MPE

FCC ID: QISCM51

RF Exposure Info

Download: PDF
FCCID_3730168

                                 FCC ID: QISCM51

Portable device
According to §15.247(i) and §1.1307(b)(1), systems operating under the provisions of this section
shall be operated in a manner that ensures that the public is not exposed to radio frequency energy
level in excess of the Commission’s guidelines.
According to KDB447498 D01 General RF Exposure Guidance v06
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances
≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] *
[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
f(GHz) is the RF channel transmit frequency in GHz;
Power and distance are rounded to the nearest mW and mm before calculation;
The result is rounded to one decimal place for comparison;
The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm
and for transmission frequencies between 100 MHz and 6 GHz.
We used a distance 50mm to calculated
Maximum measured transmitter power:

DSS:
                                                                Max
  Transmit                        Measured       Tune-up
                                                              tune-up       Result
 Frequency          Mode           power          power                                   1-g SAR
                                                               power      calculation
   (GHz)                           (dBm)          (dBm)
                                                               (dBm)
    2.402          GFSK             2.094         1 to 3         3            0.62           3.0
    2.441          GFSK             4.260         3 to 5         5            0.99           3.0
    2.480          GFSK             3.910         2 to 4         4            0.79           3.0
    2.402       1/4Π-DQPSK          1.514         0 to 2         2            0.49           3.0
    2.441       1/4Π-DQPSK          3.668         2 to 4         4            0.78           3.0
    2.480       1/4Π-DQPSK          3.302         2 to 4         4            0.79           3.0
    2.402          8DPSK            3.794         2 to 4         4            0.78           3.0
    2.441          8DPSK            5.626         4 to 6         6            1.24           3.0
    2.480          8DPSK            5.367         4 to 6         6            1.25           3.0




Conclusion:
For the max result : 1.25≤ 3.0 for 1-g SAR extremity SAR, No SAR is required.