SAR Test Report

FCC ID: QDMPPF31

RF Exposure Info

Download: PDF
FCCID_3411187

                                                                                                   wwwad ocugrcom
                            TEST REPORT




                                                                                                           y am
                   KCTL Inc.                                  Report No.:
              65, Sinwon—ro, Yeongtong—gu,
          Suwon—si, Gyeonggi—do, 16677, Korea
                                                            KR17—SPFOOO03
      Tel: 82—31—285—0894    Fax: 82—505—299—8311            Page (1) of (51)
                      www.kctl.co.kr

  1. Client

      > Name                     : IRIVER LIMITED
      > Address                  : Iriverhouse, 5, Bangbae—ro 18—gil, Seocho—gu, Seoul, Korea

      > Date of Receipt          : 2017—03—27
  2. Name of Product and Model                      : SP1000 / PPF31



     Variant Model                                  1 —

  3. Manufacturer and Country of Origin : IRIVER LIMITED / Korea

  4. Date of Test                : 2017—04—24

  5. FCC ID                      : QBDMPPES1
  6. FCC Rule Part               : CFR §2.1093
  7. Test method used            : IEEE 1528—2013, ANSI/IEEE C95.1, KDB Publication


  8. Test Results                : Refer to the test result in the test report


                 [Tested by                                    Technical Manager

   Affirmation                         —bavfir/
                  Name : Kyounghoo, Min (Signature)            Name : Cheonsig, Choi      (Signature)




                                                                                           2017—05—15



                                             KCTL Inc.
    As a test result of the sample which was submitted from the client, this report does not guarantee
    the whole product quality. This test report should not be used and copied without a written agreement
    by KCTL Inc.




KCTL—TI1A0O02—004/1


                   KCTL Inc.                                 Report No.:
               65, Sinwon-ro, Yeongtong-gu,
           Suwon-si, Gyeonggi-do, 16677, Korea              KR17-SPF0003
      Tel : 82-31-285-0894 Fax : 82-505-299-8311             Page (2) of (51)
                      www.kctl.co.kr




REPORT REVISION HISTORY

         Date                                         Revision                                    Page No
     2017-05-15                                  Originally issued                                    -




This report shall not be reproduced except in full, without the written approval of KCTL Inc. This document
may be altered or revised by KCTL Inc. personnel only, and shall be noted in the revision section of the
document. Any alteration of this document not carried out by KCTL Inc. will constitute fraud and shall nullify
the document.




 KCTL-TIA002-004/1


                          KCTL Inc.                                            Report No.:
                 65, Sinwon-ro, Yeongtong-gu,
             Suwon-si, Gyeonggi-do, 16677, Korea                              KR17-SPF0003
        Tel : 82-31-285-0894 Fax : 82-505-299-8311                              Page (3) of (51)
                        www.kctl.co.kr




                                                          Contents
1. Client information..........................................................................................................................4
2. Laboratory information ..................................................................................................................5
3. Identification of Sample ................................................................................................................6
4. Test Result Summary....................................................................................................................8
5. Report Overview ...........................................................................................................................8
6. Test Lab Declaration or Comments ...............................................................................................8
7. Applicant Declaration or Comments..............................................................................................8
8. Measurement Uncertainty .............................................................................................................9
9. The SAR Measurement System .................................................................................................10
10. System Verification ...................................................................................................................14
11. Operation Configurations ..........................................................................................................16
12. SAR Measurement Procedures ................................................................................................17
13. Test Equipment Information ......................................................................................................19
14. RF Average Conducted Output Power ......................................................................................20
15. SAR Test Exclusions Applied ....................................................................................................22
16. SAR Test Results ......................................................................................................................23
17. Test System Verification Results ...............................................................................................24
18. Test Results ..............................................................................................................................25
Appendix A. Calibration certificate ..................................................................................................26
Appendix B. EUT Photo ..................................................................................................................45
Appendix C. Test Photo ..................................................................................................................48




                    This test report shall not be reproduced, except in full, without the written approval.
 KCTL-TIA002-004/1


                   KCTL Inc.                                   Report No.:
                65, Sinwon-ro, Yeongtong-gu,
            Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
       Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (4) of (51)
                       www.kctl.co.kr




1. Client information
Client:                       IRIVER LIMITED

Address:                      Iriverhouse, 5, Bangbae-ro 18-gil, Seocho-gu, Seoul, Korea

Telephone:                    82-2-3019-7514

Fax:                          82-2-3019-7575

E-mail:                       dabin.wang@iriver.com

Contact name:                 Dabin, Wang



Manufacturer:                 IRIVER LIMITED

Address:                      Iriverhouse, 5, Bangbae-ro 18-gil, Seocho-gu, Seoul, Korea




               This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                  KCTL Inc.                                   Report No.:
              65, Sinwon-ro, Yeongtong-gu,
          Suwon-si, Gyeonggi-do, 16677, Korea                KR17-SPF0003
     Tel : 82-31-285-0894 Fax : 82-505-299-8311                Page (5) of (51)
                     www.kctl.co.kr




2. Laboratory information
Address
KCTL Inc.

65, Sinwon-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, Korea

TEL: 82-31-285-0894          FAX: 82-505-299-8311



Certificate
KOLAS No.: KT231
FCC Site Designation No.: KR0040
FCC Site Registration No.: 687132
VCCI Site Registration No.: R-3327, G-198, C-3706, T-1849
IC Site Registration No.: 8035A-2


SITE MAP




   Suwon-si




                                               KCTL Inc.




              This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                  KCTL Inc.                                   Report No.:
             65, Sinwon-ro, Yeongtong-gu,
         Suwon-si, Gyeonggi-do, 16677, Korea                 KR17-SPF0003
    Tel : 82-31-285-0894 Fax : 82-505-299-8311                 Page (6) of (51)
                    www.kctl.co.kr




3. Identification of Sample

EUT Type                    SP1000


Brand Name                  IRIVER LIMITED


Mode of Operation           WLAN 802.11b/g/n, Bluetooth


Model Number                PPF31


Serial Number               N/A


Max. Power                  15.50 dBm


Tx Freq.Range               2 412 ~ 2 462 MHz


Rx Freq.Range               2 412 ~ 2 462 MHz


Antenna Type                PCB Type


Antenna Size                9.7 mm x 5.8 mm


Normal Voltage              DC 3.8 V


H/W Version                 1.0


S/W Version                 1.0




              This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                KCTL Inc.                                   Report No.:
             65, Sinwon-ro, Yeongtong-gu,
         Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
    Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (7) of (51)
                    www.kctl.co.kr


3.1 Antenna Diagram



 Front View




            This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                      KCTL Inc.                                   Report No.:
                 65, Sinwon-ro, Yeongtong-gu,
             Suwon-si, Gyeonggi-do, 16677, Korea                 KR17-SPF0003
        Tel : 82-31-285-0894 Fax : 82-505-299-8311                 Page (8) of (51)
                        www.kctl.co.kr




 4. Test Result Summary
 4.1 Body SAR
    Frequency                      Max.
                    Average                                               Separation      Measured          Scaled
                                  tune up       Scaling        EUT
                     Power                                                 Distance        1 g SAR          1 g SAR
    MHz     Ch.                   power         Factor       Position
                     (dBm)                                                   (mm)           (W/kg)          (W/kg)
                                  (dBm)
   2 462     11      12.58         14.50         1.556         Rear             5            0.093           0.145
 * Contain the results of the worst test SAR including battery.



 5. Report Overview
This report details the results of testing carried out on the samples listed in section 3, the
results contained in this test report do not relate to other samples of the same product. The
manufacturer should ensure that all products in series production are in conformity with the
product sample detailed in this report.
This report may only be reproduced and distributed in full. If the product in this test report is
used in any configuration other than that detailed in the test report, the manufacturer must
ensure the new configuration complies with all relevant standards and certification
requirements. Any mention of KCTL Inc. Wireless lab or testing done by KCTL Inc. Wireless
lab made in connection with the distribution or use of the tested product must be approved
in writing by KCTL Inc. Wireless lab.


 6. Test Lab Declaration or Comments
 None



 7. Applicant Declaration or Comments
 None




                  This test report shall not be reproduced, except in full, without the written approval.
  KCTL-TIA002-004/1


                     KCTL Inc.                                   Report No.:
                65, Sinwon-ro, Yeongtong-gu,
            Suwon-si, Gyeonggi-do, 16677, Korea                 KR17-SPF0003
       Tel : 82-31-285-0894 Fax : 82-505-299-8311                 Page (9) of (51)
                       www.kctl.co.kr




8. Measurement Uncertainty
All measurements and results are recorded and maintained at the laboratory performing the tests
and measurement uncertainties are taken into account when comparing measurements to pass/
fail criteria.
Uncertainty of SAR equipments for measurement 300 MHz to 3 GHz (Body)




                 This test report shall not be reproduced, except in full, without the written approval.
 KCTL-TIA002-004/1


                KCTL Inc.                                   Report No.:
             65, Sinwon-ro, Yeongtong-gu,
         Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
    Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (10) of (51)
                    www.kctl.co.kr




9. The SAR Measurement System




                                    <SAR System Configuration>
      A standard high precision 6-axis robot with controller, teach pendant and software. An arm
       extension for accommodating the data acquisition electronics (DAE).
      An isotropic Field probe optimized and calibrated for the targeted measurement.
      Data acquisition electronics (DAE) which performs the signal amplification, signal multiplexing, AD-
       conversion, offset measurements, mechanical surface detection, collision detection, etc. The unit is
       battery powered with standard or rechargeable batteries. The signal is optically transmitted to the
       EOC.
      The Electro-optical converter (EOC) performs the conversion from optical to electrical signals for
       the digital communication to the DAE. To use optical surface detection, a special version of the
       EOC is required. The EOC signal is transmitted to the measurement server.
      The function of the measurement server is to perform the time critical tasks such as signal filtering,
       control of the robot operation and fast movement interrupts.
      The Light Beam used is for probe alignment. This improves the (absolute) accuracy of the probe
       positioning.
      A computer running WinXP or Win7 and the DASY5 software.
      Remote control and teach pendant as well as additional circuitry for robot safety such as warning
       lamps, etc.
      The phantom, the device holder and other accessories according to the targeted measurement.




            This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                KCTL Inc.                                   Report No.:
             65, Sinwon-ro, Yeongtong-gu,
         Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
    Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (11) of (51)
                    www.kctl.co.kr


9.1 Isotropic E-field Probe




            This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                KCTL Inc.                                   Report No.:
             65, Sinwon-ro, Yeongtong-gu,
         Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
    Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (12) of (51)
                    www.kctl.co.kr


9.2 Phantom




            This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                KCTL Inc.                                   Report No.:
             65, Sinwon-ro, Yeongtong-gu,
         Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
    Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (13) of (51)
                    www.kctl.co.kr


9.3 Device Holder for Transmitters




            This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                 KCTL Inc.                                   Report No.:
              65, Sinwon-ro, Yeongtong-gu,
          Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
     Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (14) of (51)
                     www.kctl.co.kr




10. System Verification
10.1 Tissue Verification
The dielectric properties for this Tissue Simulant Liquids were measured by using the
SPEAG Model DAK3.5 Dielectric Probe in conjunction with Agilent E5071B Network
Analyzer (300 kHz – 8 500 MHz). The Conductivity (σ) and Permittivity (ρ) are listed in
Table 1.For the SAR measurement given in this report. The temperature variation of the
Tissue Simulant Liquids was (22 ± 2) °C.
     Freq.   Tissue                                                                                    Temp
                           Limit/Measured            Permittivity (ρ)        Conductivity (σ)
    (MHz)     Type                                                                                      (℃)
                                                       52.75 ± 5 %                1.91 ± 5 %
                        Recommended Limit                                                              22 ± 2
    2 412     MSL                                    (50.11 ~ 55.39)           (1.81 ~ 2.01)
                       Measured, 2017-04-24               50.81                     1.96               21.01
                                                       52.72 ± 5 %                1.94 ± 5 %
                        Recommended Limit                                                              22 ± 2
    2 437     MSL                                    (50.08 ~ 55.36)           (1.83 ~ 2.03)
                       Measured, 2017-04-24               50.92                     1.99               21.01
                                                       52.70 ± 5 %                1.95 ± 5 %
                        Recommended Limit                                                              22 ± 2
    2 450     MSL                                    (50.07 ~ 55.34)           (1.85 ~ 2.05)
                       Measured, 2017-04-24               50.94                     1.98               21.01
                                                       52.69 ± 5 %                1.97 ± 5 %
                        Recommended Limit                                                              22 ± 2
    2 462     MSL                                    (50.06 ~ 55.32)           (1.87 ~ 2.07)
                       Measured, 2017-04-24               50.91                     1.98               21.01
                   <Table 1.Measurement result of Tissue electric parameters>




             This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                            KCTL Inc.                                   Report No.:
                      65, Sinwon-ro, Yeongtong-gu,
                  Suwon-si, Gyeonggi-do, 16677, Korea                  KR17-SPF0003
             Tel : 82-31-285-0894 Fax : 82-505-299-8311                  Page (15) of (51)
                             www.kctl.co.kr


     10.2 Test System Verification

     The microwave circuit arrangement for system verification is sketched below picture.
     The daily system accuracy verification occurs within the flat section of the SAM pha
     ntom. A SAR measurement was performed to see if the measured SAR was within
     ± 10% from the target SAR values. The tests were conducted on the samedays as
     the measurement of the EUT. The obtained results from the system accuracy verific
     ation are displayed in the Table 2. During the tests, the ambient temperature of the

         laboratory was in the range (22 ± 2) ℃, the relative humidity was in the range(50

     ± 20)% and the liquid depth Above the ear/grid reference points was above 15 cm i
     n all the cases. It is seen that the system is operating within its specification, as th
     e results are within acceptable tolerance of the reference values.




Validation    Dipole Ant.       Frequency       Tissue                    Limit/Measurement (Normalized to 1 W)

   Kit            S/N             (MHz)          Type                                                        1 g

                                                             Recommended Limit                          50.80 ± 10 %
D2450V2           895             2 450          MSL              (Normalized)                         (45.72 ~ 55.88)
                                                            Measured, 2017-04-24                            51.60
                                            <Table 2.Test System Verification Result>




                        This test report shall not be reproduced, except in full, without the written approval.
         KCTL-TIA002-004/1


                KCTL Inc.                                   Report No.:
             65, Sinwon-ro, Yeongtong-gu,
         Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
    Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (16) of (51)
                    www.kctl.co.kr




11. Operation Configurations

Measurements were performed at the lowest, middle and highest channels of the
operating band. The EUT was set to maximum power level during all tests and at the
beginning of each test the battery was fully charged.




            This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                  KCTL Inc.                                   Report No.:
              65, Sinwon-ro, Yeongtong-gu,
          Suwon-si, Gyeonggi-do, 16677, Korea                KR17-SPF0003
     Tel : 82-31-285-0894 Fax : 82-505-299-8311                Page (17) of (51)
                     www.kctl.co.kr




12. SAR Measurement Procedures

Step 1: Power Reference Measurement
The Power Reference Measurement and Power Drift Measurements are for monitoring the power
drift ofthe device under test in the batch process. The Minimum distance of probe sensors to
surfacedetermines the closest measurement point to phantom surface. The minimum distance of
probe sensorsto surface is 2 mm. This distance cannot be smaller than the Distance of sensor
calibration points toprobe tip as defined in the probe properties.

Step 2: Area Scan
The Area Scan is used as a fast scan in two dimensions to find the area of high field values, before
doinga fine measurement around the hot spot. The sophisticated interpolation routines
implemented in DASYsoftware can find the maximum locations even in relatively coarse grids.
When an Area Scan hasmeasured all reachable points, it computes the field maximal found in the
scanned area, within a rangeof the global maximum. The range (in dB) is specified in the standards
for compliance testing. Forexample, a 2 dB range is required in IEEE Standard 1528 and IEC
62209 standards, whereby 3 dB is arequirement when compliance is assessed in accordance with
the ARIB standard (Japan). If only oneZoom Scan follows the Area Scan, then only the absolute
maximum will be taken as reference. Forcases where multiple maximums are detected, the number
of Zoom Scans has to be increasedaccordingly.

Area Scan Parameters extracted from KDB 865664 D01 SAR Measument 100 MHz to 6 GHz
v01r04.




              This test report shall not be reproduced, except in full, without the written approval.
 KCTL-TIA002-004/1


                        KCTL Inc.                                      Report No.:
                 65, Sinwon-ro, Yeongtong-gu,
             Suwon-si, Gyeonggi-do, 16677, Korea                      KR17-SPF0003
        Tel : 82-31-285-0894 Fax : 82-505-299-8311                      Page (18) of (51)
                        www.kctl.co.kr


Step 3: Zoom Scan
Zoom Scans are used to assess the peak spatial SAR values within a cubic averaging volume
containing1 g and 10 g of simulated tissue. The Zoom Scan measures 5x5x7 points within a cube
whose base faces are centered on the maxima found in a preceding area scanjob within the same
procedure. When the measurement is done, the Zoom Scan evaluates theaveraged SAR for 1 g
and 10 g and displays these values next to the job’s label.

Zoom Scan Parameters extracted from KDB 865664 D01 SAR Measument 100 MHz to 6 GHz
v01r04.
                                                                        ≤ 3 GHz                       > 3 GHz
Maximum distance from closest measurement point
                                                                     5 mm ± 1 mm               ½· δ·ln(2) mm 0.5 mm
(geometric center of probe sensors) to phantom surface
Maximum probe angle from probe axis to phantom
                                                                        30° ± 1°                      20° ± 1°
surface normal at the measurement location
                                                                    ≤ 2 GHz: ≤ 15 mm             3 – 4 GHz: ≤ 12 mm
                                                                   2 – 3 GHz: ≤ 12 mm            4 – 6 GHz: ≤ 10 mm
                                                               When the x or y dimension of the test device, in the
   Maximum area scan spatial resolution: ΔxArea, ΔyArea        measurement plane orientation, is smaller than the
                                                               above, the measurement resolution must be ≤ the
                                                               corresponding x or y dimension of the test device with
                                                               at least one measurement point on the test device.
                                                                     ≤ 2 GHz: ≤ 8 mm             3 – 4 GHz: ≤ 5 mm*
 Maximum zoom scan spatial resolution: ΔxZoom, ΔyZoom
                                                                   2 – 3 GHz: ≤ 5 mm*            4 – 6 GHz: ≤ 4 mm*
                                                                                                  3 – 4 GHz: ≤ 4 mm
                               uniform grid: ΔzZoom(n)                    ≤ 5 mm                  4 – 5 GHz: ≤ 3 mm
                                                                                                  5 – 6 GHz: ≤ 2 mm
Maximum zoom
                                      ΔzZoom(1): between                                          3 – 4 GHz: ≤ 3 mm
scan spatial
                                      1st two points closest              ≤ 4 mm                 4 – 5 GHz: ≤ 2.5 mm
resolution, normal to
                          graded        to phantom surface                                        5 – 6 GHz: ≤ 2 mm
phantom surface
                          grid        ΔzZoom(n>1):
                                      between subsequent                        ≤ 1.5·ΔzZoom(n-1) mm
                                      points
                                                                                                   3 – 4 GHz: ≥ 28 mm
Minimum zoom
                                        x, y, z                         ≥ 30 mm                    4 – 5 GHz: ≥ 25 mm
    scan volume
                                                                                                   5 – 6 GHz: ≥ 22 mm
Note: δ is the penetration depth of a plane-wave at normal incidence to the tissue medium; see IEEE Std
       1528-2013 for details.
* When zoom scan is required and the reported SAR from the area scan based 1-g SAR estimation procedures of
  KDB Publication 447498 is ≤ 1.4 W/kg, ≤ 8 mm, ≤ 7 mm and ≤ 5 mm zoom scan resolution may be applied,
  respectively, for 2 GHz to 3 GHz, 3 GHz to 4 GHz and 4 GHz to 6 GHz.

Step 4: Power drift measurement
The Power Drift Measurement measures the field at the same location as the most recent
powerreference measurement within the same procedure, and with the same settings. The Power
DriftMeasurement gives the field difference in dB from the reading conducted within the last
PowerReference Measurement. This allows a user to monitor the power drift of the device under
test within abatch process. The measurement procedure is the same as Step 1.

Step 5: Z-Scan
The Z Scan measures points along a vertical straight line. The line runs along the Z-axis of a
onedimensionalgrid. In order to get a reasonable extrapolation, the extrapolated distance should
not belarger than the step size in Z-direction.


* Z Scan Report on Liquid Measure the height Appendix C. Liquid Depth photo to replace



                   This test report shall not be reproduced, except in full, without the written approval.
 KCTL-TIA002-004/1


                       KCTL Inc.                                  Report No.:
                   65, Sinwon-ro, Yeongtong-gu,
               Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
          Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (19) of (51)
                          www.kctl.co.kr




 13. Test Equipment Information
Test Platform                  SPEAG DASY5 System
                               DASY5 : Version 52.8.8.1222
Version
                               SEMCAD : Version 14.6.10 (7331)
Location                       KCTL Inc.
Manufacture                    SPEAG
Hardware Reference
                                                                                    Date of             Due date of
Equipment                      Model                         Serial Number
                                                                                    Calibration         next Calibration
Shield Room                    Shield Room                   None                   N/A                 N/A
DASY5 Robot                    TX90XL Speag                  F12/5L7FA1/A/01        N/A                 N/A
DASY5 Controller               TX90XL Speag                  F12/5L7FA1/C/01        N/A                 N/A
Phantom                        Twin SAM Phantom              1728                   N/A                 N/A
Mounting Device                Mounting Device               None                   N/A                 N/A
DAE                            DAE4                          1342                   2016-07-26          2017-07-26
Probe                          EX3DV4                        3928                   2017-01-31          2018-01-31
Signal Generator               E4438C                        MY42080486             2017-01-06          2018-01-06
Dual Power Meter               E4419B                        GB43312301             2016-07-12          2017-07-12
Power Sensor                   8481H                         3318A19377             2016-07-20          2017-07-20
Power Sensor                   8481H                         3318A19379             2016-07-20          2017-07-20
Power Amplifier                2055 BBS3Q7E9I                1005D/C0521            2016-05-18          2017-05-18
Dual Directional Coupler       772D                          2839A00719             2016-07-12          2017-07-12
Low Pass Filter                LA-30N                        36543                  2016-07-14          2017-07-14
Dipole Validation Kits         D2450V2                       895                    2016-07-25          2018-07-25
Network Analyzer               E5071B                        MY42403524             2017-01-06          2018-01-06
Dielectric Assessment kit      DAK-3.5                       1078                   2016-08-25          2017-08-25
Humidity/Temp. Data Recorder   MHB-382SD                     73871                  2016-07-15          2017-07-15




                  This test report shall not be reproduced, except in full, without the written approval.
  KCTL-TIA002-004/1


                 KCTL Inc.                                  Report No.:
             65, Sinwon-ro, Yeongtong-gu,
         Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
    Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (20) of (51)
                    www.kctl.co.kr




14. RF Average Conducted Output Power
14.1 WLAN 2.4 GHz
                                                         Conducted Powers (dBm)
          Mode
                                         Low                         Mid.                         High
     802.11b_1 Mbps                     12.54                       13.69                        12.58
     802.11g_6 Mbps                     10.81                       11.83                        11.97
  802.11n(HT-20)_MCS0                   10.77                       11.71                        10.82
  802.11n(HT-40)_MCS0                   8.84                        10.99                         8.66


14.2 Bluetooth
                                                         Conducted Powers (dBm)
          Mode
                                         Low                         Mid.                         High
       BDR(GFSK)                        0.13                         0.80                         1.95
    EDR(∏/4DQPSK)                       -2.53                        -2.53                       -2.02
      EDR(8DPSK)                        -2.35                        -2.50                       -1.97




            This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                 KCTL Inc.                                  Report No.:
             65, Sinwon-ro, Yeongtong-gu,
         Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
    Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (21) of (51)
                    www.kctl.co.kr


14.3 Max. tune up power
            Mode                       Target Power                 Tolerance            Max. Allowed Power
                        Low              13.00 dBm                  ± 1.50 dB                  14.50 dBm
     802.11b          Middle             14.00 dBm                  ± 1.50 dB                  15.50 dBm
                       High              13.00 dBm                  ± 1.50 dB                  14.50 dBm
                        Low              11.00 dBm                  ± 1.50 dB                  12.50 dBm
     802.11g          Middle             12.00 dBm                  ± 1.50 dB                  13.50 dBm
                       High              12.00 dBm                  ± 1.50 dB                  13.50 dBm
                        Low              11.00 dBm                  ± 1.50 dB                  12.50 dBm
  802.11n(HT-20)      Middle             12.00 dBm                  ± 1.50 dB                  13.50 dBm
                       High              11.00 dBm                  ± 1.50 dB                  12.50 dBm
                        Low              9.00 dBm                   ± 1.50 dB                  10.50 dBm
  802.11n(HT-40)      Middle             11.00 dBm                  ± 1.50 dB                  12.50 dBm
                       High              9.00 dBm                   ± 1.50 dB                  10.50 dBm


          Mode                     Target Power                  Tolerance              Max. Allowed Power
       BDR(GFSK)                     1.00 dBm                    ± 2.00 dB                    3.00 dBm
    EDR(∏/4DQPSK)                   -2.00 dBm                    ± 2.00 dB                    0.00 dBm
       EDR(8DPSK)                   -2.00 dBm                    ± 2.00 dB                    0.00 dBm




            This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                    KCTL Inc.                                   Report No.:
               65, Sinwon-ro, Yeongtong-gu,
           Suwon-si, Gyeonggi-do, 16677, Korea                 KR17-SPF0003
      Tel : 82-31-285-0894 Fax : 82-505-299-8311                 Page (22) of (51)
                      www.kctl.co.kr




15. SAR Test Exclusions Applied
Per FCC KDB 447498 D01v06, The SAR exclusion threshold for distance < 50 mm is defined by the following
equation:




                                                 Maximum               Separation
                         Frequency
      Mode                                    Allowed Power             Distance                 ≤ 3.0
                            (MHz)                  (mW)                   (mm)
    Bluetooth               2 480                   2.00                     5                   0.630


Based on the maximum conducted power of Bluetooth and antenna to use separation distance, Bluetooth
SAR was not required.


This device contains transmitters that may operate simultaneously. Therefore simultaneous transmission
analysis is required. Per FCC KDB 447498 D01v06, simultaneous transmission SAR test exclusion may be
applied when the sum of the 1-g SAR for all the simultaneous transmitting antennas in a specific a physical
test configuration is ≤ 1.6W/kg. When standalone SAR is not required to be measured per FCC KDB 447498
D01v06, the following equation must be used to estimate the standalone 1-g SAR for simultaneous
transmission assessment involving that transmitter.




                                                 Maximum               Separation           Estimated SAR
                         Frequency
      Mode                                    Allowed Power         Distance (Body)              (Body)
                            (MHz)                  (mW)                   (mm)                   (W/kg)
    Bluetooth               2 480                   2.00                     5                   0.084




                This test report shall not be reproduced, except in full, without the written approval.
 KCTL-TIA002-004/1


                    KCTL Inc.                                        Report No.:
                 65, Sinwon-ro, Yeongtong-gu,
             Suwon-si, Gyeonggi-do, 16677, Korea                    KR17-SPF0003
        Tel : 82-31-285-0894 Fax : 82-505-299-8311                  Page (23) of (51)
                        www.kctl.co.kr




16. SAR Test Results
16.1 WLAN Body SAR Test Results
Frequency                       Max.
                 Average                                               Separation       Measured     Scaled      1 g SAR
                              tune up     Scaling           EUT
                  Power                                                 Distance        1 g SAR      1 g SAR          Limit
MHz       Ch.                  power       Factor       Position
                  (dBm)                                                   (mm)           (W/kg)      (W/kg)          (W/kg)
                               (dBm)
2 437      6       13.69       15.50        1.517           Front           5            0.031        0.047
2 437      6       13.69       15.50        1.517           Rear            5            0.089        0.135
2 437      6       13.69       15.50        1.517            Left           5            0.000        0.000
2 437      6       13.69       15.50        1.517           Right           5            0.002        0.003
                                                                                                                       1.6
2 437      6       13.69       15.50        1.517            Top            5            0.009        0.014
2 437      6       13.69       15.50        1.517       Bottom              5            0.000        0.000
2 412      1       12.54       14.50        1.570           Rear            5            0.071        0.111
2 462      11      12.58       14.50        1.556           Rear            5            0.093        0.145
<Note>
* SAR values were scaled to the maximum allowed power to determine compliance per KDB
 Publication 447498 D01v06.
* For WLAN 2.4 GHz, the highest measured maximum output power channel for DSSS was selected
 for SAR measurement. When the reported SAR is <= 0.8 W/kg, no further SAR testing is required.
 Otherwise, SAR is evaluated at the next highest measured output power channel. When any
 reported SAR is > 1.2 W/kg, SAR is required for the third channel. For OFDM modes (802.11g/n),
 SAR is not required when the highest reported SAR for DSSS is adjusted by the ratio of OFDM to
 DSSS specified maximum output power and it is <= 1.2 W/kg.


16.2 WLAN + Bluetooth Simultaneous Transmission
                              Separation          Scaled             BT Estimated                         1 g SAR
                   EUT                                                                   Σ 1 g SAR
   Band                        Distance          1 g SAR                  SAR                                 Limit
                 Position                                                                  (W/kg)
                                 (mm)               (W/kg)               (W/kg)                           (W/kg)
WLAN + BT          Rear             5               0.145                0.084             0.229               1.6
<Note>
* The above numerical summed SAR results for all the worst-case simultaneous transmission
 conditions were below the SAR limit. Therefore, the above analysis is sufficient to determine that
 simultaneous transmission cases will not exceed the SAR limit. And therefore no measured
 volumetric simultaneous SAR summation is required per FCC KDB Publication 447498 D01v06.


                This test report shall not be reproduced, except in full, without the written approval.
 KCTL-TIA002-004/1


                KCTL Inc.                                   Report No.:
             65, Sinwon-ro, Yeongtong-gu,
         Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
    Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (24) of (51)
                    www.kctl.co.kr




17. Test System Verification Results
2 450 MHz




            This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1


                KCTL Inc.                                   Report No.:
             65, Sinwon-ro, Yeongtong-gu,
         Suwon-si, Gyeonggi-do, 16677, Korea               KR17-SPF0003
    Tel : 82-31-285-0894 Fax : 82-505-299-8311               Page (25) of (51)
                    www.kctl.co.kr




18. Test Results




            This test report shall not be reproduced, except in full, without the written approval.
KCTL-TIA002-004/1



Document Created: 2017-10-23 15:00:14
Document Modified: 2017-10-23 15:00:14

© 2024 FCC.report