      Report Number                                        : 68.760.18.0480.01                                   Date of Issue:              August 6, 2018


      Model                                                : CP60

      Product Type                                         : HUAWEI WIRELESS CHARGER

      Applicant                                            : Huawei Technologies Co., Ltd.

      Address                                              : Administration Building, Headquarters of Huawei Technologies Co.,

                                                           : Ltd., Bantian, Longgang District, Shenzhen, 518129, P.R.C

      Manufacturer                                         : Huawei Technologies Co., Ltd.

      Address                                              : Administration Building, Headquarters of Huawei Technologies Co.,

                                                           : Ltd., Bantian, Longgang District, Shenzhen, 518129, P.R.C


      Test Result                                          : n Positive                   o Negative



      Total pages including
      Appendices                                           : 18

  TÜV SÜD Certification and Testing (China) Co., Ltd. – Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles
  outlined in ISO 17025.


  TÜV SÜD Certification and Testing (China) Co., Ltd. – Shenzhen Branch reports apply only to the specific samples tested under stated test
  conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this
  model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe
  for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co.,
  Ltd. – Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and
  Testing (China) Co., Ltd. – Shenzhen Branch issued reports.


  This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
  reproduced except in full without our written approval




  v



EMC_SZ_FR_22.03 FCC                                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                                   Page 1 of 18
                                           Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01


      1.       Table of Contents
  1.         Table of Contents .................................................................................................................................... 2
  2.         Details about the Test Laboratory ............................................................................................................ 3
  3.         Description of the Equipment Under Test ................................................................................................. 4
  4.         Summary of Test Standards..................................................................................................................... 5
  5.         Summary of Test Results ......................................................................................................................... 6
  6.         General Remarks..................................................................................................................................... 7
  7.         Test Setups ............................................................................................................................................. 8
  8.         Systems test configuration ....................................................................................................................... 9
  9.         Technical Requirement .......................................................................................................................... 10
       9.1      Conducted Emission Test .................................................................................................................. 10
       9.2      Radiated Emission Test for 9KHz-30MHz ........................................................................................... 13
       9.3      Radiated Emission Test for 30MHz-1GHz .......................................................................................... 15
  10.        Test Equipment List ............................................................................................................................... 17
  11.        Measurement System Uncertainty.......................................................................................................... 18




  v



EMC_SZ_FR_22.03 FCC                                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                               Page 2 of 18
                                          Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01


      2.     Details about the Test Laborator y
      Details about the Test Laboratory

      Company name:      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                         Building 12&13, Zhiheng Wisdomland Business Park,
                         Nantou Checkpoint Road 2, Nanshan District,
                         Shenzhen City, 518052,
                         P. R. China

      FCC Registration   514049
      Number:

      IC Registration    10320A
      No.:

      Telephone:         86 755 8828 6998
      Fax:               86 755 8828 5299




  v



EMC_SZ_FR_22.03 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 3 of 18
                          Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01


      3.        Description of the Equipment Under Test
      Product:                             HUAWEI WIRELESS CHARGER

      Model no.:                           CP60

      FCC ID:                              QISCP60

      Options and accessories:             Adapter and USB Cable

      Rating:                              5-12Vdc 2A Max supplied by an external adapter

      Adapter information:                 Manufacturer: Huawei Technologies Co., Ltd.
                                           Model: HW-100400U00
                                           Input voltage:100-240V 50/60Hz 1.2A
                                           Output voltage:5V     2A or 9V     2A or 10V                                  4A Max

      RF Transmission Frequency:           111-148KHz

      Antenna Type:                        Integrated loop antenna

      Description of the EUT:              The Equipment Under Test (EUT) is a wireless charger which operated
                                           at 111-148kHz.




  v



EMC_SZ_FR_22.03 FCC                           TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 4 of 18
                                Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                     Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01


      4.     Summary of Test Standards
                                                   Test Standards
      FCC Part 18
                               Industrial, Scientific, and Medical equipment
      10-1-17 Edition




  v



EMC_SZ_FR_22.03 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 5 of 18
                          Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01



      5.    Summary of Test Results
                                              Technical Requirements
      FCC Part 18 10-1-17 Edition
      Test Condition                                                                                     Pages              Test Result
      §18.307                   Conducted emission AC power port                                            10                 Pass

      §18.301                   Operating frequencies                                                        --                N/A

      §18.305                   Field strength                                                              13                 Pass

      §18.309                   Frequency range                                                       See note 2               Pass

      §18.303                   Prohibited frequency bands                                            See note 3               Pass


  Note 1: N/A=Not Applicable.
  Note 2: Because the highest frequency of the internal sources of the EUT is less than 108MHz, so the
  measurement only is made up to 1GHz.
  Note 3: The fundamental frequency of this product is 111-148KHz. Outside the band specified of
  §18.303, it is considered sufficiently to comply with the provisions of this section.




  v



EMC_SZ_FR_22.03 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                    Page 6 of 18
                           Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01


      6.     General Remarks
  Remarks

  This submittal(s) (test report) is intended for FCC ID: QISCP60, complies with FCC Part 18.

  SUMMARY:

  All tests according to the regulations cited on page 5 were


  n - Performed

  o - Not Performed


  The Equipment under Test


  n - Fulfills the general approval requirements.

  o - Does not fulfill the general approval requirements.

      Sample Received Date:                            July 30, 2018

      Testing Start Date:                            August 1, 2018

      Testing End Date:                              August 2, 2018


  - TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch -



      Reviewed by:                           Prepared by:                                          Tested by:




        _______________________                    _______________________                              _______________________
                 John Zhi                                   Alan Xiong                                            Tree Zhan
             Project Manager                              Project Engineer                                       Test Engineer




  v



EMC_SZ_FR_22.03 FCC                          TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 7 of 18
                               Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                    Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01


  7.     Test Setups
  Below 30MHz




  30MHz-1GHz




  AC Power Line Conducted Emission test setups




  v



EMC_SZ_FR_22.03 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 8 of 18
                          Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01



  8.     Systems test configuration
  Auxiliary Equipment Used during Test:

          Description               Manufacturer                          Model NO.                                 S/N
          Mobile Phone                HUAWEI                                 ---                                     ---

          Description                    Length                   Shielded/unshielded                  With / without ferrite
          USB Cable                       1.0m                          Shielded                          Without ferrite




  v



EMC_SZ_FR_22.03 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 9 of 18
                          Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01



      9.    Technical Requirement
      9.1   Conducted Emission Test
  Test Method
     1. The EUT was placed on a table, which is 0.8m above ground plane
     2. The power line of the EUT is connected to the AC mains through an Artificial Mains Network
        (A.M.N.).
     3. Maximum procedure was performed to ensure EUT compliance
     4. A EMI test receiver is used to test the emissions from both sides of AC line

  Limit
  According to §18.307, conducted emissions limit as below:

                          Frequency                         QP Limit                        AV Limit
                             MHz                             dBμV                            dBμV
                          0.150-0.500                        66-56*                          56-46*
                            0.500-5                            56                              46
                             5-30                              60                              50

  *Decreasing linearly with logarithm of the frequency




  v



EMC_SZ_FR_22.03 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 10 of 18
                           Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01


      Conducted Emission

      Product Type                     :    HUAWEI WIRELESS CHARGER
      M/N                              :    CP60
      Operating Condition              :    Charging Mode
      Test Specification               :    Line
      Comment                          :    AC 120V/60Hz


                                80

                                70

                                60
                 Level in dB礦




                                50

                                40

                                30

                                20

                                10

                                0
                                150k        300 400 500         800 1M             2M       3M 4M 5M 6             8 10M          20M        30M
                                                                             Frequency in Hz

                                           Frequency       MaxPeak       Average        Limit     Margin      Line    Corr.
                                             (MHz)          (dBµV)       (dBµV)        (dBµV)      (dB)               (dB)
                                              0.166000         53.33           ---       65.16      11.83     L1       10.2
                                              0.282000         47.65           ---       60.76      13.11     L1       10.2
                                              0.678500            ---       26.98        46.00      19.02     L1       10.2
                                              0.678500         38.86           ---       56.00      17.14     L1       10.2
                                              0.730500            ---       24.30        46.00      21.70     L1       10.2
                                              0.730500         34.18           ---       56.00      21.82     L1       10.2
                                              1.290000         44.14           ---       56.00      11.86     L1       10.2
                                              5.510000         42.28           ---       60.00      17.72     L1       10.4

  *Correct factor=cable loss + LISN factor




  v



EMC_SZ_FR_22.03 FCC                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                      Page 11 of 18
                                            Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01


      Conducted Emission

      Product Type                     :     HUAWEI WIRELESS CHARGER
      M/N                              :     CP60
      Operating Condition              :     Charging Mode
      Test Specification               :     Neutral
      Comment                          :     AC 120V/60Hz


                                80

                                70

                                60
                 Level in dB礦




                                50

                                40

                                30

                                20

                                10

                                0
                                150k         300 400 500        800 1M             2M       3M 4M 5M 6             8 10M          20M        30M
                                                                             Frequency in Hz

                                           Frequency      QuasiPeak       Average        Limit     Margin      Line    Corr.
                                             (MHz)         (dBµV)          (dBµV)       (dBµV)      (dB)               (dB)
                                              0.169500            ---        40.43        54.98      14.55     N        10.3
                                              0.169500         53.48            ---       64.98      11.50     N        10.3
                                              0.229500            ---        34.72        52.47      17.75     N        10.3
                                              0.229500         50.31            ---       62.47      12.16     N        10.3
                                              0.281500            ---        34.73        50.77      16.04     N        10.3
                                              0.281500         48.09            ---       60.77      12.68     N        10.3
                                              0.329500            ---        24.92        49.46      24.54     N        10.3
                                              0.329500         45.13            ---       59.46      14.33     N        10.3
                                              0.658500            ---        25.58        46.00      20.42     N        10.4
                                              0.658500         43.23            ---       56.00      12.77     N        10.4
                                              0.729500            ---        32.79        46.00      13.21     N        10.4
                                              0.729500         43.15            ---       56.00      12.85     N        10.4


  *Correct factor=cable loss + LISN factor




  v



EMC_SZ_FR_22.03 FCC                                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                      Page 12 of 18
                                            Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01



      9.2      Radiated Emission Test for 9KHz-30MHz
  Test Method
  1: Field strength measurements are made in the frequency range of 9 kHz to 30 MHz using a
  calibrated loop antenna as specified in ANSI C63.4 clause 4.5.2, positioned with its plane vertical at
  the specified distance from the EUT and rotated about its vertical axis for maximum response at each
  azimuth about the EUT. The center of the loop shall be 1 m above the ground. This method is
  applicable for radiated radio-noise measurements from all units, cables, power cords, and interconnect
  cabling or wiring.
  2: For certain applications, the loop antenna plane may also need to be positioned horizontally at the
  specified distance from the EUT.

  Limits

  According to §18.307, Field strength limit as below:

            Equipment         Operating frequency                RF Power                    Field strength limit                  Distance
                                                                 generated by                (uV/m)                                (meters)
                                                                 equipment (watts)
            Any type          Any ISM frequency                  Below 500                   25                                    300
            unless                                               500 or more                 25 × SQRT(power/500)                  1300

            otherwise         Any non-ISM frequency              Below 500                   15                                    300
            specified                                            500 or more                 15 × SQRT(power/500)                  1300

            (miscellaneous)
            Industrial        On or below 5,725 MHz              Any                         10                                    1,600
            heaters and RF    Above 5,725 MHz                    Any                         (2)                                   (2)
            stabilized arc
            welders
            Medical           Any ISM frequency                  Any                         25                                    300
            diathermy         Any non-ISM frequency              Any                         15                                    300
            Ultrasonic        Below 490 kHz                      Below 500                   2,400/F(kHz)                          300
                                                                 500 or more                 2,400/F(kHz) ×                        3300

                                                                                             SQRT(power/500)
                              490 to 1,600 kHz                   Any                         24,000/F(kHz)                         30
                              Above 1,600 kHz                    Any                         15                                    30
            Induction         Below 90 kHz                       Any                         1,500                                 430

            cooking ranges    On or above 90 kHz                 Any                         300                                   430

            1Field strength may not exceed 10 μV/m at 1600 meters. Consumer equipment operating below 1000
            MHz is not permitted the increase in field strength otherwise permitted here for power over 500 watts.
            2Reduced to the greatest extent possible.
            3Field strength may not exceed 10 μV/m at 1600 meters. Consumer equipment is not permitted the

            increase in field strength otherwise permitted here for over 500 watts.
            4Induction cooking ranges manufactured prior to February 1, 1980, shall be subject to the field

            strength limits for miscellaneous ISM equipment.

  Note 1: Limit 3m(dBμV/m)=Limit 300m(dBμV/m)+40Log(300m/3m) (Below 30MHz)
  Note 2: Limit 3m(dBμV/m)=Limit 300m(dBμV/m)+20Log(300m/3m) (Above 30MHz)
  Note 3: this product is a wireless charger which operated at 111-148kHz. So, it belongs to miscellaneous with
  non-SIM frequency.




  v



EMC_SZ_FR_22.03 FCC                             TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                       Page 13 of 18
                                  Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                       Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01


  Radiated Emission for 9KHz-30MHz

      Product Type          :   HUAWEI WIRELESS CHARGER
      M/N                   :   CP60
      Operating Condition   :   Charging Mode
      Comment               :   9KHz-30MHz

                                    Emission                                                                            Correct
       Frequency    Frequency                         Polarization          Limit        Detector         Margin                  Result
                                      Level                                                                              factor
         Band
                        MHz          dBμV/m                               dBμV/m                         dBμV/m           (dB)
                        0.149         56.47                  H             103.52            QP           47.03           19.7     Pass
                        0.150         66.02                  H             103.52            QP           37.48           19.7     Pass
                        0.195         55.21                  H             103.52            QP           48.29           19.7     Pass
         9KHz-          0.245         53.48                  H             103.52            QP           50.02           19.7     Pass
         30MHz        0.00900         54.62                  V             103.52            QP           48.88           20.8     Pass
                        0.149         57.41                  V             103.52            QP           46.09           19.7     Pass
                        0.150         62.10                  V             103.52            QP           41.40           19.7     Pass
                       0.0240         52.04                  V             103.52            QP           51.46           20.0     Pass

  Remark:
     1) Corrector factor = Antenna Factor + Cable Loss
     2) The worst case data were reported and no other spurious and harmonics emissions were reported
        greater than listed emission above table.




  v



EMC_SZ_FR_22.03 FCC                           TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 14 of 18
                                Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                     Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01



      9.3      Radiated Emission Test for 30MHz-1GHz
  Test Method
     1: The EUT was place on a turn table which is 0.8m above ground for below 1GHz at 3 meters
     chamber room for test. The table was rotated 360 degrees to determine the position of the highest
     radiation.
     2: The EUT was set 3 meters away from the interference – receiving antenna, which was mounted
     on the top of a variable – height antenna tower.
     3: The height of antenna is varied from one meter to four meters above the ground to determine the
     maximum value of the field strength. Both horizontal and vertical polarizations of the antenna are
     set to make the measurement.
     4: For each suspected emission, the EUT was arranged to its worst case and then the antenna was
     tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360
     degrees to find the maximum reading.
     5: Use the following spectrum analyzer settings According to C63.4:
         Span = wide enough to capture the peak level of the in-band emission and all spurious
         RBW = 100 KHz, VBW≥RBW for peak measurement, Sweep = auto, Detector function = peak,
         Trace = max hold.
  Note:
         1: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120 KHz
         for Quasi-peak detection (QP) at frequency below 1GHz.

  Limits
  According to §18.307, Field strength limit as below:
            Equipment         Operating frequency               RF Power                    Field strength limit                  Distance
                                                                generated by                (μV/m)                                (meters)
                                                                equipment (watts)
            Any type          Any ISM frequency                 Below 500                   25                                    300
                                                                                                                                  1
            unless                                              500 or more                 25 × SQRT(power/500)                   300
            otherwise         Any non-ISM frequency             Below 500                   15                                    300
            specified                                           500 or more                 15 × SQRT(power/500)                  1
                                                                                                                                   300
            (miscellaneous)
            Industrial        On or below 5,725 MHz             Any                         10                                    1,600
            heaters and RF    Above 5,725 MHz                   Any                         (2)                                   (2)
            stabilized arc
            welders
            Medical           Any ISM frequency                 Any                         25                                    300
            diathermy         Any non-ISM frequency             Any                         15                                    300
            Ultrasonic        Below 490 kHz                     Below 500                   2,400/F(kHz)                          300
                                                                500 or more                 2,400/F(kHz) ×                        3300

                                                                                            SQRT(power/500)
                              490 to 1,600 kHz                  Any                         24,000/F(kHz)                         30
                              Above 1,600 kHz                   Any                         15                                    30
                                                                                                    4
       Induction            Below 90 kHz              Any                 1,500                       30
                                                                                                    4
       cooking ranges On or above 90 kHz              Any                 300                         30
       1Field strength may not exceed 10 μV/m at 1600 meters. Consumer equipment operating below 1000

       MHz is not permitted the increase in field strength otherwise permitted here for power over 500 watts.
       2Reduced to the greatest extent possible.
       3Field strength may not exceed 10 μV/m at 1600 meters. Consumer equipment is not permitted the

       increase in field strength otherwise permitted here for over 500 watts.
       4Induction cooking ranges manufactured prior to February 1, 1980, shall be subject to the field

       strength limits for miscellaneous ISM equipment.
  Note 1: Limit 3m(dBμV/m)=Limit 300m(dBμV/m)+40Log(300m/3m) (Below 30MHz)
  Note 2: Limit 3m(dBμV/m)=Limit 300m(dBμV/m)+20Log(300m/3m) (Above 30MHz)
  Note 3: this product is a wireless charger which operated at 90kHz without data transmission. So, it belongs to
  miscellaneous with non-SIM frequency.

  v



EMC_SZ_FR_22.03 FCC                            TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                       Page 15 of 18
                                 Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                      Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01



  Radiated Emission

      Product Type          :   Wireless Quick Charger
      M/N                   :   CP60
      Operating Condition   :   Charging Mode
      Comment               :   30-1000MHz

                                    Emission                                                                            Correct
       Frequency    Frequency                         Polarization          Limit        Detector         Margin                  Result
                                      Level                                                                              factor
         Band
                        MHz          dBμV/m                               dBμV/m                         dBμV/m           (dB)
                       50.006         19.28                  H             63.52             QP           44.24           17.7     Pass
                       62.919         17.51                  H             63.52             QP           46.01           15.8     Pass
                      102.811         20.36                  H             63.52             QP           43.16           16.1     Pass
                      199.750         25.62                  H             63.52             QP           37.90           16.2     Pass
                      436.430         32.41                  H             63.52             QP           31.11           22.5     Pass
         30MHz-       950.045         35.36                  H             63.52             QP           28.16           31.0     Pass
        1000MHz        46.854         28.58                  V             63.52             QP           34.94           18.0     Pass
                       80.501         24.42                  V             63.52             QP           39.10           11.9     Pass
                       99.961         26.29                  V             63.52             QP           37.23           16.4     Pass
                      120.998         25.26                  V             63.52             QP           38.26           14.5     Pass
                      170.711         31.13                  V             63.52             QP           32.39           13.9     Pass
                      196.901         35.09                  V             63.52             QP           28.43           16.2     Pass

  Remark:
     1) Corrector factor = Antenna Factor + Cable Loss
     2) The worst case data were reported and no other spurious and harmonics emissions were reported
        greater than listed emission above table.




  v



EMC_SZ_FR_22.03 FCC                           TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 16 of 18
                                Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                     Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01



      10. Test Equipment List
  Radiated Emission Test
       DESCRIPTION         MANUFACTURER                    MODEL NO.                     SERIAL NO.                 CAL. DUE DATE
      EMI Test Receiver    Rohde & Schwarz                  ESR 26                         101269                      2019-7-6
         Trilog Super
       Broadband Test        Schwarzbeck                    VULB 9163                          707                        2019-7-6
           Antenna
        Horn Antenna       Rohde & Schwarz                    HF907                          102294                       2019-7-6
        Loop Antenna       Rohde & Schwarz                   HFH2-Z2                         100398                       2019-7-6
         Pre-amplifier     Rohde & Schwarz                    SCU 18                       102230                         2019-7-6
       Signal Generator    Rohde & Schwarz                    SMY01                      839369/005                       2019-7-6
          Attenuator           Agilent                        8491A                      MY39264334                       2019-7-6
      3m Semi-anechoic
                                  TDK                          9X6X6                            ----                      2020-7-7
           chamber
        Test software      Rohde & Schwarz                     EMC32                   Version 9.15.00                        N/A

  Conducted Emission Test
        DESCRIPTION        MANUFACTURER                   MODEL NO.                      SERIAL NO.                  CAL. DUE DATE
      EMI Test Receiver     Rohde & Schwarz                 ESR 3                           101782                      2019-7-6
             LISN           Rohde & Schwarz                ENV4200                          100249                      2019-7-6
             LISN           Rohde & Schwarz                ENV432                           101318                      2019-7-6
             LISN           Rohde & Schwarz                ENV216                           100326                      2019-7-6
              ISN           Rohde & Schwarz                 ENY81                           100177                      2019-7-6
              ISN           Rohde & Schwarz               ENY81-CA6                         101664                      2019-7-6
      High Voltage Probe    Rohde & Schwarz             TK9420(VT9420)                     9420-584                    2019-6-30
       RF Current Probe     Rohde & Schwarz                 EZ-17                           100816                     2019-6-30
          Attenuator       Shanghai Huaxiang               TS2-26-3                       080928189                     2019-7-6
         Test software      Rohde & Schwarz                 EMC32                       Version9.15.00                     N/A




  v



EMC_SZ_FR_22.03 FCC                        TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 17 of 18
                             Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                  Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


  Report Number: 68.760.18.0480.01



      11. Measurement System Uncertainty
  For a 95% confidence level, the measurement expanded uncertainties for defined systems, in accordance with
  the recommendations of ISO 17025 were:

                                          System Measurement Uncertainty
                                  Items                                                         Extended Uncertainty
            Uncertainty for Conducted Emission 9kHz-150KHz                                              3.62dB
      Uncertainty for Radiated Emission in 3m chamber 9KHz-30MHz                                        4.46dB
            Uncertainty for Radiated Emission in 3m chamber                                      Horizontal: 4.91dB;
                             30MHz-1000MHz                                                         Vertical: 4.89dB;




  v



EMC_SZ_FR_22.03 FCC                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 18 of 18
                            Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2018-04-27                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2019-06-18 05:05:54
Document Modified: 2019-06-18 05:05:54

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC