG\

'87'LSROH'*+]97\SH'*+]96HULDO'*+]9 61

Communication System: UID 0, CW (0); Frequency: 5750 MHz;Duty Cycle: 1:1
Medium parameters used: f = 5750 MHz; ı = 6.074 S/m; İr = 47.747; ȡ = 1000 kg/m3
Phantom section: Flat Section

DASY Configuration:

   z   Probe: EX3DV4 - SN3736; ConvF(3.93, 3.93, 3.93) @ 5750 MHz; Calibrated: 2018-4-27
   z   Sensor-Surface: 1.4mm (Mechanical Surface Detection), z = 1.0, 25.0
   z   Electronics: DAE4 Sn851; Calibrated: 2018-7-18
   z   Phantom: SAM2; Type: SAM; Serial: 1474
   z   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


6\VWHP3HUIRUPDQFH&KHFNZLWK'*+]9'LSROH JUDGHGJULG G PP
3LQ P:I 0+]$UHD6FDQ [[  Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 19.2 W/kg

6\VWHP3HUIRUPDQFH&KHFNZLWK'*+]9'LSROH JUDGHGJULG G PP
3LQ P:I 0+]=RRP6FDQ [[PPJUDGHG GLVW PP
 [[ &XEH Measurement grid: dx=4mm, dy=4mm, dz=1.4mm
Reference Value = 55.92 V/m; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 35.6 W/kg
6$5 J  :NJ6$5 J  :NJ
Maximum value of SAR (measured) = 19.8 W/kg




             0 dB = 19.2 W/kg = 12.83 dBW/kg


                                  System Validation

Per FCC KDB 865664 D02, SAR system verification is required to confirm measurement

accuracy. The SAR systems (including SAR probes, system components and software

versions) used for this device were validated against its performance specifications prior

to the SAR measurements. Reference dipoles are used with the required tissue-

equivalent media for system validation, according to the procedures outlined in FCC

KDB 865664 D01 and IEEE 1528-2013.Since SAR probe calibrations are frequency

dependent, each probe calibration point must be validated at a frequency within the valid

frequency range of the probe calibration point, using the system that normally operates

with the probe for routine SAR measurements and according to the required tissue-

equivalent media.a tabulated summary of the system validation status, measurement

frequencies, SARprobes, calibrated signal type(s) and tissue dielectric parameters has

been included.


                              Table of SAR System validation summary:




                                                   PERM    COND               CW VALIDATION                     MOD.VALIDATION


FREQ.               PROBE   PROBE    PROBE CAL
         DATE
[Mhz]                 SN     TYPE      POINT


                                                                                   PROBE        PROBE    MOD.       DUTY.
                                                   (εr)     (σ)    SENSI-TIVITY                                                  PAR
                                                                                  LINARITY    ISOTROPY   TYPE      FACTORE



 835    2018-8-22   3744    EX3DV4   835    Head   42.18   0.864      PASS         PASS        PASS      GMSK        PASS        N/A

1750    2018-8-23   3744    EX3DV4   1750   Head   38.48   1.347      PASS         PASS        PASS       NA          NA         N/A

1900    2018-8-22   3744    EX3DV4   1900   Head   39.15   1.370      PASS         PASS        PASS      GMSK        PASS        N/A

2450    2018-8-27   3744    EX3DV4   2450   Head   38.14   1.759      PASS         PASS        PASS      OFDM        PASS        PASS

2600    2018-8-24   3744    EX3DV4   2600   Head   40.31   1.903      PASS         PASS        PASS      TDD         PASS        N/A

5250    2018-8-27   3744    EX3DV4   5250   Head   35.43   4.889      PASS         PASS        PASS      OFDM        N/A         PASS

 835    2018-8-22   3744    EX3DV4   835    Head   53.71   0.994      PASS         PASS        PASS      GMSK        PASS        N/A

1750    2018-8-22   3744    EX3DV4   1750   Body   54.25   1.493      PASS         PASS        PASS      N/A         N/A         N/A

1900    2018-8-26   3744    EX3DV4   1900   Body   51.14   1.573      PASS         PASS        PASS      GMSK        PASS        N/A

2450    2018-8-27   3744    EX3DV4   2450   Body   50.95   1.941      PASS         PASS        PASS      OFDM        PASS        PASS

2600    2018-8-24   3744    EX3DV4   2600   Body   50.15   2.160      PASS         PASS        PASS      TDD         PASS        N/A

5750    2018-8-27   3744    EX3DV4   5750   Body   46.75   5.818      PASS         PASS        PASS      OFDM        N/A         PASS


                             Table of SAR System validation summary:


                                                           CON
FREQ.                                              PERM                         CW VALIDATION                     MOD.VALIDATION
                    PROBE   PROBE    PROBE CAL              D
         DATE
                     SN     TYPE        POINT                      SENSI-TIVI     PROBE          PROBE     MOD.        DUTY.
[Mhz]                                               (εr)    (σ)                                                                    PAR
                                                                      TY         LINARITY       ISOTROPY   TYPE      FACTORE


 835    2017/12/7   3736    EX3DV4   835    Head   41.88   0.897     PASS          PASS          PASS      GMSK        PASS        N/A


1750    2017/12/7   3736    EX3DV4   1750   Head   39.92   1.382     PASS          PASS          PASS       NA          NA         N/A


1900    2017/12/7   3736    EX3DV4   1900   Head   39.64   1.446     PASS          PASS          PASS      GMSK        PASS        N/A


2450    2017/12/7   3736    EX3DV4   2450   Head   38.85   1.859     PASS          PASS          PASS      OFDM        PASS        PASS


2600    2017/12/7   3736    EX3DV4   2600   Head   38.56   1.976     PASS          PASS          PASS      TDD         PASS        N/A


5250    2017/12/7   3736    EX3DV4   5250   Head   34.52   4.528     PASS          PASS          PASS      OFDM         N/A        PASS


5600    2017/12/7   3736    EX3DV4   5600   Head   33.89   4.905     PASS          PASS          PASS      OFDM         N/A        PASS


5750    2017/12/7   3736    EX3DV4   5750   Head   33.63   5.077     PASS          PASS          PASS      OFDM         N/A        PASS


 835    2017/12/7   3736    EX3DV4   835    Body   56.40   0.971     PASS          PASS          PASS      GMSK        PASS        N/A


1750    2017/12/7   3736    EX3DV4   1750   Body   54.73   1.476     PASS          PASS          PASS      N/A          N/A        N/A


1900    2017/12/7   3736    EX3DV4   1900   Body   54.49   1.568     PASS          PASS          PASS      GMSK        PASS        N/A


2450    2017/12/7   3736    EX3DV4   2450   Body   53.72   2.061     PASS          PASS          PASS      OFDM        PASS        PASS


2600    2017/12/7   3736    EX3DV4   2600   Body   53.42   2.205     PASS          PASS          PASS      TDD         PASS        N/A


5250    2017/12/7   3736    EX3DV4   5250   Body   48.26   5.490     PASS          PASS          PASS      OFDM         N/A        PASS


5600    2017/12/7   3736    EX3DV4   5600   Body   47.58   5.993     PASS          PASS          PASS      OFDM         N/A        PASS


5750    2017/12/7   3736    EX3DV4   5750   Body   47.31   6.226     PASS          PASS          PASS      OFDM         N/A        PASS


FREQ.                                               PERM    COND               CW VALIDATION                       MOD.VALIDATION
                     PROBE   PROBE    PROBE CAL
         DATE                                                                      PROBE        PROBE                    DUTY.
[Mhz]                 SN     TYPE        POINT      (εr)     (σ)    SENSI-TIVITY                          MOD. TYPE                 PAR
                                                                                   LINARITY    ISOTROPY                FACTORE

 750    2018/02/08    7489   EX3DV4   750    Head   41.04   0.874      PASS         PASS         PASS        N/A          N/A       N/A

 835    2018/02/08    7489   EX3DV4   835    Head   40.80   0.902      PASS         PASS         PASS       GMSK         PASS       N/A

 900    2018/02/08    7489   EX3DV4   900    Head   38.87   1.313      PASS         PASS         PASS       GMSK         PASS       N/A

1750    2018/02/08    7489   EX3DV4   1750   Head   38.87   1.313      PASS         PASS         PASS        NA           NA        N/A

1900    2018/02/08    7489   EX3DV4   1900   Head   38.67   1.410      PASS         PASS         PASS       GMSK         PASS       N/A

2000    2018/02/08    7489   EX3DV4   2000   Head   38.51   1.469      PASS         PASS         PASS        N/A          N/A       N/A

2300    2018/02/08    7489   EX3DV4   2300   Head   38.11   1.672      PASS         PASS         PASS        N/A          N/A       N/A

2450    2018/02/08    7489   EX3DV4   2450   Head   37.91   1.785      PASS         PASS         PASS     OFDM/TDD       PASS       PASS

2600    2018/02/08    7489   EX3DV4   2600   Head   37.75   1.905      PASS         PASS         PASS        TDD         PASS       N/A

5250    2018/02/08    7489   EX3DV4   5250   Head   35.52   4.674      PASS         PASS         PASS       OFDM         PASS       N/A

5600    2018/02/08    7489   EX3DV4   5600   Head   34.89   5.071      PASS         PASS         PASS       OFDM         PASS       N/A

5750    2018/02/08    7489   EX3DV4   5750   Head   34.64   5.237      PASS         PASS         PASS       OFDM         PASS       N/A

 750    2018/02/08    7489   EX3DV4   750    Body   55.56   0.942      PASS         PASS         PASS        N/A          N/A       N/A

 835    2018/02/08    7489   EX3DV4   835    Body   55.35   0.974      PASS         PASS         PASS       GMSK         PASS       N/A

1750    2018/02/08    7489   EX3DV4   1750   Body   53.56   1.454      PASS         PASS         PASS        N/A          N/A       N/A

1900    2018/02/08    7489   EX3DV4   1900   Body   53.38   1.574      PASS         PASS         PASS       GMSK         PASS       N/A

2300    2018/02/08    7489   EX3DV4   2300   Body   52.84   1.893      PASS         PASS         PASS        N/A          N/A       N/A

2450    2018/02/08    7489   EX3DV4   2450   Body   52.63   2.032      PASS         PASS         PASS     OFDM/TDD       PASS       PASS

2600    2018/02/08    7489   EX3DV4   2600   Body   52.46   2.178      PASS         PASS         PASS        TDD         PASS       N/A

5250    2018/02/08    7489   EX3DV4   5250   Body   47.45   5.479      PASS         PASS         PASS       OFDM         PASS       N/A

5600    2018/02/08    7489   EX3DV4   5600   Body   46.74   5.984      PASS         PASS         PASS       OFDM         PASS       N/A

5750    2018/02/08    7489   EX3DV4   5750   Body   46.44   6.210      PASS         PASS         PASS       OFDM         PASS       N/A


                                                            CON
FREQ.                                               PERM                         CW VALIDATION                  MOD.VALIDATION
                     PROBE   PROBE    PROBE CAL              D
         DATE
                      SN     TYPE        POINT                      SENSI-TIVI     PROBE         PROBE   MOD.       DUTY.
[Mhz]                                                (εr)    (σ)                                                                 PAR
                                                                       TY         LINARITY   ISOTROPY    TYPE      FACTORE

 835    2017/11/24   7381    EX3DV4   835    Head   42.28   0.930     PASS          PASS         PASS    GMSK        PASS        N/A


1750    2017/11/25   7381    EX3DV4   1750   Head   40.24   1.301     PASS          PASS         PASS     NA          NA         N/A


1900    2017/11/23   7381    EX3DV4   1900   Head   40.34   1.367     PASS          PASS         PASS    GMSK        PASS        N/A


2450    2017/11/25   7381    EX3DV4   2450   Head   39.03   1.845     PASS          PASS         PASS    OFDM        PASS        PASS


2600    2017/11/21   7381    EX3DV4   2600   Head   39.56   1.855     PASS          PASS         PASS    TDD         PASS        N/A


5250    2017/12/03   7381    EX3DV4   5250   Head   35.86   4.676     PASS          PASS         PASS    OFDM        N/A         PASS


5600    2017/12/07   7381    EX3DV4   5600   Head   35.79   4.914     PASS          PASS         PASS    OFDM        N/A         PASS


5750    2017/12/06   7381    EX3DV4   5750   Head   35.32   5.269     PASS          PASS         PASS    OFDM        N/A         PASS


 835    2017/11/19   7381    EX3DV4   835    Body   53.63   0.984     PASS          PASS         PASS    GMSK        PASS        N/A


1750    2017/11/26   7381    EX3DV4   1750   Body   51.56   1.422     PASS          PASS         PASS    N/A         N/A         N/A


1900    2017/11/24   7381    EX3DV4   1900   Body   52.95   1.565     PASS          PASS         PASS    GMSK        PASS        N/A


2450    2017/11/27   7381    EX3DV4   2450   Body   51.54   1.875     PASS          PASS         PASS    OFDM        PASS        PASS


2600    2017/11/22   7381    EX3DV4   2600   Body   50.94   2.202     PASS          PASS         PASS    TDD         PASS        N/A


5250    2017/12/03   7381    EX3DV4   5250   Body   47.55   5.358     PASS          PASS         PASS    OFDM        N/A         PASS


5600    2017/12/09   7381    EX3DV4   5600   Body   47.34   5.911     PASS          PASS         PASS    OFDM        N/A         PASS


5750    2017/12/06   7381    EX3DV4   5750   Body   47.43   5.978     PASS          PASS         PASS    OFDM        N/A         PASS


NOTE: While the probes have been calibrated for both CW and modulated signals, all

measurements were performed using communication systems calibrated for CW

signals only. Modulations in the table above represent test configurations for which

the measurement system has been validated per FCC KDB Publication 865664D01 for

scenarios when CW probe calibrations are used with other signal types. SAR systems

were validated for modulated signals with a periodic duty cycle, such as GMSK, or with

a high peak to average ratio (>5dB), such as OFDM according to KDB

865664.



Document Created: 2018-09-11 10:09:30
Document Modified: 2018-09-11 10:09:30

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC