R12902541-E2 v3 FCC IC MPE REPORT

FCC ID: QFS001-10037200L

RF Exposure Info

Download: PDF
FCCID_4420993

         FCC Part 1 Subpart I
         FCC Part 2 Subpart J
          RSS 102 ISSUE 5

        RF EXPOSURE REPORT

                 FOR

          GROUND RADAR

      MODEL NUMBER: GA1360-L

      FCC ID: QFS001-10037200L

    REPORT NUMBER: R12902541-E2

        ISSUE DATE: 2019-08-29

             Prepared for
             DYNETICS
     1002 EXPLORER BOULEVARD
      HUNTSVILLE, AL 35806 USA

             Prepared by
               UL LLC
        12 LABORATORY DR.
RESEARCH TRIANGLE PARK, NC 27709 USA
         TEL: (919) 549-1400




        NVLAP LAB CODE 200246-0


REPORT NO: R12902541-E2                                                                   DATE: 2019-08-29
FCC ID: QFS001-10037200L

                                             Revision History

            Issue
 Ver.       Date               Revisions                                               Revised By
   1        2019-08-22         Initial Issue                                           Richard Jankovics
                               Revised max output power and operating
   2        2019-08-27                                                                 Richard Jankovics
                               frequency
                               Revised operating frequency and separation
   3        2019-08-29                                                                 Richard Jankovics
                               distance




                                                  Page 2 of 9
UL LLC                                                                               FORM NO: 03-EM-F00858
12 Laboratory Dr., RTP, NC 27709                                                          TEL: (919) 549-1400
This report shall not be reproduced except in full, without the written approval of UL LLC.


REPORT NO: R12902541-E2                                                                                          DATE: 2019-08-29
FCC ID: QFS001-10037200L

                                              TABLE OF CONTENTS
1.     ATTESTATION OF TEST RESULTS ................................................................................. 4

2.     TEST METHODOLOGY ..................................................................................................... 5

3.     REFERENCES ................................................................................................................... 5

4.     FACILITIES AND ACCREDITATION ................................................................................. 5

5.     DEVICE UNDER TEST ....................................................................................................... 5

6.     MAXIMUM PERMISSIBLE EXPOSURE (LIMITS AND EQUATIONS) ............................... 6
     6.1.    FCC RULES ................................................................................................................ 6
     6.2.    ISED RULES ............................................................................................................... 7
     6.3.    EQUATIONS................................................................................................................ 8

7.     RF EXPOSURE RESULTS ................................................................................................. 9




                                                  Page 3 of 9
UL LLC                                                                               FORM NO: 03-EM-F00858
12 Laboratory Dr., RTP, NC 27709                                                          TEL: (919) 549-1400
This report shall not be reproduced except in full, without the written approval of UL LLC.


REPORT NO: R12902541-E2                                                                   DATE: 2019-08-29
FCC ID: QFS001-10037200L


1. ATTESTATION OF TEST RESULTS
COMPANY NAME:                    Dynetics
                                 1002 Explorer Boulevard
                                 Huntsville, AL 35806-2806

EUT DESCRIPTION:                 Ground Radar

MODEL:                           GA1360-L


                                      APPLICABLE STANDARDS
                            STANDARD                                           TEST RESULTS
          FCC PART 1 SUBPART I & PART 2 SUBPART J                                  Complies
                         RSS 102 ISSUE 5                                           Complies


UL LLC. tested the above equipment in accordance with the requirements set forth in the above
standards. The test results show that the equipment tested is capable of demonstrating
compliance with the requirements as documented in this report.

The results documented in this report apply only to the tested sample, under the conditions and
modes of operation as described herein. It is the manufacturer's responsibility to assure that
additional production units of this model are manufactured with identical electrical and
mechanical components. All samples tested were in good operating condition throughout the
entire test program. Measurement Uncertainties are published for informational purposes only
and were not taken into account unless noted otherwise.

This document may not be altered or revised in any way unless done so by UL LLC. and all
revisions are duly noted in the revisions section. Any alteration of this document not carried out
by UL LLC. will constitute fraud and shall nullify the document. This report must not be used by
the client to claim product certification, approval, or endorsement by NVLAP, NIST, any agency
of the Federal Government, or any agency of the U.S. government.

Approved & Released For
UL LLC. By:                                                Prepared By:




Jeff Moser                                                Richard Jankovics
Operations Leader                                         Operations Leader
CONSUMER TECHNOLOGY DIVISION                              CONSUMER TECHNOLOGY DIVISION
UL LLC.                                                   UL LLC.




                                                  Page 4 of 9
UL LLC                                                                               FORM NO: 03-EM-F00858
12 Laboratory Dr., RTP, NC 27709                                                          TEL: (919) 549-1400
This report shall not be reproduced except in full, without the written approval of UL LLC.


REPORT NO: R12902541-E2                                                                   DATE: 2019-08-29
FCC ID: QFS001-10037200L


2. TEST METHODOLOGY
All calculations were made in accordance with FCC Parts 1.1310, 2.1091, KDB 447498 D01
v06, IEEE Std C95.1-2005, IEEE Std C95.3-2002, IC Safety Code 6 and RSS 102 Issue 5.


3. REFERENCES
All measurements were made as documented in test report UL LLC R12902541-E1 for
operation in the 3 GHz band.

Output power, Duty cycle and Antenna gain data is excerpted from the applicable test reports
and product documentation provided by the applicant.


4. FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 12 Laboratory Dr.,
Research Triangle Park, NC 27709, USA and 2800 Perimeter Park Dr., Suite B, Morrisville, NC
27560, USA.

UL LLC (RTP) is accredited by NVLAP, Laboratory Code 200246-0.


5. DEVICE UNDER TEST

The EUT is a wide-band ground radar used to monitor a specific area.

Other details regarding the EUT are documented in the applicable test reports and product
documentation.




                                                  Page 5 of 9
UL LLC                                                                               FORM NO: 03-EM-F00858
12 Laboratory Dr., RTP, NC 27709                                                          TEL: (919) 549-1400
This report shall not be reproduced except in full, without the written approval of UL LLC.


REPORT NO: R12902541-E2                                                                   DATE: 2019-08-29
FCC ID: QFS001-10037200L

6. MAXIMUM PERMISSIBLE EXPOSURE (LIMITS AND EQUATIONS)
    6.1.        FCC RULES
§1.1310 The criteria listed in Table 1 shall be used to evaluate the environmental impact of
human exposure to radio-frequency (RF) radiation as specified in §1.1307(b), except in the case
of portable devices which shall be evaluated according to the provisions of §2.1093 of this
chapter.

                         TABLE 1—LIMITS FOR M AXIMUM PERMISSIBLE EXPOSURE (MPE)


Frequency range Electric field strength Magnetic field strength Power density Averaging time
     (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                           (A) Limits for Occupational/Controlled Exposure
0.3-3.0                                  614                        1.63             *100                  6
3.0-30                                 1842/f                      4.89/f          *900/f2                 6
30-300                                   61.4                      0.163               1.0                 6
300-1,500                                                                            f/300                 6
1,500-100,000                                                                            5                 6
                       (B) Limits for General Population/Uncontrolled Exposure
0.3-1.34                                 614                        1.63             *100                 30
1.34-30                                 824/f                      2.19/f          *180/f2                30
30-300                                   27.5                      0.073               0.2                30
300-1,500                                                                           f/1500                30
1,500-100,000                                                                          1.0                30

f = frequency in MHz

* = Plane-wave equivalent power density

Notes:

    (1) Occupational/controlled exposure limits apply in situations in which persons are exposed
        as a consequence of their employment provided those persons are fully aware of the
        potential for exposure and can exercise control over their exposure. Limits for
        occupational/controlled exposure also apply in situations when a person is transient
        through a location where occupational/controlled limits apply provided he or she is made
        aware of the potential for exposure.

    (2) General population/uncontrolled exposure limits apply in situations in which the general
        public may be exposed, or in which persons who are exposed as a consequence of their
        employment may not be fully aware of the potential for exposure or cannot exercise
        control over their exposure



                                                  Page 6 of 9
UL LLC                                                                               FORM NO: 03-EM-F00858
12 Laboratory Dr., RTP, NC 27709                                                          TEL: (919) 549-1400
This report shall not be reproduced except in full, without the written approval of UL LLC.


REPORT NO: R12902541-E2                                                                   DATE: 2019-08-29
FCC ID: QFS001-10037200L

    6.2.        ISED RULES

For the purpose of this standard, Innovation, Science and Economic Development (ISED)
has adopted the SAR and RF field strength limits established in Health Canada’s RF
exposure guideline, Safety Code 6.




                                                  Page 7 of 9
UL LLC                                                                               FORM NO: 03-EM-F00858
12 Laboratory Dr., RTP, NC 27709                                                          TEL: (919) 549-1400
This report shall not be reproduced except in full, without the written approval of UL LLC.


REPORT NO: R12902541-E2                                                                   DATE: 2019-08-29
FCC ID: QFS001-10037200L

    6.3.        EQUATIONS
POWER DENSITY

Power density is given by:

S = EIRP / (4 * Pi * D^2)

Where

S = Power density in mW/cm^2
EIRP = Equivalent Isotropic Radiated Power in mW
D = Separation distance in cm

Power density in units of mW/cm^2 is converted to units of W/m^2 by multiplying by 10.


DISTANCE

Distance is given by:

D = SQRT (EIRP / (4 * Pi * S))

Where

D = Separation distance in cm
EIRP = Equivalent Isotropic Radiated Power in mW
S = Power density in mW/cm^2


SOURCE-BASED DUTY CYCLE

Where applicable (for example, multi-slot cell phone applications) a duty cycle factor may be
applied.

Source-based time-averaged EIRP = (DC / 100) * EIRP

Where

DC = Duty Cycle in %, as applicable
EIRP = Equivalent Isotropic Radiated Power in mW




                                                  Page 8 of 9
UL LLC                                                                               FORM NO: 03-EM-F00858
12 Laboratory Dr., RTP, NC 27709                                                          TEL: (919) 549-1400
This report shall not be reproduced except in full, without the written approval of UL LLC.


REPORT NO: R12902541-E2                                                                    DATE: 2019-08-29
FCC ID: QFS001-10037200L

7.     RF EXPOSURE RESULTS
In the table below, Power and Gain are entered in units of dBm and dBi respectively and
conversions to linear forms are used for the calculations.


Single Chain and non-colocated transmitters
  Band       Mode      Separ. Output Ant. Duty             EIRP      FCC PD      ISED PD        FCC        ISED
                      Distance AVG Gain Cycle                                                 PD Limit    PD Limit
                                 Power
                        (cm)      (dBm) (dBi) (%)          (mW) (mW/cm^2) (W/m^2) (mW/cm^2) (W/m^2)

  3 GHz       1,2,3       100      29.00    3.00 100.0 1584.89         0.01         0.13        1.00            6.26



Notes:

     1) For MPE the new KDB 447498 requires the calculations to use the maximum rated
        power; that power should be declared by the manufacturer and should not be lower than
        the measured power.

     2) The manufacturer configures output power so that the maximum power, after accounting
        for manufacturing tolerances, will never exceed the maximum power level measured.

     3) Using the lowest operating frequency (3023.4375 MHz) in equations, as this would
        represent the lowest limit. Duty cycle assumed to be 100% as worst case.

     4) The antenna gain in the tables above is the maximum antenna gain.


Conclusion:

The computed power density values are less than the corresponding limits at a worse case
separation distance of 100 cm per the product manual; therefore, the device is compliant with the RF
exposure limits.




                                    END OF TEST REPORT




                                                  Page 9 of 9
UL LLC                                                                               FORM NO: 03-EM-F00858
12 Laboratory Dr., RTP, NC 27709                                                          TEL: (919) 549-1400
This report shall not be reproduced except in full, without the written approval of UL LLC.



Document Created: 2019-08-29 09:41:45
Document Modified: 2019-08-29 09:41:45