168002532 PRM-X6PRO-01 RF Exposure Rev-1

FCC ID: QAM018

RF Exposure Info

Download: PDF
FCCID_3044338

                  FCC TEST REPORT
                                     For

                  ActivConnect G Series Android PC

                      Model Number: PRM-X6PRO-01

                             FCC ID: QAM018




                  Report Number        :    WT168003326




Test Laboratory   :   Shenzhen Academy of Metrology and Quality
                      Inspection
                      National Digital Electronic Product Testing Center
Site Location     :   NETC Building, No.4 Tongfa Rd., Xili, Nanshan,
                      Shenzhen, China
Tel               :   0086-755-86928965
Fax               :   0086-755-86009898-31396
Web               :   www.smq.com.cn
E-mail                emcrf@smq.com.cn


                            TEST REPORT DECLARATION
 Applicant                 :_PROMETHEAN LIMITED
 Address                   :_PROMETHEAN HOUSE, LOWER PHILIPS RD WHITEBIRK
                            BLACKBURN,BB1 5TH UNITED KINGDOM
 Manufacturer              :_PROMETHEAN LIMITED

 Address                   :_PROMETHEAN HOUSE, LOWER PHILIPS RD WHITEBIRK
                            BLACKBURN,BB1 5TH UNITED KINGDOM
 EUT Description           : ActivConnect G Series Android PC

 Model No                  :_PRM—xX6PRO—01
 Trade mark                : Promethean

 Serial Number             i/
 FCC ID                    : QAMO18



Test Standards:

 KDB 447498 D01 General RF Exposure Guidance v0O6

The EUT described above is tested by Shenzhen Academy of Metrology and Quality
Inspection EMC Laboratory to determine the maximum emissions from the EUT.
Shenzhen Academy of Metrology and Quality Inspection EMC Laboratory is assumed full
responsibility for the accuracy of the test results.

The test report is valid for above tested sample only and shall not be reproduced in part
without written approval of the laboratory.




 Project
                                4.    J
 Engineer:            S e
                            Chen Silin 4# #k)

 Checked by:                     4ir                   Date: May.18,2016_______
                           (Lin Yixiang M28HM)

 Approved by:                   +4\                    Date: 2016
                             (Lin Bin Muat)




 Report No.: WT168003326                                                            Page 28


                                                  TABLE OF CONTENTS

TEST REPORT DECLARATION......................................................................................................... 2
1.       TEST RESULTS SUMMARY ................................................................................................... 4

2.       GENERAL INFORMATION ...................................................................................................... 5
         2.1.     Report information .......................................................................................................... 5
         2.2.     Laboratory Accreditation and Relationship to Customer ......................................... 5
3.       PRODUCT DESCRIPTION ...................................................................................................... 6
         3.1.     EUT Description ............................................................................................................. 6
4.       RF     EXPOSURE ....................................................................................................................... 7
         4.1.     LIMIT FOR MAXIMUM PERMISSIBLE EXPOSURE(MPE) .................................... 7
         4.2.     MPE Calculation Method .............................................................................................. 7
         4.3.     CALCULATED RESULT ............................................................................................... 8




        Report No.: WT168003326                                                                                                            Page 3/8


1. TEST RESULTS SUMMARY

                             Table 1 Test Results Summary
      Test Items                        Test Results
      RF Exposure                          Pass
      Remark: “N/A” means “Not applicable.”




   Report No.: WT168003326                                  Page 4/8


2. GENERAL INFORMATION

  2.1. Report information

   2.1.1.This report is not a certificate of quality; it only applies to the sample of the specific
       product/equipment given at the time of its testing. The results are not used to indicate
       or imply that they are application to the similar items. In addition, such results must
       not be used to indicate or imply that SMQ approves recommends or endorses the
       manufacture, supplier or use of such product/equipment, or that SMQ in any way
       guarantees the later performance of the product/equipment.

   2.1.2.The sample/s mentioned in this report is/are supplied by Applicant, SMQ therefore
       assumes no responsibility for the accuracy of information on the brand name, model
       number, origin of manufacture or any information supplied.

   2.1.3.Additional copies of the report are available to the Applicant at an additional fee. No
       third part can obtain a copy of this report through SMQ, unless the applicant has
       authorized SMQ in writing to do so.

  2.2. Laboratory Accreditation and Relationship to Customer

         The testing report were performed by the Shenzhen Academy of Metrology and
       quality Inspection EMC Laboratory (Guangdong EMC compliance testing center), in
         their facilities located at Bldg. of Metrology & Quality Inspection, Longzhu Road,
       Nanshan District, Shenzhen, Guangdong, China. At the time of testing, Laboratory is
                                accredited by the following organizations:
          China National Accreditation Committee for Laboratories (CNAS) accredits the
       Laboratory for conformance to FCC standards, EMC international standards and EN
                             standards. The Registration Number is L0579.

        The Laboratory is listed in the United States of American Federal Communications
        Commission (FCC), and the registration number are 446246 806614 994606(semi
                                         anechoic chamber).
          The Laboratory is registered to perform emission tests with Industry Canada (IC),
                               and the registration number is IC4174.

        TUV Rhineland accredits the Laboratory for conformance to IEC and EN standards,
                           the registration number is E2024086Z02.
                                   Measurement Uncertainty




    Report No.: WT168003326                                                                 Page 5/8


3. PRODUCT DESCRIPTION

  3.1. EUT Description

                        Table 2 Specification of the Equipment under Test
 Product           ActivConnect G Series Android PC
 Type:
 Hardware          PRM-X6PRO-01
 Version:
 Software          V1.0.9
 Version :
 FCC-ID:           QAM018
 Frequency:        Wifi:2412MHz-2462MHz; U-NII 1(5150~5250MHz); U-NII 3(5725~5850MHz)
                   Bluetooth: 2402MHz-2480MHz
 Type(s) of        DSSS (DBPSK, DQPSK, CCK) for 802.11b
 Modulation:       OFDM (BPSK, QPSK, 16QAM, 64QAM) for 802.11a/g/n
                   OFDM (BPSK, QPSK, 16QAM, 64QAM,256QAM) for 802.11ac
                   Bluetooth :GFSK, pi/4-DQPSK, 8DPSK
 Antenna           PIFA Antenna    2dBi
 Type:
 Operating         120V AC Adapter;
 voltage:          4.8V (Low)/5.0V (Nominal)/ 5.3V (Max)

Remark:    /




     Report No.: WT168003326                                                     Page 6/8


4. RF    EXPOSURE

  4.1.LIMIT FOR MAXIMUM PERMISSIBLE EXPOSURE(MPE)

        4.1. This product can be classified as mobile devics, so the 20om separation cistance
        warning is required. in this section, the power density at 20om location is calculated to
        examine it t is lower than the limit
        4.1.1. Limits for Occupational / Controlled Exposure
          Frequency Range Electrie Fild       Magnetie Fild. Power Density (8)| Averaging Tme
                                                                                  *(2RnS, /9
               qurty     Strongth (E) (Vim)|Strongth (#) (A/m)] (mWrem)            tmnuen
               os30             o1                 163            1007                 s
               3030           teeeit              «s07t          C                     s
               soa00           s1«                o.183             10                 s
              a00—1500                                            rraco                s
            1800—100.000                                             s                 s
         1.2. Limits for General Population / Uncontrolled Exposure
          Frequeney Range ElectrieField       Magnetic Field [Power Density (8)) Averaging Time
                                                                                   PTERNS 79
                quite    Strength (€) (Vim)[Strongth (4)(A/m)|   (rmifem)           {minutes)
               os134            ore                183             (roo                so
               13430           soar               210             (rsom>               s
               20300            ars               oors              o2                 so
              300—1500                                            ernsoo               so
            1800—100,000                                             10               3
        F = frequency in NHz Plane—wave equivalent power density
        ‘Planewave equivalent power density
  4.2.MPE Calculation Methad

        Power Density: Pd(Mwom‘)=P°G /4 x at
        P=Peak RF output power (mW)
        G=EUT Antenna numeric gain (numeric)
        d=Separation distance etween raciator and human bedy (m)




    Repen No wrieasosses                                                                          Pase 72


4.3. CALCULATED RESULT

     BT
     P=-2.00dBm(max:0.00063W)
     G=2dBi (numeric:1.59)
     d=200mm
     Pd=0.00063*1.59/4*3.14*0.04=0.002<1

     BLE
     P=5.88dBm (max:0.0038W)
     G=2dBi (numeric:1.59)
     d=200mm
     Pd=0.0038*1.59/4*3.14*0.04=0.012<1

     WLAN 2.4G
     P=15.49dBm (max:0.0354W)
     G=2dBi (numeric:1.59)
     d=200mm
     Pd=0.0354*1.59/4*3.14*0.04=0.112<1

     WLAN 5G
     P=14.32dBm (max:0.027W)
     G=2dBi (numeric:1.59)
     d=200mm
     Pd=0.027*1.59/4*3.14*0.04=0.086<1




  Report No.: WT168003326                  Page 8/8



Document Created: 2016-06-20 14:40:45
Document Modified: 2016-06-20 14:40:45

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC