FCC Part 15C test report

FCC ID: QISCP60

Test Report

Download: PDF
FCCID_3987644

Report Number: 68.950.18.0336.01




                                                               FCC - TEST REPORT



Report Number                                          : 68.950.18.0336.01                                   Date of Issue:              August 7, 2018


Model                                                  : CP60

Product Type                                           : HUAWEI WIRELESS CHARGER

Applicant                                              : Huawei Technologies Co., Ltd.

Address                                                : Administration Building, Headquarters of Huawei Technologies Co.,

                                                       : Ltd., Bantian, Longgang District, Shenzhen, 518129, P.R.C

Manufacturer                                           : Huawei Technologies Co., Ltd.

Address                                                : Administration Building, Headquarters of Huawei Technologies Co.,

                                                       : Ltd., Bantian, Longgang District, Shenzhen, 518129, P.R.C


Test Result                                            : n Positive                    o Negative



Total pages including
Appendices                                             : 19


TÜV SÜD Certification and Testing (China) Co., Ltd. – Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined
in ISO 17025.


TÜV SÜD Certification and Testing (China) Co., Ltd. – Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction
of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with
identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the
production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. – Shenzhen Branch shall have no
liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. – Shenzhen Branch
issued reports.


This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be
reproduced except in full without our written approval




EMC_SZ_FR_23.03 FCC                                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                               Page 1 of 19
                                           Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



1     Table of Contents
1     Table of Contents ........................................................................................................................................... 2
2     Details about the Test Laboratory ................................................................................................................... 3
3     Description of the Equipment Under Test ........................................................................................................ 4
4     Summary of Test Standards ........................................................................................................................... 5
5     Summary of Test Results ................................................................................................................................ 6
6     General Remarks ........................................................................................................................................... 7
7     Test Setups .................................................................................................................................................... 8
8     Systems test configuration .............................................................................................................................. 9
9     Technical Requirement ................................................................................................................................. 10
    9.1      Conducted Emission Test ..................................................................................................................... 10
    9.2      20 dB Bandwidth and 99% Occupied Bandwidth ................................................................................... 13
    9.3      Radiated Emission Test ........................................................................................................................ 14
10        Test Equipment List .................................................................................................................................. 18
11        System Measurement Uncertainty............................................................................................................. 19




EMC_SZ_FR_23.03 FCC                                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                            Page 2 of 19
                                        Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                             Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



2   Details about the Test Laboratory
Details about the Test Laboratory
Test Site 1

Company name:         TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch
                      Building 12 & 13, Zhiheng Wisdomland Business Park, Nantou Checkpoint
                      Road 2, Nanshan District
                      Shenzhen 518052
                      P.R. China

Telephone:            86 755 8828 6998
Fax:                  86 755 828 5299

FCC Registration      514049
No.:

IC Registration       10320A
No.:




EMC_SZ_FR_23.03 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 3 of 19
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



3   Description of the Equipment Under Test
 Product:                           HUAWEI WIRELESS CHARGER

 Model no.:                         CP60

 FCC ID:                            QISCP60

 Options and accessories:           Adapter and USB Cable

 Rating:                            5-12Vdc 2A Max supplied by an external adapter

 Adapter information:               Manufacturer: Huawei Technologies Co.,Ltd.
                                    Model: HW-100400U00
                                    Input voltage:100-240V 50/60Hz 1.2A
                                    Output voltage:5V     2A or 9V     2A or 10V                                   4A Max

 RF Transmission Frequency:         111-148KHz

 Antenna Type:                      Integrated coil antenna

 Description of the EUT:            The Equipment Under Test (EUT) is a wireless charger which operated
                                    at 111-148kHz.




EMC_SZ_FR_23.03 FCC                      TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 4 of 19
                           Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



4   Summary of Test Standards

                                         Test Standards
FCC Part 15 Subpart C       PART 15 - RADIO FREQUENCY DEVICES
10-1-2017 Edition           Subpart C - Intentional Radiators

All the test methods were according to ANSI C63.10 (2013).




EMC_SZ_FR_23.03 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 5 of 19
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



5     Summary of Test Results
                                             Technical Requirements
 FCC Part 15 Subpart C
                                                                                               Test            Test Result
 Test Condition                                                                 Pages
                                                                                               Site        Pass   Fail     N/A
                                       Conducted emission AC
 §15.207                                                                           10         Site 1
                                       power port

 --                                    20dB bandwidth                              13         Site 1

                                       Restricted bands of
 §15.205                                                                           13         Site 1
                                       operation

 §15.209                               Radiated emission                           14         Site 1

 §15.203                               Antenna requirement                         See note 1


Note 1: The EUT uses an Integrated coil antenna, which gain is 0dBi. In accordance to §15.203, it is
considered sufficiently to comply with the provisions of this section.




EMC_SZ_FR_23.03 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 6 of 19
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



6    General Remarks

Remarks

This submittal(s) (test report) is intended for FCC ID: QISCP60, complies with Section 15.207,
15.209, 15.205 of the FCC Part 15, Subpart C rules.

SUMMARY:

All tests according to the regulations cited on page 5 were

n - Performed

o - Not Performed

The Equipment under Test

n - Fulfills the general approval requirements.

o - Does not fulfill the general approval requirements.



Sample Received Date:                          July 30, 2018

Testing Start Date:                           August 1, 2018

Testing End Date:                             August 2, 2018


- TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch -



Reviewed by:                         Prepared by:                                           Tested by:




    _______________________                _______________________                              _______________________
            John Zhi                                 Alan Xiong                                           Tree Zhan
        Project Manager                           Project Engineer                                       Test Engineer




EMC_SZ_FR_23.03 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 7 of 19
                          Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



7     Test Setups

7.1 Radiated test setups

Below 30MHz




30MHz-1GHz




7.2 Conducted RF test setups
    Measuring                 EUT
    Receiver




EMC_SZ_FR_23.03 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 8 of 19
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



8   Systems test configuration

Auxiliary Equipment Used during Test:

         Description               Manufacturer                           Model NO.                                S/N
         Mobile Phone                HUAWEI                                  ---                                   ---

         Description                    Length                    Shielded/unshielded                 With / without ferrite
         USB Cable                       1.0m                           Shielded                         Without ferrite




EMC_SZ_FR_23.03 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 9 of 19
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



9   Technical Requirement

9.1 Conducted Emission Test

Test Method
   1. The EUT was placed on a table, which is 0.8m above ground plane
   2. The power line of the EUT is connected to the AC mains through an Artificial Mains Network
      (A.M.N.).
   3. Maximum procedure was performed to ensure EUT compliance
   4. A EMI test receiver is used to test the emissions from both sides of AC line

Limit
According to §15.207, conducted emissions limit as below:

                         Frequency                         QP Limit                        AV Limit
                            MHz                             dBμV                            dBμV
                         0.150-0.500                        66-56*                          56-46*
                           0.500-5                            56                              46
                            5-30                              60                              50

*Decreasing linearly with logarithm of the frequency




EMC_SZ_FR_23.03 FCC                     TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 10 of 19
                          Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20               Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



Conducted Emission

Product Type                        :   HUAWEI WIRELESS CHARGER
M/N                                 :   CP60
Operating Condition                 :   Charging Mode
Test Specification                  :   Line
Comment                             :   AC 120V/60Hz


                             80

                             70

                             60
              Level in dB礦




                             50

                             40

                             30

                             20

                             10

                             0
                             150k         300 400 500         800 1M             2M      3M 4M 5M 6             8 10M          20M        30M
                                                                           Frequency in Hz

                                        Frequency        MaxPeak       Average       Limit      Margin     Line     Corr.
                                          (MHz)           (dBµV)       (dBµV)       (dBµV)       (dB)               (dB)
                                           0.166000          53.33           ---      65.16       11.83    L1        10.2
                                           0.282000          47.65           ---      60.76       13.11    L1        10.2
                                           0.678500             ---       26.98       46.00       19.02    L1        10.2
                                           0.678500          38.86           ---      56.00       17.14    L1        10.2
                                           0.730500             ---       24.30       46.00       21.70    L1        10.2
                                           0.730500          34.18           ---      56.00       21.82    L1        10.2
                                           1.290000          44.14           ---      56.00       11.86    L1        10.2
                                           5.510000          42.28           ---      60.00       17.72    L1        10.4

*Correct factor=cable loss + LISN factor




EMC_SZ_FR_23.03 FCC                                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 11 of 19
                                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



Conducted Emission

Product Type                        :   HUAWEI WIRELESS CHARGER
M/N                                 :   CP60
Operating Condition                 :   Charging Mode
Test Specification                  :   Neutral
Comment                             :   AC 120V/60Hz


                             80

                             70

                             60
              Level in dB礦




                             50

                             40

                             30

                             20

                             10

                             0
                             150k         300 400 500         800 1M             2M      3M 4M 5M 6             8 10M          20M        30M
                                                                           Frequency in Hz

                                        Frequency       QuasiPeak       Average        Limit     Margin     Line     Corr.
                                          (MHz)          (dBµV)         (dBµV)        (dBµV)      (dB)               (dB)
                                           0.169500             ---        40.43        54.98      14.55    N         10.3
                                           0.169500          53.48            ---       64.98      11.50    N         10.3
                                           0.229500             ---        34.72        52.47      17.75    N         10.3
                                           0.229500          50.31            ---       62.47      12.16    N         10.3
                                           0.281500             ---        34.73        50.77      16.04    N         10.3
                                           0.281500          48.09            ---       60.77      12.68    N         10.3
                                           0.329500             ---        24.92        49.46      24.54    N         10.3
                                           0.329500          45.13            ---       59.46      14.33    N         10.3
                                           0.658500             ---        25.58        46.00      20.42    N         10.4
                                           0.658500          43.23            ---       56.00      12.77    N         10.4
                                           0.729500             ---        32.79        46.00      13.21    N         10.4
                                           0.729500          43.15            ---       56.00      12.85    N         10.4


*Correct factor=cable loss + LISN factor




EMC_SZ_FR_23.03 FCC                                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 12 of 19
                                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01




9.2 20 dB Bandwidth and 99% Occupied Bandwidth
Test Method
      1. Use the following spectrum analyzer settings:
      RBW=200Hz, VBW≥3RBW, Sweep = auto, Detector function = peak, Trace = max hold
      2. Use the automatic bandwidth measurement capability of an instrument, may be
      employed using the X dB bandwidth mode with X set to 20 dB, care shall be taken so that
      the bandwidth measurement is not influenced by any intermediate power nulls in the
      fundamental emission that might be ≥ 20 dB.
      3. Allow the trace to stabilize, record the X dB Bandwidth value.

Limit

                                                        Limit [kHz]

                                                          No Limit

Test result
                          20dB                    99%
    Frequency                                                                           Result
                        bandwidth               bandwidth                                                                   Result
         KHz               Hz                      Hz                      FL (KHz)                  FH (KHz)
        111KHz            419.7                   448.6                     110.9                        --                 Pass
        148KHz            538.1                   543.2                        --                     148.4                 Pass

The fundamental frequency is outside the restricted bands of 15.205 section.




EMC_SZ_FR_23.03 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 13 of 19
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01




9.3 Radiated Emission Test

Test Method
   1: The EUT was place on a turn table which is 0.8m above ground for below 1GHz at 3
   meters chamber room for test. The table was rotated 360 degrees to determine the position
   of the highest radiation.
   2: The EUT was set 3 meters away from the interference – receiving antenna, which was
   mounted on the top of a variable – height antenna tower.
   3: The height of antenna is varied from one meter to four meters above the ground to
   determine the maximum value of the field strength. Both horizontal and vertical polarizations
   of the antenna are set to make the measurement.
   4: For each suspected emission, the EUT was arranged to its worst case and then the
   antenna was tuned to heights from 1 meter to 4 meters and the rotatable table was turned
   from 0 degrees to 360 degrees to find the maximum reading.
   5: Use the following spectrum analyzer settings According to C63.10:

Limit

the emissions from an intentional radiator shall not exceed the field strength levels specified in
the following table:

     Frequency           Field Strength                 Field Strength                   Detector            Measurement distance
        MHz                  μV/m                          dBμV/m                                                  meters
     0.009-0.490           2400/F(kHz)                     48.5-13.8                         QP                      300
     0.490-1.705          24000/F(kHz)                     33.8-23.0                         QP                       30
      1.705-30                  30                           29.5                            QP                       30
        30-88                  100                            40                             QP                       3
       88-216                  150                           43.5                            QP                       3
       216-960                 200                            46                             QP                       3
      960-1000                 500                            54                             QP                       3
     Above 1000                500                            54                             AV                       3
     Above 1000               5000                            74                             PK                       3

Note 1: Limit 3m(dBμV/m)=Limit 300m(dBμV/m)+40Log(300m/3m) (Below 30MHz)
Note 2: Limit 3m(dBμV/m)=Limit 30m(dBμV/m)+40Log(30m/3m) (Below 30MHz)




EMC_SZ_FR_23.03 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 14 of 19
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



Radiated emissions test (9KHz-30MHz)

                                Emission                                                                            Correct
    Frequency     Frequency                       Polarization           Limit        Detector        Margin                    Result
                                 Level                                                                               factor
      Band
                     MHz        dBμV/m                                 dBμV/m                        dBμV/m           (dB)
                     0.149       56.47                   H              93.8              QP          37.33           19.7       Pass
                     0.150       66.02                   H              93.8              QP          27.78           19.7       Pass
                     0.195       55.21                   H              93.8              QP          38.59           19.7       Pass
                     0.245       53.48                   H              93.8              QP          40.32           19.7       Pass
                     Other
                                      --                 H               93.8             QP              --             --      Pass
      9KHz-       frequency
      30MHz        0.00900         54.62                 V               93.8             QP           39.18          20.8       Pass
                     0.149         57.41                 V               93.8             QP           36.39          19.7       Pass
                     0.150         62.10                 V               93.8             QP           31.7           19.7       Pass
                    0.0240         52.04                 V               93.8             QP           41.76          20.0       Pass
                     Other
                                      --                 V               93.8             QP              --             --      Pass
                  frequency

Remark:
      (1) “*” means the emission(s) appear within the restrict bands shall follow the requirement of section
          15.205.
      (2) Data of measurement within this frequency range shown “--” in the table above means the reading of
          emissions are the noise floor or attenuated more than 20dB below the permissible limits or the field
          strength is too small to be measured.
      (3) Above 1GHz: Corrector factor = Antenna Factor + Cable Loss- Amplifier Gain
          Below 1GHz: Corrector factor = Antenna Factor + Cable Loss
      (4) All tested frequencies comply for the strictest limit (93.8dBμV/m). so the test result can considered as
          Pass.




EMC_SZ_FR_23.03 FCC                       TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 15 of 19
                            Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                 Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01


Radiated emissions test (30MHz-1000MHz)

Product Type                        :   HUAWEI WIRELESS CHARGER
M/N                                 :   CP60
Operating Condition                 :   Quick Charging Mode
Test Specification                  :   Horizontal
Comment                             :   30MHz-1000MHz

                              70

                              60

                              50
             Level in dB礦/m




                              40

                              30


                              20

                              10

                              0
                              30M          50    60       80 100M                    200            300    400    500           800      1G
                                                                          Frequency in Hz

             Frequency                  MaxPeak          Limit          Margin       Height          Pol         Azimuth          Corr.
               (MHz)                    (dBµV/m)       (dBµV/m)          (dB)         (cm)                        (deg)           (dB)
               50.006250                    19.28           40.00          20.72      100.0     H                      9.0           17.7
               62.919375                    17.51           40.00          22.49      100.0     H                      9.0           15.8
              102.810625                    20.36           43.50          23.14      200.0     H                      0.0           16.1
              199.750000                    25.62           43.50          17.88      200.0     H                     69.0           16.2
              436.430000                    32.41           46.00          13.59      100.0     H                    195.0           22.5
              950.045000                    35.36           46.00          10.64      100.0     H                     61.0           31.0

Corrector factor = Antenna Factor + Cable Loss




EMC_SZ_FR_23.03 FCC                                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 16 of 19
                                        Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                             Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01


Product Type                        :   HUAWEI WIRELESS CHARGER
M/N                                 :   CP60
Operating Condition                 :   Quick Charging Mode
Test Specification                  :   Vertical
Comment                             :   30MHz-1000MHz

                              70

                              60

                              50
             Level in dB礦/m




                              40

                              30

                              20

                              10


                              0
                              30M          50    60       80 100M                    200            300    400    500           800      1G
                                                                          Frequency in Hz

             Frequency                  MaxPeak          Limit          Margin       Height          Pol         Azimuth          Corr.
               (MHz)                    (dBµV/m)       (dBµV/m)          (dB)         (cm)                        (deg)           (dB)
               46.853750                    28.58           40.00          11.42      100.0     V                     38.0           18.0
               80.500625                    24.42           40.00          15.58      200.0     V                    227.0           11.9
               99.961250                    26.29           43.50          17.21      100.0     V                    218.0           16.4
              120.998125                    25.26           43.50          18.24      100.0     V                    124.0           14.5
              170.710625                    31.13           43.50          12.37      100.0     V                    109.0           13.9
              196.900625                    35.09           43.50           8.41      100.0     V                    148.0           16.2

Corrector factor = Antenna Factor + Cable Loss




EMC_SZ_FR_23.03 FCC                                   TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                 Page 17 of 19
                                        Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20                             Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01



10 Test Equipment List

                                           List of Test Instruments
Radiated Emission Test
    DESCRIPTION        MANUFACTURER                    MODEL NO.                      SERIAL NO.                 CAL. DUE DATE
   EMI Test Receiver   Rohde & Schwarz                  ESR 26                          101269                      2019-7-6
      Trilog Super
    Broadband Test       Schwarzbeck                    VULB 9163                           707                           2019-7-6
        Antenna
     Horn Antenna      Rohde & Schwarz                     HF907                         102294                           2019-7-6
     Loop Antenna      Rohde & Schwarz                    HFH2-Z2                        100398                           2019-7-6
      Pre-amplifier    Rohde & Schwarz                     SCU 18                      102230                             2019-7-6
    Signal Generator   Rohde & Schwarz                     SMY01                     839369/005                           2019-7-6
       Attenuator          Agilent                         8491A                     MY39264334                           2019-7-6
   3m Semi-anechoic
                               TDK                          9X6X6                           ----                          2020-7-7
        chamber
     Test software     Rohde & Schwarz                     EMC32                    Version 9.15.00                         N/A

Conducted Emission Test
    DESCRIPTION        MANUFACTURER                   MODEL NO.                      SERIAL NO.                  CAL. DUE DATE
  EMI Test Receiver     Rohde & Schwarz                 ESR 3                           101782                      2019-7-6
         LISN           Rohde & Schwarz                ENV4200                          100249                      2019-7-6
         LISN           Rohde & Schwarz                ENV432                           101318                      2019-7-6
         LISN           Rohde & Schwarz                ENV216                           100326                      2019-7-6
          ISN           Rohde & Schwarz                 ENY81                           100177                      2019-7-6
          ISN           Rohde & Schwarz               ENY81-CA6                         101664                      2019-7-6
  High Voltage Probe    Rohde & Schwarz             TK9420(VT9420)                     9420-584                    2019-6-30
   RF Current Probe     Rohde & Schwarz                 EZ-17                           100816                     2019-6-30
      Attenuator       Shanghai Huaxiang               TS2-26-3                       080928189                     2019-7-6
     Test software      Rohde & Schwarz                 EMC32                       Version9.15.00                     N/A




EMC_SZ_FR_23.03 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                  Page 18 of 19
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299


Report Number: 68.950.18.0336.01

11 System Measurement Uncertainty

For a 95% confidence level, the measurement expanded uncertainties for defined systems, in
accordance with the recommendations of ISO 17025 were:

                                       System Measurement Uncertainty
                        Test Items                                                        Extended Uncertainty
  Uncertainty for Conducted Emission 9kHz-150KHz                          3.62dB
  Uncertainty for Radiated Emission in 3m chamber
                                                                          4.46dB
  9KHz-30MHz
  Uncertainty for Radiated Emission in 3m chamber                         Horizontal: 4.91dB;
  30MHz-1000MHz                                                           Vertical: 4.89dB;




EMC_SZ_FR_23.03 FCC                    TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch                Page 19 of 19
                         Building 12&13, Zhiheng W isdomland Business Park, Nantou Checkpoint Road 2, Nanshan District,
Release 2017-06-20              Shenzhen City, 518052, P. R. China Tel. +86 755 8828 6998, Fax: +86 755 8828 5299



Document Created: 2019-06-14 11:13:53
Document Modified: 2019-06-14 11:13:53

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC