EHS8 Modular Approval FCC

FCC ID: QIPEHS8

Cover Letter(s)

Download: PDF
FCCID_4197139

                               to*

genial




 Gemalto M2M GmbH    Siemensdamm 50   13629 Berlin. Germany



Federal Communication Commission                                                                Name       Axel Heike
                                                                                           Department      System Test Certifications
Equipment Authorization Division, Application                                                                            -




Processing Branch                                                                               Phone      +493031102-8146
7435 Oakland Mills Road                                                                           Fax      +493031702-8305
Columbia, MD 21048                                                                              E-Mail     AxeI.Heikegemalto.com
USA
                                                                                          Your letter of
                                                                                         Our reference
                                                                                                   Date    28 January2019


                                            Modular Approval Statement
FCC Certification Number: QIPEHS8
                                 47 CFR 15.212 Modular Transmitters           -




   Request for Modular Approval             X   Request for Limited Modular Approval
                    Requirements                           EUT Conditions             Comply (YIN)
                                Single Modular Approval Requirements
    The radio elements of the modular           The modular transmitter has its own
    transmitter must have their own             RE shielding. Please refer to
    shielding. The physical crystal and tuning external photos.                           Y
     capacitors may be located external to the
     shielded radio elements.
    The modular transmitter must have           The module has buffered
     buffered modulation/data inputs (if such   modulation/data inputs to ensure
     inputs are provided) to ensure that the    that the device will comply with Part
 2
     module will comply with part 15            15 requirements with any type of
     requirements under conditions of           input signal.
     excessive data rates or over-modulation.
                                        .       The modular transmitter has its own
                                                                    .

     The modular transmitter must have its
 3                                              power supply regulation. Please
                                                 .                                        Y
     own power supply regulation.
                                                refer to PMD9635 in Schematic.
     The modular transmitter must comply        The requirements of antenna
     with the antenna and transmission          connector and spurious emissions
     system requirements of § 15.203,           have been fulfilled. Please refer to
     15.204(b) and 15.204(c). The antenna       Test Report.
           either be permanently attached or
     must
     employ a “unique” antenna coupler (at all
     connections between the module and the
     antenna, including the cable). The
     “professional installation” provision of §
      15.203 is not applicable to modules but



www.gemalto.comlm2m


Registered Office:                                   Managing Directora:                          commercial register, Reg. No.:
Gemalto M2M GmbH                                     Andreas Hdgele, Sébastien Gallois            Amtsgericht Ménchen, HRB 172715
Werinherstr. 81                                                                                   WEEE-Reg.-Nr. DE 58893809
81541 Munich
Germany


gemal [ox

       can apply to limited modular approvals
       under paragraph (b) of this section.
       The modular transmitter must be tested           The modular transmitter is tested in
       in a stand-alone configuration, i.e., the        a stand-alone configuration. Please
       module must not be inside another                refer to Setup Photo.
       device during testing for compliance with
       part 15 requirements. Unless the
       transmitter module will be battery
       powered, it must comply with the AC line
       conducted requirements found in §
       15.207. AC or DC power lines and data
       input/output lines connected to the
       module must not contain ferrites, unless
  5                                                                                            Y
       they will be marketed with the module
       (see § 15.27(a)). The length of these
       lines shall be the length typical of actual
       use or, if that length is unknown, at least
       10 centimeters to insure that there is no
       coupling between the case of the module
       and supporting equipment. Any
       accessories, peripherals, or support
       equipment connected to the module
       during testing shall be unmodified and
       commercially available (see § 15.31(i)).
       The modular transmitter must be                  The modular transmitter is labelled
       equipped with either a permanently               with its own FCC ID. Labelling
       affixed label or must be capable of              instructions for host devices are
       electronically displaying its FCC                stated in the user manual under
       identification number.                           chapter “Compliance with FCC and
       (A) If using a permanently affixed label, the    IC Rules and Regulations”
       modular transmitter must be labeled with its
       own FCC identification number, and, if the
       FCC identification number is not visible when
       the module is installed inside another device,
       then the outside of the device into which the
  6    module is installed must also display a label                                           Y
       referring to the enclosed module. This
       exterior label can use wording such as the
       following: “Contains Transmitter Module FCC
       ID: XYZMODEL 7” or “Contains FCC ID:
       XYZMODEL7. “Any similar wording that
       expresses the same meaning may be used.
       The Grantee may either provide such a label,
       an example of which must be included in the
       application for equipment authorization, or,
       must provide adequate instructions along
       with the module which explain this



www. gem alto. comlm 2m


                              [ox

gemal




     requirement. In the latter case, a copy of
     these instructions must be included in the
     application for equipment authorization.
     (B) If the modular transmitter uses an
     electronic display of the FCC identification
     number, the information must be readily
     accessible and visible on the modular
     transmitter or on the device in which it is
     installed. If the module is installed inside
     another device, then the outside of the device
     into which the module is installed must
     display a label referring to the enclosed
     module. This exterior label can use wording
     such as the following: “Contains FCC certified
     transmitter module(s). “Any similar wording
     that expresses the same meaning may be
     used. The user manual must include
     instructions on how to access the electronic
     display. A copy of these instructions must be
     included in the application for equipment
     authorization.
     The modular transmitter must comply              The modular transmitter complies
     with any specific rules or operating             with any specific rules or operating
     requirements that ordinarily apply to a          requirements. Instructions are
     complete transmitter and the                     provided in the user manual.
 7   manufacturer must provide adequate                                                       Y
     instructions along with the module to
     explain any such requirements. A copy of
     these instructions must be included in the
     application for equipment authorization.
                                      .               The modular transmitter complies
     The modular transmitter must comply
       .              .                               with RF exposure requirements.
 8   with any applicable RF exposure                                               .          Y
           .              .   .   .       .   .       Please refer to MPE calculation for
     requirements in its final configuration.                       .

                                                      the exposure information.

If you have any questions, please feel free to contact us at the address shown above.

Sincerel/,;




Axel Heike
Certification Managr
                              /                                         Lars Wehmeier
                                                                        Head of System Test